| 1 | Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, etc. and getting out complete, all as specified. |
| 2 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete, all as specified. |
| 3 | Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified. |
| 4 | Supply and Fixingin repairPP-R (Polypropylene random coplymer) concealed pipes 25 mm boreSDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete, all as specified. |
| 5 | Supply and Fixing in repair PP-R (Polypropylene random coplymer) concealed pipes 40 mm boreSDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete, all as specified. |
| 6 | Supply and Fixing in repair PP-R (Polypropylene random coplymer) concealed pipes 50 mm boreSDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete, all as specified. |
| 7 | Supply and Fixing in repair PP-R (Polypropylene random coplymer) concealed pipes 90 mm boreSDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete all as specified. |
| 8 | Supply and Fixing in repair PP-R (Polypropylene random coplymer) concealed pipes 100 mm boreSDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete, all as specified. |
| 9 | M&L for using a chisel and remove the loose pieces of matter surrounding the crack protion on OHT and applying one coate of concrete binding agent and brush it along the crack, and allow the surface to dry until it appears to have a tacky consistency. Over dry surfaces 10mm thick plaster work in CM 1:3with WPC ( using Dr fixit chemical ) finished even and smooth with using extra cement complete all as specified and as directed by Engr-in-Charge .After completing the above all process applying two coats of corrosive resistance paint complete all as specified . Note: cost of scaffolding using in entire work included in quoted rate . |
| 10 | Disconnection & taking out to submersible pump with motorof capacity 25 to 52 HPalong with column pipe of any size alongwithlowering the same after repaired motor / pump along with existing / replaced column pipe, and re-connection for three phase AC Supply and tested at site to the satisfaction of Engineer-in Charge. Note:- (i) Repair / replacement of pump /motor / column pipe / rubber gasket / Nut bolt and washers/Cable shall be measured and paid supply only in respective items of Schedule ‘A’. (ii) Transportation to defective motor / pump from well to work shop and vice-versa shall be deemed to be included in the unit rate of this item.Nothing extra shall be admissible on this account. (iii) The cost of T&P required for taking-out, loweringtosubmersible motor / pump / column pipe de-water the UG sump shall be deemed to be included in the unit rate of this item. Nothing extra shall be admissible on this account. |
| 11 | Dismantlingto existing unserviceable submersible pump motor of 52 HP, 3 phase, 440 volts, 50 Hz, 2900 RPM and rewinding to stator with PVCinsulated copper winding wire including sleeves, thimbles & minor spare parts like as bronze bushes, gland packing, water seal & adopter, stainless steel shaft,Neck ring,Bowl casing, Shaft sleeve ,impeller of gun metal etc and re-assembling to the same motor after repair work . complete all as specified and as directed by Engineer-in-Charge. |
| 12 | All as per item No 11 here in before butrewinding of submersible motor of cap41 HP |
| 13 | All as per item No 11 here in before butrewinding of submersible motor of cap25HP |
| 14 | Disconnecting of centrifugal pump setelectrically and from suction and delivery line. Transportingpump set to workshop for repair. Strip opening of induction motor 40 HP and taking out burnt out motorwindingwire from stator and rotorcarefully, cleaning the stator slots carefully, rewinding to statorand rotor with copper winding wire as perexiting size of wire including providing mica paper in stator slots thimbles, vanishing to winding wire anddrying up of the insulation in heating chamber , assembling to motor after repair workand meggertesting for insulation .Transporting of the motor to site , refixng /reinstallation , reconnecting and testing for smoth and trouble free running/functioningcomplete to the satisfaction of Engineer-in-Charge.Note : Defective spare parts excepts winding wire & bronze bushes etc shall be measured & paid separately under respective itemof this Sch ‘A’ as “Supply only” . But fixing charges shall be deemed to be included in the unit rate of this item. Nothing extra shall be entertained on this account. |
| 15 | Supply only ball bearing as per existing size complete all as specified. |
| 16 | Supply onlygun metal impeller as per existing size complete all as specified. |
| 17 | Machining workfor turning ofsteel shaft & made as per required size complete all as specified. |
| 18 | S&F MS coupling suitable for 40 HP centrifugal electric driven pump set with rubber pads as per existing make and model complete all as specified and as direted |
| 19 | Suppy only rubber gasket for column pipe (80/100/125 bore)complete all as specified and as directed by Engineer-in-Charge. |
| 20 | Supply only Nuts , bolts and washer for column pipe all as required at site or as per sample complete all as specified. |
| 21 | Supply only Rubber gasket for column pipe (65/80/100 bore) in lieu of provided with new Rubber gasket for column pipe (65/80/100bore) complete all as specified and as directed by Engineer-in-Charge. |
| 22 | S&F for Nut, Bolt & Washers machine made suitable for jointing of column pipe fixed as in repaircomplete all as specified and as directed by Engineer-in-Charge |
| 23 | Supply only 65 mm bore mild steelwater pipeheavy duty both endflanged as column pipe (each length of pipe 3 metre long) as in repair complete all as specified and as directed by Engineer-in-Charge. |
| 24 | All as per item No 23 here-in-above but of 80 mm dia. |
| 25 | All as per item No 23 here-in-above but of 100 mm dia. |
| 26 | Supply only PVC insulated multi-stranded copper conductor 16 Sq mm (nominal area) 3 core submersible cable (copper) and connected to submersible pump setincluding submersible cable joints & LT panel board complete all as specified and directed. |
| 27 | All as per above item No 26 here-in-before but for 25 Sqmm |
| 28 | All as per above item No 26 here-in-before but for 35 Sqmm |
| 29 | S&F FASDS suitable for 52 HP Submersible electric driven pump set ,3 Phase , AC 415 volt ,50 HZ( for min current carrying cap 90 Amps) withMS enclosurewith Std protection ie single phase, over volt /under volt etc complete all as specified. |
| 30 | All as per above item No 29 here-in-before but for 41 HP. |
| 31 | All as per above item No 29 here-in-before but for 25 HP. |
| 32 | Disconnection and removing the U/S MCCB, 4 pole, 160 Amps and S&F MCCB, 4 pole, 160 Amps, 50 Hz, 415 volts, Range : 125 - 160A, rupturing capacity 25 KA including connecting the cables complete all as specified and as directed. |
| 33 | All as per item No. 32 above but Capacity 200Amp. |
| 34 | All as per item No. 32 above but Capacity 125Amp. |
| 35 | All as per item No. 32 above but Capacity 100Amp. |
| 36 | All as per item No. 32 above but Capacity 63 Amp. |
| 37 | S&F in repair/replecement ofAutomatic star/delta starter in SS enclosure with relay max range 28 to 45 Amps, 415V/440V and 3 Nos of Power Contactors of capacity 42 Amps, Prewired with ON/OFF Buttons complete including connecting the cable all as specified and as directed. |
| 38 | Cleaning of overhead water storage tank of capacity 1,00,000 gallon by scraping internal and external surface of tank with brush and removing all scale / dirt / deposited silt including washed to internal surface of tank with solution of bleaching powder and applying two coat of anti fungal paint to internal and two coated cement base paintto internal and externalsurfaces of wall, top and bottom of tank, pillars / beams/ pipesetc after preperation ofsurface of OHT and providingone coat of synthetic enamelled paintwith colour code on inlet / outlet/ washout/over flow pipes surfaces as per existingwithwritting the cleaning date with white colour on black base all as specified and as directed Note : - Removing/Cleaning of Honey Bee hives shall be the responsibility of the contractor.No delay, No additional charges shall be considered on this account rates quoted against the item shall include the said element.b) Contractor is responsible for making all safety arrangments, scaffolding/jhullafor carrying out the above job with due care at a height of approx 22 Mtrc) Contractor may visit the site before quoting the tender.(d) Insurance of labour for cleaning of over head tank shall be submitted to the dept before commencement of work and the cost of insurance shall be born by the contractor.Nothing extra shall be admissible on this account. |
| 39 | All as per above item No 38 here-in-before but over head water storage tank of 50,000 gallons capacity. |
| 40 | All as per above item No 38 here-in-before but cleaning of semi under ground water storage tank of 75,000 gallons.Note for item No 38 to 40 - (i) The cost of required T&P, machine, motor, scaffolding shuttering shall be arranged by the contractor at own cost. |
| 41 | Supply and filling ofcalcium basedgranular (Calcium hypochlorit granular) disinfectantwith characteristics 65%by mass minimum avaiable chlorine,stability 1/15 (loss of cloride on basis of available chloride max), Water insoluble matter(max 6%), calcium hychoxide(max 4%),sodium chloride(max 15%) particle size(passing through 1.70mm TS sieve),min 99.5% by mass for Chlorination of water having more stable than chlorine gas, supported with test certificate, all as specified and including daily testing of water from different -different locations in presence of MES / Medical authorityfrom SHO/MI Room and maintaining record of test resultin a register and otaining signature ofMedical Authority for all as specified. Note: sample will be approved by GE. |
| 42 | Supply & Fixas in repair incl testing and Commissioning of chemical dozing pump high pressure single head, adjustable dozing pump and high pressure range 0 to 100 PSI , Power 230 volts, 50 Hz, 40 Gallons per day self priming with vertical or Horizontal mounting type complete all as specified. Note: sample will be approved by GE. |
| 43 | Supply & Fixas in repair chemical dozing system consisting oftwo Nos FRP Tanks i e 1x170 Litre capacity and 1x 100 Ltr capacity with FRP lid and level gauge alongwith water inlet /outlet line with Y strainer, drain plug, over flow pipe, having conical bottom for sludge deposition, port hole with coverPlastic - mounted on tank. Lid will have port hole for pouring Granular chemical and water and shall have provn of mountingdozing pump complete all as specified. Note: sample will be approved by GE. |
| 44 | Supply & Fixas in repair agitator motor 120 Watt,copper wound, 900 RPM, Single phase 230 Volt with Shaft and impeller and all accessories suitable for mounting on FRP Tank lid or wall all as directed by Engr incharge. |
| 45 | Supply & replacement ofpump tube for chemical dozing systemas per existing make and dimension and as directed complete all as specified and as directed |
| 46 | All as per item No. 45 above but injection check valve 3/8\" . |
| 47 | All as per item No 45 abovebut discharge tubing 3/8\" . |
| 48 | All as per item No. 45 abovebut Rotar Assy with bearings brackets and tolerances ring . |
| 49 | All as per item No.45 above but suction line strainer 3/8\" . |
| 50 | All as per item No.45 above Roller Assy . |
| 51 | All as per item No. 45 above but Gear motor complete 230 volt, 50 Hz . |
| 52 | All as per item No. 45 above but Coil 250 volt 50 Hz . |
| 53 | M&L DI pipe 200 mm (certifugally cast) class \"K-7\" (ISI Mark) in anylength with spigot and socketendscomplete including rubber ring joint (Tyton joint)as per IS- 1536-2001 jointedand laid in trenches or in any position, complete including taking down any type and size of pipe all as specified . Note :- Cost of rubber ring (tyton)joint is deemed to be included in the quoted rates |
| 54 | All as per item No. 53 above but 150 mm. |
| 55 | All as per item No. 53 above but 100 mm. |
| 56 | All as per item No. 53 above but 80 mm. |
| 57 | Supply and fixing of CI/DI fittingsof size up 200 mm bends ( any radius and angle )Tapers any type,( straight, bend , increasing,decreasing or double socketetc)Tee pieces single branch. `Y` junction , double branch cross ( all socket or socket and spigot/ flanged as required at site) collars, caps and plugs etc.,complete all as specified. |
| 58 | Supply and fixing Rubber gasket joint for 100 mm dia pipe complete all as specified |
| 59 | All as per item No. 58 above but 150 mm dia pipe complete all as specified |
| 60 | All as per item No. 58 above but200 mm dia pipe complete all as specified |
| 61 | Disconnection and removing the U/S Sluice Valve and S&F Sluice valve PN-1.6 (ISI marked) confirming to IS-14846-2000 with brass spindle and fly net flanged both ends and drilled for jointing, wheel head type including nuts, bolts, washes & 02 Nos rubber insertion packingetc for 200 mm bore pipe and fixed, in epairs, complete all as specified. |
| 62 | All as per item No. 61 above but 150 mm bore. |
| 63 | All as per item No. 61 above but 100 mm bore. |
| 64 | All as per item No. 61 above but 80 mm bore. |
| 65 | S&F Gun-metal, globe or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 50mm dia, in repairs , complete all as specified. |
| 66 | All as per item No. 65 above but 40mm dia. |
| 67 | All as per item No. 65 above but 25mm dia. |
| 68 | All as per item No. 65 above but20mm dia. |
| 69 | S&F Cast iron Non return valve of 150 mm dia withprovn of two end spoigot and socket suitable for rubber tyton joint and one end flangedfixed with removable MS plateincl ,rubber gas kit,nut,bolt ,washers,andmaking suitable fixing arrangement to spoigot and sockete DI 200 MM dia pipe etc complete all as specified .Note : Fitting will be measured and paid separetly, if any, required. |
| 70 | S&F 100 mm bore cast iron Air release valve with two air outlets complete with fixing arrangement, as in repair complete all as specified and as directed by Engineer-in-Charge. |
| 71 | Arresting of water leakage from existing pipe line in position from DI/CI/GI pipe of size 150 mm to 300 bore ,including excavation through Men/Mechanical power ,cutting,welding as per site requirement,jointing material such as lead joint/gaskit joint/CI fitting, nut and bolts,washers and refilling etc complete all as specified .Note:-(i) Excavation up to 1x1x6 Mtr will be deemed to be includedin quoted rate.(ii), DI / CIfitting and pipe length) will be measured and paid saperately under appropriate item of sch \"A\" herein.(iii) Cost of new pig lead/lead wool required for repair of leakages is deemed to be included in the quoted rates. |
| 72 | All as per item No. 71 above but 80 mm to 100mmbore |
| 73 | All as per item No. 71 above but 40 mm to 50 bore. |
| 74 | All as per item No. 71 above but 20 mm to 25 mm bore. |
| 75 | All as per item No. 71 above but 15mmbore. |
| 76 | Locating blockage in existing distribution pipeline 80mm dia any type in position by excavation work manualy in any type of soil upto 750x500mm upto max 2Mtr length at various location( Maximum up to 3 location ) incuding necessary cutting/threading/welding work & provision of required size offittings such as union/socket 1no ,replacement of damaged pipeline,returning filling and removal of surplus soil complete all as specified .Note :-(i) Pipe length will be measured and paid saperately under approriate item of sch \"A\"(ii) Contractor shall restore supply system within in 8Hrs. |
| 77 | All as per item No. 76 above but 40/50mm dia. |
| 78 | S&F Run lead joint for 150 mm pipe |
| 79 | All as per item No. 78 above but200 mm pipe |
| 80 | All as per item No. 78 above but 100 mm pipe |
| 81 | All as per item No. 78 above but 80 mm pipe |
| 82 | Supply and fixing Motor protection unit(MPU)three phae415 volt , 50 HZ having following protectiion (a)Automatic phase sequence corrector (b)Automatically correct inut reverse phase, (c) single phase protection (d) , LV, HV, LIV, Auto on off, timer,(e)Dry running (f)under & over current, unbalancing ,float switch with built in CTs (Automatic-RTM ) complete all as specified. & direcected ModelMiCOM P22x of Schneideror equivalent in Seimens/L&T |
| 83 | Construction of valve pit chamber of size 120 x120 x120 cm with brick masonary in cement mortar 1:4, all internal surface to be plastered in cement mortar 1:4 and floor 100mm thick in cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate, including 6.00 mm thick MS sheet cover fixed with angle iron frame 40x40x6mm thickwith locking arrangement and lifting handle including two coat of anti- corrosive synthetic enamelblack paint over a coat of red oxide primer to steel surfaces including necessary earth work and PCC copping in cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate complete all as specified |
| 84 | Construction of valve pit chamber of size 90 x90 x90 cm with brick masonary in cement mortar 1:4, all internal surface to be plastered in cement mortar 1:4 and floor 100mm thick in cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate, including 6.00 mm thick MS sheet cover fixed with angle iron frame 40x40x6mm thickwith locking arrangement and lifting handle including two coat of anti- corrosive synthetic enamelblack paint over a coat of red oxide primer to steel surfacesincluding necessary earth work and PCC copping in cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate complete all as specified |
| 85 | Supply and fixed only Pig lead complete all as specified. |
| 86 | Supply and fixed only lead wool complete all as specified. |
| 87 | S&F in repair Tubes 20 mm bore, ‘medium grade’, ISI MARKED, galvanized with all fittings and fixed completelaid in trnches or walls and ceilings or laid in floors, complete all as specified. |
| 88 | All as per item No. 87 above but 25 mm bore. |
| 89 | All as per item No. 87 above but 40 mm bore. |
| 90 | All as per item No. 87 above but 50 mm bore. |
| 91 | Cutting and threading existing 15 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) .complete all as directed by the Engineer- in-Charge. |
| 92 | All as per item No. 91 above but 20 mm bore. |
| 93 | All as per item No. 91 above but 25 mm bore. |
| 94 | All as per item No. 91 above but 40mm to 50 mm bore. |
| 95 | M & L for Cutting CI/DI pipes and reducing to required length before laying (pipes supplied by M.D. for laying only) of the following sizes.Note :- Each cut will be measured and paid separately under respective item |
| 96 | S&F in repir power contractor 3 pole ML-4 conforimg to cat part No SS-90910of L&T with DC coil of AC3 rating 70 to 110 Amps suitable for motor including connection with new copper cable of sitable size and connection with new copper lugsand testing for smoth and trouble free running of starter on load. |
| 97 | S&F in repir power contractor 3 pole Type MNX95 (2NO+2NC) 3 pole of L&T cat part No CS 94136 with DC coil of rating AC-3 160 Ampssuitable for motor including connection with new copper cable of sitable size and connection with new copper lugsand testing for smoth and trouble free running of starter on load. |
| 98 | S&F in repair Thermal over load relayfor motor staterML-3 with start and off reset ofrange 28 to 42 Amps conforming |
| 99 | All as per item No. 98 above butML-5 with start and off reset ofrange 45 to 75 Amps conforming |
| 100 | Chemical analysis test of clear water collectedfrom N area OHT and Hallomajra UG Sump the chemical parameter can include pH, acidity, alkalinity, chlorine, hardness , dissolved oxygen, and biological oxygen and the complete report sall be sumited by contactoras per direction of Engr in charge |
| 101 | Note: For the purpose of arriving at lumpsum amount, the amount of credit schedule i.e Sch \"A\" section II (i.e Rs 1,26,274.00 shall be deducted from the total amount arrived. |
| 102 | Total of Schedule \"A\" Rs. |