Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for taking out and laying CI/GI pipecomplete all as specifiedand directed. |
| 2 | Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer complete all as specified and directed. |
| 3 | Removal of surplus soil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting pointcompleteall as specified and directed. |
| 4 | Taking down old unserviceable GI/CI pipe 80 mm bore and supply, laying, jointing and testing new cast iron pipe 80 mm bore centrifugally cast class LA confirming to IS - 1536 spigot and socketed ends in any length laid in trenches complete all as specified and directed. (Note : excavation, earth work, CI fitting and new run lead joint shall be measured and paid for separetely under appropriate item of Sch \"A\") |
| 5 | All as per item No 4 above here in before but 100 mm bore |
| 6 | All as per item No 4 above here in before butDI (K-7)100 mm bore |
| 7 | All as per item No 4 above here in before but 150 mm bore |
| 8 | All as per item No 4 above here in before butDI (K-7) 150 mm bore |
| 9 | M&L for repairs and servicing of Jocky pump & Motor Set (Make M/s Crompton Greaves) electric driven Squirrel cage induction motor 3 phase 415 V AC 50HZ opening & cleaninginside of 15 HP motor stator varnishing and drying ,re-windingand duly replacing the following worn out parts ofpump and re -erecting, testing and commissioning complete all as specified and directed. (a) Bearings (b)coupling bolts © coupling rubber bush (d)split casing gaskets (e)shaft sleeves (f) replacing the air cocks grease nipple etc (g) painting the pump & Motor with one coat synthetic enamel grey colour paint. (Fire Pump House No1 & 2) |
| 10 | S&F in replacment cast iron sluice valve80 mm bore with flanged ends, ISI mark with Gun metal spindle, CI gate with brass ring and iron wheel handle with jointing material such as nuts /bolts washers and rubber insertion sheet etc including taking out old U/S sluice valve complete all as specified |
| 11 | All as per srl item No 10 here in before but 100 mm dia. |
| 12 | All as per ser item No 10 above here in before but 150 mm bore |
| 13 | M&L for replacment existing cast iron double air releasevalve of size 80 mm bore replacment of worn out bolts, nuts gasketsif any complete all as specified and directed. |
| 14 | Repair to existing valve pits of internal dimensions 90cm x 90 cm x 90 cmmaking good disturbed/dismantled brick work in cement mortar (1:4) plastering surfaces in CM 1:6, 15mm thick and PCC coping in cement concrete 1:2:4 type B-1 and providing MS cover in replacement made out of MS sheet 3 mm thick duly welded to MS angle iron frame 35x35x5mmincluding frame work as per existing sizewith two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.(a) M&L for brick work using sub class \"B\" (old size bricks) in CM 1:4 (b) M&L for rendering 15 mm thick in CM 1:4 finishing even and fair (c) M&L for PCC 1:2:4 type B-0 (using cum 12.5 mm graded stone aggregate ) as in coping (d) M&L for any type of mild steel work such as frame sheet 3 mm thick including welding (e) M&L for painting two coats of synthetic enamel paint over a coat of red oxide primer to untreated steel surface & prep of surface. |
| 15 | All as per ser item No 14 above here in before but size 75 x 75 x 75 cms |
| 16 | M&L for cleaning & flushing of Static water tank cuboid/circular inshapeof capacity 50000 gallons and the depth of 5 feet , and removing of silt and sludge etc deposited inside the tank and cleaning of entire internal surfaces of tank with bleaching powder incl flushing with water, writing the capacity of tank and date of cleaning with black and white paint, size of text complete all as specified and directed. |
| 17 | All as per item No 16 here in before but SWT of capacity 15000 gallons and the depth of 4.5 feet, complete all as specified and directed |
| 18 | S&F CI double flanged Non -returnvalve, class \"B\", High pressure PN 1.6 conformingto ISI marked,including bolts, nuts, washer and rubber packing all as specified and directed of the 150mm dia bore:- Make : Kirloskar/BIR/Minar |
| 19 | All as per item No 18 above here in before but100 mm bore dia |
| 20 | Supply, install, testing and commissioning of Star Delta starter panel capacity 45 HP panel size 90cm x 60cm x 40cm enclosures cubical weather and vermin proof totally enclosed made out of 2mm thick CRCA sheet machine pressed of suitble size to operate on 3 Phase 4 wire system 415 Volts, 50 HZ double door with front openable with locking arrangement incl inner shutters for mounting switch gear etc, bottom Gland plate with sufficient numbers of circular cable entery holes, including PCC work, prewired complete duly powder coated with comprising of the following:- (i)Coper bus bar 200 Amps capacitor of suitable length insulated heavy heat shrinkable sleeves etc -04 No.(ii) MCCB 160 Amps FP, 415 Volt 35 KA adjustable thermal & adjustable magnetic stting Ics = 100% Icu = 01 No(in commer). (iii) Thermal overload relay D model cap 20 - 40 Amp with thermal protection Adjustable range.(iv) Capacitor box type standard duty box 3Ph. 10 KVA,440 V 50 Hz-01 No. (v) Control MCB SP 6 Amp of control - 02 Nos.(vi) Start - Stopilluminated push button red and green colour cat part No for Red XB5AW31M1N and Green Cat part No XB5AW13M1N.(vii)Digital volt meter AC 0 to 500 vots conzerv TM with inbuilt selector switch duly provided with suitable size of copper insulated wire with universal colored code of size 96x96mm cat part No 30002462 -01 No.(viii) Digital Amp meter AC up to 200 Amp with inbuilt selector switch and CT\"s duly prewired with suitable size of copper insulated wire with universal colour code of size 96x96mm cat part No 30002461 - 01 No. (ix) Phase indicating lamp LED (R,Y,B) type with MCB SP 6 Amp - 01 set of Three.(x) ON/OFF indicating lamp on incomer feeder for status of feeder - 02 No. (xi) Coper bus bar 200 Amps capacitor of suitable length insulated heavy heat shrinkable sleeves etc -04 No. |
| 21 | Taking down existing old unsv LT panel &Supply, install, testing and commissioning ofLT distribution panel, CPRI approved,weather/vermin proof, made out of 3 mm thick CRCA sheet, factory assembled cubicle pattern modular and compartmentalized construction, outdoor type, with front and backside hinged double door with locking arrangement, floor mounted free standing type, duly powder coated, 3 phase and neutral 630 amps current carrying capacity aluminium bus bar with epoxy insulated coating with colour code and insulated support with aluminium earth bus of size 25x3mm with terminal switch, cable galleries, inter connecting bus bar connection/linkage, complete with the following switch gears and mounting the panel board on ground with PCC (1:2:4) type B-1 using 20mm graded stone aggregate bedding upto a height of 45 cm above gorund level, complete all as specified and directed and comprising the following :- (a) MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA- 01 No (In Coming).(b) MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA- 02 No (out Going)(c) MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA- 02 Nos ( Out going)(d) MCCB 4 Pole, 415 V,Adjustable type,100 Amps with breaking capacity 36 KA- 04( Out going)(e) Digital Volt Meter 0-500V- 01 No.(f)Digital Ampere Meter 0-500 A with 3 Nos of CTs.(g) Indicator LED type |
| 22 | Taking down existing old unsv Fire fighting panel &Supply, install, testing and commissioning ofFire fighting panel , (not less than 180cm x 150cm x 50cm ), CPRI approved,weather/vermin proof, made out of 2 mm thick CRCA sheet, factory assembled cubical pattern modular and compartmentalized construction, outdoor type, with front and backside hinged double door with locking arrangement, floor mounted free standing type, duly powder coated, 3 phase and neutral 300 amps current carrying capacity aluminium bus bar with epoxy insulated coating with colour code and insulated support with aluminium earth bus of size 25x3mm with terminal switch, cable galleries, inter connecting bus bar connection/linkage,prewired complete and mounting the panel board on ground with PCC (1:2:4) type B-1 using 20mm graded stone aggregate bedding upto a height of 45 cm above gorund level, complete all as specified and directed and comprising the following :-INCOMER :-(i) Coper bus bar 300 Amps capacitor of suitable length insulated heavy heat shrinkable sleeves etc -04 No. (ii)MCCB 250 Amps FP, 415 Volt 35 KA adjustable thermal & adjustable magnetic stting Ics = 100% Icu -01 No(iii) Star Delta Starter suitable for 75 HPmotor , enclosures cubical of suitble size to operate on 3 Phase 4 wire system 415 Volts, 50 HZ, with sufficient numbers of circular cable entery holes, prewired - 02 Nos, and with eachStar Delta Starter comprising of , MCCB 200 Amps 3P, 415 Volt 35 KA adjustable thermal & adjustable magnetic stting Ics = 100% Icu -01 No , Power contractor 3 pole 200 Amp (AC 3 duty)AC control different level of power and control contacts, inbuilt 1 No + 1 NC auxillary contacts -03 Nos, Thermal overload relay suitable for 75 HPmotor, 3 Ph, 415 V - 02 No complete. |
| 23 | (iv) Star Delta Starter with ,bothfully automatic andManual oparationsuitable for 15 HPJocky pump motor , enclosures cubical of suitble size to operate on 3 Phase 4 wire system 415 Volts, 50 HZ, with sufficient numbers of circular cable entery holes, prewired - 02 Nos, and with eachStar Delta Starter comprising of , MCB 40 Amps 3P, 415 Volt 25 KA-01 No , Power contractor 3 pole 32 Amp (AC 3 duty)AC control different level of power and control contacts, inbuilt 1 No + 1 NC auxillary contacts -03 Nos, Thermal overload relay suitable for 15 HPmotor, 3 Ph, 415 V - 01 No complete. (v) Single phase preventor system supply 415 Volts, 50Hz VSP3 of Make : minilec or equivalent (vi) Control MCB SP 6 Amp of control - 02 Nos . (vii) Start - Stopilluminated push button red and green colour cat part No for Red XB5AW31M1N and Green Cat part No XB5AW13M1N of (viii)Digital volt meter AC 0 to 500 vots conzerv TM with inbuilt selector switch duly provided with suitable size of copper insulated wire with universal colored code of size 96x96mm make : AE or equivalent-01No (xii) Digital Amp meter AC up to 300 Amp with inbuilt selector switch and CT\"s duly prewired with suitable size of copper insulated wire with universal colour code of size 96x96mm ,make : AE or equivalent-01No - 01No(xiii) Phase indicating lamp LED (R,Y,B) type with MCB SP 6 Amp - 01 set of Three. (xiv) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 No Note:- Scop[e included all necessary connection of all equiptment for automatic/ manual operation complete. |
| 24 | M&L for Servicing , testing,repair andload testing certification of following capacity of cranes including any special T&P required at site complete all as specified and directed.Note:-(i)Servicing,Testing,repairandload testing certification of cranes to be carried out at MSD Site of 2 ASD by an expert service engineer and necessaryload testing certificate to be submitted to Engr-In-Charge duly signed by userby contractor.(ii) Item required for replacement will be measured and paid seperately under this schedule(iii)Load of suitable capacity for testing in one shed shall be provided by the Department and be transported to other shed and again brought back to Intial site is contractors responsibility. Rate quoted by contractor shall deemed to include this provision. |
| 25 | 5 Ton Flame Proof Crane |
| 26 | 10 Ton Flame Proof Crane |
| 27 | Opening the main gear box used for up-down movement(1 No), left-right movement(3 Nos), thrustor(5 Nos) and cleaning the gear box/thrustor, including testing and setting the gears/parts for proper functioning, complete change/toping up the gear box/thrustor with recommended lubricants and hydraulic brake fluid, replacement of worn out gaskets,Greasing the reduction gear, steel rope , motor bearings with grease gun includingset-rightand lubricationtheall other moving parts of the crane checking and tightning of rope clamps. Note: Lubrication oil for gear box/thrustor will be measured & paid seperately. |
| 28 | M&L for replacement of brake shoe linerof the cranecomplete all as specified and directed. |
| 29 | M&L for replacement of limit switches with 3&4 contacts in oil tight die cast aluminium housing accurate type with 2 No + 2NC type3SE 404-OE with normal span action.Make :- Siemens |
| 30 | M&L for replacement of power contactorwith 2 NO (normally open) + 2NC (normally colsed) auxillary contacts, rated curent 25A, 110 volt AC |
| 31 | M&L for replacement of power contactorwith 2 NO (normally open) + 2NC (normally colsed) auxillary contacts, rated curent 40A, 110 volt AC |
| 32 | M&L for replacement moveable andfix switcing element with fixing parts for 3 RT14 AC-1 duty power contacter Make : Sieimens . |
| 33 | M&L for repair/maintenance ofInput /Output interfacecard(I/O Card) 18 input & 18 out putoperatingwith in built power supply complete all as specified and directed. |
| 34 | Supply only Grease for lubrication |
| 35 | M&L for repair/maintenance of thrusterbrake shoedrum hydrolic type of EOT crane capacity5/10 ton forthesmooth functioning of brake system |
| 36 | Opening, taking down the defective flame proof electric motor capacity 10 HP from the platform, transportion to workshop cutting and taking out the burnt winding and rewinding the motor with super enamelled copper winding wire of existing gauge, providing cleaninsulation, taping,varnishing, replacement of bearings ,re-assembling, transportion and fixing at site including making connection testing and commissioning the complete all as specified and directed. |
| 37 | Opening, taking down the defective flame proof electric motor capacity 1 or 3 HP from the platform, transportion to workshop cutting and taking out the burnt winding and rewinding the motor with super enamelled copper winding wire of existing gauge, providing cleaninsulation, taping,varnishing, replacement of bearings ,re-assembling, transportion and fixing of site including making connection testing and commissioning the complete all as specified and directed. |
| 38 | Opening, dismantling and taking down defective FLP/WP electro Hydrolic thrustor with integral motor use on upto 1100 V, 3 PH, 50 Hz with max thrust upto 40 Kg, conducting required repair, including repair/replacement of shaft rode, and taking out the burnt 3 PH motor winding, re-winding the motor with super enamelled copper winding wire of existing guage and reassembling after cleaning and all required repair, filling recommended oil, fixing and making connection, testing and commissioning complete all as specified and directed. |
| 39 | Attending complaints and rectification ofelectrical and mechanical defects of EOT Crane of capacity 5/10 Tonand testing after complete all as specified and directed.Note :- (i) The complaint shall be notified to the contractor by Engr-in-Charge or JE E/M telephonically/personnely or by SMS and recorded in the register maintained for the purpose. Contractor shall makenecessary arrangementto attend complaint within 24 hrs failing which penalty @ Rs 1000/ day will be recoverd from contractor for not attending complaint within stipulated time frame. (ii) Cost of any minor nature of repair, replacement of petty items such as nuts, bolts, washers, screws, piece of electric cable upto 0.50 metre length etc is deemed included in the unit rate quoted by the contractor.(iii) Any other major items/repairrequired for rectification shall be measured and paid seperately under respective item of this schedule. |
| 40 | S & F in replacement Steel wire rope for EOT crane 12mm dia 6x36 constn for heavy duty for lifting load confirming to IS 2266 complete all as specified and directed. |
| 41 | S & F in replacement Steel Guardwire4mm dia for supporting suspendedcontroll cablefromEOT crane to Remote switch unit complete all as specified and directed. |
| 42 | S&F in replacement of unserviceableVariable Frequency Drive(VFD)15 HP ,3 Ph ,415 V (+/- 10%) and speed regulation 1:100 , Speed control accuracy =/- 0.5 %fo raing sychronous speed and taking out theold unserviceable VFD from existing panelcomplete all as specified and directed. Make:Siemens or Equivalent |
| 43 | S&F in replacement of Braking resistors sutiableforVeriable Frequency Drive(VFD)15 HP ,3 Ph ,415 Vand taking out theold unserviceable braking resistors complete all as specified and directed. Make : Siemens or Equivalent |
| 44 | S&F in replacement of unserviceableVariable Frequency Drive(VFD)5 HP ,3 Ph ,415 V (+/- 10%) and speed regulation 1:100 , Speed control accuracy =/- 0.5 %fo raing sychronous speed and taking out theold unserviceable VFD from existing panel complete all as specified and directed. Make:Siemens or Equivalent |
| 45 | S&F in replacement of unserviceableVeriable Frequency Drive(VFD)3 HP ,3 Ph ,415 V (+/- 10%) and speed regulation 1:100 , Speed control accuracy =/- 0.5 %fo raing sychronous speed and taking out theold unserviceable VFD from existing panel complete all as specified and directed. Make:Siemens or Equivalent |
| 46 | M&L for taking down unserviceableVeriable Frequency Drive(VFD) 3 Ph ,415 Vof any capacity/Make,from control panelandtransportation to workshop and back, re-fixing, testng and cummissioning completeafter necessary repair /replacement of following items as required complete all as specified and directed. |
| 47 | (a) Power Supply card 440 V, 31/35A |
| 48 | (b)VFD IGBT Module |
| 49 | S&F in replacement of Input /Output interfacecard(I/O Card) 18 input & 18 out putoperatingwith in built power supply complete all as specified and directed. |
| 50 | Supply & install in replacement oftransformer 440v/110v , 2 KVAand taking out the unserviceable transformer from existing panel complete all as specified and directed. |
| 51 | Supply & Fill Oil for the thustor in transformer oil to IS: 335-1983 (EHV Grade) or equivalent complete all as specified and directed. |
| 52 | Supply & Fill Oil Grade EP 140 for gear box model 3510HNG & 320CTcomplete all as specified and directed. |
| 53 | Supply & fill Oil Grade ISO VG220 for gear box Type: G33-10-SN complete all as specified and directed. |
| 54 | M&L pendentpush button forcontrolling all motions ie, start/Stop/ Reset/hoist/micro speed/long travel/ cross travel motions of EOT crane of capacity 10/5 Ton from floor level complete all as specified and directed. |
| 55 | S&F in replacement PVC insulated PVC sheathedcable copper conductor 6 Sqmm 4 core, multistranded FRLS round type fixed for EOT crane complete all as specified and directed. Make : Plaza/ICC/Havells/Rallison |
| 56 | S&F in replacement PVC insulated PVC sheathedcable copper conductor 2.5Sqmm 3 core, multistranded FRLS round type fixed for EOT crane complete all as specified and directed. Make : Plaza/ICC/Havells/Rallison |
| 57 | S&F in replacement PVC insulated PVC sheathed cable copper conductor 1.5Sqmm 4 core, multistranded FRLS round type fixed for EOT crane complete all as specified and directed. Make : Plaza/ICC/Havells/Rallison |
| 58 | S&F in replacement PVC insulated PVC sheathed cable copper conductor 1.5Sqmm 2 core, multistranded FRLS round type fixed for EOT crane complete all as specified and directed. Make : Plaza/ICC/Havells/Rallison |
| 59 | S&F in replacement PVC insulated PVC sheathedmulti corecable copper conductor 1.5Sqmm 19 core, multistranded FRLS round type fixed for EOT crane complete all as specified and directed. Make : Plaza/ICC/Havells/Rallison |
| 60 | S&F in replacement cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 70 to 95 sq mm indoor/outdoor type complete all as specified and directed. |
| 61 | -do- but for cable of size 300 Sq mm |
| 62 | M&L for cleaning the earth pit by removing mud/soil etc from any type of earth pit as required at site and removing rust from the aluminium/copper strip and taking reading of earth resistance by using good quality earth resistance machineand preparing of test results in prescribed format all as directed by Engr in Charge.Each earth pit result to be submitted to Engr-in-Charge duly signed by user and MES rep. Note:EP No should be mentioned on indivudual earth pits and ER value of installation etc complete all as specified and directed. |
| 63 | M&L forrepairingearth pit such as brick/PCC/Plastering work etc as required at site,complete all as specified and directed. |
| 64 | M&L forearth continuity conductor or main earthing lead fixed to wall on batten or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc as required, 25x3mm copper strip complete all as specified and directed. |
| 65 | S&F GI strip 32 x 6mm thick as earthing lead fixed to wall/roofs etc complete all as specified and directed. |
| 66 | S&F Aluminium strip 25 x 3mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. |
| 67 | S&F epoxy base insulators of suitable size 40mm height for fixing GI earth strip on wall/ceiling/floor/poles etc complete all as specified and directed. |
| 68 | Taking out and refixing only copper strip 25 x3mm thick as earthing lead fixed to wall/roofs etc drawn in conduit/GI pipe etc complete all as specified and directed. |
| 69 | Taking out and refixing onlyAluminium strip 25 x 3mmthick as earthing lead fixed to wall/roofs etc drawn in conduit/GI pipe etc complete all as specified and directed. |
| 70 | Taking out and refixing only Aluminium strip 25 x 3mm thick as earthing lead fixed to wall/roofs etc drawn in conduit/GI pipe etc complete all as specified and directed. |
| 71 | M&L earth test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw and GI bolts, nuts and washers complete all as specified and directed. |
| 72 | Supply and spread common salt commercial in trenches to improve the ER value of existing earth pits complete all as specified and directed. (Note : Excavation and earth work shall be measured and paid separetly) |
| 73 | Supply and spread charcoal dust/Breeze in trenches to improve the ER value of existing earth pits complete all as specified and directed. (Note : Excavation and earth work shall be measured and paid separetly) |
| 74 | Excavation in existing earth pit and spreading Common Salt, Charcoal dust and Magnesium sulfate complete all as specified and directed. (Common Salt, Charcoal dust and Magnesium sulfate shall be measured in relevant item of schedule) |
| 75 | S&F PCC earth chamber 1:3:6,RCC1:2:4cover slab with 6mm dia TMT bar ,100mm c/c,MS bar lifting hook including replacement of rustedwatering pipe 20mm bore light grade, UNSV GI funnel with wire mesh complete all as specified and directed. |
| 76 | Earthing with copper Earth Plate Electrode 600x600x3.15mm thick burried directlyin Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with copperEarth Strip of size 20x3mm by means of Bolts, Nuts, Check Nuts and Washers of copperand connected Earthing Testing Point/Bus-bar including GI40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one complete all as specified and directed. |
| 77 | Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directlyin Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with GIStrip of size 32x 6 mm by means of Bolts, Nuts, Check Nuts and Washers of GI or steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one complete all as specified and directed. |
| 78 | Taking out of the unseviceable / repairable parts from the engine with due care, and supply / fixing of the following new and original spare parts including carrying out all related minor and periodical maintenance and ovehauling works as per site requirement suitable for 62.5 to 137.5 KVA capacity DG set, all as specified and directed. |
| 79 | Pre filterCat Part No: 48.117.04.0.00 |
| 80 | Micro FilterCat Part No: 48.117.05.0.00 |
| 81 | L.O. Filter element. Cat Part No: 06.436.01.0.00 |
| 82 | Hose Radiator to pump inletCat Part No: 6H.057.02.0.00 |
| 83 | Hose thermostat to radiatorCat Part No: 6H.057.01.0.00 |
| 84 | Hose water pump to radiator Cat Part No: 4H.073.02.0.00 |
| 85 | Air cleaner elementCat Part No: F6.504.08.0.00 |
| 86 | V-beltCat Part No: 4H.069.01.0.00 |
| 87 | V-belt Cat Part No: 47.305.01.0.00 |
| 88 | Stop solenoidCat No- 4H1503000 |
| 89 | K-Cool Super 25 Ltr ( 8202035125) |
| 90 | Cylinder head gasketCat No-6H00706000 |
| 91 | Taking out of the unseviceable / repairableparts from the engine20 to 50 KVA and supply / fixing of the following new spare parts including carrying out all related minor and periodical maintenance and ovehauling works as per site requirement suitable for kirloskar oil engine complete all as specified and directed:- |
| 92 | Air filter (0458603000) |
| 93 | Lub Oil filter ( 0643601000) |
| 94 | Pre filter ( 4811704000) |
| 95 | Micro filter ( 4811705000) |
| 96 | Hose ( water Pump to radiator) ( 4 H 07302000) |
| 97 | V Belt ( 4 H 06901000) |
| 98 | Fuel pipe(0665410000) |
| 99 | Fuel leak off pipe (4H 24710000) |
| 100 | Fuel Pipe ( 4H 03105000) |
| 101 | Fuel Pipe (4H 0310400) |
| 102 | Set of joints ( 4H 08710000) |
| 103 | Water temperature switch (4626001000) |
| 104 | Set of O Rings ( 4H 08720000) |
| 105 | Set of copper washer (4H08730000) |
| 106 | OFF/ON Start switch ( 49135030000) |
| 107 | Sensor unit for temp gauge (46085020000) |
| 108 | Taking out of unserviceable water pump assy from 137.5KVA DG set including S&F new water pump assy to its original position complete all as directed. Cat Part No -04H 05220000 |
| 109 | Taking out of unserviceable water pump assy from 62.5 KVA DG set including S&F new water pump assy to its original position complete all as directed. Cat Part No -04H 05220001 |
| 110 | Taking out of unserviceable water pump assy from 40 KVA DG set including S&F new water pump assy to its original position complete all as directed. Cat Part No -04H 05220002 |
| 111 | Taking out of unserviceable water pump assy from 30 KVA DG set including S&F new water pump assy to its original position complete all as directed. |
| 112 | Servicing the silancer assembly, remove the complte silencer assembly from DG set by removing nuts bolts complte, including opening the wall of silancer outlet remove the old aspectose rope on silencer complte, remove the blockage complte, reassemble the silencer with DG set with new gasket, nut, bolts & washers, gaswelding on damaged portion on silencer pipe complte DG set 100 KVA |
| 113 | Servicing the silancer assembly, remove the complte silencer assembly from DG set by removing nuts bolts complte, including opening the wall of silancer outlet remove the old aspectose rope on silencer complte, remove the blockage complte, reassemble the silencer with DG set with new gasket, nut, bolts & washers, gaswelding on damaged portion on silencer pipe complte DG set 62.5 KVA . |
| 114 | Servicing the silancer assembly, remove the complte silencer assembly from DG set by removing nuts bolts complte, including opening the wall of silancer outlet remove the old aspectose rope on silencer complte, remove the blockage complte, reassemble the silencer with DG set with new gasket, nut, bolts & washers, gaswelding on damaged portion on silencer pipe complte DG set up to 40 KVA . |
| 115 | Taking out of unserviceable Dynamo Assy from137.5 KVA DG Setincluding S&F new Dynamo assyto its original position complete all as directed . |
| 116 | Taking out of unserviceable Dynamo Assy from62.5 KVA DG Setincluding S&F new Dynamo assyto its original position complete all as directed . |
| 117 | Taking out of unserviceable Dynamo Assy from40 KVA DG Setincluding S&F new Dynamo assyto its original position complete all as directed . |
| 118 | Taking down of unserviceable Radiator from the 137.5 KVA DG Set including connected hose pipe etc and cleaning thoroughly all the tubes and fins etc and carrying out copper brazzing to stop the leakage of the cooling tubes and refixing of the same. |
| 119 | Taking down of unserviceable Radiator from the 62.5 KVA DG Set including connected hose pipe etc and cleaning thoroughly all the tubes and fins etc and carrying out copper brazzing to stop the leakage of the cooling tubes and refixing of the same. |
| 120 | Taking down of unserviceable Radiator from the 40 KVA DG Set including connected hose pipe etc and cleaning thoroughly all the tubes and fins etc and carrying out copper brazzing to stop the leakage of the cooling tubes and refixing of the same. |
| 121 | Supply and fill the Lub oil grade 10 w 15for DG set of 100KVA-3nos,62.5KVA-1 no, 40 KVA-4 nos,30 KVA-2nos,,all asper the requirement, Make : Bharat petrolium/Indial oil all as directed |
| 122 | S&F Diode ( Positive and Negative) suitable for Rotary rectifier 30 KVA Kirloskar alternator including taking out of unserviceable one and all as directed. |
| 123 | S&F Diode ( Positive and Negative) suitable for Rotary rectifier 137.5 KVA Kirloskar alternator including taking out of unserviceable one and all as directed. |
| 124 | Dismantling of FIP, injector nozzles includings connected accessories from 40 KVA Kirloskar DG sets and M/L for carrying out overhauling, calibrationfrom authorised service centre, replacement of damaged spares if any and refixing complete and all as directed. |
| 125 | Dismantling of FIP, injector nozzles includings connected accessories from 62.5 KVA Kirloskar DG sets and M/L for carrying out overhauling, calibration from authorised service centre, replacement of damaged spares if any and refixing complete and all as directed. |
| 126 | S&Fdigital/panel board type battery charger230V AC input 12V DC out put fixed in DG panel board incl.all necessary cable connections |
| 127 | S&F Digital type Genset control unit as per existing all as directed and specified by Engineer-in-Charge |
| 128 | S&F MCCB Three pole 25 KA 63A,A frame Adjustable Thermal&Fixed Magnetic setting cat no.IHLAST0063 make Havells or equilent fixed to LT panel board with necessary arrangement |
| 129 | S&F MCCB four pole 25KA 100A,A frame Adjustable Thermal & Fixed Magnetic setting cat no.IHLAST00100 make Havells or equilent fixed to LT panel board with necessary arrangement |
| 130 | Servicingof AMF panel complte, replacement of burnt copper wiring and controll panel LED indicator etc complte, reassemble the AMF Panel complte DG set upto 137.5 KVA . |
| 131 | M&L Sheet metal enclosure for DBs when MCBs to be used single pole and neutral 4 way 200 Amps rated busbar 240 volt double door |
| 132 | M&L Isolator TPN 415volt 32Amp |
| 133 | M&L PVC rectangular block for mounting,switches,sockets,etc with 3mm thick plastic laminated sheet cover size 250x200x50mm deep |
| 134 | Taking out of unservicable self starter 12 volt and connected unserviceable portion of electric wiring and carring out repairs and overhauling of the self starter up to 30 KVA gen set and replacement of armature, carbon brush, bearing, bendix penion,solenoid |
| 135 | Taking out of unservicable self starter 12 volt and connected unserviceable portion of electric wiring and carring out repairs and overhauling of the self starter for 100 KVA gen set and replacement of armature, carbon brush, bearing, bendix penion,solenoid |
| 136 | Dismentalling of existing worn out Lead acid Batteryfrom DG set and S&F 12 VOLTS PULSE Sealed maintenance free Generator Starting System (Part no. AX 1006139) Make : CUMMINS.all as directed. |
| 137 | Dismentalling of worn out battery clamp and battery connecting wire made of copper 35 sqmm ,1.5 mtr long and replacement of battery clamp heavy dutyin one side and copper lugs on other side suitable sizes fixed complete all as specified and as directed. |
| 138 | S&F machinery description board made out of 4mm thick acrylic sheet and vynil sheet pasted on it with computer cut letters in white colour on blue back ground mounted with the help of stainless steel fastners 6-8 nos lettering shall be inenglish or alfa numeric of suitable size and fonts not more than 100 letters. Display board size will various as per requirement not more than 4 sqmtr in size all as directed |
| 139 | S&F for angle iron frame made of suitable size equal angle iron and MS flat of size 25mmx4mm for mounting of startors/SF units duly painted with one coat of red oxide and two coat of synthetic enamel black colour and including make hole all new nut,bolts and washers for fixing of startor/main switch etc. and grouting at site/pump house includingPCC all as directed. |
| 140 | Attending of urgent complaints in any breakdown of standby Diesel engine with centrifugal pump at Turial location, whenever required, rectify the fault and restore the standby supplywithin 08 hours after receipt of the complaint.Note: (i). The cost of replaced spare parts will be paid and measured seperately. (ii). If complaint is not attended by the contractor within three hours the penality of suitable amount to be impossed to him. (iii) The cost of transportation (to and fro) for all kind of necessary equipment/T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor in this effect.(iv) Complaints shall be lodged by telephonic, so contractor give the telephone number which will be receive the complaint round the clock.(v) Normal routine work shall be not included in urgent complaint. |
| 141 | S&F, in replacement, Battery 12volts, 75AH. Cat pt No. Power safe plus Ep 75-12 of Exide or equivalent |
| 142 | S&F, in replacement, Battery 12volts, 180AH. Cat pt No. Power safe plus Ep 180-12 of Exide or equivalent |
| 143 | S&F, in replacement, lubricating oil filter suitable for DG Set of any type/make and capacity up to 50 KVA, complete all as directed. Make - Bosch / Purolator / Lucas |
| 144 | S&F, in replacement, fuel oil filter suitable for DG Set of any type/make and capacity up to 50 KVA, complete all as directed. Make - Bosch / Purolator / Lucas |
| 145 | S&F, in replacement, fan belts 63 , V-type suitable for DG Set of any type/make and capacity up to 50 KVA, complete all as directed. Make - Bosch / Purolator |
| 146 | S&F, in replacement, fan belts 72, V-type suitable for DG Set of any type/make and capacity up to 50 KVA, complete all as directed. Make - Bosch / Purolator |
| 147 | S&F, in replacement, battery terminals made of brass, suitable for battery of any type/make and capacity, complete all as directed. Make - Bosch / Purolator |
| 148 | S&F, in replacement, piston for DG Set suitable up to 50 KVA capacity, complete all as directed. Make: Kirloskar/ Champion/ Ghelani |
| 149 | S&F, in replacement, piston ring for DG Set suitable up to 50 KVA capacity, complete all as directed. Make: Kirloskar/ Champion/ Ghelani |
| 150 | S&F, in replacement, connecting bearing for DG Set suitable up to 50 KVA capacity, complete all as directed. Make: Kirloskar/ Champion/ Ghelani |
| 151 | S&F, in replacement, crank bush brass for DG Set suitable up to 50 KVA capacity, complete all as directed. Make: Kirloskar/ Champion/ Ghelani |
| 152 | S&F, in replacement, main bearing for DG Set suitable up to 50 KVA capacity, complete all as directed. Make: Make: Kirloskar/ Champion/ Ghelani |
| 153 | S&F, in replacement, center bearing for DG Set suitable up to 50 KVA capacity, complete all as directed. Make: Kirloskar/ Champion/ Ghelani |
| 154 | S&F, in replacement, nozzle for DG Set suitable up to 50 KVA capacity, complete all as directed. Make: Kirloskar/ Champion/ Ghelani |
| 155 | S&F, in replacement, Plunjar Spring for DG Set suitableup to 50 KVA capacity, complete all as directed. Make: Make: Kirloskar/ Champion/ Ghelani |
| 156 | S&F, in replacement, head gasket for DG Set suitable up to 50 KVA capacity, complete all as directed. Make: Make: Kirloskar/ Champion/ Ghelani |
| 157 | S&F, in replacement, oil seal complete for DG Set suitable up to 50 KVA capacity, complete all as directed. Make: Make: Kirloskar/ Champion/ Ghelani |
| 158 | S&F, in replacement, gasket unit complete for DG Set suitable up to 50 KVA capacity, complete all as directed. Make: Kirloskar/ Champion/ Ghelani |
| 159 | Taking out of unserviceable Dynamo Assy up to 50 KVA DG Setincluding S&F new Dynamo assyto its original position complete all as directed . |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail