| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep and getting out in hard/dense soil for laying of UG cables completeall as specified and as directed. |
| 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thickness with hard/dense soil completeall as specified and as directed. |
| 3 | Removing excavated materials (soils) to a distance not exceeding 50m and depositing where directed at a levelnot exceeding 1.5 m above the starting point completeall as specified and as directed. |
| 4 | Earth cushioning to UG cables using excavated soil riddled by using large sieve to separate the composite particles/roots etc and refilling in trenches completeall as specified and as directed.Note :-For measurment andpayment purpose onlyPunned thickness will be considered. |
| 5 | Material and labour for making good the disturbed surface of road/path/hard standing by using Plain Cement Concrete (1:2:4) type B-2 (using 40 mm graded crushed stone aggregate) 0.45 mtr wide and 0.15 mtr thickincluding demolition of old Plain Cement Concrete and removing the debris from site completeall as specified and as directed. |
| 6 | Supply and laying galvanised tubes light grade with fittings laid in floor, wall,celings, etc 80 mm dia completeall as specified and as directed. |
| 7 | Supplying and laying un-reinforced precast concrete cable cover class HV type 1, flatof size 300x180x40mm for cable protection completeall as specified and as directed. |
| 8 | Relaying of un-reinforced precast concrete cable cover class HV, type 1, flat size 300x180x40mm for cable protection obtained from excavation completeall as specified and as directed. |
| 9 | Taking down HT under ground cable of size 120 sq mm from trenches andremove from sitetostore yard or considering under Sch of Credit completeall as specified and as directed.Note :-(Excavation / earth work measured and paid separately) |
| 10 | Relaying of HT cable obtained from excavation for reroutingand connecting, up with existing HT cable testing and commissioning of 120 Sqmm 3 Core completeall as specified and as directed.Note :- (Excavation/ earth work and Joints measured and paid separately) |
| 11 | Supply and laying XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable heavey duty with aluminium conductor 11000 volts (earthed) grade gross sectional area 120 sqmm 3 core inciding conecting up with existing cable testing and commissioning completeall as specified and as directed. Note :- (Excavation & Joints paid and measured separately) |
| 12 | Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 120 to 185 sq mm completeall as specified and as directed. |
| 13 | Supply and fix cable jointing kit for 11 KV grade cable for straight through heat shrinkblejoint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 120 to 185 sq mm completeall as specified and as directed. |
| 14 | Excavation by trenchless technology by boring of holes under road, pavement, ham trenchless technology using ultra sounding technique and necessary machine including 150 mm dia suitable for 0.4 MPA working pressure completeall as specified and as directed. |
| 15 | M&L for dismantling/cutting of existing road/path/hard standing cement concrete (unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) suitable for laying earth lead any type any dia under the road/path/hard standing completeall as specified and as directed. |