| 1 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth & getting out in soft soil complete all as specified and directed |
| 2 | M&L for PCC 1:4:8, type D-2, using 40mm graded stone aggregate as in foundations, fillings and Mass concrete complete all as specified and directed. |
| 3 | M&L for RCC(Design mix) M-25 (20mm graded aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 4 | M&L for RCC(Design mix) M-25 (20mm graded aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like. |
| 5 | M&L for RCC(Design mix) M-25 (20mm graded aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 6 | M&L for RCC(Design mix) M-25 (20mm graded aggregate) as in roof beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed |
| 7 | M&L for Hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed |
| 8 | M&L for 100mm thick, PCC 1:3:6 type C-2(using 40 mm graded crushed stone aggregate) as in sub base of floorscomplete all as specified and directed. |
| 9 | Formwork for rough finished surfaces to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beam and similar work; vertical or to batter complete all as specified and directed |
| 10 | Formwork for rough finished surfaces to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed |
| 11 | Formwork for rough finished surfaces to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc also splays between floors and beams, etc complete all as specified and directed |
| 12 | S&F Formwork for rough finished surfaces to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work complete all as specified and directed |
| 13 | S&F Reinforcement TMT Steel bars of grade Fe-500/Fe-500 D of 10mm dia and over, cut to length, bent to shape required, incl cranking,bending , spirally for hooping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and directed |
| 14 | S&F Reinforcement TMT Steel bars of grade Fe-500/Fe-500 D of 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, incl cranking,bending , spirally for hooping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and directed |
| 15 | M&L for Brickwork with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 16 | M&L for Rendering 15mm thick in CM 1:4 on brick / concrete surfacesfinished even and smooth without using extra cement complete all as specified. |
| 17 | M&L for rendering 15 mm thick on brick or concrete other than fare surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed |
| 18 | M&L for rendering 5mm thick on ceiling in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and directed. |
| 19 | M&L for preparation of newly plastered surfaces and applying two coat of distemper oil emulsion white tinted over a coat of alkali resistant primer over a coat of wall care putty interior grade complete all as specified and directed. |
| 20 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over a coat of exterior grade wall care putty complete all as specified and directed. |
| 21 | M&L for Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning the surfacescomplete all as specified and directed . |
| 22 | M&L for APP based polymeric membrane minimum weighing 3.50kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm)land on primed surface by forced application complete all as specified and directed |
| 23 | M&L for Applying two coat of bituminous aluminium paintcomplete all as specified and directed |
| 24 | S&F Non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm as in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the coloured tiles laid over and including 15mm thick screed bed or bedding layer CM 1:6 for laying floor finishes complete all as specified and directed. |
| 25 | S&F coloured Glazed ceramic tiles in vertical surfaces (450x300x7mm/600x300x7mm) set and jointed in neat cement slurry and pointed in white or coloured cement to match as in vertical surfaces laid over and including 10mm thick back coat in CM 1:4 complete all as specified and directed. |
| 26 | M&L for 75mm thick PCC in plinth protection and paving 1:3:6 type C-1,(20mm gradded aggregate) finishing cement concrete evenand smooth in slope without using extra cement complete all as specified and directed |
| 27 | M&L for Powder coated (minimum thickness 50 micron) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 28 | M&L for powder coated anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 No.) complete all as specified and directed. |
| 29 | S&F 4.8mm thick glass ordinary quality, ground or obscured or frosted, on one sidefixed in windows/ventilators in squares n. exc 0.50 Sqm in each pane complete all as specified and directed. |
| 30 | S&F Fe - 410-W (Gde E- 250) Quality-A for Framed work as in doors , chowkhats or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, support to velley gutters, winties for roof sheets, framing for monkey proofing, welded mesh, support to sign board & fencing post, etc as specified to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed |
| 31 | S&F in repairs rolled mild steel plate girder or single stanchions built of one beam or channel section with flange plate, caps, bases, spices, angle bracket, cleats and other connection Fe-290 (Gde 165) as specified to be prepared for hanging or sliding with and including either hooks or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and handing also fastening and fixing complete all as specified and directed. |
| 32 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and as directed. Note: stainless steel butt hinges and necessary S S crews shall be paid separately. |
| 33 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directedNote: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 34 | S&F butt hinges 100mm long stainless steel complete all as specified and directed. |
| 35 | S&F 100mm long SS dash fasteners complete all as specified and directed. |
| 36 | S&F 150mm long, aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed. |
| 37 | S&F 150mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 38 | S&F 15mm bore Pillar taps, fency type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-Nuts, screwed for iron pipe and fixed complete all as specified and directed |
| 39 | S&F stop valves 15mm bore cast copper alloy fency type, chromium plated with crutch butterfly handle, screwed down and screwed for iron pipe or for brass ferrule and fixed as specified and directed. |
| 40 | S&F CP bib tap 15mm bore cast fency type chromium plated copper alloy with crutch butterfly handle, screwed down and screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed |
| 41 | S&F brass chromium plated shower rose 150mm with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed. |
| 42 | S&F 15mm bore medium grade GI tubes with all fittings and fixed complete to walls or laid in floor complete all as specified and directed |
| 43 | S&F 20mm bore medium grade GI tubes with all fittings and fixed complete to walls or laid in floor complete all as specified and directed. |
| 44 | S&F Vitreous china wash hand basin pedestal pattern white including, waste coupling and waste pipe complete all as specified and directed. |
| 45 | S&F vitreous china wash down water closet pan (pedestal pattern), (excluding flushing cistern and flush pipe) including seat and cover and connection to drain or out going pipe and to flushing pipe, antisyphonage pipe etc complete all as specified and directed. |
| 46 | S&F in repairs vitrious china squatting pan Orissa pattern size 580x440mm white with integal foot rest, including concrete bedding, P or S trap lime concrete beddingand all internal fitting, inlet, outlet pipe connections etc & making good floor complete all as specified and directed. |
| 47 | S&F PVC valveless flushing cistern 10 Ltr capacity (white), syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flushing pipe complete all as specified and directed. |
| 48 | S&F in repairsPVC connection 15 mm size with PTMT nuts of length 600mmcomplete all as specified and directed. |
| 49 | S&F CP grating (with and without hole) of size 125mm complete all as specified and directed |
| 50 | S&F CP jet spray for EWC complete all as specified and directed. |
| 51 | S&F CP soap dish complete all as specified and directed. |
| 52 | S&F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 53 | S&F looking mirror of size 600 mm x 600 mm mirror of selected quality glass fixing in PVC frame fixed with rawl plugs & screws complete all as specified and directed. |
| 54 | S&F PVC (SWR) 110 mm bore pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed |
| 55 | S&F in repairs Rotational moulded polythene water storage tanks (Cylinderical vertical with closed top) hoisted and fixed in position 1000 ltrs, including 20 mm bore Ball PTMT valve, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed and dismantling of old water tank complete all as specified and directed. |
| 56 | S&F 15mm bore Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule complete all as specified and directed |
| 57 | S&F 20mm bore Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule complete all as specified and directed |
| 58 | S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal, complete all as specified and directed. |
| 59 | S&F 110mm bore pipe PVC (SWR) vent cowland fixed, complete all as specified and directed. |
| 60 | S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 61 | S&F PVC (SWR) Nahni trap 125/110mm setting and jointing with solvent cement complete all as specified and directed. |
| 62 | S&F 75mm bore PVC (SWR) pipes in any length with rubber ring joints fixed to walls including clamps complete all as specified and directed. |
| 63 | Returning, filling , including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified. [Note : A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming complete all as specified and directed |
| 64 | Removal of excavated material (soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed |
| 65 | M&L for PCC 1:3:6, Type C–1, using 20 mm graded stone aggregate as in coping including use and waste of form work and finishing the exposed faces of concrete even and smooth without using extra cement complete all as specified and as directed. |
| 66 | M&L for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed. |
| 67 | M&L for 200mm bore of reinforced concrete pipe class NP3 laid in trenches and jointed with collar complete all as specified and directed. |
| 68 | M&L for Concrete bed to drain pipes of size 200 mm bore packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete,Type C2, 1:3:6, using 40 mm graded stone aggregate complete all as specified and as directed. |
| 69 | M&L for Precast RCC 1:2:4, Type B–1 using 20mm graded stone aggregate as in landings, cover slabs [for manholes etc], chullah hoods, Chajjas, water troughs, mangers, Shelves and similar articles with plain faces including formwork, set in cement mortar 1:4 complete all as specified and as directed. |
| 70 | M&L for Rendering 15mm thick in CM 1:4 on brick / concrete other than fair surfacesfinished even and smooth without using extra cement including mixing water proofing compound as per Manufacturer\"s instructions complete all as specified. Note: Water proofing compound shall be measured and paid separately. |
| 71 | Supply only Liquid water proofing compound complete all as specified and directed |
| 72 | M&L for PCC 1:2:4, Type B–1, using 20mm graded stone aggregate as in Surface Channels and Drain etc.complete all as specified and as directed. |
| 73 | Extra for forming fair finishing drain or channel 90cm inner girth in cement concrete, using extra cement incl forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 74 | M&L for construction of septic tanks, foundation in PCC 1:2:4, brick work in cement mortar 1:4, RCCSlab covers includingRCC precastmanhole coverhaving 6mm plate embedded all around/fiber reinforced cover with angle iron frame Vent shaft and sludge chambers etc. for 25 users including necessary earth work in any type of soil (soft/loose/hard/dense) all as shown on drg No TD-217 sheet No 17/ to 7/7 complete all as specified and directed. |
| 75 | M&L for construction of Soakage wells of size 3.0m dia & 6.0m depth ( effective depth ) in ordinary Soil, Foundation in PCC 1:3:6, wells of Honey combed and solidin M-25 RCC including intercepting chamber, screen chamber Brick work in cement mortar 1:4, RCC cover slabinM-25/ RR masonry / Filling with brickbats,all as including necessary earth work in any type of soil (soft / loose / hard / dense)all asshown on drg No TD-309 Sheet Nos 1/4 to 4/4 complete all as specified and directed. |
| 76 | M&L for rendering 15mm thick on fair faces of Brick work or concrete surfaces in cement mortor 1:6 finished even & smooth w/o using extra cement complete all as specified and directed. |
| 77 | S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 78 | M&L for preparation of new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed |
| 79 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed |
| 80 | Providing and fixing concertina coil fencing with punched tape concertina coil 450mm dia, 6 metre length, having 50 Nos rounds per 6 metre length, 125 to 127 Clips, spring core wire (2.5 mm thick) of high tensile strength of 165kg/sq.mm with tape (0.52mm thick), weight of each concertina coil not less than 8.4 Kg and fixing the same on existing Y-shaped angle iron, stud tied with G.I. staples and G.I.clips to retain horizontal, including necessary bolts, complete all as specified and directed |
| 81 | M&L for providing, cement concrete type B1 1:2:4 (20mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed. |
| 82 | S&F skylight polycarbonate sheet thickness not less than 2mm at roofs, windows top, duct covering or at any other location using self drilling screw and washer, nut & bolt, staple pins or any other suitable means complete all as specified and directed |
| 83 | M&L for point wiring with 1.5 Sqmm (nominal cross section area) single core, multi stranded PVCinsulated, unsheathed copper conductor, FR cable in and including in rigid pvc conduit 20 mm dia or higher medium grade ISI marked complete with all PVC Conduit accessories / fittings and sunk pressed (1.2 mm thick) steel terminal switch boxes with 3 mm thick plastic laminated hard glossy surface sheet top cover, including earth wire continuous of PVC insulated, unsheathed 1.5 Sqmm copper conductor, PVC insulated connected to all fittings, sunken boxes and common earth, earth dolly. Plastic sheet screwed with brass screws, cup washers complete all as specified and directed for the following:- |
| 84 | All as described ser item no 83.00 here-in-before but one light/exhaust/ fan pointcontrolled by one, one way switches 5/6 Amps. |
| 85 | All as described ser item no 83.00 here-in-before but one 3 pin 5/6 Amps socket outet point onsame board, controlled by one, one way 5/6 Amps switch. |
| 86 | All as described ser item no 83.00 here-in-before but using 2.5 Sqmm copper conductor cable with 2.5 sqmm earth wire for one 15 amps socket outlet on independent board all as directed. |
| 87 | S & F Switch piano flush button single pole one way 5 amp complete all as specified and directed. |
| 88 | S&F switch piano flush type 15/16 Amps songle pole , one way 240 volts complete all as specified and directed. |
| 89 | S & F Socket outlet 3 pin 5 Amps , flush type complete all as specified and directed. |
| 90 | S&F socket outlet 3 pin , 05/06 Amps and 3 Pin 15/16 Amps (2 in 1 Multipurpose) 240 volts complete all as specified and directed. |
| 91 | S & F ceiling rose, surface type, bakelite, 65 x 50 mm, three terminal complete all as specified and directed. |
| 92 | S&F LED lamp 9 W 6500k,240V complete all as specified and directed. |
| 93 | S & F lamp holder insulated body with back plate fix done anodised 100 x 100 mm pressed steel box flush to the wall with 3 mm thick backlite cover complete all as specified and directed. |
| 94 | S&FLED tube light fitting T/5 surface mounting poly carbonate 240 volts 20 watts, 6500K complete all as specified & directed. |
| 95 | M&L for Building security light fitting 1 x 35 LED type, drawn through and including GI bracket of size 25 mm dia bore light grade 1.4 mtr long, bend to shape including MS clamps made out of flat iron of size 32 x 4 mm - 02 Nos and necessary nuts, bolts, washer as required complete all as specified and directed. |
| 96 | S&F Exhaust fan steel body AC single phase 230/240 V size 300 mm sweep with blades , and ;ouvers including hole and plastering complete all as specified and directed. |
| 97 | Supply Install and testing water heater vertical type 50 Ltrs capacity having stainless steel inner tank with glass enamelled coating BEE 5 star rating , closed /ventilated , 240 volts glass coated heating element complete complete with all accessories , including fixing arrangement with suitable size of fastner , nuts, bolts and washers etc incl making good disturbed surface with plaster in CM 1:4 complete all as specified and direcetd. |
| 98 | S&F sheet metal enclosure single pole & neutral for 240 volts 8 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and directed. |
| 99 | S&F MCB single pole 240 volt 6 to 32 amps 10 KA complete all as specified and directed. |
| 100 | S&F MCB SPN 40 Amps , 240 volts , 50 HZ suitable for fixing in MCB DB \"C\" Curve series complete all as specified and as directyed. |
| 101 | M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wite 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point complete all as specified and directed. |
| 102 | M & L Gun metal gate valve with iron wheel head screwed both ends for iron pipe including testing of following :- |
| 103 | All as described ser item no 102.00 here-in-before but 25 mm dia bore complete all as specified and directed. |
| 104 | Cutting of existing CI pipes and reducing to required length before laying in position for insertion of new tees,branches etc complete all as specified and directed of size 150mm dia bore complete all as specified and directed. Note :- Fittings will be measured and paid foe separately under respective items |
| 105 | S & F GI tubing,medium grade,ISI marked complete with all fittings laid in trenches or laid under floors,fixed on walls on walls with and providing clamps etc complete all as specified & directed for the following :- |
| 106 | All as described ser item no 105.00 here-in-before but 25 mm dia bore complete all as specified and directed. |
| 107 | M & L for Sand cushioning for under ground cable upto 8 cm before laying the cable and 15 cm after laying and stretching the cable complete all as specifiedand directed. |
| 108 | M&L for sub class \"B\" bricks well burnt of size laid dry flat for protection of cable complete all as specifiedand directed. |
| 109 | Supply and laying in trenches through pipe or under culvert ofXPLE insulatedPVC sheathed heavy duty 1100 volts grade of size 16 sqmm, 4 core with stranded aluminium conductorincluding proper connection to LT panel /bus bar withaluminium thimbles of suitable size /ratingand taking down the old unserviceable cable complete all as specified and directed Note – necessary excavation, returning filling,removal of soil ,sand cushioning,brick work and GI pipeshall be measured and paid under respective item of Sch. |
| 110 | M & L for GI pipe ( Light grade ) for protection of LT cable fixed to walls/ poles/road crossing including suitable size clamps complete of size 40 mm bore , complete all as specified and directed. |