| 1 | Taking down carefully aluminium/ copper point wiring/power point wiring, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. completeand making good the disturbed surface to match adjoining surfaces complete all as specified and as directed. |
| 2 | M & L for Point Wiringwith PVC insulated unsheathed1.5 Sqmm single core 1100 volts grade multi strandedFRLS copper conductor cable conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked with accessories concealed in walls including MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed in walls withlaminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including 1.5Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, .for the following all as specified and as directed :- |
| 3 | One light point controlled by one switch |
| 4 | One fan point controlled by one switch/regulator |
| 5 | One light point controlled by 2 way switch |
| 6 | One 3 pin socket out let 5 Amps on independent board |
| 7 | One bell/buzzer point controlled by bell push |
| 8 | One 3 pin socket out let 5 Amps on same board with other switches |
| 9 | M & L for PointWiring withPVC insulated unsheathed 1.5 Sqmm single core 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and includingnon-metalic rigid PVC conduit medium grade ISI marked with accessories concelaed type wiringincluding GI/ MS brandedsunken boxes of suitable module concealedon walls including modular frame and cover of suitable modulefixed with cadmium plated iron screws for housing modular typeswitches, switch socket outlets, fan regulators etc., including PVC insulated single core multi stranded copper conductor cable1.5 Sqmm as earth continuity conductor and connecting to common earth dolly, for the followingall as specified and as directed :- |
| 10 | One light point controlled by one switch |
| 11 | One fan point controlled by one switch/regulator |
| 12 | One light point controlled by 2 way switch |
| 13 | One 3 pin socket out let 5 Amps on independent board |
| 14 | One bell/buzzer point controlled by bell push |
| 15 | One 3 pin socket out let 5 A on same board |
| 16 | All as per item No 2 herein beforebut concealed wiring drawn through existing PVC conduit for following :- |
| 17 | One light point controlled by one switch |
| 18 | One fan/Exhaust point controlled by one switch/regulator |
| 19 | One light point controlled by 2 way switch |
| 20 | One 3 pin socket out let 5 Amps on independent board |
| 21 | One bell/buzzer point controlled by bell push |
| 22 | One 3 pin socket out let 5 A on same board with other switches |
| 23 | M & L for Point WiringwithPVC insulated unsheathed 2.5 Sqmm single core 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through non-metalic existing PVC conduitrun on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., includingPVC insulated 2.5 Sqmm single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. |
| 24 | M & L for Sub main wiringwith two runs of 4 Sqmm single core PVC insulated FRLS copper multistranded cable 1100 volts gradewith one run of4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductorcable as earth continuity conductor, drawn through existing non metallic rigid PVC conduit and conduit accessories all as specified and as directed. |
| 25 | M & L for surface Point WiringwithPVC insulated unsheathed 1.5 Sqmm single core multi strandedFRLS copper conductor cable 1100 volts gradeconforming to IS 694 drawn through and includingPVC Casing & CapingISI marked with accessories surface type wiringincluding 1.6 mm thick MS sunken boxes concealedin walls includinglaminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., includingPVC insulated single core multi stranded copper conductor cable 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly for the following all as specified and as directed :- |
| 26 | One light point controlled by one switch |
| 27 | One fan point controlled by one switch/regulator |
| 28 | One light point controlled by 2 way switch |
| 29 | One 3 pin socket out let 5 Amps on independent board |
| 30 | One bell/buzzer point controlled by bell push |
| 31 | One 3 pin socket out let 5 A on same board |
| 32 | M & L for Point Wiringwith PVC insulated unsheathed2.5 Sqmm single core multi strandedFRLS copper conductorcable 1100 volts grade conforming to IS 694 drawn through and includingnon-metalic PVC conduit medium density ISI markedwith accessories concealedtype run on walls/ ceiling includingMS terminal boxes fabricated with 1.6 mm thick MS sheetconcealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., includingPVC insulated single core multi stranded copper conductor cable 2.5 Sqmmas earth continuity conductor and connecting to common earth dolly, all as specified and as directed. |
| 33 | M & L for Point WiringwithPVC insulated unsheathed 2.5 Sqmm single core multi strandedFRLS copper conductor cable 1100 volts gradeconforming to IS 694 drawn through and including PVC casing capingISI marked with accessories surface type wiring run on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheetconcealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including2.5Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.Note for Item No 2 to 9:-(i) The earth wire for the points in the same circuit can be looped from point to point(ii) Earth wire shall be taken inside the conduit(iii)Cost of terminal box is deemed to be included in the item rate quoted for point wiring(iv) Cost of a circuit ofany length of cablefrom DB to any switch/ socket board to be included in point wiring. (v) Quoted rate to be included cutting chases for conduits and making good to walls wherever item described. |
| 34 | S&FLED batten with luminaire suitable for indoor applications 20 Watts capacity, 4 feet long with extruded aluminiumhousing & integrated LED channelcomplete with all accessories all as specified and directed. (Make: Bajaj, Cat No.BCLAB20 WH LED P or equivalent Makes specified in P S herein after) |
| 35 | S&FLED batten with luminaire suitable for indoor applications 10 Watts capacity, 2 feet long with polycarbonate housing & integrated LED channel with white arcylic covercomplete with all accessories all as specified and directed. (Make: Bajaj, Cat No.BCLSB 10 WH or equivalent Makes specified in P S herein after) |
| 36 | S&FRecess mountedLED Luminaireof size 2\" x 2\", capacity36 Watts, white powder coated CRCA housing with LEDs seamless front frame with flat white high transmission arcylic cover complete with all accessories as specified and directed.( Make: Bajaj, Cat No : BZRSQL 36W GZi WH or equivalent Makes specified in P S herein after) |
| 37 | S&F Surface mountedLED Luminaire of size 1\" x 1\", capacity24 Watts, white powder coated CRCA housing with LEDs seamless front frame with flatwhite high transmission arcylic cover complete with all accessories all as specified and directed. (Make: Bajaj, Cat No : BZSSQL 24W LED WHI or equivalent Makes specified in P S herein after) |
| 38 | S&FWall mounted Bulkhead LEDluminaire 10 watt capacity, powder coated pressure die-cast aluminium alloy housingwith IP 65 protectionas specified and directed. (Make: Bajaj, Cat No : BIBWP10WLED or equivalent Makes specified in P S herein after) |
| 39 | S&FModular switch 1 way6Amps, 1 moduleall as specified and directed. |
| 40 | S&F Modular switch 1 way 16Amps , 1 moduleall as specified and directed. |
| 41 | S&FModular switch 2 way 6Amps, 1 moduleall as specified and directed. |
| 42 | S&FModular Bell push 6Amps1 moduleall as specified and directed. |
| 43 | S&F Modular Socket, 6Amps- 2/3 pin combined, 2 moduleall as specified and directed. |
| 44 | S&FModular Socket 6Amps /16Amps - 2/3 pin combined 2 module,all as specified and directed. |
| 45 | S&F Modular typefan step regulator, 120W - 2 module all as specified and directed. |
| 46 | S&FSwitch piano type,flush button single pole, two way 5 Amps all as specified and as directed. |
| 47 | S&F Angle holder PVC/polycarbonate type all as specified and as directed |
| 48 | S&F Switch piano type,flush type single pole one way 5 Ampsall as specified and as directed |
| 49 | S&Fswitch socket combination5 pin2 in 1, 5 AmpsFlush typeall as specified and asdirected |
| 50 | S&FSwitch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal all as specified and asdirected |
| 51 | S&F socket outlet 2 in 1, 3 pin 5 Amps all as specified and asdirected |
| 52 | S&FBell push flush type 5Ampsall as specified and asdirected . |
| 53 | S&F in replacementMCB SPN32/40 Amps240 voltsC curvescomplete all as specified and as directed |
| 54 | S&F in replacement MCB single pole10/16/20/32 Amps 240 voltsC curvescomplete all as specified and as directed |
| 55 | S&F in replacement MCB TPN 415 volts, 10KA \"C\" curve 63 Amps complete all as specified and as directed |
| 56 | S&F in replacementMCB TPN 415 volts, 10KA \"C\" curve100 Amps complete all as specified and as directed |
| 57 | S&F in replacement of MCB Distribution boardSPN 4 way, double door type, 240 volts with 200 Amps rated busbaras specified and as directed. |
| 58 | S&F in replacement of MCB Distribution board SPN 8 way, double door type, 240 volts with 200 Amps rated busbaras specified and as directed. |
| 59 | S&F in replacement MCB Distribution board TPN 4 way, double door type,415 volts with 200 Amps rated busbar for housing MCBs as specified and as directed. |
| 60 | S&FCeiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed |
| 61 | S&F Stepped type electronic fan regulator, flush type, Switch/socket type all as specified and as directed |
| 62 | S&F in replacementDing Dong bellAC 230 volts single poleall as specified and as directed |
| 63 | S&F inrepairsub main wiring1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed(Note : Three run of 6sqmm cable and one run of PVC conduit altogether measured as one unit) |
| 64 | S&F in repairsub main wiring1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed(Note : Three run of 4sqmm cable and one run of PVC conduit altogether measured as one unit) |
| 65 | S&F in repair sub main wiring1100 volts grade multistranded FRLS copper conductors, two runs of single core 2.5 Sqmm along with 2.5 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run along with PVC conduitall as specified and as directed(Note : Three run of2.5sqmm cable and one run of PVC conduit altogether measured as one unit) |
| 66 | M & L for earthing with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia TMT bars reinforced at 10 cm centre to centre both ways,funnel with watering pipe wire mesh and lugs, test point complete all as specified and as directed. |
| 67 | S&F in repairsLED lamp suitable to fit in angle holder of capacity 09 wattsall as specified and as directed. |
| 68 | S&F in repairsbldg securitylight fittingof capacity 30 WattsLED luminaire with pressure die cast housing along with prismatic polycarbonate difuser with IP 66protection all as specified and as directed |
| 69 | S&F in repairsLuminaire Bracket made out of G I tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc and applying two coats of aluminum paintover a coat of red oxide primercomplete all as specified and directed. |
| 70 | S&F in repairsStorage type water heater 25 Ltrs capacity BEE 5 star ratedincludingsteel wired pipe connectionfor hot/cold water supply for inlet and out let water, storage type steel body with copper inner tank and heating element upto 2 KW capacitywith all accessories such as safety valve, thermostate, NRV etc completeall as specified and directed. |
| 71 | S&F in repairsceiling fanswith complete accessories, 230Volts, SP 1200 mm Sweep with BEE 3 Star rating complete, fixing the fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as specified and as directed |
| 72 | S&F in repairsExhaust fansAC single phase 230/ 240 Volts of size 300 mm sweep, steel body AC single Phase. 230Voltswith, blades, and frame and louvers fixed outside withall accessories and fixing the exhaust fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm , etc all asspecified & directed. |
| 73 | S&F in repairsPVC Fresh air fan of 250mm sweep 1200/1400 RPM with louver, and fixing thefan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmmetc completeall asspecified & directed. |
| 74 | S&F in repairsPVC Fresh air fan of 200mm sweep 1200/1400 RPM with louver, and fixing thefan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmmetc completeall asspecified & directed. |
| 75 | S&F in repairsPVC Fresh air fan of 150mm sweep 1200/1400 RPM with louver, and fixing thefan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmmetc completeall asspecified & directed. |
| 76 | S&F in repairsMotor forBAHAR METALLIC GREY exhaust fans280/300 mm sweep, heavy duty, 1400 RPM,AC single phase 230/240 Voltswith blades complete all as specified and directed. |
| 77 | S&F in repairsMotor forexhaust fans300/230 mm sweep, heavy duty, 1400 RPM,AC single phase 230/240 Voltswith blades complete all as specified and directed. |
| 78 | S&F in repairsouter frame suitablefor exhaust fan holding exhaust fan motor upto 280 mm sweep with supporting angle complete all as specified and directed. |
| 79 | S&F in repairsouter frame suitable forexhaust fansholding exhaust fan motor upto 300/230 mm sweep with supporting angle complete all as specified and directed. |
| 80 | S & F in repairs louver suitable forexhaust fan300/230 mm sweep with accessories all as specified and directed |
| 81 | S & F in repairslouver suitable forexhaust fan450 mm sweep with accessories all as specified and directed |
| 82 | S&F in repairsof Single pole & neutral sheet metal enclosure 20 Amps & 240 Voltswith two pin and earth plug and socket complete with one single pole MCB 20 Amps C curves all asspecified & directed. |
| 83 | Inspection, taking down, dismantling of geysers of any type/capacity, cleaning, descaling,includinghydraulic pressure test of container with hand operated hydraulic pump,brazing inner tank, internal wiring and re-assembling & reinstallation on the originalplace after necessary repair/replacement of old parts all as specified & as directed. (Note : Replacement of old parts shall be measured as supply only & paid separately.) |
| 84 | Supply only stainless inner tank of capacity 25 ltrsincluding internally assembly of anytype complete all as specified & as directed. |
| 85 | Supply onlyinternal assembly/apparatus rod unit of any type of capacity 25 ltrs complete all as specified & as directed. |
| 86 | Supply only heating element of 2 KW rating triangular / round typeas per existing size and type including rubber washers all as specified & as directed. |
| 87 | Supply only heating element of 2 KW rating Hexagonal spiral/bend type as per existing size and type including rubber washers all as specified & as directed. |
| 88 | Supply only Thermostatauto cut off of suitable size and type for 25/50 Ltrs capacity of any type all as specified & as directed. |
| 89 | Supply only Indicator lamp red and green colour square/round all as specified & as directed. |
| 90 | Supply only Safety valve / high pressure valve / NRV of exisitng type, ISI marked, all as specified & as directed. |
| 91 | Supply only PVC insulated Copper cable flexible 3 coreof size 40/0.0076ISI marked. |
| 92 | Supply only outer cover of geyser ofcapacity 25 ltrscomplete with all fitting and fixtures as specified & as directed. |
| 93 | Supply only PVC flexible pipe 16mm dia 450mm long with 2 Nos of brass ferrule & rubber washer for hot and cold water all as specified & as directed. |
| 94 | M&L fortaking down the geyser of 25/50ltr capacity, preparation old painted surface of Geyser& spray painting with one coat of synthetic enamel paint usingspray gun including writing MES Noand refixing back in same or other place complete all as specified & as directed. |
| 95 | Taking down ceiling fan 1200mm/1400mm sweep duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, cleaning all dust andspray painting one finishing coat of synthetic enamel paint including writing MES NO and replacing the split pin,rubber pulley etc., includingrefixingand connecting the same complete all as specified and as directed. |
| 96 | Taking down wall mounted fan 300/450 mm sweepduly disconnecting electric lines, preparing the surfaces, filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO etc., includingrefixingand connecting the same complete all as specified and as directed. |
| 97 | Inspection, disconnecting electric connectionand dismantling of ceiling fan/exhaust/wall mounted fan of any type/size, cleaning including oiling and greasing the bearing, tightening of nuts and bolts, re-winding if required, and refixing on the old place after necessary repair / replacement of old parts all as specified & as directed. (Note : Replacement of old parts shall be measured as supply only& paid separately.) |
| 98 | Supply only ball bearing of various sizes / make as required for ceiling fans/wall mounting/exhaust fan includinggreasing complete all as specified and as directed. |
| 99 | Supply only Gun metal bush of any size/make suitable for ceiling fans all as specified and as directed. |
| 100 | Supply only capacitor 2.5 Mfd suitable for ceiling / exhaust /wall mounting fans complete all as specified and as directed. |
| 101 | Supply only capacitor 4.0 Mfd suitable for ceiling / exhaust/wall mounting fans complete all as specified and as directed. |
| 102 | Supply only PVC flexible cable twin twisted core of 23/0.0076 size multi stranded copper conductor suitable for connecting ceiling fans / exhaust /wall mounting fans complete all as specified and as directed. |
| 103 | Supply only Rubber bush with MS bolts, nuts & washers with \"U\" clamps for ceiling fans complete all as specified and as directed. |
| 104 | Supply only motor rotar ring for ceiling fans complete all as specified and as directed. |
| 105 | Supply only motor stator for ceiling fans complete all as specified and as directed. |
| 106 | Supply only down rod of 30/45 cm with nut, bolts and safety pin for ceiling fans complete all as specified and as directed. |
| 107 | Supply only plastic cup with screw for ceiling fans complete all as specified and as directed. |
| 108 | Dismantling / opening the ceiling fan of 1200 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and re-assembling complete all as specified and as directed. |
| 109 | Dismantling /opening the ceiling fan of 1400 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and re-assembling complete all as specified and as directed. |
| 110 | Dismantling /opening the wall mounted fan of 300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed. |
| 111 | Taking down exhaust fans 230 mm/300mm / 450mm sweep from position duly disconnecting electric lines,preparing the surfaces,filling cavities with filler, cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO, re-winding if required,and replacing the split pin,rubber pulley etc.,refixingand connecting complete all as specified and as directed. |
| 112 | Dismantling /opening the exhaust fan of 230 mm/300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and re-assembling complete all as specified and as directed. |
| 113 | Dismantling /opening the exhaust fan of 450 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and re-assembling complete all as specified and as directed. |
| 114 | M&L for Extension of down rod for ceiling fanupto 1.5 mtr including nut, bolts , washers complete accessories all as specified and as directed. |
| 115 | Removing the window type AC/Split type AC of 1.0/1.5/2.0 ton capacity from location servicing the AC, cleaning the condenser and evaporator coil by blower, checking the electrical wiring, repalcement of burnt out wiring terminals, cleaning the air filter, gas charging, adjusting relays etc., replacement of unserviceable spare parts and fixing back atlocation, testing for smooth functioningand commissioning complete allas directed. |
| 116 | Supply and fixPVC insulated 3 core 2.5 Sqmm multi stranded copper conductor cable complete allas directed. |
| 117 | M & L for taking down the split type Air Conditioner of any make from position transporting to a reputed workshop, cutting the suction and discharge line of unserviceable compressor and replace withnew factory made hermatically sealed compressor of same make and type, connecting the suction and discharge line, vacuuming the entire system, arresting all leakages, charging of required quantity of refrigerant, adjusting relays, thermostat etc bringing back and installing in its original position includingtesting for smooth functioningand commissioning for the following capacities complete all as directed:- |
| 118 | 1.5 ton capacity |
| 119 | 2.0 ton capacityNote for item No 70 :- (i)Charging of Gas & supply of Gas will be measured and paid separatelyunder relevent items of this schedule.(ii) Spares will be measured and paid seperately under relevent item of this schedule. |
| 120 | Labour only for charging of refrigrent gas (R-22/410A/134A) of required quantity for split/window type AC including leak detection by using nitrogen gas and arresting leakages if any by necessary brazing and flushing the system complete and testing complete for the following capacities: |
| 121 | 1.5 Ton |
| 122 | 2.0 Ton |
| 123 | Supply onlyfan blades from the condenser motor shaftof same size and type for any capacity of window type AC and water coolers all as specified and directd. |
| 124 | Supply onlythermostat of same make and type for Split/window type AC 1.5/2 ton capacity all as specified and directd. |
| 125 | Taking down blower motor from the window type AC/Spilit type AC, removing the burnt out winding from slots, rewinding with superior quality copper winding wire of higherinsulation level, varnishingdrying the motorcomplete and fixing in position incl testing and commissioning for 1.5/2 ton capacityAir conditioner all as specified and directd. |
| 126 | Supply only condenser unit connecting to the discharge line, brazing, vaccumising & gas charging the unit with required quantity of refrigerant for Split/window type AC of 1.5/2 Ton capacity and testing complete all as specified and directd. |
| 127 | Supply onlyrunning capacitor of 40 MFD suitable for 1.5 ton AC all as specified and directd. |
| 128 | Supply onlystarting capacitor of 80/100 MFD for 1.5 TR / 2 TR AC all as specified and directd. |
| 129 | Supply onlyover load protectionfor split/window type AC of 1.5/2.0 TR capacity all as specified and directd. |
| 130 | Supply onlyrefrigrent gas (R-22/410A/134A) for domestic coolingappliance all as specified and directd.. |
| 131 | Supply only sensor unit of indoor unit of AC of following capacities to suit the ACMakes carrier/Bluestar/Voltas all as specified and directd :- |
| 132 | 1.5 Ton Split type AC |
| 133 | 2 Ton Split type AC |
| 134 | Supply onlyPCBfor split AC of following capacities any type andmake all as specified & directed :- |
| 135 | 1.5 Ton Split type AC |
| 136 | 2 Ton Split type AC |
| 137 | Taking out PCB from split type Air Conditioner 1.5/2 Toncapacity and repairthe same and refixing in original position, testing for smooth functioning complete all as specified and directed. |
| 138 | Disconnect the all electrical connection, removing copper line, discharge line of split type Air conditioner upto 2 Ton capacity alongwith indoor and out door units and all accessories and shifting/reinstalling the whole unit of split type AC in new location with suitable size and length of copper pipe and making the holes in walls etc and testing for smooth functioning complete all as specified & directed. |
| 139 | Supply and fix plastic / coir filter suitable for Split/window type AC 1.5/2 Ton capacity including taking down old unserviceablefilter etc complete all as specified and as directed. |
| 140 | Supply and fix voltage stabilizer suitable of following capacity for Split/window type AC 1.5/2 Ton capacity, operate input range 130 volt to 280 volts, automatic voltage regualation, surge protection etccomplete all as specified and as directed :- |
| 141 | 1 KVA |
| 142 | 2/3 KVA |
| 143 | 5 KVA |
| 144 | S&F in replacement of brass angle valve for gas charging for split Air conditioner of capacity 1.5/2 ton compete all as specified and as directed. |
| 145 | S&F in replacement of brass flare nuts suitable for 1.5/2 ton of SplitAC complete all as specified and directed. |
| 146 | S&F in replacement of swing motor of existing capacity and type for indoor unit of split Air conditionerfins complete all as specified and as directed |
| 147 | S&F in replacement ofMild steelfabricatedclamps for hangingfan including hook as per existing complete all as specified and as directed |
| 148 | Supply and fix Refrigerator electric driven (single phase), capacity310 Litres, double doorBEE 5 star rated, inverter compressor, frost free, toughened glass shelfs, complete all as specified and as directed. |
| 149 | Supply and install Hi wall split units indoor / outdoorwith cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 TON Air Conditioner complete all as specified and as directed. |
| 150 | S&F in replacement ofNitrile rubber insulation for suction and dischaged pipe of split type AC of size 15/19 mm dia complete all as specified and as directed. |
| 151 | S&F in replacement of Soft copper tubing 15mm/19 mm dia with nitrile rubber insulation for split type AC complete all as specified and as directed. |
| 152 | S&F in repair capacitor 2.5 Mfd suitable for ceiling / exhaust /wall mounting fans complete all as specified and as directed. |
| 153 | M&L for groove cutting in wall/floor and making good of distrubed wall/floor with PCC (1:2:4) type B-0 and finishing as per adjoining surfaces all as specified and directed. |