| 1 | Surface dressing and site clearance not exc 15 cm deep complete all as specified and directed. |
| 2 | Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sqm on plan and not exc 1.5 m in depth and getting out complete all as specified and directed. |
| 3 | Spreading and levelling of excavated soilin layers not exc. 25cm thick, well ramming including watering as required complete all as specified and directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 5 | Removing excavated material not exc. 50 m distance and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed. |
| 6 | M&L PCC 1:4:8 Type D-2 (using 40mm stonegraded stone aggregate) as infoundation /bed of manhole / sub base and mass concrete complete all as specified and directed. |
| 7 | M&L for Reinforced cement concrete M-25 design mix as inFoundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 8 | M&L Reinforced cement concrete M-25 design mix as inColumns, pillars, piers, posts and struts complete all as specified and directed. |
| 9 | M&L Reinforced cement concrete M-25 design mix as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 10 | M&L Reinforced cement concrete M-25 design mix as in chajja and the like complete all as specified and directed. |
| 11 | M&LReinforced cement concrete M-25 design mix as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 12 | Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to battercomplete all as specified and directed. |
| 13 | Use and waste formwork to sidesof pillars, posts, struts, piers, columnsand stanchionscomplete all as specified and directed. |
| 14 | Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelvesincluding sup- ports, overhangs , etc. also splays between floors and beams, etc complete all as specified and directed. |
| 15 | Use and waste formwork to chullah hoods, chajjas, troughs and similar items includingedges complete all as specified and directed. |
| 16 | Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landingsand similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 17 | M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to anyradius for wall construction in CM 1:6 (cement : sand )complete all as specified and directed. |
| 18 | M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan to anyradius forhalf (1/2) brick thick wall in CM1:4 (cement : sand )complete all as specified and directed. |
| 19 | M&L Hardcore of gauge not exc. 63 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surfacef complete all as aepcified and as diretced |
| 20 | M&L for 75mm thick cement concrete type C-2 (1:3:6)(using 40 mm graded stone aggregate ) as in plinth/flooringprotection and path finished even and smooth without using extra cement complete all as specified and directed. |
| 21 | M&L for pre-polished machine cut Kota stone in flooring20-25mm thicklaid over 20mm thick screed bed in CM (1:6)and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. (Note : only one stone piece on one tread with nosing one side) |
| 22 | M&L forpre-polished machine cut Kota stone slab in skirting 20-25mm thick on vertical surfaces over 10mm thick cement plaster in (1:3) such as risers, skirting etc. jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and taking down existing skirting complete all as specified and directed.(Note : only one stone piece on one riser) |
| 23 | M&L for water proofing treatment carried out as under complete all as specified and directed:- (a) M&L for 10 mm thick screed bed or rendering in CM 1:4 on RCC roof slab ,mix with water proofing compound @ 2% by wt of cement finished even and smooth without using extra cement (b) M&L for Bitumen primer @ .30 ltrs/sqmfor use in waterproofing and damp-proofing treatments(c) M&L Applying evenly a tack coat of in dustrial bitumen 85/25 at the rate of1.2 kg per sqm including cleaning surfaces (d) M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application .The over lap shall be minimum 15mm on end lap and 100mm side laps(e) M&L for 20 mm thick locally available PCC tiles laid over and including 15 mm thick screed in cement mortar 1:4 mixed with and including liquid water proofing comound @ 200 ml per bag of cement, grouted flush in cement mortar 1:3 mixed with 5% of crude oil by weight of cement complete all as specified and directed.Note:-Rate of water proofing compound deemed tobe included in quoted rate |
| 24 | M&L Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or weldedcomplete all as specified and directed. |
| 25 | S & F window guard bar,ISI marked Framed work such as grills with making provision in grills for openable for desert cooler etc, gratings, with ends of bars shouldered and/or riveted,con- forming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 26 | M&L Steelventilators, top hung type, with glazing barscomplete all as specified and directed. |
| 27 | S&F 3mm thicksheet glass pane not exc.0.50 sqm in each pane of selected quality fixing with glazing clips/strips in windows/ventilators shutterscomplete all as specified and directed. |
| 28 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening Fe- 290 (Gde E- 165)complete complete all as spd and directed. |
| 29 | S&F Mild steel, plain, black sheet.80mm thick forsteel gates and similarwork, cut to size, holes punched; including M&L round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. complete all as specified and directed. |
| 30 | M&L for two coat of synthtic enamel paint over a coat of primerin steel surface includingpreparation of new Surfaces of any description, over 10cm in width or girth when unconnected with other painting or when painted in a different tint complete all as specified and directed. |
| 31 | M&L for rendering 15 mm thick plaster external in cm 1:4 mixed with Pidi Proof 101 LW (+) of Dr fixit or equivalent integral water proofing admixture @200 ml/bag of cement and finish the surafce even and smooth (without using extra cement )completely all as specified and directed.Note: Pidi proof deemed tobe included to quoted rate in item |
| 32 | M&L for rendering 15 mm thick in cement mortar 1:6 and finish the surafce even and smooth (without using extra cement ) for internal walls complete all as specified and directed. |
| 33 | M&L for rendering 10 mm thick in cement mortar 1:3 on concrete surface of ceiling includingfinishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 34 | M&L for applying three coats of white wash on ceilling including prepreation of new surfacecomplete all as specified and directed. |
| 35 | M&L for preperation of newly plastered concrete surface of wall & applying three coat of white wash on wall surfacecomplete all as specified and directed. |
| 36 | M&L Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as specified and directed. |
| 37 | S&F Mild steel TMTbars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoopingfor columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 38 | Ditto all as per item no 37 above but 8mm dia TMT bar |
| 39 | M&L Mild steel TMTbars 8mm dia and over upto and including 10mm diain stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hoopingfor columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 40 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 41 | M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sandcomplete all as specified and directed. |
| 42 | M&L PCC 1:2:4 Type B1 (using 20mmgraded stone aggregate) as in copings, kerbs and like incl weathering slightly rounded or chamfered angles and throatingcomplete all as specified and directed. |
| 43 | M&L for 25 mm thick plain cement concrete type B-0 ( 1:2:4)(using 12.5 mm graded stone aggregate) as in floor / slab complete all as specified and directed. |
| 44 | M&L for 75 mm thick plain cement concrete type C-1( 1:3:6)(using 20 mm graded stone aggregate) as in path finished even and fair complete all as specified and directed. |
| 45 | M&L for cutting holes in brick walls built in cement mortar exc half brick but nexc one brick for inserting hold fast and making good dismentledportion in cement mortar 1:3 or cement concrete type B1 (1:2:4) using 20 mm graded stone aggregate as required to match existing surface complete all as specified and directed. |
| 46 | S&F 35mm thick second class Hard wood Kiln seasoned and chemically pressure treated glazed & skeleton door shutters, open rebated and prepared to receive glass or gauze (without sash bars) edges of framing plain, chamfered, or rounded, fitted with and including cut and mitred beads for securing glass, gauge etc, size of members of shutters as specified in SSR Pt-I, Sec-8, clause 8.24 (a)fixed to chowkhats complete all as specified and directed. |
| 47 | S&F 100 mm long medium weight, cold rolled mild steel butt hinges complete all as specified and directed. |
| 48 | S&F 150mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed. |
| 49 | S&F 150mm size aluminium anodised alloy handles fabricated type complete all as specified and directed. |
| 50 | S&F 300mm long mild steel, sliding door bolt, with hasp and staple (bolt type) cast or extruded section and fixing bolts sliding bolt not less than 16mm dia of shoot/bolt of extruded section complete all as specified and directed. |
| 51 | S&F stainless Steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specifed and directed.(Note :- Quoted rates shall be deemed to include the cost of any type of beading required for fixing the wire mesh etc.) |
| 52 | M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint including one coat of pink primer complete all as specified and directed. |
| 53 | M&L for PCC (1:3:6) type C-1 (using 20 mm gradedstone aggregate) as in cill, step and for inserting hold fast of doors and windowscomplete all as specified and directed. |
| 54 | S&F300mm, Mild steel ordinary rat tailrod pattern springsincluding roller androller platecomplete all as specified and directed. |
| 55 | M&L fortwo coat of oil bound distemper after preparation of new plasteredsurfaces of wall over a coat of primerand including 1mm thick wall care putty completeall as specified and directed. |
| 56 | S&F stainless steel 0.85mm thick Utensil rack / platrack of size 786x760x254mm of standard pattern complete all as specified and directed. |
| 57 | Supply and planting of korean natural carpet grass selection No .1 by dibbling root methodcomplete all as described below and directed .(i) The rates quoted by the contractor shall be deemed to include the cost of following activites , material and labour(a) Prepration of the existing area /field by ploughing in soft /ordinary soil upto the depth of 30 cm and removing all the unsuitable /foreign matrials such as stones, weeds ,trees roots etc by trenchinh method as given in particular specification adn disposal of the rubbish/ foreign material to a distance exceeding 50m but not exceeding 100m all as spfd and directed.(b) Mixing of following fertilizer and manure evenlyt in the soil manually as under :-(i) Matured manure of cow dung or sludge @ .30 Cum/X Sqm(ii) Fine sand : Mixed in that soil on requierd basis as per site requirements (Note: Sand shall be measured & paid for separately as supply only under appropriate items of schedule \"A\" (iii) Neem khali @ 2 kg/X sqm(iv) Bonemeal @ 1 kg/ X sqm(v) D.A.P (16.42) @ .15 Kg /X Sqm (vi) Chloropyriophose(Note : Chloropyriophose shall be measured & paid for separately as supply only under appropriate items of schedule\"A\" ) |
| 58 | Supply and planting of Hedges of Duranta , Lantana , Lalsa and Aclipha, (Min Height 25 cms ) on the prepared formation around the periphari of the areacomplete all asdirected. |
| 59 | Supplying and stacking good earth at site suitable for forming moulds & replacement of suitable soil etc complete all as specified and directed. |
| 60 | Supplying and stacking matured dump manurs at site complete as specified and directed |
| 61 | Supplying and stacking cow dung at site including royalty and carriage complete all as specified and directed. |
| 62 | Supplying and stacking DAP at site complete all as specified and directed. |
| 63 | Supplying and stacking Neem khali at site complete all as specified and directed. |
| 64 | Supplying and stacking Bone meal at site complete all as specified and directed |
| 65 | Supplying and stacking Chloropyriophose at site complete all as directed (Note : Chloropyriophose shall be supplied in small packing upto1 Ltr pack as directed ) Notes for items No 57 to 65above :(i) Rates quoted by the contractor shall be deemed to include the cost of all T& P , transportation charges , loading & infloating , royalties , municipal taxes and other lavies time being enforced .(ii) Laying / spreding /mixing chargesetc shall be deemed to be included in the respective itmes of schedule \"A\" for developments of Area / Site |
| 66 | M&L Surface dressing and site clearance n exc 15 cm deep in any type soil and removal of spoil to distance exc 200m including removal of vegitation , small inequalities trimming of natural ground and prepration of eart surface in proper level for laying turfing of grass lawn complete all as specified and directed. |
| 67 | Spray in earth surface agro based liquid as antitarmite treatment on top of prepared earth surfacecomplete all as specified and directed. |
| 68 | S&F 25mm gun metal globe or gate valve with iron wheel head screwd both ends for iron pipecomplete all as specified and directed. |
| 69 | Supplying and laying ,testingof 25mm boreCPVC pipes of pressure 06kgf/sqcm including all fittings and accessoriesSDR 11 & Plain CPVC SDR 11 fittings in trenchescomplete all as specified and directed. |
| 70 | S&F 15mm bore PVC bib tap make- prayag , including cutting of wall and making good to match the existing surfacecomplete all as specified and directed. |