| 1 | Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for laying of cable,poles stay etc. and getting out complete all as specified. |
| 2 | Excavation in trenchs .exc. 1.5 mtr in depth but not exceeding 3 mtr in depthand getting out in any type of soil complete all as specified. |
| 3 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each complete all as specified. |
| 4 | Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified. |
| 5 | Sandcushioningwith clean dry sandto cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cablecomplete all as specified. Note : For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I |
| 6 | Supply and laying of classB bricks for under ground cable protection as directed by Engineer- in - charge |
| 7 | Taking out existing damage/unservisable PVC\ XLPE insulated, armoured, aluminium conductor 1100V grade cable of any size and core from trenches, pipes, walls and/or poles, complete all as specified . Note: Excavation and earthwork shall be measured and paid for separaetly |
| 8 | Supply & Laying ofXLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 400 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked,laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified. |
| 9 | All as per item No 08 above but cable of size 240 Sqmm, 3.5 core |
| 10 | All as per item No 08 above but cable of size 185 Sqmm, 3.5 core |
| 11 | All as per item No 08 above but cable of size 120 Sqmm, 3.5 core |
| 12 | All as per item No 08 above but cable of size 95 Sqmm, 3.5 core |
| 13 | All as per item No 08above but cable of size 70 sqmm 3.5 core |
| 14 | All as per item No 08 above but cable of size 50 Sqmm, 3.5 core |
| 15 | All as per item No 08 above but cable of size 35 Sqmm, 3.5 core |
| 16 | All as per item No 08 above but cable of size 25 Sqmm,3.5 core |
| 17 | All as per item No 08 above but cable of size 25 Sqmm, 2 core |
| 18 | All as per item No 08 above but cable of size16 Sqmm, 4 core |
| 19 | All as per item No 08 above but cable of size 16 Sqmm, 2 core |
| 20 | All as per item No 08 above but cable of size 10 Sqmm, 4 core |
| 21 | All as per item No 08 above but cable of size 10 Sqmm, 2 core |
| 22 | S&Fin repair heat shrinkable end joint (indoor/outdoor) for 1100 volt grade XLPE cable of size 400 Sqmm to 500 Sqmm, 3.5 core complete all as specified |
| 23 | All as per item No 22 above but of size 185 Sqmm to 300 Sqmm, 3.5 core complete all as specified |
| 24 | All as per item No 22 above but of size 70 Sqmm to 150 Sqmm, 3.5 core complete all as specified |
| 25 | All as per item No 22 above but of size 25 Sqmm to 50 Sqmm, 3.5/4 core complete all as specified |
| 26 | All as per item No 22 above but of size 4 Sqmm to 16 Sqmm, 3.5/4 core complete all as specified |
| 27 | S&Fin repair heat shrinkable straight through jointfor 1100 volt grade XLPE cable of size 300 Sqmm to 400 Sqmm, 3.5 core complete all as specified |
| 28 | All as per item No 27 above but of size 185 Sqmm to 240 Sqmm, 3.5 core complete all as specified |
| 29 | All as per item No 27 above but of size 70 Sqmm to 150 Sqmm, 3.5 core complete all as specified |
| 30 | All as per item No 27 above but of size 25 Sqmm to 50 Sqmm, 3.5/4 core complete all as specified |
| 31 | All as per item No 27 above but of size 4 Sqmm to 16 Sqmm, 3.5/4 core complete all as specified |
| 32 | S&Fin repair 100 mm bore Tubes‘light grade’, galvanized with all fittings, laid in trenches or fixed along poles with mild steel clamps, as protection to cable, complete all as specified . |
| 33 | S&Fin repair 80 mm bore Tubes‘light grade’, galvanized with all fittings, laid in trenches or fixed along poles with mild steel clamps, as protection to cable, complete all as specified . |
| 34 | S&Fin repair 50 mm bore Tubes‘light grade’, galvanized with all fittings, laid in trenches or fixed along poles with mild steel clamps, as protection to cable, complete all as specified . |
| 35 | S&Fin repair 40 mm bore Tubes‘light grade’, galvanized with all fittings, laid in trenches or fixed along poles with mild steel clamps, as protection to cable, complete all as specified . |
| 36 | Supply & install steel tubular pole swaged welded with MS base plate size 30cm x 30cm x 6mm thick final taper plug bolts nuts & washers as per IS: 2713 (part-I) 1980 made out of MS tubing including painting of two coats of aluminium paint of approved quality over one coat of red oxide primer length 9.00 mtr long 410 SP -31 using for any description of external electric work including dismantling of old unsv RCC pole all as specified and directed by Engr-in-charge. Note: Earthwork, PCC work in foundation & coping of pole, cross arms, danger notice board and anti climbing devices shall be measured and paid separately. |
| 37 | S&F street light bracket made out of 40/32mm dia fancy type top mounted, 1.50 mtr long GI tubing, \"medium grade\" ISI marked, bent to required shape and angle as per site requirement with and including MS clamps size 30X6mm,with nuts, bolts, washers etc for fixing street light fittings and bracket, duly painted with two coats of aluminium paint over a coat of red oxide primercomplete all as specified and as directed. |
| 38 | S&F street light high wattage (60 Watts) street light fittingsenergy efficient Intergral type LED 60W ,IP 66,PF > 0.9,lumins 100/watt Street light luminaire comprising of epoxy powder coated hsg, enclosed with glass cover in frame mountedtesting complete all as specified and directed. |
| 39 | Supply and fixing LED type solar street light 25W fitting with following features/specification:- 1. Luminaire:-Aluminium housing LEDs for light source optics with high effeciency driver & MPPT charge controller, Excellent heat dessipation IP 65 protection, High birghtness and high efficiency of more than 120 lm/W new age LEDs, individual peanut optical lenses for uniform light distribution system output: 2200 lm.2. Solar Panel :- Polycrystaline solar cells.3.battery :-Tubular construction, 12 V 100 AH, 75% depth of discharge, galvanised battery box 3 days autonomy, long life, weather proof, long back-up ideal for cloudy conditions.4.Pole:- Galvanised pole, Rigid and safe, corrossion free length 6 mtr.With optimum thermal management and heat sink design and microprocessor based charge controller and led driver maximizes the performance of panel & battery complete all as specified and directed. |
| 40 | Supply and fixing of Junction box made out ofthermo plastic material of size 240x130x110 mm with provision of three phase cable connector incomming and out going with MCB SP 6-32 amps for security light fitting/PTLIP 65 protection totally enclosed weather proof with cable entryalong with GI clamps nut bolts & washer fixed on pole including dismantling/taking out old unserviceale one all as directed. |
| 41 | S&FPVC insulated copper wire FRLS of size 2.5 Sqmm (nominal area) 3 core for street lightas directed by Engr -in-charge. |
| 42 | M&L for Cement concrete 1:4:8 type D-2 using 40 mm graded crushedstoneaggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work complete all as specified and directed. |
| 43 | M&L for Cement concrete 1:3:6 type C-1 using 20 mm graded crushedstone aggregate in coping/padestal to poles including provision of necessary form work finishing the exposed surface even and smooth in cement mortar 1:3and applying two coats of white wash complete all as specified and directed. |
| 44 | Boring of holes under road,pavement.hard standing by trenchless technology using ultra sounding technique and necessary machine for inserting GI pipe upto 100mm dia complete all as specified and as directed. |
| 45 | Preparation of surfaces of LT Steel poles by and painting applying one coats of aluminium paint and writing pole number inblack and yellow. Strip upto 1.5 mtr height at an intervals of 30cm each from the ground level and above coping for 09.00 mtr pole including Pole marking (Pole Numbers in 12 cm round circlein white colour and marking of pole numbers with black colour word size 7 cm long) all as directed at site. |
| 46 | M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0 mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and including galvanised iron or steel earth strip 32 x 6 mmby means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing strip protected by galvanised iron or steel pipe 50 mm bore medium grade and connected to continuous earth wire on pole/ test point.Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive ofexcavation and earth work in any type of soil, charcoal, salt, funnel , PCC pit and RCC cover complete all as specified & directed by Engr-in-Charge.Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labourfor connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal, dust, common salt and ground enhacement material as required to bring the earthing resistance as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. |
| 47 | Note: For the purpose of arriving at lumpsum amount, the amount of credit schedule i.e Sch \"A\" section II (i.e Rs 1,38,050.00 shall be deducted from the total amount arrived. |
| 48 | Total of Schedule \"A\" Rs. |