Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-01-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-01-2026 |
| Sl. No. | Item Description |
| 1 | Dismantling of existing roof treatment of any description/thickness including dismantling of water proofing plaster etc complete all as specified and directed. |
| 2 | M&L for PCC 1:2:4,type B-0, using 12.5mm graded stone aggregate coping, benching, roof padding as levelling course complete all as specified and directed. |
| 3 | M&L for 15 mm thick plasteringin CM 1:4 on brick/concrete surfaces of roof and parapet, mixed with water proofing compound as per manufacturer\"s instructions, finished even and smooth without using extra cement (Including 4 Story building) complete all as specified and directed.Note :- Water proofing compound shall be measured & paid separately. |
| 4 | Supply only liquidwater proofing compound complete all as specified and directed. |
| 5 | Cleaningtop surfaces by brooming, wire brushing, removing grass, raking out joints to receiveplaster and removing debris, grass etc outside the defence landcomplete all as specified and directed. Note :-1. Plaster shall be measuredandseparately under appropriate item of Sch ‘A’.2.Rate of this item is inclusive of diconnectfitment at water tank orsolar heater etc and refixing in the same position after compeleting of roof treatment. |
| 6 | M&L for applying 3.00mm thick APP based polymer membrane over 85/25 industrial bituminous coat @ 3.5 Kg/Sqm over bituminous primer @ 0.30 Ltr/Sqmon newly plastered clean and dry roof surface. Top surface shall be finished with bituminous base Aluminium paint,all joint shall be Sealed by torch application complete all as specified and directed. |
| 7 | Demolition of brick masonry, built in cement mortar of any description complete all as specified and directed. |
| 8 | M&L for brick work with sub class \"B\" old size bricks straight or curved on plan any radius built in cement mortar 1:6, complete all as specified and directed. |
| 9 | M&L for 5mm thick rendering in CM 1:3 on concrete/gunniting surface as in ceiling finished even and smooth w/o using extra cement incl taking down cement plaster or concrete, brick surface and raking out joints hacking for key scrubbing down with water to receive plaster. complete all as specified and directed. |
| 10 | M&L for preparing old distempered surfaces of wall by complete removal of the existing treatment and applying two coats of oil bound distemper over a 1 mm thick uniform wall putty by using roller complete all as specified and directed by Engr-in-charge. |
| 11 | M&L for preparing the old decorated plastered or un-plastered surfaces of ceilingby brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot and applying two coat of white wash by using roller complete all as specified and directed. |
| 12 | M&L for preparing the old decorated surfaces of wall, pillasters, cornices etc by complete removal of the existing treatment and applying one coat of apex exterior paint duly adding pigments to required colourfilling all the holesand making uniform, smooth surfaceby using roller/usingsmart periodical methodologycomplete all as specified and directed by Engr-in-charge. Note:-The work for periodical services shall include the following and the rates quoted by the bidders shall include the same :-(a)The work pertaining to periodical services shall be executed by the contractor as per MoU from authorized applicator through manufacturer of the materials like Exterior Emulsion paint, putty etc after approval by the GE.(b)The Contractor shall submit the documents “Memoradum of Understanding” (MoU) before commencement the subject work with atleast one of the manufacturers mentioned in the contract documents.(c)Use of Scaffolding, trestles, ladders, cradles etc necessary for execution of work and protective measures as per site requirement.(d)Removing of nails, making good holes, cracks etc as per site requirement.(e) Work in patches and in narrow / widths, bands, cornices, plasters etc and cutting in edge of line where necessary.(f)Spreading and removing covering to doors, windows, floors, fittings etc to protect them from splashes.(g)Washing floors, cleaning glass, joinery, electric fittings, wirings etc. Drops and splashes of paint to be cleaned to the entire satisfaction of Engineer-in-Charge.(h) Removing and existing furniture for painting work and replacing the same post painting work, movable cupboard, chicks, blinds etc.(j)Sample patch of 10 Sqm be prepared considering all the items of periodicals and shall be got approved from GE prior to carrying out further subject work.The work for periodical services shall include the following and the rates quoted by the bidders shall include the same :-(k) GUARANTEE OF PERIODICAL SERVICES: Periodical services against item No 12 of BOQ using mechanized equipment’s only executed under this contract are under the guarantee of contractor for 05 (Five) Years after the certified physical completion of work. Contractor is fully liable under this guarantee to rectify and redo all defective work intimated to him during this period including all type of materials and labour to the specifications catered for in the contract. In case contractor fails to rectify the defective work, Accepting officer shall get the rectification done as necessary at the risk and cost of contractor and recover the cost in full from the contractor. If the contractor consider that any additional treatment is required over and above that specified here in before in Schedule ‘A’, the same shall be carried out by the contractor without any extra cost to the Government. |
| 13 | M&L for preparation of oldpainted wooden surfaces over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of white lead primer complete all as specified and directed. |
| 14 | M&L for preparing old distempered surfaces of ceiling by complete removal of the existing treatment and applying two coats of oil bound distemper over a 1 mm thick uniform wall care putty by using roller complete all as specified and directed. |
| 15 | M&L for complete removal of existing treatment and applying two coats synthetic enamel paint over a coat of red oxide/zinc chrome primer including preparation of Old steel/iron surfaces exc 10cm in width or girth up to 4 storey building complete all as specified and directed. |
| 16 | M&L for applyingtwo coats ofAcrylic smooth exterior emulsion paint over one coat of acrlic primerfor exterior/interior on New scraped wall surfaces and obtain smooth finish using sand paper complete all as specified and directed. |
| 17 | M&L for 75 mm thick PCC 1:4:8 type D2 (40mm graded stone aggregate) complete all as specified and directed. |
| 18 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to the stores and rubbish off the premises complete all as specified and directed. |
| 19 | M&L for premium quaility Glazed ceramic coloured tiles in vertical surface 350 x250x 7 mm/ 450x 350x7 mmthick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar 1:4, complete all as specified and as directed. |
| 20 | M&L for premium quaility Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match Laid on floor, over and including 15mm thick screed bed in cement mortar 1:4, complete all as specified and as directed. |
| 21 | M&L Machine pressed precast concrete inter locking paver block any shape and size with Grey cement and no pigment conforming to IS 15658-2006 of 60mm thickness , M-35 Grade complete all as specified and as directed. |
| 22 | M&L for refixing old interlocking paver block over & incl 25mm thick Sand Cushioning complete all as specified and directed. Note : Old tiles retrived from dismantling shall be reused. |
| 23 | M&L rendering 15mm thick in cm 1:6 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cementincl taking down cement plaster or concrete, brick surface and raking out joints hacking for key scrubbing down with water to receive plaster etc, complete all as specified and directed.Note: The work to be executed at the hieght of 12 to 15 mtr & the rate for necessary scaffolding deemed to be included in the qouted rate. |
| 24 | M & L for sand filling under floors or in foundationincluding watering and consolidation complete all as specified and directed. |
| 25 | Demolition of Cement Concrete (un-reinforced) of any description, not exc. 150mm thickness (above or below Ground Level) and removing the same from Site(s), complete all as specified and as directed. |
| 26 | S&F MS work as in post and strut and fencing, drilled and countersunk for balusters running bars for doors balusters,noising to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts,posts and struts in fencing including cutting tops to shape as directed drilling hoes nothcing for wire etc flat iron fillets ( for securing wire mesh ) including all necessary drilling bolting or riveting etc. and similar work conformingto Fe - 290 Gde E - 165complete all as specified and directed. |
| 27 | S&F in repairs 500 Litre capacity of rotational moulded polyethylene water storage tank (Cylindrical vertical with closed tap) hoisted and fixed in position including S&F 20 mm dia GI pipe medium grade washout pipe 450 mm long with plug ;and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings and including dismantling of tank, pipe etc, complete all as specified and as directed. |
| 28 | S&F 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high densityplastec ball screwed for iron pipe and fixed complete all as specified and directed. |
| 29 | Taking up or down existing steel tubing/PPR pipe and connections including cleaning for refixing or removal to store complete all as specified and as directed for the following sizes:- (a) 15mm dia bore |
| 30 | All as per item No 29 above 20 mm dia bore |
| 31 | Supply & fixing, jointing and testing galvanized iron tube medium grade with all fittings such as bends, elbow, socket, reducer etc and fixed to wall, ceiling or laid in floors for the following sizes:- (a) 15mm dia bore |
| 32 | All as per item No 31 above 20mm dia bore |
| 33 | M&L in repair Vitreous China White Wash down Water Closet Pan (Pedestal Pattern) P & S type including Bolts, (excluding Flushing Cistern and Flushing Pipe) with white Plastic Seat cover, with Recessed Bottom closed pattern and Cover including Mild Steel Chromium Plated Aluminium Hanging Device and fixed-in-repairs, including Making Good disturbed Surfaces with Cement Mortar 1:3, complete all as specified and as directed. |
| 34 | S&F in repair PVC Flushing Cistern 10 LITRE capacity, Low Level Valve Less, Symphonic Action type, White, with Inlet, Ball Valve, Float and Handle including a Pair of Cast Iron Brackets duly Painted/Erecting Stand and PVC connection pipe 15mm size, PVC Flush Pipe of polythene 32mm dia for Low Level Flushing Cistern including Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 and fixed including Taking down/out Unserviceable Flushing Cistern and connected Items, complete all as specified and as directed. |
| 35 | S&F in repair Vitreous China Wash Hand Basin 630X450mm in size, White (Flat Back Type) with 32mm dia Brass Chromium Plated Waste Fitting,UPVC Bottle trap, UPVC’ 32mm bore Waste Pipe, a Pair of Cast Iron Brackets duly Painted/ Erecting Stand including Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 and fixed including Taking down Unserviceable Wash Hand Basin and connected Items, complete all as specified and as directed. |
| 36 | S&F in repair looking mirror 750x600x6mm thick selected quality glass mounted on 25mm size SS Stud fixed with CP brass screws complete all as specified and directed. |
| 37 | S&F in repair High pressure PVC connections pipe 600mm long suitable for 15mm size with Brass CP Check nut complete all as specified and directed. |
| 38 | S&F in repair SS Chromium Plated Towel Rail 600mm Long, as Approved, fixed including Taking down un serviceable Towel Rail of any description, complete all as specified and directed. |
| 39 | S&Fin repair Angle Stop Cock 15mm Bore (dia), Chromium Plated, screwed down, screwed for Iron Pipe or for Brass Ferrule and fixed-in-repairs complete all as specified and directed. |
| 40 | S&F in repair Bib Cock 15mm Bore (dia), Chromium Plated Long Body Bib Cock, screwed down, screwed for Iron Pipe or for Brass Ferrule and fixed-in-repairs, complete all as specified and directed. |
| 41 | S&Fin repair brass CP fency Pillar Taps 15mm Bore, Cast Copper Alloy with Capstan Heads, screwed down high pressure with or without lettered ‘HOT’ or ‘COLD’ with long screwed Shanks and Fly-Nuts, screwed for Iron Pipe and fixed-in-repairs, complete all as specified and directed. |
| 42 | S&Fin repair Liquid Soap Dispensor with holder,fix in wall with Brass Chromium Plated Screws including Taking down unserviceable Soap Dish/Dispensor of any description, complete all as specified and directed. |
| 43 | Taking down door/window frame with shutter of area n exc 1.50 sqm each and removing to store complete all as specified and directed. |
| 44 | Taking down shutters only of size exc 1.00 Sqm but not exceeding 2.00 Sqmcomplete all as specified and as directed. |
| 45 | M&L for 35mm thick block board flush shutter with 0.90mm thick Sun Mica/lamination on both sides and 2nd class hard wood lipping alroundfixed in position and fixed to chowkats complete all as specified and directed. |
| 46 | S&F 150mm long Aluminium anodised handles, cast type complete all as specified and directed. |
| 47 | S&F 200 mm long aluminium anodized barrel tower bolt of extruded section complete all as specified and directed. |
| 48 | S&F Mild Steel Butt Hinges 100mm, Medium Weight, Cold Rolled ISI Marked and fixed, complete all as specified and as directed. |
| 49 | M&L for guniting RCC works in coloum, beams, slabs, ceiling, Chajjas, Facia, landing, balconies etc by removing loose concrete including plaster, cleaning of surfaces with wire brushes and supply and fixing welded steel wire mesh 50 mm x 25 mm with 3 mm dia steel wire as facias/drops and similar works etc and applying one coat epoxy resin concrete bonding agent over the old concrete surface to bond with the new concrete with Nitobond EP of M/s Pidilite/M/s BASF (as per manufacurers instruction) to bond old and new concrete, gunniting with minimum pressure of 2.5 Kg per Sqcm in two layers of total avg thickness shall be40 mm thick with cement mortor (1:2) using OPC cement of 43 grade mixing with water proofing admixture polycrete @ 2% by weight of cement complete all as specified and directed by Engr-in-Charge. Note :The following items shall be deemed to be included in quoted rate(i) Reinforcement bars and plastering to guniting surface (ii)After placing the reinforcement all concrete surface shall be throughly scrubbed with brush, washed with water and allowed to dry for plastering(iii) Work is to carried out in patches(v) Rate for scaffolding etc shall be deemed to be included in quoted rate for up to four Storey.(iv) Guniting at Ground floor to 4 th story(v) Anti-corrosive protective coating for reinforced bars (vi) Two coat oil bound/Apex over a coat of primer over guniting including putty(vii)15 mm plaster in CM 1:4shall be done on Guniting area |
| 50 | Taking down existing steel rolling shutters size not exceeding 2.50m x3.00m with all connecting items and repair/replace the lath of steel rolling shutters and locking arrangements, greasing, tightening of helical wire spring including welding wherever required, oiling, etc.complete to make in serviceable condition including gear box lock bearing etc and applying two coat of synthetic enamel paint including preparation of old painted surfaces and refixing in the same opening complete all as specified and directed. |
| 51 | Dismantling plain or corrugated steel sheeting,any guage, any thickness,including nainital or similar pattern roof coverings complete all as specified and directed. |
| 52 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and complete all as specified and directed. |
| 53 | M&L for anodised aluminium framed workfor door, window / vent (powder coated)aluminiumwith one or more rebated incl jointed cleat for fixing etc complete all as specified and directed. |
| 54 | M&L for anodised aluminium powder coated window and ventilator shutters, aluminium section weighting not less than 0.55kg/RMincl necessary 4.8mm th sheet glass ordinary quality glass/ frosted incl joining with cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, lock , 2 x 150mm aluminium handles, 3 x 100mm hinges aluminium, 2 x 150mm Aluminium tower bolts complete all as specified and directed. |
| 55 | S&F aluminium wire guard mesh of 4mm nominal dia of wire and average width of aperture 75 - 85mm and fixed with aluminium frame / staples complete all as specified and directed. |
| 56 | M&L for 4.8 mm thick float glass ordinary quality\" frosted glass and glazing with aluminium beading and gasket to aluminium frameworkin squareexc 0.50 sqm ineach pane in repair complete all as specified and directed. |
| 57 | S & F for stainless steel wire cloth 0.36mm nominal dia of wireand average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beads complete all as specified and directed. |
| 58 | S&Fin repair 32mm Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm-45gms/40mm-60 gms complete all as specified and directed. |
| 59 | Removing debris material to a distance exceeding 1.5KM butnot exceeding 5 KM and depositing where directed at a level n. exc 1.50 m above the starting point complete all as specified and directed. |
| 60 | Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed. |
| 61 | Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cmapart complete all as specified and directed. |
| 62 | Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. |
| 63 | Material and labour for sand cushioning to XLPE cable with using clean dry and natural river sand with a layer of 8 cm thick before laying the cable and 15 cm thick layer after laying the cable and this then gently punned down to a thick of 10 cm above the top the upper most cable complete all as specified and directed. |
| 64 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm complete all as specified and directed. |
| 65 | Supply,Laying,Connecting and testing in repairs cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 35 Sqmm 3.5 core complete all as specified and directed. |
| 66 | Taking down carefully aluminum/copper point wiring (light, fan, switch, socket, power point, holder) complete includind fittings and fixturesand making good disturbed surfaces of walls, floor to match with existing specification keeping aside serviceable items for reuse within the same bldg and removing U/S items from site complete all as specified and directed. Note : Refixing of serviceable fitting shall be measured and paid seperately. |
| 67 | Taking down carefully copper / aluminum sub main wiring of sizes 4/6 Sqmm cable any type and removing old material from site and making good disurbed surface complete all as specified and directed. |
| 68 | M&L for two single core PVC insulated cable with copper conductor multi stranded 4 Sqmm duly drawn through and including concealed PVC conduit 25 mm dia medium grade ISI marked as sub main with continuous earth wire 2.5 Sqmm and connecting to common earth dolly complete all as specified and directed. (Flexible Copper Wire Used In FRLS) Note : 3 runs of 4 Sqmm cable and one run of PVC conduit will be measured as one running meter for the purpose of measurement and payment. |
| 69 | M&L for point wiring complete with 1.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade FRLS cable IS-694 marked drawn throughand including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, fixed in wall, on roof with GI saddles GI screws, rawal plugs (concealed conduit in wall wiring) with all fittings including Tee, junction boxes and provision of2 mm thick pressed steel terminal box of suitable size with 3 mm thickhylamlaminated white sheet cover for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multistranded coper conductor of size 1.5 Sq mm (Nominal area) complete all as specified for following (Color coding to be followed) |
| 70 | Allas per ItemNo 69 above but one three pin 5 Amps socket out let on the same boardwith other switches. |
| 71 | Allas per itemNo 69 above but one three pin 5 Amps socket out let on independant board. |
| 72 | Allas per item No 69 above but 15 Amps3 pinsocket outleton independent board with 2.5 sq mmPVC insulated and sheathed copper conductor with 2.5 sq mm PVC insulated copper conductor single corefor continuous earthing complete. |
| 73 | S&F Piano switch, flush button,single pole,one way 5/6 Amp complete all as specified and directed. |
| 74 | S&F piano switch, flush button single pole one way 15/16 Amp complete all as specified and directed. |
| 75 | S&F socket outlet, flush type 2 in 1, 2 pin and 3 pin 5 Amp complete all as specified and directed. |
| 76 | S&F socket outlet, flush type 2 in 1, 3 pin and 6/16 Amp complete all as specified and directed. |
| 77 | S&Fstepped type electronic fan regulator,flush type on the existing phenolic laminated sheet etc complete all as specified and directed. |
| 78 | S&Fin repairs,ceiling rose surface backlight, 65 x 50 mm two to to three terminals complete all as specified and directed. |
| 79 | S & F flush type electronic fan regulator ,on the existing phenolic laminated sheet etc complete all as specified and directed. |
| 80 | S&F in repairs,LED tube light batten,9/10W(+) 2% LED 6000K (2 ft.), 230 volts AC,Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed. |
| 81 | Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 8\"x10\" complete all as specified and as directed. |
| 82 | S&F in repairs,sheet metal enclosure for MCB DB\"s SPN 240 volts, 4 way with neutral bus bar 200 Amp rated double door type regal grey complete all as specified and directed. |
| 83 | S&F in repairs MCB SP 6 to 32 Amps 240 Volts.\"B\" grade complete all as specified and directed. |
| 84 | S&F in repairs MCB SPN, 40 Amps, 240Volts .\"B\" grade complete all as specified and directed. |
| 85 | Supply and fixing in replacement of LED building security light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 86 | S& fixing LED flood light luminarie120 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed.Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost to height upto 25 mtr |
| 87 | S&F in replacement street light GI pipe bracket 50 mm dia 1.50 metre length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc complete all as specified and directed. |
| 88 | M&L for earthing complete for pole with galvanized mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtr below ground level connected by using galvanised iron strip 25 X 4mm as earthing lead size by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 40mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, all excavation and earth work & connectiing the earthing to an earthing test point as specified and testing on complete all as specified and directed. |
| 89 | Supply and fix in repair aluminium strip 25 mm x 3 mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground level including removing u/s strips complete all as specified and directed. |
| 90 | Supply and fix single pointed air termination aluminium rod,12 mm dia, 300 mm long complete all as specified and directed. |
| 91 | S&F porcelain strip holder on wall and roof of suitable size including removing broken u/s one complete all as specified and directed. |
| 92 | M&L 32 mm dia GI pipe light grade of 1.3 mtr long fixing in PCC cubical and complete connection of existing air termination rod complete all as specified and as directed, |
| 93 | M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping and necessary form work, weathering slightly rounded or chamfered angles and throating etc complete all as specified and directed. |
| 94 | M&L for CI plate triangular with 500 mm long spike for writing earthing name and value complete all as specified and directed. |
| 95 | Supply and fixing in replacement of Retro reflective sign board of size 900 mm X 1200 mm made of ACP sheet of 3 mm thick. ACP Sheet will be fixed on SS (Stainless Steel ) frame of with legs of Stainless steel (SS) on PCC 1:3:6 type 2.10 m aboveThe ground level and 750 mm below the ground level. The background of board to be provided with blue colour, letters and border with white retro reflective tape. Same description will be mentioned on both side of ACP Sheet.The size of letters and description will be as per directed by Engr-in-charge, board will be complete fixing/grouting with nut/bolts/Anchor fastener with washers. |
| 96 | Supply and fixing in replacement of Retro reflective sign board of size 600mmx1800mm made of ACP sheet of 3 mm thick. ACP Sheet will be fixed on wall , The background of board to be provided with blue colour, letters and border with white retro reflective tape. Same description will be mentioned on one side of ACP Sheet.The size of letters and description will be as per directed by Engr-in-charge, board will be fixed on Wall complete fixing/grouting with nut/bolts/Anchor fastener with washers complete all as specified and directed. |
| 97 | M&Lfor providingDisplay board of size 1m x 1m x1 cm madeup with acrylic sheetmaterial consisting of\"First Aid discription with pictures \" in Capital Letterat the Top complete with fixing arrangements to the wall complete all as specified and directed. |
| 98 | M&Lfor providingDisplay board of size 1m x 1m x1 cm madeup with acrylic sheetmaterial consisting of\"First safety instruction with fire extenguishing methods with pictures \" in Capital Letterat the Top complete with fixing arrangements to the wall complete all as specified and directed. |
| 99 | M&Lfor providingDisplay board of size 1m x 1m x1 cm madeup with acrylic sheetmaterial consisting of\"Safety instruction in case of electric shock with fire extenguishing methods with pictures \" in Capital Letterat the Top complete with fixing arrangements to the wall complete all as specified and directed. |
| 100 | M& L for preparationof trench for cable laying of size 300mm x 450mm x 10 m long including excavation & earth work in any type of soil brick work in CM 1:4, PCC work in 1:2:4 type B-1 using 20mm graded stone aggregate, plaster in CM 1:4 finished even & fair complete all as specified and directed. |
| 101 | Supply and fix cable duct cover made of MS of size 320mm x 800 mm of thickness 3.0 mm complete all as specified and directed. |
| 102 | S & F rubber insulation mat of size 1.8 mtr x0.9mtr wide 2 mm thick red/blue colour ISI marked embossed for up to 33 KV as per latest IS complete all as specified and directed. |
| 103 | Supply,Laying,Connecting and testing in repairs cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 120 Sqmm 3.5 core complete all as specified and directed. |
| 104 | All as above item No 103 above but Size 70 sqmm 3.5 core. |
| 105 | All as above item No 103 above butSize 50 sqmm 3.5 core |
| 106 | All as above item No 103 above but Size 95 sqmm 3.5 core |
| 107 | All as above item No 103 above but Size 25 sqmm 4 core |
| 108 | All as above item No 103 above but Size 16 sqmm 4 core |
| 109 | All as above item No 103 above but Size 10 sqmm 4 core |
| 110 | Supply and Fix cable jointing kit,heat shrink type for 1100 volts grade,XLPE insulated armoured heavy duty electric cable with aluminium conductor,cross sectional area 6-16 Sqmm 4 core complete with jointing material and accessories including testing complete all as specified and directed. |
| 111 | All as above item No 110 but Size 25-35 sqmm 4 core complete. |
| 112 | All as above item No 110 but Size 50-95 sqmm 3.5 core complete |
| 113 | All as above item No 110 but Size 120 - 185 qmm 3.5 core complete. |
| 114 | S & F in repairs Earth test box made of powder coated, 3.15 mm thick, CRCA sheet,20 cm x 20 cm x 10 cm size conforming to CPRI approved and IP-65 protection class,right hinge openable type including mounting arrangement such as making hole in wall,providing MS clamp,nut,bolt etc complete manufactured through approved manufacturers complete all as specified and directed. |
| 115 | S&F in repairs MCCB 3 pole 415 volts fixed type 160 Amps with braking capacity 36KA after taking out old U/S one complete all as specified and directed. |
| 116 | S&FMCCB 3 pole 415 volts in repairs,fixed type 63 Amps to 100 Amps with braking capacity 16 KA.after taking out old U/S one complete all as specified and directed. |
| 117 | S&F in repairs MCCB 3 pole 415 volts fixed type 200Ampswith braking capacity 36KA after taking out old U/S one complete all as specified and directed. |
| 118 | S&F in repairs MCCB 3 pole 415 volts fixed type 250Ampswith braking capacity 36KA after taking out old U/S one complete all as specified and directed. |
| 119 | S&FMCCB 3 pole 415 volts in repairs,fixed type 100 Amps with braking capacity 16 KA.after taking out old U/S one complete all as specified and directed. |
| 120 | S&F in Repairs Contactor, (4 Pole AC & DC Control) operational current AC1,160 Amps,poles composition- 4NO,DC control ref-LP1D80004 of TC complete all as specified and directed. |
| 121 | S&F in Repairs Contactor, (4 Pole AC & DC Control) operational current AC1,125 Amps,poles composition- 4NO,DC control ref-LC1DT125A of TC complete all as specified and directed. |
| 122 | S&F MNX 18, 3 pole contractor,2 NO+ 2 NC,415 volts AC, confirms to IS/IEC 60947 -4-1, in existing model and make including after taking out old unserviceable one, complete all as specified and directed. |
| 123 | S&F MNX 95, 3 pole contractor,2 NO+ 2 NC,415 volts AC, confirms to IS/IEC 60947 -4-1, in existing model and make including after taking out old unserviceable one, complete all as specified and directed. |
| 124 | S&F MNX 70, 3 pole contractor,2 NO+ 2 NC,415 volts AC, confirms to IS/IEC 60947 -4-1, in existing model and make including after taking out old unserviceable one, complete all as specified and directed. |
| 125 | S&F MN contactor 18 Amps in existing model and make ncluding after taking out old unserviceable one, complete all as specified and directed. |
| 126 | S& F Panel LED indication lamps (R/Y/B) complete all as specified and as directed. |
| 127 | S&F Rotary switch as per make L&T complete all as specified and as directed. |
| 128 | S&F in repairs digital volt meter ,415 volts,including after taking out old unserviceable one complete all as specified and directed. |
| 129 | S&F in repairs digital Ammeter,415 volts grade,100 Amps rating,including and after taking out old unserviceable one complete all as specified and directed. |
| 130 | S& F in capacitor 3 phase, 5 KVAR complete all as specified and as directed. |
| 131 | S& F in capacitor 3 phase, 10 KVAR complete all as specified and as directed. |
| 132 | S& F in capacitor 3 phase, 25 KVAR complete all as specified and as directed. |
| 133 | S& F in capacitor 3 phase, 2 KVAR complete all as specified and as directed. |
| 134 | S& F in capacitor 3 phase, 3 KVAR complete all as specified and as directed. |
| 135 | Supply and install reactive power manager in existing APFC panelcomplete all as specified and as directed. |
| 136 | M&L for servicing/testing of APFC (Automatic Power Factor Control) panel including checking of all internal connetions and replacement of spares if required complete all as as specified and as directed.Note - Spares to be measured and paid separately |
| 137 | M & L for High quality powder coating on electric panels (Cubicle) installed at different places with synthetic enamel paint of suitable colour including and after scrubbing all body surface to get all foreign particles removed off,applying one coat of metal primer by disconnecting,removal of all accessories like bas bar, CTs,MCCBs and all wirings,equipments and refix with new Gun metal nut,bolt and washer complete with new copper lead wiring complete all as specified and directed. |
| 138 | Boring of Holes under road, Pavement, hard Standing by trenchless technology using ultra Sound technique and necessary machine withHDPE Pipe, PN 10,100 mm dia complete all as specified and directed. |
| 139 | Supply, laying and fixing in position in repairs galvanized iron pipe 80 mm bore light grade fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenchesduly painted with two coat of black metallic paint after aprimer coat of red oxide complete all as specified and directed. |
| 140 | All as per item No 139 above but 50 mm dia. |
| 141 | All as per item No 139 above but 40 mm dia. |
| 142 | M&L for Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access free standing/Wall mounted, dust and vermin proof (IP 65 ingress protection), CPRI tested type main LT Panel(Out door type) of approx size 600 x 600 x 350mm suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of 50 KA for 1 sec , fabricated from 3.15 mm thick CRCA sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement mounted on angle iron frame made out of 50x50x6 mm frame with 6 nos legs not less than 45 cm fixed with nuts bolts of suitable size,including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below. LT Panel shall have provision for entry of cables from the top or bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position. Suitable arrangement shall be made for termination of multiple incoming cables. INCOMER :(i) MCCB 250 Amp, 35 KA, 4 pole 415 volts.1 No (adujstable) (incoming), (II) Digital Volt Meter (0-500V) =01 No.,(iii) Digital Amps Mtr (0-200)=01 No.with suitable CT rating(iv) Selector Switches-02 Nos (3 phase volt meter,3 phase Ammeter), (v) Lamp LED,220 Volt, - 03NosOUTGOING : (i) MCCB 125 Amp, 25 KA, 3 pole 415 volts - 02 Nos (adujstable)(ii) MCCB 63 Amp, 16 KA, 4 pole 415 volts - 03 Nos (adujstable)Note : (i)MCCBs shall have adjustable thermal setting. (ii) All kA values indicated shall be Ics breaking capacity. (iii) General Arangement drawings shall be got approved by GE before fabrication. (iv) The rate for necessary civil work PCC for foundation etc is deemed to be included in quoted rate. |
| 143 | M&L for Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access free standing/Wall mounted, dust and vermin proof (IP 65 ingress protection), CPRI tested type main LT Panel(Out door type) of approx size 600 x 600 x 350mm suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of 50 KA for 1 sec , fabricated from 3.15 mm thick CRCA sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement mounted on angle iron frame made out of 50x50x6 mm frame with 6 nos legs not less than 45 cm fixed with nuts bolts of suitable size,including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below. LT Panel shall have provision for entry of cables from the top or bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position. Suitable arrangement shall be made for termination of multiple incoming cables. INCOMER :(i) MCCB 250 Amp, 35 KA, 4 pole 415 volts.1 No (adujstable) (incoming), (II) Digital Volt Meter (0-500V) =01 No.,(iii) Digital Amps Mtr (0-400A)=01 No.with suitable CT rating(iv) Selector Switches-02 Nos (3 phase volt meter,3 phase Ammeter), (v) Lamp LED,220 Volt, - 03NosOUTGOING : (i) MCCB 125 Amp, 16 KA, 4 pole 415 volts - 03 Nos (adujstable)(i) MCCB 100 Amp, 16 KA, 4 pole 415 volts - 01 No (adujstable)Note : (i)MCCBs shall have adjustable thermal setting. (ii) All kA values indicated shall be Ics breaking capacity. (iii) General Arangement drawings shall be got approved by GE before fabrication. (iv) The rate for necessary civil work PCC for foundation etc is deemed to be included in quoted rate. |
| 144 | M&L for Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access free standing/Wall mounted, dust and vermin proof (IP 65 ingress protection), CPRI tested type main LT Panel(Out door type) of approx size 600 x 600 x 350mm suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of 50 KA for 1 sec , fabricated from 3.15 mm thick CRCA sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement mounted on angle iron frame made out of 50x50x6 mm frame with 6 nos legs not less than 45 cm fixed with nuts bolts of suitable size,including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below LT Panel shall have provision for entry of cables from the top or bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position. Suitable arrangement shall be made for termination of multiple incoming cables. INCOMER :(i) MCCB 400 Amp, 35 KA, 4 pole 415 volts.1 No (adujstable) (incoming), (II) Digital Volt Meter (0-500V) =01 No.,(iii) Digital Amps Mtr (0-400A)=01 No.with suitable CT rating(iv) Selector Switches-02 Nos (3 phase volt meter,3 phase Ammeter), (v) Lamp LED,220 Volt, - 03NosOUTGOING : (i) MCCB 250 Amp, 25 KA, 4 pole 415 volts - 01 No (adujstable)(i) MCCB 200 Amp, 16 KA, 4 pole 415 volts - 01 No (adujstable)(i) MCCB 125 Amp, 16 KA, 4 pole 415 volts - 03 No (adujstable)Note : (i)MCCBs shall have adjustable thermal setting. (ii) All kA values indicated shall be Ics breaking capacity. (iii) General Arangement drawings shall be got approved by GE before fabrication. (iv) The rate for necessary civil work PCC for foundation etc is deemed to be included in quoted rate. |
| 145 | Supply, install, testing, and commissioning in replacementof factory made universel mounted type on wall mounted meter cum distribution board in door type compartmentalized drg, single front door opening , copper busbar of 200 Amp TPN and made of CRCA sheet 1.6 mm thick powder coated of suitable size ofcomprising following assecessories :- (a) MCCB four pole 200 Amp 415 Volt 25 KA (fixed thermal & magnetic setting)-01 No ( incomimg )(b) Indicating Lamp -01 Set ( RYB)(c ) MCB DP 63 Amp 240 Volt 16 KA -20 Nos(d) Space for Metering cubical with front locking devices including tamperd glass -18 No\"s(e)Digital multi function meter (Volt meter 0-500V,Ammeter 0-200A, frequency meter & power factor meter) of size 96mmx96mm with programmable CT ratio with back up protection by 2 A MCB SP.Note :- All House electric Meter remove existing place and to be shifted / fixing in the new panel to supplied by the contractor and cable connecton and other accessorie are to be required at siteincluding this quated rate nothing extra pay for the contractor. |
| 146 | Supply and install and commmissionng of LT bus bar chamber CPRI approved out door type with sloping canopy of size 600x600x600mm made out of 3.15 mm thick CRCA sheet, panel shall be powder coated siemens grey shade mounted on 40x40x6 mm MS angle iron frame 90 cms height erected in ground with PCC foundation 1:4:8 with 40mm stone aggregate including supply and fixing insulated aluminium bus bar of size 50x 6mm for three phase and neutral 200 mm length respectively mounted on insulators and terminating with suitable cable with glands and provision of one MCCB 63 Amps,3 pole ,415 mps, 50 Hz of breaking capacity 25 KA as incomer complete all as specified and directed. |
| 147 | Supply & fix porcelain vitreous LT 1.1 KV bushings withcopper/brass studs suitable for out door distribution transformers of capacity upto 400 KVAafter removing the oldunserviceable studs / bushings and draining out the transformer oil from the top level up to conservator of the transformer and removing the top cover of thecarefully and refixing and refilling the oil all complete all as specified and directed. |
| 148 | M&L forstone aggregate of size not exceeding 40 mm deposited spread and leveled in layers not exceeding 15 cm to a true surface of broken stones for transformer yard andpole structure area complete all as specified and directed. |
| 149 | Surface dressing in hard / dense soilnot exceeding 15 cm deepand clearing all the grass weeds etc in the sub station yards after removing stone aggregate asideall as directed at site including setting / spreading back the aggregate including filling of river sand/ stone dust upto 15 cm complete all as specified and directed.Note:- (i)Stone dust/river sand shall be measured and paid separately under relevant items of this schedule.(ii)The rate also deemed to be included for labour (iii) All the sub station yards shall be kept cleanthrough out the contract period by removing the grass/weeds as many as times required depending on the growth of the grass. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy