| 1 | M&L for excavation in trenches not exc 1.5m in wide and not exc 1.5 m in depth and getting out in hard/dense soil for laying of cables complete all as specified and directed. |
| 2 | M&L for returning, filling in, including spreading , levelling, watering and well ramming in layers not exc 25cm in soft / disintegrated rock complete all as specified and directed. |
| 3 | M&L for removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed. |
| 4 | Material and Labour Cutting /boring of existing road / path , hardstanding etc for taking out cable and water pipe to protection with iron cover plate for passing cable,water pipe and making good the disturbed road top surfaces withcement concrete of suitable depth and finished withspeed breaker complete all as specified and as directed. |
| 5 | M&L for PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of pole etc including form work complete all as specified and directed. |
| 6 | M&L for PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for pole and stay complete all as specified and directed. |
| 7 | Taking out unserviceable Steel tubular swaged Poles of any type and any sizes etc and removing from the site of work complete all as specified and directed. |
| 8 | S&F Steel tubular swaged Poles complete with cast iron base plate, finial taper plug,bolts,nuts & screws as specified type SP-31 (9.0 Mtrs long)as per relevant IS specifiecation including two coats of aluminimum paint over a coat of red oxide primer with pole numbering complete all as specified and directed. Note : Earth work andPCC shalll be measured and paid under relevant of this sch seprately |
| 9 | Supply and fix Warm white LED 45 W street light made up of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP 66 protection complete all as specified and as directed. |
| 10 | Supply and fix Warm white LED 70 W street light made up of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP 66 protection complete all as specified and as directed. |
| 11 | S & F of water proof LED strip 12 watt 24volt Tri colourlength in 19 mtr for decorative illumination, with power adopter. The cost is inclusive of adhesive required for fixing compelte all as specified and as directed. |
| 12 | Taking out unserviceable UG cables of any type and any sizes from trenches etc and removing from the site of work complete all as specified and directed.Note:- (i) Serviceable bricks obtained shall be stacked properly for re-use. (ii) Excavation and earth work shall be measured and paid separately under relevant item of these schedule. |
| 13 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 16 Sqmm 4 core in duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and as directed. |
| 14 | Supply & laying DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polethylene including couplers, bends, cap etc.,with smooth internal and profiled external surface for non pressure under ground cable complete all as secified and directed. |
| 15 | Supply and Fixing automatic operation Astronomical street light timer panel,switch having lighting control (ON-OFF) through sun rise/sun set by setting date,time and degree of longitude and latitude without separate light sensors and pre-wired with suitable size copper conductor single core PVC sheathed cable cubical outdoor type enclosure (Box type) made out of CRCA sheetthick totally enclosed withfrontopening,and vermin proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, and the nuts/ bolts etc used are to be made of rust proof materialwith necessary arrangement fincluding under and over voltage protection relay,contractor MCB 65A TPN, 230 volts,complete all as specified and directed. |
| 16 | Supply and FixingACP (Aluminium composite panel) LEDdisplay board with Acrylic projected letters, thickness 2mm LED lights inside mounted on ACP box,Size 4.5 x 2.5 fthigh quality weather protected transparent sheet. Fixingin wall/floor/gate withsuitable tools and plants, painting complete, along with pipe bracket with accessories includinglight grade GI pipeduly grouted/frame work for main gateincludingPCC type B2 (1:2:4, using 40mm graded crushed stone aggregates) including all necessary fixing arrangement as per site, including taking down old unserviceable board complete. Note: details specifications for ACPboards is submit withcomputer design sample for approval by Garrison Engineer |
| 17 | S & F Junction box ISI marked, with suitable hosing for MCB SP 6A including nut bolts washer clamps etc complete to be fixed on the steel tubular complete all as specifed and as directed at site. |
| 18 | S&FBracket assembly of various sizes as required for hanging ceiling fan with rubber shackle nuts, bolts and split pin complete all as specified and directed. |
| 19 | M&L for painting 9 Mtr steel tubular poles of any synthetic enamel paint over a coat of red oxide, Zinc chrome primer on steel surfaces of any descrption including cross arms, bracket etc, and writing pole number on the pole complete all as specified and directed. |
| 20 | M & L for painting RCC poles 9/11 Mtr long including cross arms etc. with one coat of white paint including preparation of surfaces and writing pole number on the pole complete all as specified and directed. |
| 21 | M&L for fixingsubmain wiring fortwo single core PVC insulated unsheathed , 1100 Volts grade, copper cable 1.5 Sqmm multistranded conductor and drawing through and including rigid PVCconduit of suitable sizebut not less than 20mm dia with conduit accessories etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade,cable 1.5 Sqmm copperconductor fixed to poles with saddles and screws and complete all as specified and as directed Note :- One run of PVC conduit, two runs of cable1.5 Sqmm and one run of earth wire 1.5 Sqmm shall be measured and paid as one unit. |
| 22 | Supply and laying of alluminium sevice wire 6 sqmm 2 core 1100 volts grade fixed on wall/roof etc all as specified and directed. |
| 23 | Material and labour for earthing complete with Glavnised iron plate 60x60 cm x 6 mm thick electrode buried directly in ground (earth pit no less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.5 Mtrs below normal ground level connected to glavnasied earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers all as shown in electrical plate no. 5 connected to earth test point and provn of GI pipe 20 mm dia medium grade for watering, GI pipe 40 mm dia light grade for earth strip protectionall as specified and including excavation, earth workprovn ofearth pit, pit cover, CI funnel, wire mesh etccomplete all as specified and directed. |
| 24 | Supply, Installation, Testing and Commissioning of White LED strip light IP68,CB and CE certified sealed with anti-UV polyurethanealong with accessories such as driver, mounting clips, connectors, etc. as required forstraight or curved coves and recessed applications with housing of Extruded silicone, wattage not exceeding 65W/ 5 Mwith lumen output of not less than 5000/ 5 M . Luminaire has a choice of beam angles of 120° degree. Fixture should run on input voltage of 24VDC. Lifetime should be at least 30000 burning hours at L50 at 25 degree centigrade with total IP66 protection should be provided. Controlled through DMX/Ethernet protocol. Luminaire uminaire should be BIS certified and CRS no for both luminaire and driver along with LM79report from NABL accrediated LAB should be should be submitted along with BID. Similar to Philips BGC201 RGBWith Accesories Cable Driver And Decoder And U Clamp etc complete all as specified and directed by Engr-in-Charge Make- Philips/Havells orEquivalant. NOTE : details of specifications FACADE lighting design for main entry gate NAVAL TRANSMITTING STN (SVP) ,MARCOSand TECHNICAL COMPLEX is submit withcomputer design sample for Recommendation by Engr in Charge and approval byGarrison Engineer Minniebay. |
| 25 | Supply, Installation, Testing and Commissioningof exterior-rated architectural floor/wall/Pole mounted, IP66, round flood light complete with antiglare snoot. The power consumption should be not more than 24 watts, minimum system lumen delivered shall be 1140 lumens ±10%,10 deg /15° beam angle ±10%, CCT-RGBNW. LED from CREE/NICHIA/LUMILED/OSRAM. The housing material should be die-cast aluminum with Electrostatically applied polyester powder coating, The luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Bracket shall have a locking mechanism to fix and secure the required tilting angle, ±90°. It should haveCRI>80, and SDCM≤4. The driver should be integrated AC with PF>0.9 & and THD<20%. Leader cables, jumper cables, and IP68 connectors are included, minimum IK06. The operating temperature should be of -40°C to 50°C range and the storage temperature shall be -40°C to 70°C. the weight of luminaire shall be min 1.8kg. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test.Photometric data shall be passed on test results from an independent testing lab. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. The luminaire should be BIS-certified. The luminaire manufacturer shall provide optical performance, polar diagram and photometric data in various formats including IES files in accordance with IES 79-08. This includes all the required hardware for the successful operation of the luminaire. All the technical parameters of the luminaire need approval from the lighting consultant Similar to BVP371 12LED RGBNW 220V 15 DMX 24W HE etc complete all as specified and directed by Engr-in-Charge Make- Philips/Havells orEquivalant. |
| 26 | Supply, Installation, testing and commissioning of exterior architectural RGBNW (4000K) LED linear luminaire with integrated driver of 1000mm length haveing maximum wattage of 50w rated input supply voltage 220-240 vac luminaire should controlled through DMX/Ethernet high optical efficiency PC opal covers optics fordirect viewarchitectural lighting application . Beam angles option of A2: 16x35° Beam AngleBeam Angle . Wattage of 24W 24V DC poweredand should be able to produce light by LED Channels of RGBNW( 4000K )and DMX 512 based controller. The luminaire should have Anodic oxidation finish with extruded al housing and Anti-aging and anti-UV high optical efficiency PCopal covers. The system lumen should be more than 1020 lm full light output.The luminaire should be IP 66 and IK 06 type luminaire.luminaire controls via DMX512 with Auto addressing for easy configuration. The connectivity should be of a daisy chain topology, allowing easy installation to form long run lengths. The same shall include Installation clamps, 5core/cat-6 or suitable control cables UV and weatherproof, other required accessories & hardware. The luminaire shall be extruded Aluminium with Electrostatically applied polyester powder coating, silicon gasket and clear tempered glass, minimum dimension of Dimention of 1000 mm x 38 mm x 47 mm (without bracket)The Luminaire shall have tilting adjustability +15° to - 90°. The LED luminaire shall have SDCM<4 for white Life Will beWhite: 50,000 hrs L70 at 35°C | RGB: 50,000 hrs L50 @ 35°C Operating temperature from 0 to 50 deg Centigrade, Class III2 pole flat cable, 5 pole flat cable, 2x1.0mm2 + 3x0.3mm2 with connectors IP67 male/female connectors for through power+signal connection SDCM<4with CRI>=80. Lumen maintenance of at least L70 @ 50000 hours at 35 degree. Maximum weight of the luminaire should be 1kgs.The product shall comply to and shall have test repots for IEC 60598-2-5:2015, IEC 60598-1:2014 + A1, IEC TR 62778:2014 (for LED chips), EN IEC 55015:2019+A11, EN 61547:2009, EN 61000-3-2:2019, EN 61000-3-3:2013, IS 10322 (Part 5/Sec5):2013, LM80 etc complete all as specified and directed by Engr-in-Charge Make- Philips/Havells orEquivalant. |
| 27 | M&L for fixing 200 W 24V IP67DC Power Supply etc complete all as specified and directed. Make- Philips/Havells orEquivalent. |
| 28 | M&L for fixing Controller to First Luminaire 4PAC/ DMX cable 2m (10 pcs set) Similar to Signify ZXP399 Lead 4P DC/DMX cable 2m (10 pcs) or Equivalent complete all as specified and directed. |
| 29 | Supply, Laying, Connecting, Testing & Commissioning addressing Kit shall automatically write address to a whole group of interconnecting luminaires within minutes. It shall be Miniature industrial design, compact size and touch screen. It can be powered by a power bank with a Micro-B type USB port for on-site programming and testing after installation. The housing shall be extruded Aluminum with black finish weighing approx. 0.2Kg with temperature range-10°C to 40°C, input voltage of 6-24V DC and humidity range of 10 to 90% (no condensation). The product shall be compact in size, compatible with multiple types DMX512 chips, with Built-in test animation effects, SD card slot to store animation and scenes. The addressing kit shall support standard RDM protocol, searching for RDM luminaires and static detection, Color-pick functions, and can be powered by Micro-B type USB power supply.etc complete all as specified and directed. Make- Philips/Havells orEquivalant. |
| 30 | Supply & Fixing of DMX controller for upto 30 Luminaire Uni Player MiniPort with IP BOX. etc complete all as specified and directed. Make- Philips/Havells orEquivalant. |
| 31 | M&L for fixing 2 Core 1.5 sqmm copper conductor armored sheathed cablecomplete all as specified and directed. |
| 32 | M&L for fixing Cat -6 high performance Ethernet cable with four twisted copper wire pairs supporting speeds upto 10 GBPS over short distances and 1 GBPS reliably operating upto 250 MHZ Make:- D-link, Belden and Scheneider or equivalent complete all as specified and directed. |
| 33 | M&L for fixing IP-68 Junction Box - 150mm x 150mm with gell with suitable required connector complete all as specified and directed. |
| 34 | M&L for fixing Hensel box For Driver ( 3 Nos Driver) complete all as specified and directed. |
| 35 | M&L Painting of existing old surfaces to aluminum and Iron Main Gate size 7.5mtr x 4.5 mtrs,Preparation of allaluminum and iron surfaces mechanical or manually to ensure the complete removal of all loose, flaking old paint, rust, scale, and surface contaminants. Iron/Steel by Useing wire brushes and sanding down to bare metal where necessary.The surface must be thoroughly cleaned of dust and degreased with mineral spirits or approved solvent before priming. Application of one coat of heavy-duty,including high-build primerRed Oxide Epoxy Primer to the prepared metal surface complete coverage of all welds, edges, and corners finish, and final touch-ups complete all as specified and directed. |