| Sl. No. | Item Description |
| 1 | Taking down Chowkats or frames, area of opening n\"exc 1.5 Sqm each (without taking off shutters from the frame) complete all as specified and directed. |
| 2 | Taking down Chowkats or frames, area of opening exc 1.5 Sqm but n\"exc 4.00 Sqm each (without taking off shutters from the frame) complete all as specified and directed. |
| 3 | S&F factory made single extruded WPC (Wood Polymer Composite) solid Frames/ Chowkhatfor door/ window/ Ceosetory windows etc of size 45 x 70 mm, fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed.NOTE :(i) The WPC shall comprising of virgin PVC polymer of K value 58-60 Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms). (ii) The frame shall fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws.(iii) The WPC shall have minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant.(iv) The cost of M.S. hold fast/ lugs or SS dash fasteners shall deemed included in quoted unit rate. Each frame shall be fixed with min 06x holdfasts/ faster\"s. |
| 4 | S&F30 mm Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screwwithdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus ofelasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size withnecessary full body threaded star headed counter sunkS.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S Sscrews shall be paid separately) |
| 5 | M&L for Powder Coated aluminium frame for doors, windows, ventilators (thickness of powder coating not less than 50 micron) with one or more rebates including jointing cleat for fixing etc complete all as specified and directed. |
| 6 | M&L for Powder coated aluminium (minimum thickness of powdercoating 50 micron) for shutters of doors, windows & ventilatorsincluding providing and fixing hinges/ pivots and making provision for fixing of fittings wherever including the cost of EPDM rubber/neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gapsat junctions, i.e. at top, bottom and sides with required EPDMrubber/ neoprene gasket etc. Aluminium sections shall besmooth, rust free, straight, mitred and jointed mechanicallywherever required including cleat angle, aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.Note:-1. The rate is inclusive of cost of builders hardware such as hinges, bow handles, locking arrangements rubber beading for fixing of glass etc complete all as directed by Engr-in-Charge.2. Glass and wiremesh shall be measured and paid separetely |
| 7 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 8 | M&L for rendering 15 mm thick on other than fair faces of walls of brick work or concrete surfaces in cement mortar 1:6 mixed with water proofing compound as per manufacture\"s instruction or as directed by Engg-in-charge finishing the surface even and smooth without using extra cement complete all as specified and directed.Note:(i) WPC shall be measured and paid seperatly as supply only under respective item on production of Purchage Vouchers. Non production of PVs may cause to disallow the paiyment claimed on account.(ii) The unit rates quoted shall be applicable for exicution of work up to 10m height and deemed included cost ofallT&P ,scafolding and all safety precaution (i.e. Safety Jacket, Safety Shoes, Safety Masks, Safety Helmet, Safety harness, Safety Goggles etc) required for smooth exicution of work. Without safety precaution this work will not be allow to commence. |
| 9 | M&L for rendering 10mm thick in CM (16) on Brick/conc surface finished even and fair on internal surfaces of wall, complete all as specified and directed. |
| 10 | Supply only liquid integral crystalline water proofing compound complete all as specified and directed. |
| 11 | M&L forpreparation of old treated surface of wall by scrapping with wire brush/sanding paper/ metal patti, removing nails etc, and make surface clean, free from dust, loose paint etc,filling drpessions, with wall care putty, to receive decorative coat/painting coat complete all as specified and directed |
| 12 | M&L for applying two coats of oil bound distemper on prepared wall surfacecomplete all as specified and directed. |
| 13 | M&L for applying two coats of exterior emulsion paint on prepared wall surfacecomplete all as specified and directed. |
| 14 | M&L for theme painting/artistic work on walls comprising hand-painted murals/geometric/abstract motifs using high-fastness acrylic/artist colours, including surface preparation with wall care putty in two coats (overall 1–2 mm) to achieve smooth finish, primer coat, application of emulsion paint in two coats as base shade, layout, grid marking, stencils (if any), blending, shading and colour transitions, and applying protective clear coat (matte) over artwork, complete all as specified and directed. |
| 15 | Taking down sanitory fittings including asseccories any discription, type and pattern (WC/EWC/ WHB/ flushing cistern etc ) complete all as specified and directed. |
| 16 | S&Fvitreous china wash hand basin with pedestal pattern, white, flat back, size 550 x 400 mm, excluding taps, waste chain and plug, but including bracket, 32 mm waste coupling, and flexible PVC waste pipe, complete all as specified and directed.Make: Cat pat No. CNS-WHT-801 of Jaquar or eqiuvalent ofgrohe or Kohlar |
| 17 | S&F Vitreous China pedestal pattern (P-trap), white, with integral foot rests including setting the trap and pan in concrete, complete all as specified and directed.Make: Cat pat No. CNS-WHT-551SSPP of Jaquar or eqiuvalent ofgrohe or Kohlar |
| 18 | S&F 10 ltrs PVC (White) valve less syphonic action type, Slim Wall Hung flushing cistern, low level with installation kit, drainage pipe, inlet ball valve float, handle, aluminium brackets for bottom support completefixing with gitties embeded in wall etc complete all as specified and directed. WHC-Make: Cat pat No. WHC-WHT-184T of Jaquar or eqiuvalent ofgrohe or Kohlar |
| 19 | Dismantling water tanks exc 250 ltr but n\"exc 500 Ltrs capicity, any type and discription including removing from site complete all as specified and directed. |
| 20 | S&F 500 liters capacity white colour triple layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and directed. |
| 21 | S&F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 22 | S&F in repair PTMT two-way bib tap, 15 mm nominal bore, heavy-duty PTMT body and handle (no metal components), quarter-turn operation on both outlets, integral wall flange (PTMT), screwed for 15 mm pipe/adaptor, complete with PTFE tape, fixing accessories, leak testing and commissioning, complete all as specified and directed. |
| 23 | S&F in repair PTMT health faucet (hand spray) with PTMT trigger, PTMT body, 1.0–1.2 m flexible hose in PTMT/polymer construction, and PTMT wall holder/bracket; connection to 15 mm PTMT two-way bib tap/angle outlet, including PTFE tape, fixing, testing and commissioning, complete all as specified and directed. |
| 24 | S&Fin repair PTMT pillar tap for wash hand basin, 15 mm nominal bore, single/quarter-turn operation, PTMT body and handle with integrated PTMT aerator, supplied with PTMT fixing hardware and PTMT back-nut, including connection to supply line with PTFE tape, testing and commissioning, complete all as specified and directed |
| 25 | S&F in repar PTMT stop valve, 15 mm nominal bore, quarter-turn operation, PTMT body and handle with PTMT wall flange/rosette, screwed inlet and outlet for 15 mm pipe/adaptor, including PTFE tape, necessary fixing accessories, connection to fixture (WHB/ health faucet/ flush tank), leak testing and commissioning, complete all as specified and directed. |
| 26 | Taking up or down steel tubing and connection including cleaning for refixing or removal to store 15mm bore pipe complete all as specified & directed. |
| 27 | S&F CPVC pipes 15 mm dia (SDR-11, hot and cold water application) with CPVC brass-threaded fittings where required, including all fittings (elbows, tees, couplers, unions), solvent cement joints, clamps and supports at specified spacing, cutting/chasing walls and making good to surfaces, fixing concealed/exposed as directed, testing to working pressure, complete all as specified and directed. |
| 28 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), remaving serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 29 | M&L for Non - skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but n\"exc 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchover and including 10mm thick cement mortar screed bed or bedding layer (1:4) for laying floor finishes complete all as specified and directed. |
| 30 | M&L for Glazed ceramic tiles in vertical surface 350 x 250 x 7 mm/ 450 X 350 X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to matchover and including10mm thick plaster in cm 1:4 complete all as specified and directed. |
| 31 | S&F in repair UPVC (SWR) 110 mm dia pipes TYPE -B Conforming to IS 13592 single socketed, in any length with rubber ring joints, laid in trenches or in floorscomplete all as specified and directed. |
| 32 | S&F 110 mm dia UPVC(SWR) plain bends any radius complete all as specifiedand directed. |
| 33 | S&F 110 mm dia UPVC (SWR) branch piece, (double Y) equal or unequal complete all as specified and directed. |
| 34 | S&F 75 mm dia UPVC floor trap plain with grating including jointing with solvent cement complete all as specified and directed. |
| 35 | M&L for Mild steel work in brackets, clamps, flat iron supports, holdfasts etc., fabricated from MS flat/round/angle sections, including cutting, bending, drilling, welding, and fixing in position to hold rainwater pipes against wall, with necessary bolts, nuts, washers, and painting two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 36 | S&F PTMT gate valve, 15 mm nominal bore, full-bore, rising/non-rising stem type in PTMT construction with PTMT handwheel/operating knob, female threaded ends suitable for 15 mm piping/adaptors, including PTFE tape, unions/couplers as required, installation, leak testing to working pressure and commissioning, complete all as specified and directed. |
| 37 | S&Fstainless steel wire mesh, 0.56mm nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks, or stainless steel wire staples complete all as specified and directed. |
| 38 | S&F 5.5 mm thick plain sheet glass as in,shutters with and including rubber gasket and natural colour anodized aluminium snap beading/glazing, clips etc complete all as specified and directed. |
| 39 | S&F 150mm long SS handles with required full body threaded star headed counter sunkS.S screws, complete all as specified and directed. |
| 40 | S&F 200mm long SS barrel tower bolts with required full body threaded star headed counter sunkS.S screws complete all as specified and directed. |
| 41 | S&F 250 mm long SS sliding door bolt with hasp, staple (bolt type) and fixing clips with required full body threaded star headed counter sunkS.S screws complete all as specified and directed. |
| 42 | S&F 100 mm long SS butt hinges with required full body threaded star headed counter sunkS.S screws, complete all as specified and directed |
| 43 | S&F 300 mm long, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed |
| 44 | S&F 140mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, complete all as specified and directed |
| 45 | Dismantling of sheets in roof coveringsany discription type (corrugated, semicorrugated, etc.) complete all as specified and directed |
| 46 | M&L for prepainted colouredgalvaniume aluminium zinc coatingGI basedcorrugated steel sheet 0.50 mm thickof ancolourhaving tensilestregnth of 550 mpaas in roofcovering andcladdingto wall fixed with self tapping screwscomplete all as specified and directed. |
| 47 | M&L for prepainted colouredgalvaniume aluminium zinc coatingGI basedplain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roofcovering /cladding to roof wall, fixed with self tapping screws complete all as specified and directed. |
| 48 | Dismantling wrought iron or mild steel work of any description not otherwise provided forcomplete all as specified and directed. |
| 49 | M&L for structural steel work using rolled mild steel of grade Fe 410-W(Gde-E- 250)quality-A as in roof trusses (framed and trussed), purlins, crane gantries, rails and fastenings, heavy bracket framing (made from beam, tee, angle, channel or flat sections), including distance pieces, cleats, gusset plates etc., cut to required lengths, hoisted, fixed in position, including welding, bolting or riveting as required complete all as specified and directed. |
| 50 | S&F mild steel screw bolts diameter of neck in 16 to 20mm (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5cm but not exceeding 10 cm long complete all as specified and directed. |
| 51 | M&L for Cutting chases, pinning in brick wallsnot exc 10 cm girth, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc.complete all as specified. |
| 52 | Removing all vegetation, foliage and debris from E/M installation premises (Pump houses/ STP/ power hoses etc)including its disposal within cantonment limits where directed complete all as specified and as directed.Note : (i) Engineer -in charge shall ordered in writing for each installation seperatly as and when required. (ii) Date of order and installation name shall be recorded in MB for payment .(iii)The job so ordered shall be completed by the contractor within 07 days from the date of order.If the job is not complited within specified time, a penalty @ Rs 500/- per day shall be recoveredfrom the contrctor\"s payment. (iv) Thecost of any T&P sefty inruments required for exicuition and complition job setisfectory shall deemed included in quoted unit rates. |
| 53 | Pruning of tree branches any diameter and up to any height (full height of tree) so as to clear the LT/HT elctric lines/ two pole/ four pole structure (not less than one meter from the electric line-both side ore one meter all round the two pole/four pole structure) to the entire setisfaction of Engineer Charge including it\"s disposal within cantonment limit where directed complete all as specified and as directed.Note : (i) The work between two conjucative poleor each 2 pole/ 4 pole structureshall be treated as one job and shall be measured and recorded in MB acordingly for payment perpose.(ii) Thecost of any T&P and sefty inruments required for exicuition and complition job setisfectory shall deemed included in quoted unit rates. |
| 54 | S&F in repair gun metal gate/ globe valve with iron wheel head, screwed both ends for 15mm dia pipe and fixed complete all as specified and directed. |
| 55 | All as per item No. 54 above but gun metal gate/ globe valve for 20mm dia pipe |
| 56 | All as per item No. 54 above but gun metal gate/ globe valve for 25mm dia pipe |
| 57 | All as per item No. 54 above but gun metal gate/ globe valve for 40mm dia pipe |
| 58 | All as per item No. 54 above but gun metal gate/ globe valve for 50mm dia pipe |
| 59 | S&F in repair 80mm dia/ bore CI sluice valve of pressure rating PN 1.6 with stainless steel rod/spindle and check nutand fixed complete all as specified and directed- |
| 60 | All as per item No. 59 above but sluice valve of 100mm dia/bore. |
| 61 | All as per item No. 59 above but sluice valve of 150mm dia/bore. |
| 62 | S&F in repair CI non return valve (NRV) 150mmdia/bore of pressure rating PN 1.6 with stainless steel rod/spindle and check nut complete all as specified and as directed. |
| 63 | M&L forrepair ofsluice valve of any by means of required leathing work, re-threding work to the sluce valve rod including replacement of defective checknut, packing etc so as to smooth work ofthe sluice valve with enire setisfectionof Engineer in chargecomplete all as specified and directed.Note : The cost oftaking out the sluice valve rod, any transportation involved for to and fro movment up to workshop and refixing the same in existing poisition after repair shall deemed included in quoted unit rates. |
| 64 | M&L for CI/DI fittings for pipes, any discription, size and type complete all as specified and as directed. |
| 65 | S&F mechanical joint (D-joint) in repair/ replacement of broken 80mm dia/ bore CI/DI pipe line complete with rubber ring, nut/bolts and washer with sleeve length complete all as specified and as directed. |
| 66 | All as per item No. 65 above but D-joint for 100mm dia/ bore CI/DI pipe line |
| 67 | All as per item No. 65 above but D-joint for 150mm dia/ bore CI/DI pipe line |
| 68 | Testing of water samples from any govt approved testing agency/ CGWB/ UP Pollution Control Board and submitting results to the Engineer -in charge complete all as specified and directed.Note :(i)Thesamples shall be tested for the following parameters:-(a) Turbidity, (b) Ph value, (c) Total hardness,(d) Iron,(e) Chloride, (g) Fluoride, (h) Dissolved Solids,(j) Calcium,(k) Mercury,(l) Arsenic, (m) Lead, (n) Pesticides, (o) Alkalinity,(p) Nitrate, (q) Total collifarm,(r) e- Collifarm.(ii) Contractor will arragne to collect the water sample from pump houses/ Sewage treatment plant /swimming pool and at end point(s) of water supply lines situated in any location within MOD land as and when direccted by Engineer in charge in writing. (iii) The cost of container/ bottol, transportation involed up to testing lab ( to end fro) and testing charges shall be boarn by contractor and quoted unit rates shall deemed included such expences. |
| 69 | Periodical inspection ofchemical dosing pump system of any discription, capiciity, type installed in MES installations within AOR of GE East Pryagraj, includingcleaning of calcium deposits in dosing pump, NRV (both suction & discharge), tank and PVC pipes, repair of any leakage and replacement of minor parts such as PVC pipes, suction & discharge NRV and any other nut, bolt washers, gakits etc as required for it\"s smooth and fully functional and operational up to the entire setisfection of engineer-in-charge, completeall as specified and directed.Note : (i) The periodicity will be decided and directed by Engineer-in-charge. (ii) The cost of material and labour, transportation and T&P as reqired shall be boarn by the contractor and quoted unit rates shall deemed included such expences. |
| 70 | S&Fin repair/ replacement fully automatic online pressure feed chemical dosing pump, single phase, 230 Volts, 50 Hz, fully adjustable, output capacity upto 10 LPH with bleed valve assembly, NRV, Stainer, FRP tank, connection pipe etc with chlorine analyzer/flow meter, includingtesting completeall as specified and directed. |
| 71 | S&F in repair digital water level indicator with display/indicator switch/float switch/ sensor to the overhead (OH) water storage tank including connections withPVC insulated weather proof 1.0 Sqmm 4 core annealed copper cabe (from OHR to Pump house) inclusding testingcompleteall as specified and directed.Note:-(i) Necessary scaffolding/ladder/safety equipmnet required to climb over the OH tank, T&P shall be provided by the contractor. The cost of the same shalldeemed included in and quoted unit rates.(ii) All safety precausion shall be strictly adheredand damages if any shall be born by contractorduring execution.Contractor will ensured that laboures appointed will be life ensured. Unit quoted rate shall be deemed including for above aspects and no claim on this account shall be entertained by the deptt.(ii) Cost of cable also deemed included in quoted unit rates. |
| 72 | Development of borewell ( any dia, capicity depth and in any location within AOR of GE East Pryagraj) by flushing and cleaning of borewell usingLow pressureair compressor having pressure 200 PSI to 400 PSI to removeraw water, sand, silt, dust or wastes and decayed particles to improve the yield of the borewell complete all as specified and as directed.Note : The air compressor shall be arranged by the contractor and cost of thw same shall be deemed included in quoted unit rates. |
| 73 | Supply and filling of gravels of 10-12.5mm rounded, siliceous, free from foreign matters, washed and disinfected, conform to IS-4097:1988complete all as specified and as directed. |
| 74 | M&L for stoping/ repairing any leakage from 100mm bore water supply pipe line, by repiring of leakage ring tyton joint (rubber gasket joint) for spigot and socket CI/DI pipes or Joint with rubber or fibre board gasket for flanged pipes including neceaasry earth work (excavation, returning filling and removing) complete all as specified and directed.Note :- Material, labour & T&P required for compltion of the job shall deemed included in the quoted unit rates |
| 75 | All as per item No. 74 above but ring tyton joint 100mm dia/ bore CI/DI pipe line |
| 76 | M&L for stoping/ reapiring any leakage from 80 to 200mm bore water supply pipe line, by repiring of leakage of run lead joint with lead wool and spum yarn for spigot and socket CI/DI pipes including neceaasry earth work (excavation, returning filling and removing) complete all as specified and directed.Note :- Material, labour & T&P required for compltion of the job shall deemed included in the quoted unit rates. |
| 77 | Replacement ofold U/S MS clamp with new clamp of same size, typeincluding nuts, bolts and rubber packing suitable for 50 to 150mm bore CI/DI/GI pipe (main line) complete including neceaasry earth work (excavation, returning filling and removing) complete all as specified and directed.Note :- (i) Labour & T&P required for compltion of the job shall deemed included in the quoted unit rates.(ii) Clamp with nut, bolt and washers shall be measured and paid seperatly however the cost of rubber packing is deemed included in quoted unit rates. |
| 78 | M&L for Mild steel work in brackets, clamps, flat iron supports, holdfasts etc., fabricated from MS flat/round/angle sections, including cutting, bending, drilling, welding, and fixing in position to hold rainwater pipes/ water supply pipe line with necessary nut, bolt and washers complete all as specified and directed. |
| 79 | M&L for stoping/repair any leakage from GI/PPR water supply pipe line ofany size and discroption (up to 80mm dia) and in any position complete all as specified and directed.Note :- Material (includingfittings, making threde, if required) , labour & T&P required for compltion of the job shall deemed included in the quoted unit rates. |
| 80 | Dismantling ofbrick work, cement concrete in valve pit chember of any size, type and discription complete all as specified and directed |
| 81 | Dismantling ofwrought/ mild steel work as in valve pit chember cover with frame any disctiption complete all as specified and directed |
| 82 | M&L for Brickwork with sub class ‘B’ old size bricks, straightor curved on plan, radiusexc 6mmeanradius built in CM 1:4 complete all as specified & directed. |
| 83 | M&L for PCC 1:4:8, type B-2 (using 40mm graded stone agregate) as in foudation, mass filling complete all as specified & directed. |
| 84 | M&L 15 mm thick rendering in cement mortar 1:4 on internal surface of valve pit, making surface fair and evencomplete all as specified & directed. |
| 85 | M&L for PCC 1:2:4, type B-0 (using 12.5mm graded stone agregate) as in coping over brick wall/ bed block for embedding chember cover complete all as specified & directed. |
| 86 | M&L for mild steel framed work as in doors orgates of angle or other sectionwith gusset plates, rails,braces, etc., complete, drilled forfixing of steel sheeting orothercovering. Doors, etc. to beprepared for hanging or slidingwith and including either hooksand hinges or steel hangingdoor fittingsand hanging; also fastening, making locking arrangment andfixing including two coat of synthetic enamal pain over a coat of red oxide primercomplete all as specified & directed.Note : Steel sheeting or other covering,running rails and guides, hinges, sliding bolt, haps staple etc shall also be paid under this item. |
| 87 | S&F in repairbest quality gland packing of appropriate dia,suitable for sluice valve/ Non return valve/ gate valve os any discription, type and capicty and in any location under AOR of GE (East) Prayagraj so as to stop any leakagecomplete all as specified & directed. |
| 88 | S&F in repair MS nut bolts/washers/ foundation bolts made out of hard carbon steel , any dia & length (off size) complete all as specified and as directed. |
| 89 | Taking outsubmersible pump & motorfrom borewellconnected to the colomn pipe, any discription, type, capicity and at any depth with the help oftripot stand, chain pully and MS clamp, disconnected pump/motor from colomn pipe, all electric connection,supporting rop etc, transporting to workshop for detecting fault, dismantling of pump/motor, replacement of defecive part, reassembling after repair/rewinding,, testing pump/motor for it\"s smooth working, transporting back to the site, making all connections (elctric, colonm pipe and supporting rope) and re-lowering in it;s orignal position and testing complete all as specified and directed. Note : (i) contractor shallmaking all arrangement of tripot stand, chain pully, clamp forMS column pipe. The cost of the same shall deemed included in quotedunit rates(ii) Any part/material like, rewinding, \"O\" ring, Top bearing, Impeller etc required to replace .shall be measured and paid seperatly under respective item here-under.(iii) Any other material like nut, bolt washers, rubber gasket, oil, grease etc, if required shall be provided by the contractor and cost of the same shall deemed included in quoted unit rates.(iv) leangth of colomn pipe shall be measured for payment. |
| 90 | S&Fvalve cashing \"O\" ring suitable for submersible pump& motor of any discription, type and capicty complete all asspecified and directed. |
| 91 | S&F \"Valve guidesuitable for submersible pump & motor of any discription, type and capicty complete all asspecified and directed. |
| 92 | S&F neck ring suitable for submersible pump & motor of any discription, type and capicty complete all asspecified and directed. |
| 93 | M&L for rewindingof burnt submersible motor of cap 40 HP, 3 phase, 415 Volts with PVC insulated copper conductor \"\"F\" class insulation of existing gauge including cleaning the each slot, providing the insulating material and replacement of bush/bearing if required/ ordered by Engineer-in-charge complete all asspecified and directed. |
| 94 | S&F in repair thermal overload relay 415V range 28 to 42 Amp complete all as specified and as directed. |
| 95 | S&F in repair3 Pole Power Contactor ML-3 having AC3 Rating 80 Amps with 2 NO + 2 NC Auxilliary Contacts complete all as specified and as directed. |
| 96 | S&F in repair3 Pole Power Contactor ML-3 having AC3 Rating 60 Amps with 2 NO + 2 NC Auxilliary Contacts complete all as specified and as directed. |
| 97 | S&F in repair MCCB, 4P, 160 Amps 36 KA, 415V with Thermal Magnetic Release, Spreader Links, Adjustable Over Load andShort Circuit setting complete all as specified and as directed. |
| 98 | S&F in repairMCCB, 3P, 160 Amps 36 KA, 415V with Thermal Magnetic Release, Spreader Links, Adjustable Over Load andShort Circuit setting complete all as specified and as directed. |
| 99 | M&L for earthing complete with steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep belownormal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the 25x5mm galvanized flat iron earth stripby means of bolts, nuts, check nuts and washers of galvanized iron, steel earthwire protected by provision of GI medium grade pipe 15mm bore including provision of concrete pit made from PCC (1:2:4) type B-1(using 20mm graded stone aggregates) with 17mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 02 No and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom, 1.75 metre long placed on top edge of earth plate, common salt & charcoal filling, test point made out of 17mm x 8mm FI with fixing arrangement, funnel, wire mesh and earth work in loose/ softsoil, ( excavation, returning filling in and removal of surplus soil to a distance not exceeding 50 metres), all as per electrical plate No.5 of SSR Part-I connected to earth test point all as specified or indicated including testing on complete all as specified and directed. |
| 100 | M&L forXLPE insulated, armoured heavy duty electric cable with aluminiumconductor, 1100 Volt grade, ISI marked as per IS-7098, cross-sectional area 25 sq.mm 3.5 core, laid in trenches / on poles / walls including connecting and testing, complete all as specified and directed.NOTE:- Excavation and earthwork, sand cushioning and brick cable protection shall be measured and paid separately under respective items of this Schedule. |
| 101 | S&F cable jointing kit,straight through cold shrink type, suitable for25 sq.mm 3.5 core XLPE armoured aluminium conductor cable, 1100V grade cablewith jointing material and accessories including testing, complete all as specified and directed. |
| 102 | M&L for 10 Sqmm multistand copper condutor, sigle core cable for interconnection / internal wiring of panels complete all as specified and directed. |
| 103 | M&L forsand cushioning with natural, clean and dry river sandfor cable protection in trenches (8 cm before laying the cable and 15 cm after laying ) and consolidated complete all as specified and directed.NOTE:- Punned thickness of 18 cm shall only be measured and paid. |
| 104 | M&L forwell burnt bricks class \"B\", old size, designation 75 in trenches ascable protection, laid width equal to length of brick , complete all as specified and directed. |
| 105 | M&L for 50mm bore steel tubing, light grade, ISI marked, galvanised , laid in trenches orfixed to walls / ceilings or laid in floors /in ducts /under road crossing for passing cables, complete, in repair/replacement complete all as specified and directed.NOTE:- Earth work if required for taking out/down old and unserviceable GI pipe will be measured and paid separately under respective items here under. |
| 106 | Cutting the existing road/hard standing surfaces 50cm in width and depth up to 90cm and and getting out for laying /passing cable through pipe including required eartwork (excavation, returning filling in, including watering and well ramming in layers not exceeding 25cm and making good making good the disturbed surface so as to match the existing complete all as specified and directed. |
| 107 | Supply and mixing water disinfectant (TCCA-90) containing 90% chlorine contents (Calcuim based granular disinfectant for water treatment,complete all as specified and as directed.Note :(i) No material shall be supply to the MES store in bulk through RV.(ii) The contractor\"s skilled employ shall visit all water supply installations daily and mixed the appropriate/required quantity with conseltation of JE/AGE concern so as to maintain the water quality. (iii) The contractor shall maintain a pacca bound register to record the installation/plant wise day to day conjumption of chemical. All procurment of chemicals shall also me recorded in this register showing invoice Number and quantity. (Performa has been given in Tender Document of Sl. Page No. 170.)(iv) Only actual consumed quantity shall be measured and concider for payment irrespective of quqntity procured by the contractor. remaing quanity on complition of work shall be the contractor proprty and contractor have no claim on this account. packed in 50 KG plastic drum) |
| 108 | All as per item No. 107 above but water disinfectant containing 60 to 70% chlorine contents |
| 109 | S&F in repair Chlorine test kit with coloured ample complete with all testing fitments and OT solutioncomplete all as specified and as directed. |
| 110 | Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sq m on plan and not exc 1.5 m in depth and getting out in Soft/Loose Soil complete all as specified and as directed. |
| 111 | Returning, filling in, including spreading, levelling, watering and well ramming in layersnot exc 25 cm. in Soft/Loose Soil, complete all as specified and as directed. |
| 112 | Removing excavated material n exc. 50m and depositing where directed at a level not exc. 1.5 m above the starting point in Soil, complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail