| 1 | Surface dressing not exceeding 15 cm deep in any type of soil complete all as specified and as directed. |
| 2 | M&L for Cement concrete (1:4:8) Type D-2, (using 40 mm graded crushed stone aggregate), 100 mm thick, as in sub-base and similar works complete all as specified and as directed. |
| 3 | M&L for cement concrete 1:2:4 type B-1,(using 20 mm graded crushed stone aggregate) as incoping on edges etc including weathering slightly rounded or chamfered angles and throating as directed including necessary formwork complete all as specified and as directed. |
| 4 | M & L for 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 5 | Cutting holes in brick walls in built in cement mortar or cement lime mortar exceeding half brick but not exceeding one brick complete alll as specified and as directed. |
| 6 | Cutting chases ,pinning in , making good to facings where required and pointing in cement mortar 1:3 to ends or edges or landings, steps, cills, sunshades,shelves,lintel,etc and cutting in chases for concealed conduit wiring, etc and making good, cutting not exceeding 10 cm girth complete alll as specified and as directed. |
| 7 | Excavation in post holes in hard / dense soils , each not exceeding 0.50 cum, getting out, returning filling in and ramming earth in layers not exceeding 25 cm including watering & removing surplus soil to a distance notexc. 50 m & making good surface complete all as specified and as directed. |
| 8 | M&L for mild steel work in tubular trusses including special shaped washer, cleats etc complete using ERW or induction butt welded tubes confirming to IS: 1161-1979 grade st - 240 complete all as specified and as directed. |
| 9 | M&L for preparation of new steel surfaces of any description , nototherwise described , over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zink chrome primer including, complete all as specified and as directed. |
| 10 | S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 11 | M&L for cement concrete (1:4:8) Type D-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed. |
| 12 | M&L for chequred cement concrete tiles with grey cement and pigment 30cmx30cmx22-25mm thick set and jointed and pointed in cement slurry to match over and including 20 mm thick screed bed in cement mortar 1:6 in floors/path complete all as specified and as directed. |
| 13 | M&L for cement concrete (1:3:6) Type D-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed. |
| 14 | S&F 4 mm thick fibre glass reinforced translucent plain sheeting of any colour and pattern fixed with coach screw and washer inwall , complete as specifed and as directed. |
| 15 | M&L for MS framed work as in doors, gates of angle,fencing post of fe -410 gde E 250 qureed section with gusset plates complete drilled or welded to be prepared for hanging or sliding with and including either hooks and hinges complete as specifed and as directed. |
| 16 | M&L for 2nd class hardwood clean sawn boards or planks, of thickness 40 mm including cutting grooves for rifle stand complete all as specified and as directed. |
| 17 | S&F nails, tacks and screws plain head, lost head, lath, mild steel wire nails, bright finished exc 80 mm but n. exc 150 mm complete all as specified and as directed. |
| 18 | S & F Flat iron as in support and struts in rifle rack including cutting tops to shape as directed , drilling holes notching for wire etc conforming to Fe 410or Fe 310 complete all as specified and as directed. |
| 19 | S&F mild steel work such as in fencing post, tie bars etc including embedding into concrete and making holes for screwing of nut, bolts, cutting top to shape as directed, drilling holes, notching for wire etc confirming Fe 410-0 or Fe 310-0 all as specified and directed. |
| 20 | S & F grade 70 (G 70) heat-treated carbon steel chain chain with a black finish, suitable for use in securing fire arms in rifle rack complete all as specified and as directed. |
| 21 | M&L for preparation of new wooden surfaces of any description not otherwise described over 10 cms width or girth with wood filler transparent liquied including staining with spirit and apply two coat of synthetic varnishcomplete all as specified and as directed. |
| 22 | S&F 10 to 12 mm thick heavy duty full body heavy duty vitrified tiles of any colour, any pattern any desing as approved by GE, area of each tile exceeding 0.04 Sqm but not exceeding 0.36 Sqm as in floors/landing/steps/riser/parking/footpath etc and over & including 15 mm thick screed bed or bedding/rendering layer in cement mortar 1:4, including jointed with neat cement slurry and pointed in coloured cement to match the surface of tiles complete all as specified and as directed. |
| 23 | S&Ffor 11 to 15 mm mild steel screws bolts (machine made) with hexagonal or square heads at one end and screws both ends each screwed end to be fitted with washers and one hexagonal or square nut exc 5cm not exc 10 cm long complete all as specified and as directed. |
| 24 | S&F framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plate, riveting, etc n.exc 10 kg each brackets, conforming to Fe-290. Gde E-165 complete all as specified and as directed. |
| 25 | M&L for chipping out spilled and loose concrete cover and derusting steel reinforcement of concrete column, beam, slab, chajjas, parapets and the like as directed up to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforcement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guniting mix using one part of OPC 53 grade and two part ofsand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guiniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out up to 10 metre height) complete as directed at siteNote :- (a) After placing the additional reinforcement all concrete surfaces shall be thoroughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction. (b) when polymix concreting in taking condition,guiniting is done with polycrete admixture @ 2% by weight of cement all as per manufacturers instructions (polycrete admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer).(c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account. |
| 26 | M&L for dubbing out 25mm thick in cement mortar 1:4 on irregular surface of brick or concreteincluding taking down loose concrete and scaffolding arrangement to carry out the work complete all as specified and as directed. |
| 27 | M&L for GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste including scaffolding arrangement to carry out the work complete all as specified and as directed. |
| 28 | Demolition of RCC of any description, in any position roofs, floors (other than ground floors), beams staircases, landing, chajjas, facia RCC overhead tank and similar suspended work and removing debris obtained from demoliton exc. 1.50 km but n exc.5 km outside of MD landcomplete all as specified and as directed. |
| 29 | S&F factory made Fibreglass Reinforced Plastics (FRP) Chajjas of 450mm wide and 4mm thick of Fibrewasys or equivalent in required colour, size, design made by RTM machine technology, resulting in void free compact laminate in single piece, having smooth graddual slope curvature for easy drainage of water and duly reinforced by 2 nos, vertically and 1 nos horizontally 50X2mm thick MS flat with 12mm in built hole for grouting on the existing walll along with the 50mm flanges duly inserted and sealed in the wall complete in one single piece casted monolithically including all necessary fittings.The FRP chajja should be manufactured using unsaturated polyster resin as per IS-6746 duly reinforced with fibreglass chopped strand mat (CSM) as per IS-11551 complete with protective Gelcot U/V coating on top for complete resistance from the extreme of temperature, weather and sunlight complete all as specified and as directed. |
| 30 | Demolition of brick work built in cement mortar including all quions, pillars, ashlar facings, dressed stone work and precast articles etc. complete all specified and as directed. |
| 31 | M&L Brick work with sub class \"B\" bricks , straight or curved on in half brick thick wallbuilt in cement mortar (1:4),(up to two story bldgs) complete all specified and as directed. |
| 32 | M&L for rendeing 15 mm thick with ready mix plaster on brick/stone masonary surface other then fair faces surfacesfinished even and smooth without using extra cement including taking down existing cement plaster including scaffolding arrangement to carry out the work complete all as specified & directed. |
| 33 | M &L for applying a bond coat of Latex:Water:cement - 1:4:6consumption @100gm/sqm on the brick wall surface by brush as per manufacturer\"s recommendations including curing complete all as specified and as directed. |
| 34 | M & L for Expose the first joint of masonry structure at ground level horizontally. The plaster must be knocked off at least 50 cm beyond the visibly penetrated area. Damaged mortar joints are to be scraped out to a depth of approximately 2-3 cm. Drilling Holes : Drilling holes 10mm diameter in masonary structure along the side of the joint as per manufacturer\"s instructions so as to cross the brick/ block at the intervals spacing of 15-30cm depending on extent of rising dampness as per recommendation of engineer in charge.Cleaning of holes : Clean the holes by air blower prior to fixing nozzles. Install latex polymer packer injection packers9.8mm diameter, 10cm long in the holes and tighten. Fix the packer securely using sealent.Cutting of Packers : Cut the packers after completion of grouting without damaging structural elements. |
| 35 | Supply and apply of a 3 part, very low viscous, elastic polyacrylic injection resin with a versatile and adjustable reaction time having Mixed viscosity : 3-11 M.pa.s at +20 Deg C, Reaction time : adjustable according to ambient temperatrure and execution requirement between 8-50 mins, pH – 9-10, tested as per Wissbau No. 2002-094-(1A) – Function test with re-injectible hose system. The holes should be drilled until a depth of approx 5 cm (for a 6cm thick wall) before the end of the wall is reached. Pump injcection of polymer resin compound at >20 bar into or behind fissures or into masonry joint which are allowing water to infiltrate into unwanted areas. If voids in masonry being injected contain insufficient moisture to activate the grout inject a small amount of water prior to injecting the grout. When movement stops or polymer compound appears at the packer move to the next packer and inject. If the dampness is heavy, inject similarly at next joint line |
| 36 | M&L preparation of new plaster surfaces of wall and applying water proof wall care putty 1 mm thickness over plaster surfaces to prepare the surfaces even and smooth and finishing walls with acrylic smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer @ applied @ 2.20 Kg/10Sqm) complete all as specified and as directed. |
| 37 | M&L for complete removal of existing treatment from from external surfaces of walls by electrically operated grinder, washing and filling of holes with filler material and applying 1-2mm thick cement base wall care putty on the whole surface to achieve smooth, even & uniform surface including grinding with sand paper and levelling of surface and applying two coats of acrylic smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm, complete all as specified and directed.Note: (a) All works shall be done mechanically through authorised applicator only.(b) Authorised applicator of paint manufacture shall have valid authrisation letter from the manufacturer (minimum regional HQs) issued not earlier than 30 days from start date of the said finishing work.(c) The contractor shall provide application for testing and certification of finishes by paint manufacturing firm/ their authorised applicator. (d) Cost of all above aspects shall be deemed to be included in quoted rate of the contractor |
| 38 | S&F 10 to 12mm thick heavy duty ceramic floor tiles of any colour, any pattern any desing as approved by GE, area of each tilenot exceeding 0.36 Sqm as in floors/landing/steps/riser/parking/footpath etc and over & including 15mm thick screed bed or bedding/rendering layer in cement mortar 1:4, including jointed with neat cement slurry and pointed in coloured cement to match the surface of tiles including dismantling of existing tiles of any description complete all as specified and as directed. |
| 39 | Fixing only chain link fencing including line wires, any mesh size and type and type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and as directed. |
| 40 | Supply only MS galvanished chain link fencing with 3.80 mm dia wire and aperature size 50 mm x 50 mmincluding line wires including strain bolts, binding wire etc complete all as specified and as directed. |
| 41 | M&L for mild steel Round bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding complete all as specified and as directed. |
| 42 | Excavation in trenches in any type of soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out for laying of cables complete all as specified and as directed. |
| 43 | Returning filling in including spreading, levelling watering and well ramming in layers not exceeding 25 cm each layers, complete all as specified and as directed. |
| 44 | Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above starting point complete all as specified and as directed. |
| 45 | M&L for reinforced cement concrete M-25 Design mix as in footing, foundation,beams, plinth beams, base for columns and mass concreteetc complete all as specifiedand as directed. |
| 46 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter for rough finished surface of concrete, complete all as specified and as directed. |
| 47 | M&L for reinforced cement concrete M-25 (Design Mix) as in columns and pillars etc complete all as specifiedand as directed. |
| 48 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions of square, rectangular or polygonal shape for fair finished surface of concrete, complete all as specified and as directed. |
| 49 | M&L for providing reinforcement cement concrete M-25 (Design Mix) as in Beams, cantilevers, ressummers, lintels over 1.5m span concreteetc complete all as specifiedand as directed. |
| 50 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished surface of concrete, complete all as specified and as directed. |
| 51 | M&L for mild steel TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including muld seel wire (annealed) not less than 0.9mm dia, complete all as specified and as directed. |
| 52 | All as per item no 51.00 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, complete all as specified and as directed. |
| 53 | Material & labour for brick work with sub class B old size burnt bricks straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 complete all as specifie and as directed. |
| 54 | M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces with cement mortar 1:4 without using extra cement complete all as specifed and as directed. |
| 55 | S&F factory Made 18mm WPC Railing combining WPC board & WPC frame thick 100% Solid WPC ( Wood polymer Composite ) Railing of required length and of 2\"-2.5\" height, comprising ofvirgin PVC resin of K Value 58-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from single Extrusion process, WPC foam board with having minimum density 650 kg/cbm and WPC framewith having minimum density 780 kg/cbm ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant.For WPC Railing WPC Jali to be fixed with wpc frame of size 75x50mm with necessary supporting lengths at verticle as well as horizontal. At wall frames to be fixed with 3\"x3\" GI \"L\" or S.S cleats to support vetically frame lengths Coplete all as specified and as directed. |
| 56 | S&F factory made 100% Solid WPC ( Wood Polymer Composite ) - Door Frame 75mm x 50 mm ( Moulded ) Single Rebated, made from Wood Polymer Composite ( Single Extruded Process ) material comprising of virgin PVC polymer of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and Natural Fibers ( Wood Powder/ Rice Husk/ Wheat Husk ) and Non toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full body treaded star headed screws having minimum frame density of 780 kg/ cbm an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of ( Min.990 N ), Minimum Compressive Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof , water / Moisture Proof & Fire retardant & Fixed in position with SS Dash Fasteners / Hold Fast of required dia and lenght, all as per specifications drawings as directed by the Engineer-In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company complete all as specified and as directed. |
| 57 | M&L for preparation of newly plasered surfaces of walls and applying two coat of cement based paint over a coat of alkali resistant primer, complete all as specified and directed by engineer-in-charge. |
| 58 | M&L for hardcore of gauge not exceeding 63 mm deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface for plinth protection/path complete all as specified and as directed. |
| 59 | M & L for moorum/red bajri filling Spreading and levelling in layers n exc 25 cm thick, well ramming including watering and consolidation complete all as specified and as directed. |
| 60 | M&L for 60 mm thick, M-35 grade machine pressed precast concrete interlocking paver block of any colour, any shape and size confirming to IS 15658-2006, laid over and including 50 mm laid sand cusioning complete all as specified and as directed. |
| 61 | M&L for providing cementconcrete 1:3:6 type C-1 1:3:6 (using 20 mm graded crushed stone aggregate) as in roof kerbs or mud stops; rounded or chamfered on edges complete all as specified and as directed. |