| 1 | Excavation in trenches n exc 1.50 metre wide & n exc 1.50 metre in depth for foundation etc or for shafts, wells, cesspits manholes, pier holes etc n. exc 10 Sqm on plan n exc 1.50 metre in depth and getting out in any type of soil, complete all as specified and directed. |
| 2 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc. 25cm thick each layer of soil, complete all as specified and directed. |
| 3 | Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.50m above the starting point, complete all as specified and directed. |
| 4 | Plain cement concrete M-7.5, nominal mix, D-2, using 40mm graded mechanically crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed. |
| 5 | Reinforced cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, all as specified. |
| 6 | Reinforced cement concrete 1:2:4 type B-1, ( using 20mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts, all as specified. |
| 7 | Reinforced cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintel over 1.50m span, complete all as specified and directed. |
| 8 | Reinforced cement concrete (nominal mix) M-15, type B-1 using 20mm graded crushed stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed. |
| 9 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) in rough finished flat surface of concrete, complete all as specified and directed. |
| 10 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide for roughly finished flat surfaces of concrete, all as specified. |
| 11 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, for roughly finished flat surfaces of concrete, all as specified. |
| 12 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions, for roughly finished square, rectangular or polygonal surfaces of concrete, all as specified. |
| 13 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. For fair finished flat surfaces of concrete, complete all as specified and directed. |
| 14 | TMT steel bars 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed. |
| 15 | TMT steel bars 5 to 10mm dia cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips as in stirrups, spacers and binders, complete all as specified and directed. |
| 16 | Fly ash brick work with old size bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 (1 cement : 6 coarse sand), complete all as specified and directed. |
| 17 | Brick work with old sizefly ash bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed. |
| 18 | Hardcore of broken stone or boulders of gauge not exc. 63mm deposited, spread and levelled in layers not exc. 15cm thick, watered and rammed to a true surface, complete all as specified and directed. |
| 19 | 75mm thick Plain cement concrete 1:4:8 nominal mix, D-2, using 40mm graded mechanically crushed stone aggregate as in sub base flooring, complete all as specified and directed. |
| 20 | Rendering cement plaster 15mm thick in cement mortar 1:6 (1 cement : 6 coarse sand) on internal fair faces of brick wall or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed. |
| 21 | Rendering cement plaster 15mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers on fair faces of brick or stone walls finished even and smooth without using extra cement, mixed with and including WPC, complete all as specified and directed. |
| 22 | Rendering cement plaster 10mm thick in cement mortar 1:3 (1 cement : 3 coarse sand) on ceiling surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed. |
| 23 | Two coats of oil bound distemper over one coat of chalk whiting including preparation of new plastered surfaces of walls, all as specified and directed |
| 24 | Applying two coats of cement base paint on newly plastered or previously undecorated wall surfaces including preparation of surface, tint and shade as approved by Engr-in-Charge |
| 25 | Preparation of new plastered surfaces of ceiling and applying three coats of white wash complete, all as specified |
| 26 | Plain cement concrete M-10, nominal mix, type C-2, using 40mm graded mechanically crushed stone aggregate, 75mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5cm deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), complete all as specified and directed. Note:- The unit rate include for use of form work (straight or curved). |
| 27 | Plain cement concrete M-15, nominal mix, type B-0, using 12.5mm graded mechanically crushed stone aggregate as inflooring, 25mm thick, surface finished even and rough to receive top finish or chamfering of RCC chajja with proper slope to drain off storm water, complete all as specified and directed. |
| 28 | Screed bedding layer 15mm thickin cement mortar 1:6 (1 cement : 6 coarse sand), finished fair for laying floor finish complete all as specified and directed. |
| 29 | Non skid, Premium class I grade, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 Sqm, in floors and the like, set and jointed in neat cement slurry and pointed in coloured cement to match,complete all as specified and directed. |
| 30 | Glazed coloured tiles of size 350mmx250mmx7mm /450mmx350mmx7mm thick as in vertical surfaces such as jointed in neat cement slurry and pointed with coloured cement to match and including 10mm thick plastering in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed. |
| 31 | Vitreous China wash down water closet (pedestal pattern), coloured including traps, connection to drain or outgoing pipe, flushing pipe, anti-syphonage pipe complete including fittings, PVC coloured seat cover black closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device and chromium plated jet including 15mm dia PVC connection 600mm with CP brass coupling nuts and PVC washers at both ends, fixed, including 32mm dia PVC long bend flush pipe 90cm long pipe and fixed, complete all as specified and directed |
| 32 | Supply and fixing PVC valveless, syphonic action type flushing cistern 10 litres capacity low level with inlet, ball valve, float and handlewith brackets including 32mm dia PVC long bend flush pipe 90cm long snd 15mm dia PVC connection 600mm with CP brass coupling nuts and PVC washers at both ends, fixed, complete all as specified and directed. |
| 33 | Wash basin, Vitreous China (Flat back type) size 550mmx400mm, crystal white with and including cutting for and pinning on ends of brackets, 450 mm long PVC connections 15mm size with PTMT coupling nuts at both ends, trap, grating and Union for discharge pipe, waste, chain and plug and porcelain stopper, waste pipe of polythylene of low or high density or PVC of 32mm dia including Pillar taps, 15mm bore cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot\" or ‘Cold\" with long screwed shanks and fly-nuts, 32mm dia waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed, screwed for iron pipe, completeall as specified. |
| 34 | Bib taps, fancy type long body 15mm bore, cast copper alloy with crutch or butterfly handle, screwed down, chromium plated screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 35 | Angle valve/stop valves, cast copper alloy, chromium plated, fancy type, screwed down, high pressure with crutch or butterfly handle, screwed both ends for 15mm bore iron pipe or for unionscomplete all as specified and directed. |
| 36 | Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed of 15 mm bore and fixed complete, all as specified. |
| 37 | Soap dish, chromium plated, fixed to plugs with chromium plated, brass screws, complete all as specified and directed. |
| 38 | Rotational moulded polyethylene water storage tank 500 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position including PVC float ball valve 20mm dia epoxy coated aluminium rod with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line, complete all as specified and directed. |
| 39 | 600mmx450mm bevelled edge looking mirror of selected quality with 6mm thick polished glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with CP brass screws and cup washers, complete all as specified and directed. |
| 40 | Gun metal, globe or gate valves, screwed down, high pressure with crutch or butterfly handle, screwed both ends for 20mm bore iron pipe or for unions and fixed complete, all as specified |
| 41 | Mild steel galvanized iron water tubing 15mm bore with screwed & socket joints, medium grade, in short lengths, with and including all fittings, such as tank nipples, sockets, bends, elbows, unions, tees, diminishing pieces etc. Fixed to wall or ceiling or laid in floor, complete all as specified and directed. |
| 42 | Mild steel galvanized iron water tubing 20mm bore with screwed & socket joints, medium grade, in short lengths, with and including all fittings, such as tank nipples, sockets, bends, elbows, unions, tees, diminishing pieces etc. Fixed to wall or ceiling or laid in floor, complete all as specified and directed. |
| 43 | Mild steel galvanized iron water tubing 25mm bore with screwed & socket joints, medium grade, in short lengths, with and including all fittings, such as tank nipples, sockets, bends, elbows, unions, tees, diminishing pieces etc. Fixed to wall or ceiling or laid in floor, complete all as specified and directed. |
| 44 | PVC (SWR) bends any radius, 110mm bore jointed with solvent cement (fitted with oval access door), complete all as specified and directed. |
| 45 | PVC (SWR) bends any radius, 75mm bore jointed with solvent cement (fitted with or without oval access door), complete all as specified and directed. |
| 46 | PVC (SWR) floor trap, plain with grating including jointing with solvent cement, dia of outlet 75mm in cement concrete 1:2:4 type B-1, fixed, complete all as specified and directed. |
| 47 | PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with adjustable clamps of bore 110mm, complete all as specified and directed. |
| 48 | PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with adjustable clamps of bore 75mm, complete all as specified and directed. |
| 49 | PVC connection 15mm size with PTMT nuts at boths end 600mm long and fixed, complete all as specified and directed. |
| 50 | Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed. |
| 51 | Construction of Soakage well of size 1.80 metre dia and 3.00 metre effective depth below inlet pipe comprising intercepting chamber, screen chamber built in brick masonary, RCC cover slab in RCC M-25 design mix/SFRC cover, inetrconnecting pipes RCC/DWC, excavation in any type of soil, PCC 1:3:6 type C-2 in foundation, brick work with sub class B bricks built in cement mortar 1:4, brick bat filling, complete all as shown on drawing No. CEPZ/C-TD/013/13 sheet 1/5 to 5/5 and as specified. |
| 52 | Damp proof course in 25mm thick Plain cement concrete M-15, nominal mix, type B-0, using 12.5mm graded mechanically crushed stone aggregate including necessary formwork to horizontal or vertical surface, complete all as specified and directed. |
| 53 | Factory made solid PVC Door/window/ventilator Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet and edges shall be painted to match with prelam sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing on page No 180 of MES SSR 2020 Part-II, complete all as specified and directed. |
| 54 | Factory made fully glazed or gauzed PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail;including glass panes or wire cloth,suppling & fixing in the frame at site, as per specifications and drawing complete all as as specified and directed. |
| 55 | Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of 5 mm thick plain coloured PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement,suppling & fixing in the frame at site, as per specifications and drawing complete all as as specified and directed. |
| 56 | Butt hinges (ISI marked), medium weight, cold rolled, mild steel 100mm long, complete all as specified and directed. |
| 57 | Aluminium anodised, (ISI marked), barrel tower bolts of extruded section, length of bolt 150mm, fixed, complete all as specified and directed. |
| 58 | Surface excavationnot exceeding 30 cms deep and averaging 15cms deep and getting out in any type of soil, complete all as specified |
| 59 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete including removal of debris to a distance exc 1.50 km but n.exc 2 km outside the Military Station, complete all as specified and directed. |
| 60 | 75mm thick Plain cement concrete 1:3:6 nominal mix, C-2, using 40mm graded mechanically crushed stone aggregate as in sub base flooring, complete all as specified and directed. |
| 61 | Chequered cement concrete tiles machine pressed of size 250cmx25cmx 20mm thick with grey cement, set jointed & pointed in neat cement slurry mixed with pigment to match the shade of the slab in floors laid over and including 15mm thick screed bed in cement mortar 1:4, complete all as specified and directed. |
| 62 | Plain cement concrete 1:3:6, type C-1 using 12.50mm graded mechanically crushed stone aggregate as in lintels upto 1.50 metre clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, chamfered angles and throating, complete all as specified and directed. Note :- (i) The unit rate include for use of form work (straight or curved). |
| 63 | M & L for point wiring with 1.5 sqmm (Nominal Area) FRLS PVC insulated unsheathed multi stranded copper conductor, 1100 Volts grade, in and includingconcealed PVC conduit(ISI marked) with accessories such as bends, cross, elbow, tees etc. of suitable sizeincluding concealedMS pressed steel (Modular sunken box) terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and Modular cover plate as top cover (ISI marked) including continuous earth wire FRLS PVC insulated unsheathed 1.5 Sqmm (nominal area) copper multistranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for one light point controlled by one switch, complete all as specified and directed. Note : i)Wiring Colour code i.e. Red/Yellow/Bluefor Phase, Black for neutral and Green for earth shall be maintained.ii) Rate of cutting chases, cement plaster, white wash and making surface good as existing surface included in quoted rate.iii) Point wiring is considered for Modular Switches and sockets. Rate of Metallic Sunken box and modular sheet cover plate and other connected accessories required for modular point wiring included in quoted rate.iv) Switch and sockets will be paid seperately under relevant item. |
| 64 | All as per item No 63 above but for ceiling fan/ exhaust fan controlled by one 6A switch, one way complete all as specified as directed. |
| 65 | All as per serial item No \"63\" above, but for one 3 pin 5 Amps socket outlet on the independent board with 1.50 sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 1.50 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed. |
| 66 | All as per serial item No \"63\" above, but for one 3 pin 5 Amps socket outlet on the same board with 1.50 sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 1.50 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed. |
| 67 | All as per serial item No \"63\" above, but for 5 pin 15 amps socket out let on independentwith 2.50 Sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 2.50 Sqmm stranded copper conductor cable as continuous earth wire, complete all as specified and directed. |
| 68 | S & F for modular switch 6A one way, single module, complete all as specified and directed. |
| 69 | S & F for modular switch 16A one way, single module, complete all as specified and directed. |
| 70 | S & F for modular socket for 6A 2/3 pin combined, 2 module, complete all as specified and directed. |
| 71 | S & F for modular socket for 6A/16A, 5 pin combined, 2 module, complete all as specified and directed. |
| 72 | M & L for ceiling rose 65 x 50mm three terminals, fixed, complete all as specified and directed. |
| 73 | Supply and fixing for AC exhaust fans, plastic body, single phase, 230 volts, 250 mm sweep including grouting the ragged bolts in wall, fixing the frame on the exhaust side and connecting up with PVC insulated three core 1.50 sqmm copper cablefrom ceiling rose to exhaust fan, complete all as specified and diercted. |
| 74 | S&F LED tube light fitting 1x 20 W, 220V, decorative type with driver, ultra slim square profile LED lighting fixture, environment friendly, energy efficient ready to use completewith all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and directed. |
| 75 | Supply and fixing LED light fitting mirror type with high output diffuser 2 feet, 10 watt, 6000 K, 220 volts, AC decorative type with extruded polycarbonate having efficiency 120 lumens /watt with driver holder including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 76 | S & F for MCB SP 6 to 40 amps 240 Volt,10 KA, \"B\" series, complete all as specified and diercted. |
| 77 | S & F for MCB SPN 40 amps 240 Volt, 10 KA, \"B\" series, complete all as specified and diercted. |
| 78 | Sheet metal enclosures factory made flush fixed for DBs when MCBs to be used, single pole and neutral (double Door powder coated), 8 way, 240 volts with 200 Amp rated bus bar, complete all as specified and directed. |
| 79 | Supply and installing of the electric water storage heater (Geyser) of ABS body type of 25 litre capacity with rated power 2 KW, BEE, 5 star rated, vertical type, thermally insulated Mild steel tank with glass line coating inside the tank alongwith glass lined incoloy heating element with anti corrosive magnesium anode, NRV, thermostate, indicators and temperature adjustable knob including steel braided flexible connection for pipe of size 15mm dia bore GI hexagonal adopters/Nuts on both side of inlet (cold water supply) and outlet (hot water supply) and including provision of wall mounting arrangement and mounting on wall with suitable size of anchor bolts with complete connection of water including testing after installation, complete all as specified and as directed by Engr-In-Charge. |
| 80 | Supply & laying 1100 volts grade heavy duty cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 10 sqmm, including taking out old cable, complete all as specified and directed. |
| 81 | Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.50m below ground level, connecting to galvanised iron wire 4.00mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in plain cement concrete M-20 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-20 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixingarrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m, all as per electricalplate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.NOTE :- Item of earthing includes the cost of 7.5 m long galvanised iron earth wire 4mm size and protection pipe of 15mm bore galvanised iron light grade and earth work. |