| 1 | M&L dismantling boarding , any description fixed with screws in any position , complete all as specified and directed. |
| 2 | S&F5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing, complete all as specified and directed. |
| 3 | S&F 5mm thick plain colour PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site (with decorative design as approved by GE, complete all as specified and directed. |
| 4 | S&F in repair Stainless steel fancy type curtain rod 25 mm dia including end globe/ mountings as approved complete all as specified and directed |
| 5 | S&F SS Brackets, Holders, End supports etc for fancy typecurtain rod 25 mm dia of any colour as approved complete all as specified and directed. |
| 6 | S&F in repairs door closer hydraulically regulated designation No 2, universal type, suitable for door shutter of weight between 36 to 60 Kg of aluminium (Die cast) body complete all as specified and directed. |
| 7 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs /blankets, any thickness, including cover fillets complete all as specified and directed. |
| 8 | S&F 12 mm thick plain Gypsum Board False Ceiling with GI frame including all necessary drilling cutting to fix electric items complete all as specified and directed with following:-(a) GI Grid channel 30x25x20 mm of 24 gauge fixed with rawl plug and screw 450 mm centre to centre alongwith perimeter walls.(b) GI channel made to shape 50x40x40 mm of 24 gauge placed @ 600 mm centre to centre from perimeter at wall except long wall (in one span).(c) GI intermediate runners of size 45x10x10 mm of 24 gauge fixed @ 1200 mm centre to centre leaving frame of one side walls (in other span).(d) GI sheet 25 mm wide and 20 mm gauge suspended fixed with steel fastner to roof ceiling and 1200 mm centre to centre including pluging of RCC Slab. (e) 12 mm thick gypsum board filling joints with POP and finishing complete with two coat of plastic emulsion paint over one coat of primer on ceiling. |
| 9 | Dismantling of floor, hearth, walls, roof tiles including bedding (but not backing), and rubbish off permises complete all as specified and directed. |
| 10 | M&L for 15-16 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. |
| 11 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 12 | M&L for Brick work with fly ash bricks straight or curved on plan exceeding 6 m mean radius complete built in cement mortar 1:6 complete all as specified and directed. |
| 13 | M&L for Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed. |
| 14 | Taking down chowkhat or frames n exc 1.50 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed |
| 15 | Taking down chowkhat or frames exc 1.50 Sqm and n exc 4 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed |
| 16 | Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profiles with wall thickness of 2.3 mm (+-0.2 mm) window profile with hollow section with multi chamber . Frame (60 mm × 58 mm)sash (60 mm × 78 mm). T- Profile (one vertical length in two shutters)(60mm x 74mm)Glazing bead (35 mm × 20 mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2 +- 0.2 mm thick galvanized steel Frame (28 mm × 21.5 mm) sash (31mmx27mm) T- Profile(27mm x 17mm) to be insertedin required profile, frame will be fixed to the wall with 8 mm × 100 mm long fasteners. HARDWARE: (Casement door handle made of zinc alloyed (white coloured coated),corner striker,secondary striker,cylinder,Door transmission gear made of mild steel with multi point locking system with strikes,3D Hinges of Zinc alloyed(white powder coated) and 5mm thick glazing with selected quality glass (Note: The unit rate quoted by contractor include cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose), complete all as specified and directed. |
| 17 | Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor includes cost of glass and includes all other connected accessories.) (Area not exceeding 2.00 sqm) , complete all as specified and directed. |
| 18 | Providing and fixing factory made uPVC white colour fixed or lovoured window/ ventilator made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profileOnevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 +–0.2mm thick,galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with selected quality glass (Note: The unit rate quoted by contractor includes cost of glass and includes all other connected accessories) (Area not exceeding 1 sqm each) , complete all as specified and directed. |
| 19 | S & FPowder coated three track Aluminium sliding window with frame not less than 1.8 mm thick excluding aluminium grill and including 4 mm thick tinted glass, beading & necessary rubber packing, locking & opening arrangement, all fitting and fixture , complete all as specified and directed. |
| 20 | S&F 7mm thick aluminium grills of make \"Decogrill\" model DG 104 surrounded by aluminium \"C\" channel with mesh size 75 X 75mm all as specified and directed. |
| 21 | S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed. |
| 22 | M&L Second class hard woodplain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 23 | S&F Plain, framed,panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board edium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed. |
| 24 | S&F 35mm 1st class teak hardwood plain, framed,panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board edium density, wood particle board with commercial face veneers: supplied and fitted tocomplete all as specified and directed. |
| 25 | S&F Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkat complete all as specified and directed. |
| 26 | S& F Skeleton shutter, open rebated and prepared to receive glass , guaze etc divided into squaresmade with 19 mm thick ply along with 12 mm glass , door spring & mortice lock with 12 mm thick plywood frame with finishing of veneer sheet wit complete polish all as specified and directed |
| 27 | S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed etc complete all as specified and directed. |
| 28 | S&F 150 mm long extruded brass handles, fabricated type polished complete all as specified and directed |
| 29 | S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed |
| 30 | S&F 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed |
| 31 | S&F in repair 75 mmButt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed |
| 32 | S&Fin repair 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed |
| 33 | S&F in repairs 300 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 34 | Hacking out old broken glass (any thickness, size quality or description) form wooden frames or stone, concrete or brick surrounds glazed with oil putty or fixed with beads complete all as specified and directed. |
| 35 | S&F 3 mm thick sheet glass ordinary quality and gazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed. |
| 36 | S&F 3 mm thick figured glass pin headed type and gazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed. |
| 37 | S&FStainless steel wire cloth. 0.36mm nominal dia of wire and averagewidthof aperture1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed. |
| 38 | M & Lfor Cutting holes exc half brick but n.exc one brick in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required |
| 39 | S&F Mild steel works as in hold fasts, clamps, plain angle cleats for securing purlins to wood trusses or rafters, cooler stands and similar small articles conforming to Fe 290 Gde E 165 complete all as specified and directed. |
| 40 | S & F in repair bevelled edge Looking mirror of any size without frame of selected quality glassmounted on wall with chromium plated stainlessscrews complete all as specified and directed |
| 41 | S&F 12 mm thick toughened glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes requiredand pivot at top fancy type SS handle of size not less than 300 mm on both sides of shutter with suitable locking arrangement and all necessary fitting complete all as specified and directed. |
| 42 | Taking down cement plaster any description on brick or stone walls etcincluding raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed. |
| 43 | M&L for Rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) complete all as specified and directed. |
| 44 | M&L for applying 2mm thick Birla / JK Putty in two layers on newly plastered wall surfaces absolutely even and smooth, rubbing with sand paper complete all as specified and directed. |
| 45 | M&L for applying 2mm thick Birla / JK Putty in two layers on old wall surfaces including complete removal of existing wall finish of any type with wire brush, brooming, dusting and finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand paper complete all as specified and directed. |
| 46 | M & Lfor two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50gms/litre, of approved manufacturer, ofrequired shade and colour complete, as per manufacturer\"s specification afterPreparation of plastered surface including a coat of primer on prepared surfaces including, rubbing with sand paper and applyingn. |
| 47 | Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power)complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings i.e removingmaterials to store forkeeping in safe custody or for taking credit (credit for above items should be made for conditions separately )and including making good the disturbed surfaces to match with existing surface and colour shade with proper puttyfor smooth finishing without andulations complete all as specified and directed. |
| 48 | Material and labour for cutting chasing,pinning inbrick/ stone/concrete wallat any height wall cutting and chases for concealedwiring PVC pipe layingof20/25 mmdia pipes,water tubing,etc and making good to facings where required and pointing in cement motor 1:3 to ends or edges of landings,wall surfaces etc,cutting not exc 10 cm girth and including making good the disturbed surfaces to match with existing surface and colour shade with proper putty for smooth finishing with existing wall complete all as specified and directed |
| 49 | Materialand labour for point wiring complete with 1.5 sqmm, PVC insulated, FRLSH type, ISI marked,conforming to IS-694/1990(as amended) unsheathed,multistranded,single core, copperconductor cable 1100 volts grade using approved colour coding drawn through and including PVCconcealed conduit 20/25 mm dia medium grade (MMS) and incliding all accessories such as bend,tee,elbows,reducers,bell mouth tube ends,short pieces & junction boxes with PVC covers etc inwalls / roofs / floors / ceiling etc andincluding cutting, chasing work at any heightwith flush mounting GI sunken boxes having top,bottom,side/back side knockout for conduitentry from any direction made out of 1.2mm thick, 60mm deep for housing modular switches,sockets,fan regulators, Indicators,blank plate etc and incl Providingmodular white cover plate with inner frame suitable as per switch modules andincluding PVC insulated multistranded copperconductor 1.5 sqmm FRLSH type unsheathed (Green colour),single core cable as earth wire connecting to common earth dolly for further connection to ceiling rose and earth terminal and including making good the disturbed surfaces to match with existing surface and colour shade with proper putty for smooth finishing with existing wall complete all as specified and directedfor One light point controlled by one 10amps switch, one way |
| 50 | All as per item no. 49 but forOnefan point controlled by one switch 10 amps, and oneregulator. |
| 51 | All as per item no. 49 but forOneexhaust fan point controlled by one switch 10 amps,one way |
| 52 | All as per item no. 49 but forOne 5 pin 6 amps socket point controlled by one 10 amps switch on independent board . |
| 53 | All as per item no. 49 but forOne 5 pin 10 amps socket point controlled by one 10 amps switch on same board . |
| 54 | All as per item no. 49 but forOne bell/buzzer point controlled by one bell push. |
| 55 | All as per item no. 49 but for One light point controlled by two 2 way switches. |
| 56 | All as per item no. 49 but for point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for One 6 pin 16/20amps socket outlet point controlled by one 16/20 amps switchon independent board |
| 57 | All as per item no. 46 but for One 6 pin 16/20 amps socket outlet point controlled by one 16/20 amps switch on same board. |
| 58 | All as per item no. 49 but for point wiring with 4.0 sqmm and earth conductor of size 4 sqmm complete all as specified and directed. |
| 59 | Supply & fixing modular type switch 10 Amps, single pole,1way,1 module,240V,AC, with small indicatorISI Markedcomplete all as specified and directed. |
| 60 | Supply & fixing modular type switch 10 Amps ,2way,single pole,1 module,240V,AC,with small indicatorISI Markedcomplete all as specified and directed. |
| 61 | Supply & fixing modular type bell push10 Amps,1 module, single pole, 240 volts,AC, with embosing bell simble & indicator, ISI Marked complete all as specified and directed. |
| 62 | Supply & fixing modular type switch 16/20 Amps, single pole,1way,1 module,240V,with small indicator,AC, ISI Marked complete all as specified and directed. |
| 63 | Supply & fixing modular type socket shuttered type 10 Amps, 2/3 Pin combined 2 module,240V,ACISI Marked complete all as specified and directed. |
| 64 | Supply & fixing modular type socket 16/20 Amps, 6 Pin combined shuttered socket 2 module,240V,ACISI Markedcomplete all as specified and directed |
| 65 | Supply & fixing red color lighting indication lamp switch, single pole,240volts,AC,50 Hz suitable for 1 moduleISI Marked complete all as specified and directed. |
| 66 | Supply & fixing modular type step fan speed regulator 120W, 2 module,230volts,AC, 360 degree rotation 1 to 8 steps,ISI Markedcomplete all as specified and directed. |
| 67 | Supply and fix call bell AC, 230 Volts single pole, multi music type best and superior quality,ISI marked, as approved type complete all as specified and directed. |
| 68 | Supply & fix angle lamp holder latest model, insulated PVC out side body and brass inside holder with back plate for batten fittings/bulbscomplete all asspecified and directed. |
| 69 | Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed |
| 70 | Supply & fixdecorative box type 20 watt light fitting, end caps, pre-wired and including providing single/double sideLED tube light (tube rod) white/warm 20 watt-01 Nomade of aluminium extrusion with high efficientLED driver,IP-20, Tube efficiency of 100lm/w, including PVC/Wooden round/square block -02 Nosand connected with LED fitting to ceiling roseand including removing old unserviceable fitting complete all as specified and directed. |
| 71 | Supply and fixing 20 watt LED batten nicolaus glamtubeintegrated design, easy to install,efficency,125 lm/w,PC diffuser and robust housing, high quality materials,pre-wired including providing PVC round/PVC square blocks-02 Nos and connected with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified and directed. |
| 72 | Supply and fixing 36 wattsLED supernovalight fitting high wattage completeLED lighting with high lumen output,environmental friendly,energy efficient, integrated design, easy to install,PC diffuser and robust housing, high quality materials,pre-wired including providing PVC round/PVC square blocks-02 Nos and connected with LED fitting to ceiling rose terminaland incl removing old unserviceable fitting complete all as specified and directed. |
| 73 | Supply and fixing LED 20 watt,6500K, Pride plusinverter batten,decorative type light fitting white lighting, with square profile and polycarbonate channel,lithium lon battery with charging time 8 hours to 10hours and back up time upto 4 hours high quality materials and design,extruded aluminium housing enhances safety,high quality PC diffuser, easy to install, efficency 125 lm/wand including providingpre-wired, and PVC/Wooden round or square blocks -02 Nosand connected with LED fitting to ceiling roseand removing old unserviceable fitting complete all as specified and directed. |
| 74 | Supply and fixing 20 watts LEDAustra mirror smart light fitting one feet long,contemporary design of mirror light complete decorative LED lighting with extruded polycarbonate, environmentalfriendly, energy efficient, easy to install,PC diffuser, high quality materials,pre-wired including providing PVC round/PVC square blocks-02 Nos and connected with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified and directed. |
| 75 | Supply and fixing 15 wattLED panel type slim, compact,aliminium die cast edge lit panel recess mounted square/round type light fitting with LED opal diffuser (lamp/strip) and separate electronic LED driver and connected with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified. |
| 76 | Supply &fixing , in repairs LEDbldg secruity light fitting of capacity 60 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65/66 protectionand including removing of old unserviceable item complete all as specified and directed. |
| 77 | S & F Energy efficient and energy saving new generation 10 watts LED bulk head light fitting IP-65 luminaire with opel diffuser pre-wired ofluminaires including LED light driver and connected with LED fitting to ceiling rose terminaland incl removing old unserviceable fitting complete all as specified and directed. |
| 78 | Supply &fixing , in repairs SS housing model type wall bracket light 9 watt and incl LED lamp(White/Warm)decorative type,in durable plastic body & designe incl connect with LED fitting to ceiling roseand incl removing old unserviceable fitting complete all as specified and directed |
| 79 | Supply &fixing , in repairs LEDtrack light fitting of capacity 20 Watt LED with incl providing fixing arrangementssuitable roof/ceiling etc. in aluminium PDC AL housing,clear diffuser IP-20 protectionand including removing of old unserviceable item complete all as specified and directed. |
| 80 | Supply &fixing , in repairs LEDspike light fitting of capacity 12 Watt LED with incl providing fixing arrangements with die cast aluminium PDC AL housing,clear diffuser IP-66 protectionand including removing of old unserviceable item complete all as specified and directed. |
| 81 | Supply &fixing , in repairs LEDbush light fitting of capacity 12 Watt LED with incl providing fixing arrangements with die cast aluminium PDC AL housing,clear diffuser IP-66 protectionand including removing of old unserviceable item complete all as specified and directed. |
| 82 | Taking down old unsv light fitting from existing location and Supply and fixed aesthetically designed LED flat panel for surface mounting which provides soft-light and glare free symmetrically illumination 2\"x2\" LED 40/42 Watt(600x600x70mm) light fitting and including providing internally prewired,LED driver,connector and also can besuspended with provided kit,nut,bolts and washers as per site requirement and including connecting up with ceiling rose to fittingcomplete all as specified and directed. |
| 83 | Supply & fixingand sheet metal enclosurewithdouble door ,415 volts AC,VTPNDB, 4 way,8+12 modules, flush mounting with 200amps copper busbar, 2 neutral/earth bars links and MCCB incomer,and MCB SPN/SP/TPNas outgoing and complete forIP43&54 DBs protection and includingremoving old unserviceable DBs and incl making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed. |
| 84 | Supply & fix and in repair sheet metal enclosure acrylic door 240 volts AC,SPNdistribution board 12 wayfor flush mounting with 100amps copper busbar,neutral bar,earth bar suitable for MCB incomer of rating upto 100Amps ,MCB SPN/DP,and MCB SP as outgoing and complete connecting cable linkswith top and bottom removable gland plates withIP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coatall as specified and as directed. .Note for MCB DB and MCBs both are used same make only |
| 85 | Supply & fixing andsheet metal enclosure, with acrylic door type, double door, 240 volts AC,SPN,DB, 8 way, flush mounting with 100amps copper busbar,neutral bar,earth bar links and MCB incomer MCB SPN/DP and MCB SP as outgoingforIP 43& IP54 DBs protection nd includingremoving old unserviceable DBs and making good the disturbed surfaces to match with existing surface and colour shade acomplete all as specified and as directed..Note for MCB DB and MCBs both are used same make only |
| 86 | Supply & fixMCB SP 6 to 32 Amps 10 KA,\"C\" series,AC,240Volts,50Hz , ISI marked and including removing old unsv items complete all as specified and directed. |
| 87 | Supply & fix and MCB SPN 40 to63 Amps 10 KA,\"C\" series,AC,240Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed. |
| 88 | M & L for sub main wiring complete with 4 run of 10 sqmm single core copper conductor (ISI marked)cable1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi strandedcolour coded cables drawn through and including rigid PVC conduit concealed ISI marked medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv submain wiring making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Four run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 89 | M & L for sub main wiring complete with 2 run of 10 sqmm single core copper conductor (ISI marked)cable1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi strandedcolour coded cables drawn through and including rigid PVC conduit ISI marked medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv sub main wiring andmaking good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 90 | M & L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi strandedcolour coded cables drawn through and including rigid PVC conduit concealed ISI marked medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv sub main wiring andmaking good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 91 | M & L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked)cable1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi strandedcolour coded cables drawn through and including rigid PVC conduit concealed ISI marked medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 4.0 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv submain wiring and making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 4 sqmm single core copper conductor cable and one run of 4.0 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 92 | M & L for sub main wiring complete with 2 run of 1.5 sqmm single core copper conductor (ISI marked)cable1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi strandedcolour coded cables drawn through and including rigid PVC conduit 25 mm dia ISI marked medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 1.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv submain wiring and making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 1.5 sqmm single core copper conductor cable and one run of 1.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 93 | Supply and fixsuitable for flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 20Amps, 10KA \"C \"series, 230 Volts,50Hzsuitable for AC\"s/Geysers complete all as specified and directed. |
| 94 | Supply and fixMCCB,100 Amps,4 pole,415 Volts , 16/18KA thermal magnetic type with necessary lugs,thimbles, nuts bolts and washersand including removing old unserviceable itemcomplete all as specified and as directed. |
| 95 | Taking down old unsv ceiling fan from existing location and supply and fixnew ceiling fan with blades, down rods, and connected accessories, 230 V, 1200 mm sweep, with squirrel cage induction motor, anti dust painted, dust free,high speed. Star ratedcomplete all as specified and directed. |
| 96 | Taking down old unserviceable exhaust fans of any type/sweep from work site and deposit to MES store yard Supply and fix new exhaust fan, steel /PVC body AC single phase.230Volts of size 300 mm sweep with bladesand including providing insect protection net frame , with louvers and frameincl writing MES No on exhaust fan with synthetic enamel paint complete all as specified and directedcomplete all as specified and directed. |
| 97 | Taking down old unserviceable exhaust fans of any type/sweep from work site and deposit to MES store yard for safe custody and Supply anf fixingexhaust fan made of sturd engineering plastic /metal body complete with louvers shutters, voltage 230v,50hz,rpm 1200 copper winding of sweep 200 to 300 mm and including providing insect protection PVC net frame , with louvers with frame incl writing MES No on exhaust fan with synthetic enamel paint complete all as specified and directedcomplete all as specified and directed. |
| 98 | Taking down old unserviceable exhaust fans of any type/sweep from work site and deposit to MES store yard for safe custody andSupply anf fixingexhaust fan made of sturd engineering plasticPVC body complete with louvers shutters, voltage 230v,50hz,rpm 1200 copper winding of sweep200 mm and including providing insect protection PVC net frame , with louvers with frame incl writing MES No on exhaust fan with synthetic enamel paint complete all as specified and directedcomplete all as specified and directed. |
| 99 | Supply and fix wall mouted fan 230Volts, single phase, oscillating type, 450 mm sweep, Hi-speed,low noise, heavy dutywith blades and outer cover and including providing hanging hook and connected items complete all as specified and directed. |
| 100 | Cutting the existing surface wall of brick/stone masonary and making round hole at any height suitable for fixing 200 to 450 mm sweep exhaust fan including providingnut,bolt and washers after grouting in PCC and including 3 mm dia 5 cm apreature size GI jali and properaluminium frameto avoid insect protection fix at inner surface of wall andmaking good the disturbed surface area complete all as specified and directed. |
| 101 | Taking down old unserviceable geyses of any capacity from work site at any height and deposit to MES store yard for safe custodyand Supply and fix new electric water heater, storage type steel body/plastic body with copper inner tank and heating element upto2 KW capacity 25 litres, BEE 5 star rated complete with all accessories such as safety valve,thermostat, NRV, Hot waterand Cold waterheavy duty connection pipes-02 Nos,holefasterns-04 Nosand necessary accessories as per site requirement etc.complete all as specified and directed. |
| 102 | Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipeof 15 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC/(PVC hevy duty cover) cover 1:2:4 type B1 of size 45X45X6CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required valueincluding removing old item completeall as specified and directed. |
| 103 | Supply and fix GI bracket pipe of size 32 mm dia medium grade of 1.2 mtr long bent to shape suitable degree of bending as per site requirementwith hot or coldbending method of process for making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixedonwall surfaces and including providingsuitable fabricate galvanised flat ironclamps of 30X6 mm thick-02 Nossuitable for fixing at any place/height with hole fastners,nuts,bolts & washers including grouting on wall etc and including removing of old unserviceable item complete all as specified and directed. |
| 104 | Taking down carefully existing Air Condition unit indoor and out door units of any type/capacity from work site and deposit to MES store yard/ Charge holder without damage for safe custody and refixing after completion Civil and Electrical work and including providing outdoor unit MS stand,nuts,bolts and washers etc complete all necessary accessories forsatisfactorily functioning Complete all as specified and directed. |
| 105 | S&F for PVC non-metalic rigid conduit incl boxes,junctions boxes 1 to 4 way & terminals but incl of all tees,bends,elbows,reducers,bell mouth tube ends and fixing accessories such as couplers lock nuts,saddles,pipes hookes etc ISI marked heavy duty of size 25-32 mm (as required at site)dia for LAN,telephone and TV connections including cutting,chasses and making good disturbed surfaces to match with existing surfaces with plaster/putty and including removing of old unserviceable item complete all as specified and directed. |
| 106 | Supply and fixing TVsockets one module with top cover plate and inner frameincluding all necessary accessories and including removing of old unserviceable item complete all as specified and directed. |
| 107 | Supply and fixing Telephone socket(RJ11) one module with top cover plate and inner frameincluding all necessary accessories and including removing of old unserviceable item complete all as specified and directed. |
| 108 | Supply and fixing LAN/USB socket(RJ42) one module with top cover plate and inner frameincluding all necessary accessories and including removing of old unserviceable item complete all as specified and directed. |
| 109 | Supplying and laying of CPVC /UPVC pipes SDR 11 & Plain SDR 11 incl allfittings of outer dia 25 mmon walls with clampingfor AC\"s drain pipe complete all as specified and directed. |
| 110 | Taking out old unsv existing on load change over any type/rating and incl providing supply and fix on load change over switch 415V in sheet metal enclosure/open excution type/side handle as per site requiremet 4 pole of capacity 250 amps and including providing incoming and outgoing cables features and necessary hole fasters, lugs,nuts,bolts and washers etc and including providing necessary alterations,welding works in existingpanels/on wall mounting fitting complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail