| Sl. No. | Item Description |
| 1 | Disconnecting of electrical connection from the panel board, and starter of submersible/ centrifugal/ monoblock/ open well submersible pumping set of any model / make size 3 HP to 100 HP capacity and removing the pipe line connection from discharge side and taking out unserviceable pump set along with column pipe from bore well with the help of chain pully block including transportation to workshop and back after repair and lowering of same in pumping bore well including replacement of rusted nuts bolts rubber gasket etc to make it fully functional, testing complete all as specified and as directed. |
| 2 | Opening the submersible/open well submersible pump set of capacity 3 to 25 HP including taking down/out the burnt winding wire cleaning the slots, rewinding the motor with super enamelled copper winding wire of existing gauge, weight etc, repairing the same by replacing the unserviceable parts including machine/ lathe work and re-assembling the pump set in original position with required insulating material to make it fully functional complete all as specified and as directed.Note:- Winding & Copper wire cost will be measured and paid under item no.3 here in after. |
| 3 | Supplying and assembling super enamelled copper winding wire of appropriate/ existing suitable gauge and weight suitable up to 20HP pumping sets complete all as specified and as directed.Note:- Winding labour charges included in the quoted rate. |
| 4 | S & F G M Bearing bush capacity 2 to 20 HP submersible/ open well submersible pump set after taking down/ out bush as existing at site complete all as specified ans as directed. |
| 5 | Supply only following parts for submersible pump set of capacity 2 HP to 20HP complete all as specified and as directed. |
| 6 | Water seal and cable seal |
| 7 | Thrust bearing segment |
| 8 | CI housing |
| 9 | Rotar sleeve turning and grinding |
| 10 | Stainless Steel coupling |
| 11 | Balancing of Rotar |
| 12 | CI Suction chamber |
| 13 | G.M Impeller |
| 14 | EPV Impeller |
| 15 | EPV Stage bowl |
| 16 | Remetling of G.M Impeller and turning |
| 17 | Stainless Steel Distance sleeve |
| 18 | Pump sand guard |
| 19 | M & L for painting of submersible pump set of size 2 HP to 20 HP with two coat of synthetic enamelled paint over coat of red oxide primer complete all as specified and as directed. |
| 20 | M & L for replacement of heavy duty GI nipple 200 mm long and 80 mm bore with flange welded on both ends complete all as specified and as directed. |
| 21 | M & L for replacement of heavy duty GI nipple 200 mm long and 50 mm bore with flange welded on both ends complete all as specified and as directed. |
| 22 | S & F water proof submersible cable flat 3 core copper conductor, PVC insulated 1100 volts grade, protected by means of metal clip alongwith the pump body and connected to pump motor through water tight sealing joints including taking out old unserviceable submersible cable of the following sizes complete all as specified and as directed:-Make:- Finolex/ Polycab/ Havells |
| 23 | 1.5 Sqmm |
| 24 | 2.5 Sqmm |
| 25 | 4 Sqmm |
| 26 | 6 sqmm |
| 27 | Labour only to remove submersible pump set upto 10 HP capacity from dry/ dead borewell including removal of column pipes/cables and transportaion charges, to kept in MES store yard complete all as specified and as directed |
| 28 | S & F GI Pipe column pipe heavy grade, 80 mm bore 3 mtrs long coupled with heavy grade suitable size of MS flanges 16mm thick duly welded on both sides as directed including necessary nut and bolts with washers & rubber packing required at site condition and lowered in to the bore well including taking out old unserviceable Column pipe complete all as specified and as directed (length of each column pipe shall be 3 Mtrs)Note:- taking out and Lowering of Submersible pump set shall be measured and paid under respective item. |
| 29 | All as per Sr item No.11 here in before but size of pipe 50mm bore |
| 30 | S & F MS clamp in MS flat 50mm x 6mm with two Nos of MS nut & bolts for 50mm dia column pipe |
| 31 | S & F MS clamp in MS flat 80mm x 6mm with two Nos of MS nut & blots for 80mm dia column pipe |
| 32 | S & F well capacity suitable for 200 / 250 mm bore pipe consisting of two parts complete with welding and machinery work having provision of cut out for passing of column pipe and fabricated out of mild steel sheet 3.15 mm thick complete all as specified and as directed |
| 33 | Drilling 250 mm (10\") bore hole by DTH type method at any depth below soil / rock including disposal of surplus soil to a distance n.exc. 50 mtr complete all as specified and as directed.Note:-(i) The depth of drilling bore shall be upto water table and will be directed by E-in-C. (ii) The rates quoted in above items srl No 15 is deemed to be inclusive of all T&P eqpts and labour required for execution of this item at site including trasportation charge for the said T&P equipments and no extra cost shall be paid for the same. |
| 34 | Supplying, laying, jointing, welding & testing MS Pipe of size 200 mm (Heavy duty class \"C\") 8 mm thick laid in trenches for complete all as specified and as directed. |
| 35 | Supplying, laying, jointing, welding & testing MS Pipe of size 200 mm (Heavy duty class \"C\") 8 mm thick laid in trenches or on floors having 3mm slots in 2.44 to 3.85 mtr length for complete all as specified and as directed. |
| 36 | Supply and packing pea gravel of size 3mm to 6 mm around casing/ housing pipe complete all as specified and as directed. |
| 37 | M & L for brick work with sub class \"B\" bricks straight or curved on plan exc 6M mean radius built in CM (1:4) complete all as specified and as directed. |
| 38 | M & L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation, flooring sub base complete all as specified and as directed. |
| 39 | Transportation of air compressor with tools and accessories at different location in Chennai cantt area for devlopment of borewell complete all as specified and as directed. |
| 40 | Development of bore well, if any capacity size, not more than 160mtrs deep, at the pressure not less than 6 Kg/ Sqcm by diesel engine driven air compressor of capacity 630 cfm with & including air pipe and connected items to achieve the minimum yield of 3 litres per second of tube well complete all as specified and as directed. |
| 41 | S & F in replacement of mild steel nuts, bolts & washers etc of any size complete all as specified and as directed. |
| 42 | S & F in replacement of rubber packing suitable for flange 50mm dia complete all as specified and as directed. |
| 43 | S & F in replacement of rubber packing suitable for flange 80mm dia complete all as specified and as directed. |
| 44 | S & F in replacement of rubber packing suitable for flange 100mm dia complete all as specified and as directed. |
| 45 | S & F in replacement Amp meter as per existing model up to 50 Amps complete all as specified and as directed. |
| 46 | S & F in replacement Volt meter as per existing model up to 50 Amps complete all as specified and as directed. |
| 47 | Taking down old unserviceable any type of starter any size and S & F new ML 1.5 FASD with ML relay range 13-21 Amps including stainless steel box copper lugs existing starter panel complete all as specified and as directed. |
| 48 | Taking down old unserviceable any type of starter any size and S & F new ML 2 FASD with ML relay range 20 - 32 Amps including stainless steel box copper lugs existing starter panel complete all as specified and as directed. |
| 49 | S & F power contactor MNX-18, 32 Amps, 240 volts, 50 HZ including NON Nozzle suitable for fixing in existing panel after taking down/out contactor as existing at site complete all as specified and as directed. |
| 50 | S & F power contactor MNX-25, 45 Amps, 240 volts, 50 HZ including NON Nozzle suitable for fixing in existing panel after taking down/out contactor as existing at site complete all as specified and as directed. |
| 51 | S & F power contactor MNX-32, 55 Amps, 240 volts, 50 HZ including NON Nozzle suitable for fixing in existing panel after taking down/out contactor as existing at site complete all as specified and as directed. |
| 52 | S & F power contactor MNX-40, 55 Amps, 240 volts, 50 HZ NO-N Nozzle suitable for fixing in existing panel after taking down/out contactor as existing at site complete all as specified and as directed. |
| 53 | Supplying and fixing, MS flanges of 100 mm bore not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and as directed. |
| 54 | Supplying and fixing, MS flanges of 150 mm bore not less than 16mm thick duly welded on ends of MS pipe complete all as specified and as directed. |
| 55 | Supplying and fixing, MS flanges of 80 mm bore not less than 16mm thick duly welded on ends of MS pipe complete all as specified and as directed. |
| 56 | Taking down the unserviceable terminal block any type and S & F new one terminal block 100A - 3 way (For MU-G30/50) complete all as specified and as directed. |
| 57 | Taking down old unserviceable relays and S & F new thermal over load relays fixing at existing site as per following complete all as specified and as directed. |
| 58 | ML 1.5 relay range 6-10 Amp |
| 59 | ML 1.5 relay range 10-16 Amp |
| 60 | ML -2/3 relay range 9-14 Amp |
| 61 | ML-2/3 relay range 13-21 Amp |
| 62 | ML-2/3 relay range 14-23 Amp |
| 63 | S & F single phase preventor, type VSP-II after taking down/out preventor as existing at site complete all as specified and as directed.Make:- Minilec /SINETRAC/ LEGRAND/ Siemens/ ABB/L&T |
| 64 | S & F submersible pump controller starter in sheet metal enclosure with volt meter and ampere meter, motor rating 415 Volts, 3 phase, 50 Hz for 4.5 KW motor, Model No MU-G6, after taking down/ out breaker as existing at site complete all as specified and as directed. |
| 65 | S & F MCB 6-32 amps, 230 volts \"C\" series single pole in the existing MCB DB including removing existing unserviceable MCB\"s complete all as specified and as directed. |
| 66 | S & F MCB 4 pole 63 Amps, 415 volts TPN in the existing MCB DB including removing existing unserviceable MCB\"s complete all as specified and as directed. |
| 67 | S & F in repairs MCCB 63 Amps 25 KA, 3 Pole inlcuding studs in existing LT panel fixing complete all as specified and as directed. |
| 68 | S & F in repairs MCCB 100 Amps 25 KA, 3 Pole inlucding studs in existing LT panel fixing complete all as specified and as directed. |
| 69 | S & F in repairs MCCB 125 Amps 25 KA, 3 Pole inlucding studs in existing LT panel fixing complete all as specified and as directed. |
| 70 | S & F in repair Automatic Phase Sequence Corrector suitable for 5-15 HP with sheet metal encloser and indicator lamp output / inpurt, suitable for 3 phase electric motor with automatically protection against single phasing voltage, unbalanced and low / high voltage with time delay complete all as specified and as directed. |
| 71 | S & F direct on line starters in sheet steel enclosure type MN/ ML (motor rating AC-3 duty, 415V, 50 Hz, 3 Phase up to 10 HP including taking down old unserviceable starter complete all as specified and as directed. |
| 72 | S & F electronic Timers Type ST 100 240/360/415 V, 50 Hz for 3-30 secs [9107] including taking down old unserviceable any type timer complete all as specified and as directed. |
| 73 | Opening the centrifugal pump of capacity 7.5 to 100 HP, repairing the same by replacing the unserviceable spare parts including machining work and re-assembling the same in original position complete all as specified and as directed.Note:- Spare Parts required shall be measured & paid spaerately. |
| 74 | S & F in repair of following spare parts for Centrifugal pump of 7.5 to 100 HP capacity complete all as specified and as directed. |
| 75 | CI Impeller |
| 76 | Pump shaft SS (AISI-410) |
| 77 | CI Casing wearing (Neck ring) |
| 78 | CI interstage ring |
| 79 | CI stuffing box bush |
| 80 | CI Gland Plate |
| 81 | Eye bolt with nut |
| 82 | CI Shaft sleeve |
| 83 | Gasket Packing Set |
| 84 | Gland packing (champion) |
| 85 | Impeller key |
| 86 | coupling key |
| 87 | CI bearing cartridge DE/NDE |
| 88 | CI bearing plate |
| 89 | Coupling nut |
| 90 | MS Stud with nut |
| 91 | Labour only for Remetling of pump shaft, turning and balancing |
| 92 | Supply only in replacement of water seal/ Oil seal for any size of pump. |
| 93 | Supply only in replacement of O ring set for any size of pump |
| 94 | S & F in repair copper terminals lugs ring type medium duty for following items complete all as specified and as directed:- |
| 95 | 16 mm |
| 96 | 25 mm |
| 97 | 35 mm |
| 98 | S & F in repair of bimetal over load relay type ML 2/3, relay range 20-32 Amps complete all as specified and as directed.Make:- L&T or equivalent in Seimens/ BCH/ ABB/ Schneider. |
| 99 | S & F in repair of Bimetal over load relay type MN 2, relay range 14-23 Amp complete all as specified and as directed.Make:- L&T or equivalent in Seimens/ BCH/ ABB/ Schneider. |
| 100 | S & F spare tyre for coupling type as under, after taking down/out as existing at site of capacity 5 to 15 HP complete all as specified and as directed.Make:- Unique or equivalent as approved. |
| 101 | type TC/P/013 |
| 102 | type TC/P/014 |
| 103 | S & F in replacement of double ball bearing of existing size of capacity 7.5 to 100 HP complete all as specified and as directed. |
| 104 | S & F in replacement MS base channel of size as exists including cutting, welding and making hole including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 105 | M & L for fixing in repair following sizes 3 pole power contactor any type complete all as specified and as directed. |
| 106 | ML 1.5, 16 to 25 Amps |
| 107 | ML 2, 30 to 32 Amps |
| 108 | Comprehensive maintenance and repair of pressure feed / Booster type gas chloronome plants up to the capacity of 200 gms per hour (of any existing make at site) complete with all other accessories.Note:-(i) Spare parts for chloronome plant shall be measured and paid separately. (ii) Cost of minor spare items/parts which are not covered in Sch \"A\" but are necessary for the satisfactory functioning of the plant shall be deemed to be included in the rate quoted for this item. (iii) Labour charges for removal and fixing of spares and repair woks shall be deemed to be included in the rate quoted for this item. |
| 109 | Supply only following spares/parts of chloronome plants of capacity of 200 gms per hour.Note:- The make shall be suitable for the existing make available at site. |
| 110 | Mixing chamber including with inner fittings |
| 111 | Primary filter heavy duty |
| 112 | Secondary filter heavy duty |
| 113 | Solutionizer |
| 114 | Diaphragm type pressure gauge |
| 115 | PVC heavy duty Gas Bend |
| 116 | Brass chlorine cylinder connecting valve heavy duty with nickel coated including lead washers complete all as specified and as directed.Make:- TECHNO ISI marked or equivalent. |
| 117 | Chlorine gas filter element |
| 118 | Chlorine pressure indicator |
| 119 | Vacuum line- hose pipe |
| 120 | Union \"O\" rings, rubber washer |
| 121 | Chlorine solution outlet valve |
| 122 | Chlorine vacuum isolation valve |
| 123 | Chlorine Vacuum Indicator |
| 124 | Chlorinator Injector assembly |
| 125 | Spare Nozzle for Injector |
| 126 | Water Pressure Indicator - SS |
| 127 | Water Line valve |
| 128 | Comprehensive maintenance and repair of hydro chloride liquid electronic automatic dosing equipment 100 ltr capacity of any type and any make complete all other accessories required. Note:-(i) Spare parts for chloronome plant shall be measured and paid separately. (ii) Cost of spare items/parts which are not covered in Sch \"A\" but are necessary for the satisfactory functioning of the plant shall be deemed to be included in the rate quoted for this item.(iii) Labour charges for removal and fixing of spares and repair woks shall be deemed to be included in the rate quoted for this item. |
| 129 | Supply only following spares parts of Electronic dosing equipments of 100 ltr capacity.Note:- The make shall be suitable for the existing make available at site. |
| 130 | HDPE tubing 6 mm dia. |
| 131 | Non return valve assembly. |
| 132 | Foot valve. |
| 133 | Teflon ring seal. |
| 134 | Ceramic Ball. |
| 135 | Injection valve with NRV. |
| 136 | Nylon red ring washers. |
| 137 | Removing / replacement of unserviceable heavy duty HDPE dry container tamper proof of capacity 35 Ltrs and taking unserviceable container as a credit to the contractor complete all as specified and as directed. |
| 138 | Repairing, leak testing with Hydrochloric pressure with and including transporting charges to testing centre from GE STM including replacing cylinder connecting valve of Techno make, painting complete with two coats of synthetic enamel paint with test certificate complete all as specified and as directed. |
| 139 | S & F in repair FRP chemical tank 100 ltrs capacity with lid. |
| 140 | Painting to chlorine gas cylinder externally with one coat of synthetic enamel paint of yellow colour after preparation of surface by removing old paint by paint remover/scrappers and writing the SER No of cylinder and formation name in black paint complete all as specified and as directed. |
| 141 | S & F single core copper conductor, PVC insulated 1100 volts grade, protected by means of metal clip alongwith the pump body and connected to pump motor through water tight sealing joints including taking out old unserviceable cable complete all as specified and as directed of the following sizes:- |
| 142 | 16 Sqmm |
| 143 | 25 Sqmm |
| 144 | 35 Sqmm |
| 145 | Supply and filling Multipurpose Grease lubricant for Motors & Pumps complete all as specified and as directed.Note:-(i) If the contractor fails to repair the motor and pump within the five days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost.(ii) This shall be in addition to penalty as mentioned in clause of particular specification.(iii) The decision of the Accepting officer in this regard shall be final concluding and binding on the contractor. |
| 146 | Cleaning of OTA, Old Swimming Pool of size 25m x 13.5m before operation using Eco friendly harmless to human beings cleaning material and suitable methods to make the pool water crystal clear bottom of the pool and transperant water all the time before filling as required at site complete all as specified and as directed. |
| 147 | Cleaning of OTA, New Swimming Pool of size 50m x 21m before operation using Eco friendly harmless to human beings cleaning material and suitable methods to make the pool water crystal clear bottom of the pool and transperant water all the time before filling as required at site complete all as specified and as directed. |
| 148 | Cleaning of OTA, New Deep Diving Pool of size 16m x 16m before operation using Eco friendly harmless to human beings cleaning material and suitable methods to make the pool water crystal clear bottom of the pool and transperant water all the time before filling as required at site complete all as specified and as directed. |
| 149 | Note For item Ser No.70 to 72:-Quoted rates shall include for manpower and cleaning material, safety gears and ladders etc required at site for filling up the swimming pools with water. |
| 150 | Cleaning of OTA, New Swimming Pool of size 50 m x 21 m after completion of operation including complete drain out of pool with the help of required capacity submersible monoblock pumpset and dry with using cotton cloth as well as complete drain out of filtertion plant and make the plant room neat & clean complete all as specified and as directed. |
| 151 | Cleaning of OTA, New Swimming Pool Deep Diving Pool of size 16 m x 16 m after completion of operation including complete drain out of pool with the help of required capacity submersible monoblock pump set and dry with using cotton cloth as well as complete drain out of filtertion plant and make the plant room neat & clean complete all as specified and as directed. |
| 152 | Cleaning of OTA, Old swimming Pool of size 25 m x 13.5 m after completion of operation including complete drain out of pool with the help of required capacity submersible monoblock pumpset and dry with using cotton cloth as well as complete drain out of filtertion plant and make the plant room neat & clean complete all as specified and as directed. |
| 153 | Note For item Ser No.73 to 75:- Quoted rates shall include for manpower and required cleaning material,safety gears and ladders etc required at site for drain out the swimming pools de-watering on completion of Operation and Maintenance of swimming pools. |
| 154 | S & F in replacement Butterfly valves including with jointing materials, rubber gaskets, old worn out nut-bolts, washers etc of following size complete all as specified and as directed. |
| 155 | 100 mm dia valve |
| 156 | 150 mm dia valve |
| 157 | Supply, fixing, jointing and testing in replacement of Cast Iron Sluice Valve of sizes as under ISI Marked , flanged ends drilled pressure rating PN-1.6 PD Short body, confirming to IS 14846-2000 having stainless steel spindle with cast iron operation wheel at top including taking out unserviceable Sluice Valve of following sizes complete all as specified and as directed:-Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. |
| 158 | 100 mm bore Sluice Valve |
| 159 | 150 mm bore Sluice Valve |
| 160 | Disconnecting of electrical connection from the panel board, and starter of monoblock pumping set of any model / make size 15 HP to 30 HP capacity and removing the pipe line connection from discharge side and taking out unserviceable pump set along with column pipe from bore well with the help of chain pully block including transportation to workshop and back after repair and lowering of same pumping bore well including replacement of rusted nuts bolts rubber gasket etc to make it fully functional, testing complete all as specified and as directed. |
| 161 | Taking down/out including opening of Compressor upto 7.5 HP at site, carrying out the servicing, greasing, topping up compressor oil of the suitable grade, cleaning of Air filter, replacement of filter element, replacement of suitable size and suitable make bearings, fan belts of same type including suitable size SS nuts, bolts and washers etc and other repairs of minor nature, applying two coats of synthetic enamel paint of existing colour or as directed over a coat of red oxide primer, checking and starting and testing complete pump set for satisfactory pump set complete all as specified and as directed. |
| 162 | M & L for painting on steel and iron surfaces on the pool operating equipments and pipe line, filteration plants, pumps and motors with two coat of synthetic enamel paint over a coat of red oxide primer as per existing colour scheme or pattern after preparation of old painted surface of any description over 10 cm in width or girth complete all as specified and as directed.NOTE:-Old paint from the structures/pipes will be scrapped off completely and the surface will be smoothen with water Emery paper.Painting over pump and motors will be measured as 1sqm for each pump & Motor on the same base frame. |
| 163 | M & L for fabrication in replacement of rusted base frame with MS Channel MC-25/50/75/100/125 for foundation of centrifugal pump sets including one coat of red oxide and two coat of black enamel paint and inclduing taking out of old base frame and grouting new frame in the existing grouted bolts and nuts, complete all as specified and as directed. Note:- The contractor will make sure that the frame fixed is leveled and both pump and motor are fully alligned to work smoothly. |
| 164 | Supply and laying in replacement of MS Pipes Heavy grade with all fittings as required at site laid in floors or fixed to walls and ceilings including welding as required at site and removing old rusted pipe of following bore complete all as specified and as directed. |
| 165 | 80 mm bore |
| 166 | 100 mm bore |
| 167 | 150 mm bore |
| 168 | 200 mm bore |
| 169 | S & F CI foot valve of below items rating PN 1.0 flanged ends, swing type operation with rubber sheet, as per IS:4038 including taking out unserviceable foot valve complete all as specified and as directed.Note:- (Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item) |
| 170 | 150 mm bore |
| 171 | 200 mm bore |
| 172 | Supply and charging (filling in) in replacement of old worn out/ uncleaned/ choked filter media in filtration cum recycle plant sutiable for swimming pool approx 5900 kg/ filtration plant to maintain filter flow rate 111 M3/ Hr as recommended by manufactuere and swimming pool norms following Filter media details complete all as specified and as directed:- |
| 173 | Total Media Depth – 1400mm.(i) Quartz Pebbles of 1\" – 3/4\" size Not less then 100 mm thick layer.(ii) Quartz Pebbles of 3/4\" to 1/2\" size Not less then 100 mm thick layer.(iii) Quartz Pebbles of 1/2\" to 1/4\" size Not less then 100 mm thick layer.(iv) Quartz Pebbles of 1/4\" to 1/10\" size Not less then 100 mm thick layer.(v) Quart sand of assorted sizes Not less than 900mm thick layer.(vi) Making Back wash arrangement functional/repair – Back wash arrangement shall be made through the running water hence arrangement shall be made to facilitate the back washing system. (vii) Replacement of Pressure gauges and flow meters from all Filtration plants – 02 Nos of suitable rating.(viii) Repair and replacement of Air release pipe and valve from all filteration plants. |
| 174 | Opening the Monoblock pump set of capacity 15 HP to 30 HP including taking down/out the burnt winding wire cleaning the slots, rewinding the motor with super enamelled copper winding wire of existing gauge, weight etc, repairing the same by replacing the unserviceable parts including machine/ lathe work and re-assembling the pump set in original position with required insulating material to make it fully functional complete all as specified and as directed. |
| 175 | Supplying and assembling super enamelled copper winding wire of appropriate/ existing suitable gauge and weight suitable up to 30HP pumping sets complete all as specified and as directed. |
| 176 | S & F in replacement of stainless steel ladder suitable for existing size complete all as specified and as directed. |
| 177 | S & F Fibre moulded Floating ball for suction hose of suction sweeper unit complete all as specified and as directed. |
| 178 | Supply and replacement of heavy grade PVC flexible braided hose of 50 mm dia complete all as specified and as directed. |
| 179 | S & F 600mm long heavy duty groomed straight stainless steel wire brush in plastic body for a swimming pool cleaning purpose complete all as specified and as directed. |
| 180 | S & F of heavy duty suction sweeper brush suitable for 5 HP suction head complete all as specified and as directed. |
| 181 | S & F for telescopic handle of aluminium of 12 feet length suitable to mount leaf net for swimming pool purpose including taking down old unserviceable all as directed. |
| 182 | Repairs to suction sweeper head assembly oiling, greasing, overhauling including replacement of broken wheels having 5 HP motor complete servicing and painting complete all as specified and as directed. |
| 183 | S & F of unplasticized PVC pipe of size 15mm dia bore including all UPVC fittings like bend, elbow complete all as specified and as directed. |
| 184 | Repairing, leak testing with Hydrochloric pressure with and including transporting charges to testing centre from GE STM including replacing cylinder connecting valve of Techno make, painting complete with two coats of synthetic enamel paint with test certificate complete all as specified and as directed. |
| 185 | Testing of drinking water collected from local source (bore wells/ shallow wells in the area of AGE (E/M), Mount and submission of detailed test report to the office of Engr-in-Charge.(i) Carrying out minimum essential testing of water as per IS 10500-2012 mandatory for chemical colour, odour, taste, turbidity, PH value, TDS total hardness, iron, chloride, fluoride and residual free chlorine and Bacteriological total coliform organisms per 100 ml (MPN) and E Coli in 100 ml) with specific recommendation regarding suitability of water for drinking purposes. (ii) Collection of water from different sources of water ie. Sump, bore wells & shallow well in a sterilized bottle and testing in NABL Approved laboratory as mentioned in specification. Note:- Rate Quoted shall also deemed to be included for the followings:-(i) Cost of sterilized bottle as required. (ii) To and fro transportation charges for collection of samples from source (sump, bore & shallow wells) |
| 186 | S & F single core round copper conductor, PVC insulated 1100 volts grade, protected by means of metal clip alongwith the pump body and connected to pump motor through water tight sealing joints including taking out old unserviceable cable of the following sizes complete all as specified and as directed:- |
| 187 | 10 Sqmm 3 core |
| 188 | 16 Sqmm 3 core |
| 189 | S & F in repair star delta starter of capacity upto 30 HP starter in sheet metal enclosure with volt meter and ampere meter, motor rating 415 Volts, 3 phase, 50 Hz for as existing at site complete all as specified and as directed. |
| 190 | S & F in repair DOL (direct on line starter) of capacity upto 7.5 HP starter in sheet metal enclosure motor rating 415 Volts, 3 phase, 50 Hz for as existing at site complete all as specified and as directed. |
| 191 | Supply only Orthotolidine reagent solution 500 ml bottle for free chlorine testing complete all as specified and as directed. |
| 192 | Supply only crystal alum for swimming pool / pump house water crystallization purpose complete all as specified and as directed. |
| 193 | Supply only Hydro chloric acid in PVC container for swimming pool cleaning purpose complete all as specified and as directed. |
| 194 | Supply only Ammonia Liquid 500 ml Bottle complete all as specified and as directed. |
| 195 | Supply only Calcium based granular high strength disinfectant chlorinating chemical having 60% to 65% concentration for treatment of drinking water/ swimming pool water/ STP complete all as specified and as directed. |
| 196 | Supply only calcium hypochlorite (Bleaching powder) in air tight bags complete all as specified and as directed. |
| 197 | Supply only liquid chlorine gas duly filled in contractor cylinder 100 Kg capacity, including with testing, labour, handling, filling charges and transportation of cylinder from site to filling point and re-installed at the same complete all as specified and as directed. |
| 198 | Supply only Sodium Hypo chloride NaOCl (Grade-I) containing available chlorine content in the range of 5 to 6 % W/V basis is 35 ltr HPPE dry container temper proof sealed free from grease dirt (or) other foreign material with plastic cover exclusively meant for drinking water chlorination all as per IS 11673 and complete all as specified and as directed.Note:- 35 ltrs HPPE dry container deemed to be included in quoted rate |
| 199 | POOL STANDARD – B23 Pool algaecide specifically effective against green, black spot & mustard algae.Packing: 5 Kg. sealed plastic containerMake:- Declibac or equivalent |
| 200 | POOL STANDARD – A94Fast acting pool clarifier to clear dull, hazy or cloudy water which can occur in newly filled pools, during warm weather, with pool start up or with algae growth. Packing: 25 Kg. sealed plastic containerMake:- Declibac or equivalent |
| 201 | POOL STANDARD – G24Pool balance module to increase Chlorine (sanitiser) level in pool water.Target limits for Free Available Chlorine: 2 ppm – 4 ppmPacking: 25 pieces in plastic containerMake:- Declibac or equivalent |
| 202 | Supply of Stequa Pack Pro V2 of Declibac model No P25V2.Make:- Declibac or equivalent |
| 203 | Supply of Stequa 411AE Refil of Declibac model No P25V2.Make:- Declibac or equivalent |
| 204 | S & F in repair fibre resin polymer gas chlorination system in water supply/ swimming pool instalations, capacity 200 Kg/hr, FRP cabinet, Rotameter, Flow control valve, vacuum regulator, differential pressure regulator, safety valves, gauges, pressure reducing valve, gas filter, chlorine injector and suitable pumps etc complete all as specified and as directed. |
| 205 | S & F in repair chlorine dosing system discharge flow 0-20 LPH, discharge pressure 4kg/ cm2, with suitable pump and 100 ltrs FRP tank complete all as specified and as directed |
| 206 | Removing/ Dismantling of unserviceable sodium Hypo chloride dosing equipment repairing the dosing equipment at site or taking to workshop repairing the dosing pump and return back to site and reinstalling the equipment, testing and commissioning the dosing pump with satisfactory functioning complete all as specified and as directed. |
| 207 | General Note:-Rate quoted is inclusive of all insurance and losses arising during manning of chlorine connected item contractor is 100% responsible for safety of all men, materials and life of the labour engaged/ user. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail