Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth for foundation etc or for manholes, laying of pipe in soft / loose type of soil and getting out complete all specified and directed. |
| 2 | Returning filling in, including spreading, leveling watering & well ramming in layers not exc 25cm thick complete all specified and directed. |
| 3 | Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified & directed. |
| 4 | Taking up or down (from wall/trenches/floor) existing GI steel tubingand connections, including cleaning for refixing or removal to storeof following sizes:- ( Note-Excavationandearth workwill be measuredandpaid seperately under relevant item. ) |
| 5 | 50 mm bore GI pipe |
| 6 | 40 mm bore GI Pipe |
| 7 | 25 mm bore GI pipe |
| 8 | 20 mm bore GI pipe |
| 9 | 15 mm bore GI pipe |
| 10 | Refixing only GI steel tubingand connections in new or old positionincludingcleaning internally and externally, any grade / make in trenches / wall / floor / ceiling including all type of new fittings i.e. sockets, Tee union elbow etc allas specified and directed offollowing size:- |
| 11 | 50 mm bore GI pipe |
| 12 | 40 mm bore GI Pipe |
| 13 | 25 mm bore GI pipe |
| 14 | 20 mm bore GI pipe |
| 15 | 15 mm bore GI pipe |
| 16 | Supply, fixing & laying only GI tubing medium grade with one socket both end threaded in any length including cutting threading connection in new or old position and all type of GI new fittingsfor laid in trenches/wall/ceiling/ floor/all as specified and directed of following size:- |
| 17 | 50 mm bore GI pipe |
| 18 | 40 mm bore GI Pipe |
| 19 | 25 mm bore GI pipe |
| 20 | 20 mm bore GI pipe |
| 21 | 15 mm bore GI pipe |
| 22 | S&F Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixedingfor following size:- |
| 23 | 50 mm bore GI pipe |
| 24 | 40 mm bore GI Pipe |
| 25 | 25 mm bore GI pipe |
| 26 | 20 mm bore GI pipe |
| 27 | 15 mm bore GI pipe |
| 28 | Taking up CI/DI watermains of following dia including all fittings with spigot and socket ends and lead joints including buring out joints and recovering lead, removal to MES store yard all as specified and directed by Engr-in-Charge. ( Note-1. Excavationandearth workwill be measuredandpaid seperately under relevant item. ) |
| 29 | 100 mmbore |
| 30 | 150 mm bore |
| 31 | Supply & laying , fixing in trenches cast iron pipe with spigot and socket ends centrifugally cast class \" LA\" in any length of following bore dia all as specified and directed. ( run lead joint shall be measured and paid for separately.) |
| 32 | 100mmbore |
| 33 | 150 mm bore |
| 34 | Supply, laying and testing ductile iron pressure flanged type,class K-7 suitable for rubber gasket joints in standard working length confirming to IS-8329/2000 with inside cement mortar lining duly ISI marked laid in trenches complete all as specified and directed of following sizes:. |
| 35 | 100 mm bore |
| 36 | 150 mm bore |
| 37 | M&L for run lead joint with spurn yard & head for spigot and socketed end CI pipe & fittingscomplete all as specified directed by Engr in charge for following :- |
| 38 | 100 mm bore |
| 39 | 150mm bore |
| 40 | M & L for flanged joints with rubber fibre board gasket for cast iron pipes 150 mm bore complete all as specified. |
| 41 | S&F 25 mm dia brass ferrules screwed both end for iron pipe complete all as specified and directed by EIC. |
| 42 | S&F 20 mm dia brass ferrules screwed both end for iron pipe complete all as specified and directed by EIC. |
| 43 | Supply and fix cast iron flanged sluice valve of class 1.6 PNinstalled complete with ISI marked (IS-14846) with gun metal spindle and hand wheelall as specified and directed by EIC including taking down old unserviceable one of following size |
| 44 | 100 mm bore |
| 45 | 150 mm bore |
| 46 | Supply and fix CI reflux ( non return ) valve 100 mm bore as per IS 5312 with GM working parts both ends flanged and suitabely machined and drilled for and including required nut , bolts washer rubber/ fiber packing complete all as specified and directed.Make Remco/ Kirlosker. |
| 47 | S & FCIfittingsfor spigot, socket pipessuch as, bends( any type radius and angle) , tapers any type (straight bends inincreasing , decreasing or double socket etc.) Tee pieces ,single branch, \"Y\" junctions , double branch, cross( all sockets or socket and spigot), collars , caps and plugs suitable up to 150 mm bore complete all as specified . |
| 48 | All as per item 17 abovebut fixing only. |
| 49 | Material & labour for Ductile iron fittings or special for flanged ends size up to 150 mm bore pipes conforming ti IS : 1538, like bends (any radious and angle ) taper any type ( Straight, end increasing, decreasing or double socket etc) tail pieces single branches, Ý\" junction double branches,crosses (all flanged ends) complete all as specified & directed. |
| 50 | M&L for float valve high pressure with polythene float and fly complete, screwedfor iron pipe or PVC ferrule and fixed in all as specified and directed of following size:- |
| 51 | 15 mm bore |
| 52 | 20 mm bore |
| 53 | S & F chromium platedfancy type bib taps,cast copper alloy with crutch or butterfly handel,screwed down screwed for iron pipe or for brass ferrule and fixed for 15 mm bore dia of pipe complete all as specified and directed. |
| 54 | Demolition of oldvalve pit and M & L for brick masonry valve pit of size 900mm X 900mm X 900 mm (internal size) complete with excavation, earth work, PCC 1:3:6,type C-2 ( using 40 mm graded crushed stone aggregate) in foundation, brick work in cement mortar 1:6,internal plaster 10 mm thick rendering in cement mortar 1:4 (internally ) 4 mm thick mild steel plate cover inccluding mild steel iron frame including material and labour for preparation of new steel iron surface & applying two coat of synthetic enamel paint over a coat of red oxide primer and including locking arrangement complete suitable for upto 150 mm dia pipe complete all as specified and directed |
| 55 | Material and labour for cutting/tapping the existing CI pipe line upto 150 mm bore in position and reducing to required length for inserting of new tee of required size,branches including jointing with lead etc complete all as specified. |
| 56 | Dismantling and taking out complete assy of 15 HP ;capacity make Kirloskar submersible pump from bore well keep aside for repairing/assembling by replacemenrt of parts all as specified and directed.(Parts to be measured and paid spearately). |
| 57 | Dismenteling of complete bowl assy of 4 stage ,replacement of impellers GM , impeller rings,bearing sleeve ,ruber bushes ,neck rings ,distance bushes, thrust screws,center guid rings, connection pieces etc as per matching size and sample and requirement of pump complete all as specified and directed. |
| 58 | Dismantling of mortor taking out rotor complete and carrying out rewinding to starter by using supper quality of copper conductorof matching size in guage and weight using best quality of insulationmaterial taping varnishing drying backing complete all as specified and directed. |
| 59 | Assembling fitment with the pump and making fit for lowering with necessary connection with starter / panel with testing complete all as specified. |
| 60 | Supply and lowering / fixing MS coloumn pipe 80mm bore flange type and 7.1 mm thickness ERW steel pipe including jolinting material i.e. rubber packing nuts, / bolts washers etc. |
| 61 | Development of existing bore well by means of 250 PSI Air compressor for not less than 08 hrs under dirctiions of Engineer - in - Charge complete all as specified and directed. |
| 62 | Development of tube well by over pumping until clear discharge is met. |
| 63 | M & L for painting of valve pit cover of MS sheet of size n exc 0.90 X 0.90 M with two coat of blue synthetic enameled paint internally & externally including prepration of surface complete all as specified and directed at site. |
| 64 | Supply , installation / lowering and commissioning the submersible pump set with strove lined non return valve directly coupled with and including induction motor of 20 HP capacity for operation on 415 Volts +/- 10% , three phase , 50 Hz,copper wound & pump having 4 stage complete with necessary accessories specified by manufacturer , suitable for 1200 LPMdischarge of water at 48 meter head all as specified and directed. Make-Kirlosker/ KSB / CRI /Crompton . (Note :- rates for lowering of pump & column pipe of size 80 mm bore flanged type & M&L for new jointing material i.e. rubber packing ,nuts , bolts and washer etc.will be measured and paid separately under respective item of schedule) |
| 65 | Supply & fix in replacement fully automatic star delta stater for submersible pump comprising with over load relay , amp meter, volt meter suitable for 20 HP capacity Kirlosker/CG make submersible pump complete all as specified and drected. |
| 66 | Supply, connecting and testing (in replacement or for extention) of PVC insulated and sheathed water proof cable wih standard copper conductor flat submersible cable 1100 V grade complete all as specified for cross section area of 16 Sqmm 3 core. |
| 67 | Cleaning of OHT having height upto 18 mtr & capacity 20000 gallons by removing deposited sand,mud,silt and taking out from the tank ,Flushing out the mud water by scraping out deposited mud on surfaces insied by using steel brush complete specified and directed & Putting adequate quantites lime mixed water and removing the same through wash out followed by poring bleaching solution all around the bottom of the tank and marking the date of cleaning with synthetic enamel paint on external surface including two coats of synthetic enamel paint on all pipes of different sizes such as rising main, delivery pipe, over flow pipe & wash out pipe etc. as per colour code complete all as directed at site. |
| 68 | M&O for periodical maintenance / servicing of DG set consisting of normal repairs such as tightening of nut bolts, greasing, checking of lube oil level , fuel tank, fuel pipes, water / coolent level in radiator,cleanness of air filter, condition of hose ,V belts , battery connections / checking of battery terminals , level of distilled water in battery and checking of all other visual parts of DG set including routine cleaningof dust with vacuum cleaner etc ( once a week or as required and directed by Engr-in-Charge / JE.)(a ) For DG Set 62.5 KVA, Make;-GREAVES COTTON LTD(i) The maintenance cost of DG Set for month shall deemed to comprises of cost of labour employed for the purpose, T&P used and other petty items such as cotton waste, Kerosene oil, Grease, nuts, bolts etc. (ii)M & L for replacement of spares parts and oil will be measured and paid under relevant items of schedule ‘A’. |
| 69 | All as per item 38 above butDG Set 40 KVA, Make - KIRLOSKAR |
| 70 | All as per item 38 above butDG Set 30 KVA at ARO Make - KIRLOSKAR |
| 71 | All as per item 38 above butDG Set 30 KVA at pump house No 2, Make - KIRLOSKAR |
| 72 | Supply and fix in repair following spare parts of DG Set 62.5 KVA, Make -Make GREAVES COTTON LTD |
| 73 | Diesel Filter ( fuel filter) |
| 74 | Mobile filter (lube oil filter) |
| 75 | Air filter (primery & safety element) including air cleaner hose with T bolt and clamp. |
| 76 | Breather hose with clamp as per existing size and sample |
| 77 | V Belt for fan drive. |
| 78 | Starter ring |
| 79 | Fuel pipe with copper washer and banjo bolt ( fuel tank to fuelfilter) |
| 80 | Fuel pipe with copper washer and banjo bolt( fuelfilter to pump inlet) |
| 81 | Radiator drain cock with plug and adoptor. |
| 82 | Supply and fix in repair following spare parts ofDG Set 40 KVA, Make - KIRLOSKAR |
| 83 | Diesel Filter ( fuel filter) |
| 84 | Mobile filter (lube oil filter) |
| 85 | Air filter (primery & safety element) including air cleaner hose withT bolt and clamp. |
| 86 | Breather hose with clamp as per existing size and sample |
| 87 | O ring for breather plate. |
| 88 | V Belt for fan drive. |
| 89 | Starter ring |
| 90 | Fuel pipe with copper washer and banjo bolt ( fuel tank to fuelfilter) |
| 91 | Water pump belt - V section |
| 92 | Supply and fix in repair following spare parts ofDG Set 30 KVA, Make - KIRLOSKAR |
| 93 | Diesel Filter ( fuel filter) |
| 94 | Mobile filter (lube oil filter) |
| 95 | Air filter (primery & safety element) including air cleaner hose withT bolt and clamp. |
| 96 | Breather hose with clamp as per existing size and sample |
| 97 | V Belt for fan drive. |
| 98 | Starter ring |
| 99 | Fuel pipe with copper washer and banjo bolt ( fuel tank to fuelfilter) |
| 100 | Fuel pipe with copper washer and banjo bolt( fuelfilter to pump inlet) |
| 101 | Radiator drain cock with plug and adoptor. |
| 102 | M/L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc including replacement of fuel tank lid by new one for DG set of capacity 30 KVA to 62.5 KVA DG set |
| 103 | Taking down the defective water pump from DG set of any type and capacity and replace with new one for DG set of cap 30 KVA to 62.5 KVA all as directed . |
| 104 | M&L for Repair to Radiator assy by disconnecting the radiator from engine frame and servicing/cleaning with acid and brazing where required to stop leaking tubes/joints etc. cleaning fins and re-fixing the same for DG set 30 KVA to 62.5 KVA all as directed . |
| 105 | Supplying and filling coolant as recommended by manufacturer in DG sets. |
| 106 | Supplyin sump / topping up engine oil, multi grade 20w/40 in engine or replacement of engine oil for DG SETS.Make: Indian oil / Hindustan petroleum / Castrol. |
| 107 | Supplyand fix in replacement battery of capacity 150 Ah , 12 V suitable for DG sets |
| 108 | Supplyand fix in replacement battery of capacity 110 Ah , 12 V suitable for DG sets |
| 109 | Supply and filling distilled water in battery . |
| 110 | M&L for replacement of brass battery terminal suitable for lead acid battery 12 V any AH . |
| 111 | M &L for Removing the fuel injection pump (FIP) from DG set cap 30 to 62.5 KVA and carry out servicing and calibration from authorised maker\"s work shop including replacement of injectors, nozzles, etc. and refitting the same for smooth and efficient functioning all as directed. Note :-Repairs will be carried out from authorised workshop of MICO or manufacturer of DG set. |
| 112 | Taking down defective self starter and supply and fix in replacement self starter for 30 KVA to 62.5 KVA DG set of Kirloskar make. |
| 113 | Supply and fix in replacement AVR ( automatic voltage regulator ) for DG sets 30 KVA to 62.5 KVA complete all as specified and directed. |
| 114 | Supply and fixing in replacement DG set controller as per existing in control panel of DG Set 30 KVA to 62.5 KVA , Make - Kirloskar, duly programmed by manufacturer ,testing and comissioning complete all as specified and directed. |
| 115 | Dismantling and taking out all burnt windings from Armature, Main field, stator field and armature complete assembly fitted in 30 KVA DG Sets and M& L for rewinding of alternator with super enameled copper wire of existing gauge size and turns and makers specifications including all associated insulating material such as separator and heat varnishing etc including both inner and outer bearing of existing size and model, after complete repair of alternator re-assembling and refixing the same in position including testing complete all as specified and directed. |
| 116 | S & F in repair on load changeover switch with sheet steel enclosure,I-O-II 3 phase & neutral,415 V, 50 Hz, 250 Acomplete all as specified and directed. |
| 117 | S & F in repair on load changeover switch with sheet steel enclosure,I-O-II 3 phase & neutral,415 V, 50 Hz, 200 Acomplete all as specified and directed. |
| 118 | S & F in repair on load changeover switch with sheet steel enclosure,I-O-II 3 phase & neutral,415 V, 50 Hz, 100 Acomplete all as specified and directed. |
| 119 | Supply and fixing in replacementheating element of 1.5 KW /2.0 any type , as per sample ISI marked. |
| 120 | Supply & replacecomplete siphon assembly as per existing sample including rubber washer andnuts & bolts suitable for water heater of capacity 25 Ltrs of any make. |
| 121 | S & F in replacement SS inner tank as per size and samplefor geyser of capacity 25 ltrs. |
| 122 | Supply and fixing in replacement thermo state switch suitable for above geyser ISI marked. |
| 123 | Supply and fixing in replacement PVC pipe pipes of 450 mm longbest quality, heavy duty for geyser of 15 mm dia with brass connecting nuts/couples. |
| 124 | S & F in replacement stop cocks brass CP 15 mm dia suitable for above geyser ISI Marked. |
| 125 | Supply and fixing in replacement PVC insulated copper conductor cable 3 core 6 Sq mm 660/1100 volts grade make Kalinga/Finolex/Rallison. |
| 126 | Supply and fixing in replacement of plug top 3 pin 15 Amps. |
| 127 | Supply and fixing in replacement indicator lamps red and green colour 230 volts 50 Hz AC supply. |
| 128 | Supply and fixing in replacement safety valve to blow of at high ratedtemperature having latestISI marked. |
| 129 | Supply and fixing in replacement glass wool around the geyser. |
| 130 | Collecting and transporting of desert coolers from MES store yard/user bldgs to work shop and overhauling of fan motar, oiling to vertical pump including replacement of unserviceable bolts and nuts with washers, clamps & wood wool pad (set of 3)of good quality etc.including M & L for preparation of steel surface of desert coolers followed by painting with one coat of synthetic enameled paint complete on metallic surface external and internal complete and returning back to MES store yard/user locations complete all as specified and directed. |
| 131 | Supply & Fixing in repair fan motor 1/7 HP or any HP complete set with arm and fan blade etc. ,230 volt,50Hz cycles A/C supply of make Summer Cool/CG /Havells/Bajaj complete in all respect. |
| 132 | Supply & Fixing in repair submersible water lifting pump,single phase suitable for desert coolers complete in all respect. |
| 133 | M & L for replacement of unserviceable sealed unit (compressor) of water coolers with new sealed unit (recommended by manufactorer) sealed unit make kirloskar/Tecumsha for water cooler make Shri Ram / Usha / Voltas or Blue Star capacity from 40/80 Ltrs. |
| 134 | Supply & Fixing in repair thermostatic switch for water cooler of capacity 40/80 Ltrs |
| 135 | Supply & Fixing in repair chromium plated push cock, self closing, spring loaded type 15mm dia. |
| 136 | Supply & Fixing in repair blower motor as per size & sample in water cooler, commissioning and testing complete in all respect. |
| 137 | M & L complete servicing of water cooler by cleanning of coils with caustic soda, removal of rust from sheetmetal frame, cleaning of tank and cheackingof water connection and fixing in original position complete in all respects. |
| 138 | Repair to refrigerators complete by cleaning of system properly with CTC. Charging refrigerant including replacement of unserviceable sealed unit (Compressor) of Refrigerator with new sealed unit, recommendedby manufacturer of 390/320/340 Ltrscapacity. |
| 139 | Repair to refrigerators complete by cleaning of system properly with CTC. Charging refrigerant including replacement of unserviceable sealed unit (Compressor) of Refrigerator with new sealed unit, recommendedby manufacturer of 230/165 Ltrscapacity. |
| 140 | Supply andfixing in repair of box type relayfor any make and capacity upto 390 ltrs refrigerator. |
| 141 | Supply andfixing in repairthermostatic switch for any make and capacity upto 390 ltrs refrigerator. |
| 142 | Repair to window / Split typeAir conditioner by replacement of unserviceable sealed unit i.e.compressor (rotery or hermetic) ,cleaning of system properly with CTC and charging the refrigerant(including cost of refrigerant ) recommended by manufacturer of AC including commissioning and testing complete all as specified and directed by Engr - in - Charge at site for1.5 TR Window / Split type AC. |
| 143 | S & F in replacementrelaysuitable for split type AC / window type AC upto capacity of 1.5 TR. |
| 144 | S & F in replacementover load protector suitable for split type AC of 1.5Ton. |
| 145 | S & F in replacement for air conditioners, capacitor 36 / 45 / 50 +6 mfd +/- 5% ,440 V AC . |
| 146 | S & F in replacementthermostatic switch suitable for 1.5 / 2 ton AC make Renutrol. |
| 147 | S & F in repalcement fan motor with blade as per size and sample suitable for FCU unit of Split type AC of capacity1.5 Tonof make LG/Voltas/Blue Star complete all as specified and directed. |
| 148 | S & F in repalcement blower fan motorfor indoorunit of Split type AC of capacity1.5 Tonof make LG/Voltas/Blue Star complete all as specified and directed. |
| 149 | S & F in repalcementfan motor with bladefor Window type AC of capacity1.5Tonof make LG/Voltas complete all as specified and directed. |
| 150 | M & Lfor gas charging in split type AC unit 1.5 TR capacity using refrigerant as per standard practice after flushing, vacuuming including detecting leakage, rectification leakage, commissioning and testing complete all as specified and directed. |
| 151 | All as per item 120 above but for window type AC unit of capacity 1.5 TR capacity . |
| 152 | S & F in repairpower PCB as per sample suitable for 1.5/2 TR Split type AC, making connection & testing complete all as specified and directed. |
| 153 | S & F in repair copper connection pipe with union at both ends and with insulation, between FCU unit and indoor unitof length twelve feetfor 1.5/2 TR Split type AC, making connection & testing complete all as specified and directed. |
| 154 | S & F in repairdrain hose pipe suitable for 1.5 / 2 TR split type AC. |
| 155 | M & L for complete servicing of Air conditioner window/split type including cleaning of colling coil and condenser by caustic soda solution including removal of dust by using blower/brush to external fins and from beneath assets, cleaning of base tray properly including oil to fan & condenser motor, tightening of all electrical connections with proper alignment including fitments in their locations and repairs of suction &discharge tubes complete in all respects. (Note :-Filling of refrigerant if required or parts to be replaced will be measured and paid separately under respective items) |
| 156 | Repair of voltage stabilizer of capacity 5 KVA/4KVA by carying out rewinding of main transformer, replacement of volt meter, relay, timer and IC circuit as requiredand making functional and testing complete all as specified and directed . |
| 157 | M&L earthing complete with galvanised steel earth plate 600X600X6.3 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.5 m below GL) connected with GI earth strip of32X6 mmas earthing leadsby means of bolts, nuts, check nuts and washers besideWelding / brazing at all joints as shown on drawings and including excavation, earth work.GI pipe light grade40 mm bore for protection of GI earth strip from earth electrode to and including the earth test point, supplying and laying charcoal dust, common saltPCC (1:2:4) type B1chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -Iand conected to earth test point including testing complete all as secified and directed. |
| 158 | Supplying & Fixing GI electrode chemical earthing ofhigh conductive, corrosion resistant, CPRI testedmaintenance free chemical earthing pit, to achive earth resistance value less than or equal to 3 Ohme & EN voltage < 02 V , pipe in pipe technology based in which primary conductor (Pipe) having 40 MM dia and secondary conductor having 80 MM dia. The primary conductor is inserted into secondray conductor and spce between secondary and primary conductor of earthing electrode should be filled with crystalline compound. The length of this electrodes is min 3000 MM (3 meters) andearth pit\"sbore hole should be of dia 200 to 250 mmand min depth3.50 meters. Length of electrode will be increase with connecting of 32 x 6 mm GI strip extra, and total depth of earthing electrodes should not less than 3.50 meters. Around the earth electrode earth pit bore hole should be backfilled with minimum50 Kg of ground enhencement compoundERIC ( ERIC Contains mixture of Silica sulphate, Alumina, Iron Oxide, titanium Oxide, Calcium Oxide, Magnesium Oxide,Sodium Oxide, Zink Oxide etc. ). including RCC earthing pit having 450 x 450 CI chamber cover all as directed by Engineer-in-Charge.( Note : If less than 3 Ohme result has not acheived at site the contractoris responsible to do grid system to achieve the desired result and no extra payment shall bemade tothe contractor for making grid system) Make Remedies, Model - RSPL-G803 / MRS agency Model G-80. |
| 159 | Supplying & Fixing Copper electrode chemical earthingofhigh conductive, corrosion resistant, CPRI testedmaintenance free chemical earthing pit ( each set will be in grid of three earthing ) to achive earth resistance value less than or equal to 2 Ohme & EN voltage < 02 V, pipe in pipe technology based in which primary conductor (Pipe) having 40 MM dia and secondary conductor having 80 MM dia. The primary conductor is inserted into secondray conductor and spce between secondary and primary conductor of earthing electrode should be filled with crystalline compound. The length of this electrodes is min 3000 MM (3 meters) andearth pit\"sbore hole should be of dia 200 to 250 mmand min depth3.50 meters. Length of electrode will be increase with connecting of 20 X3.15 mm copper strip extra, and total depth of earthing electrodes should not less than 3.50 meters. Around the earth electrode earth pit bore hole should be backfilled with minimum50 Kg of ground enhencement compoundERIC ( ERIC Contains mixture of Silica sulphate, Alumina, Iron Oxide, titanium Oxide, Calcium Oxide, Magnesium Oxide,Sodium Oxide, Zink Oxide etc. ). including RCC earthing pit having 450 x 450 CI chamber cover all as directed by Engineer-in-Charge.( Note : If less than 1 Ohme result has not acheived at site the contractoris responsible to do grid system to achieve the desired result and no extra payment shall bemade tothe contractor for making grid system.) Make Remedies / MRS agency. |
| 160 | Taking down carefully copper/aluminium point wiring (Light,fan,socket or power) complete fitting such as switches, ceiling rose, regulator, sockets etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors, etc. all as specified and directed. |
| 161 | M&L light fan point controlled by one switch with PVC insulated, unsheathed , multi stranded, single core copper conductor FRLS ( Flame Retardant Low Smoke) cable 1.50 Sqmm suitable for fixing in concealed PVC conduit of size not less than 20 mm dia with metalflush boxes including white cover plate with frame of required module.Metal flush box should not less than2 mm thickduly painted inside and outside with two coats of synthetic enamel paint over one coat of red oxide primer of requiredmodule suitable for housing modular switches, socket, fan regulator etc. PVC insulated, unsheathed, multi stranded, single core copper conductor FRLScable 1.50 Sqmm used as earth wire to commen earth and connected to common dolly drawn in same conduit all as specified. |
| 162 | All as per item No 131 above but one 3/5 pin socket out let5 amp on same board with other switches. |
| 163 | All as per item No 131 above but socket out let 5 amp on independent board. |
| 164 | All as per item No 131 above but One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq.mm size |
| 165 | All as per item No 131 above but one light point controlled by two two way switches. |
| 166 | All as per item No 131 above but socket out let 3/6 pin 15 Amp with 2.5 sq mm size copper conductor for power point on indipendent board. |
| 167 | Supply & Fixing switch modular single pole, one way 6 Amp ,01 module. |
| 168 | Supply & Fixing switch modular bell push 6 Amp ,01 module. |
| 169 | Supply & Fixing switch modular , two way 6 Amp ,01 module. |
| 170 | Supply & Fixing switch modular single pole, one way 16 Amp ,01 module. |
| 171 | Supply & Fixing modular socket 6 Amp-2/3 pin combined ,2 module. |
| 172 | Supply & Fixing modular socket 6/16 Amp-2/3 pin combined ,2 module. |
| 173 | S&F Modular electronic type step fan regulator, 120 W-2 module. |
| 174 | M&L lightfan pointcontrolled by one switch with PVCinsulated,unsheathed , multi stranded , single core copper conductor cable 1.50 Sqmm suitable for fixing in concealed conduit 20 mm dia with sunken pressed steel terminal boxes 2 mm thick of required size , duly paintedinside and outside with two coats of synthetic enamel paint over one coat of red oxide primer including3 mm thick plastic laminated sheet cover housing switches ,socket, fan regulator etc. PVC insulated, unsheathed, multi stranded, single core copper conductor cable 1.50 Sqmm used as common earth wireand connected to common earth dolly& drawn in same conduit all as specified. |
| 175 | All as per item No 144 above but one 3/5 pin socket out let5 amp on same board with other switches. |
| 176 | All as per item No 144 above but socket 5 amp on independent board. |
| 177 | All as per item No 144 above but One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq.mm size |
| 178 | All as per item No 144 above but one light point controlled by two two way switches. |
| 179 | All as per item No 144 above but socket out let 3/6 pin 15 Amp with 2.5 sq mm size copper conductor for power point on indipendent board. |
| 180 | Supply & Fixing switch piano flush type single pole one way 5 Amp. |
| 181 | Supply & Fixing bell pushflush type switch. |
| 182 | Supply & Fixing switch piano flush type two way 5 Amp. |
| 183 | Supply & Fixing socket 3/5 pin 5 Amp flush type. |
| 184 | Supply & Fixing switch socket combination 3/6 pin 5/15 Amp universal type. |
| 185 | Supply & Fixing electronic stepped typefan regulator. |
| 186 | Supply & Fixing call bell ding dong type 230 Volts AC supply. |
| 187 | Supply & Fixing ceiling rose surface backlite 65X20 mm two to three terminals complete all as specified and directed. |
| 188 | Supply & Fixing lamp holder PVC / Ploycarbonate type. |
| 189 | Taking down carefully copper/aluminium power/sub main wiring ofany size / typeall as specified and directed. |
| 190 | M & L for power/sub main wiring with four runs of single core 6 sqmm size and two run of single core 6.0 sqmm (green colour as earth continuty conductor ) PVC insulated unsheathed multi stranded copper conductor cables drawn through and including rigid PVC concealed conduit complete all as specified and directed.( Note - Four runs of 6 sq mm single core copper conductor and two runs of 6.0 Sq mm copper conductor shall be measured as one unit length.) |
| 191 | M & L for power/sub main wiring with two runs of single core 4 sqmm size and one run of single core 4.0 sqmm (green colour as earth continuty conductor ) PVC insulated unsheathed multi stranded copper conductor cables drawn through and including rigid PVC concealed conduit complete all as specified and directed.( Note - two runs of 4 sq mm single core copper conductor and one runs of 4.0 Sq mm copper conductor shall be measured as one unit length.) |
| 192 | M & L for power/sub main wiring with two runs of single core 6 sqmm size and one run of single core 6.0 sqmm (green colour as earth continuty conductor ) PVC insulated unsheathed multi stranded copper conductor cables drawn through and including rigid PVC concealed conduit complete all as specified and directed.( Note - two runs of 6 sq mm single core copper conductor and one runs of 6.0 Sq mm copper conductor shall be measured as one unit length.) |
| 193 | Supply & fixing earth plug enclosure (plug and socket ) with MCB, SP 20 Amps modular type complete all as specified and directed . |
| 194 | Taking down existinglight fitting of any type,make & capacity . |
| 195 | Supply and fixing energy saving LED lights fitting 1x 20W, 220V, AC, natural white / warm whitedecorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, including its all acessoriescomplete all as specified and directed . |
| 196 | Supply and fixing engineering plastic batten with white acrylic coverLED light ( integrated LED channel) natural white / warm white,energy saving complete with its all acessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed of 09 W . |
| 197 | Supply and fixing recess/surface mounting LED luminaire of size 600 mmx 600 mmwhite 35/36 watt, 230 volts with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. |
| 198 | Supply & Fixing recess/surface mounting sleek round / Square LED downlight luminairewhite 15 Watt , 230 Volts, complete withdriver, connector block ,etc, complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor of suitable size. |
| 199 | Supply & Fixing integral LED bulkhead luminaire, 10 W, 230 Volts, IP 65 protection decorative surface mounted , complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor of suitable size. |
| 200 | Supply & Fixing in replacement Bldg securityLED light fittings with pressure dia cast aluminium of 35 watts and including and connceting up ceiling rose and fittings with 3 core, PVC insulated multistranded copper conductor cable of 1.5 Sqmmcomplete all as specified and directed |
| 201 | Supply & Fixing in replacement LED lamp 12 Watt. |
| 202 | Supply & Fixing in replacement LED lamp 9 Watt . |
| 203 | Supply and fixing rechargeable LED bulb Cool Day light 9/10watts having Luminous Efficacy range lies between ( ≥100 and <105 ) lm/W,CRI 80 as per BEE guidelines Long Life 25000 hours , colour temp 6500 K , frosted glass min back up time 4 Hrs after charge, In-built surge protection of 3 KVA 220V,ACcomplete all as specified and as directed. |
| 204 | Taking down old U/S MCCB/MCB DB of any type, make complete all as specified and directed. |
| 205 | Supply & Fixing sheet metal enclouser MCCB DBIP 43 double door bus bar neutral link earth bar and din rail TPN 4 way complete all specified and directed. |
| 206 | Supply & Fixing sheet metal enclouser MCB DB double door bus bar neutral link,earth bar and din rail SPN 12 way complete all specified and directed. |
| 207 | Supply & Fixing sheet metal enclouser MCB DB double door bus bar neutral link,earth bar and din rail SPN 8 way complete all specified and directed. |
| 208 | Supply & Fixing sheet metal enclouser MCB DB double door bus bar neutral link,earth bar and din rail TPN 4 way complete all specified and directed. |
| 209 | Taking down old U/S MCCB / MCB of any type,make complete all as specified and directed. |
| 210 | S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz,100 Amps with breaking capacity 16 KA fixed type all as specified and directed. |
| 211 | S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz,125 Amps with breaking capacity 16 KA fixed type complete all as specified and directed. |
| 212 | Supply & Fixing MCB TPN 16 to 32 Amps415 volts, 10KA \"C\" curve. |
| 213 | Supply & Fixing MCB TPN 40 to 63 Amps415 volts, 10KA \"C\" curve. |
| 214 | Supply & Fixing MCB SPN 32 Amps240 volts, 10 KA, \"C\" curve. |
| 215 | Supply & Fixing MCB SPN 40 to 63 Amps240 volts, 10 KA, \"C\" curve. |
| 216 | Supply & Fixing MCB SP 5 to 32 Amps240 volts, 10 KA, \"C\" curve. |
| 217 | Taking down ceiling fan of any sweep from its position opening the fan for inspection of worn out/ unserviceable parts. Repairing with replacement of unserviceable parts if required cleaning of blade and body properly oiling, greasing of bearing/ bush all as specified and fixing the fan in position complete all specified and directed ( Note :- Parts to be replaced will be measured and paid separetly). |
| 218 | M & L for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning of dust etc. |
| 219 | Transporting of unserviceable ceiling fans of 1200 mm sweep to work shop and carrying out rewinding to the starter by using superior quality enameled copper conductor of matching size in weight gauge, application best quality of supper enameled insulation material tapping varnishing drying and re-fitment with testing complete all specified and directed. |
| 220 | Ditto but for ceiling fan of 1400 mm sweep 230 volt AC 50 Hz. |
| 221 | Ditto but for heavy duty exhaust fan 300mm sweep 230 volt AC 50 Hz. |
| 222 | Dittobut for pedestal fan 400mm sweep 230 volt AC 50 Hz. |
| 223 | Ditto but for wall mounting fan 400mm sweep 230 volt AC 50 Hz. |
| 224 | Supply & fix in replacmentfans ceiling having copper winding motor ,complete with remote and other accessories 230 V,50 Hz AC ,1200 mm sweep. With service value 6 .00 BEE 5 star rated with BLDC motor ( Brushless direct current motor) complete all as specified and directed. |
| 225 | Ditto but for pedestal fan metal body 500mm sweep 230 volt AC 50 Hz. |
| 226 | Ditto but for wall mounting fan metal body 400mm sweep 230 volt AC 50 Hz. |
| 227 | Supply & fix in replacement exhaust fans heavy duty complete steel body and copper winding fan motor,1400 rpm ,AC single phase 230/ 240 V, 50 Hz AC, of size 300 mm sweep with louver including testing and commissioning complete all as specified and as directed at site . |
| 228 | Supply and fixing in replacement capacitor 2.5/3.15 mfd. . |
| 229 | Supply and fixing in replacement fan blade suiatable for 400mm sweep pedestal fan/ Wall mounting fan. |
| 230 | Supply and fixing in replacement fan blade suiatable for300 mm sweep exhaust fan. |
| 231 | Supply and fixing in replacement ball bearing of size 6201 / 6202 / 6203 NBC suiatable forceiling fan / exhaust fan. |
| 232 | Supply and fixing in replacement rubber bush ( reel type) suiatable for 1200mm/1400mm sweep ceiling fan. |
| 233 | Takingdowntheexisting defectiveLTUGcable fromtrenches / pipes/ poleforfault finding / replacement, all as specified and directed of any size between 10 Sq mm to 50 Sq mm 3.5 core/4 Core. ( Note-Excavationandearth workwill be measuredandpaid seperately under relevant item. ) |
| 234 | All as per item No. 203.00 above but size 120 Sqmm 3.5 core to 240 Sq mm 3.5 core. |
| 235 | Supply and laying ,jointing and testingXLPE insulated extrudedPVC outer sheath and inner sheath galvanized steel armoured cable with aluminium conductor suitable for rated voltage of 1100 Volts grade conforming to IS 7089 (Pt I of 1988) laid in tranches/ pipe/duct/pole complete all as specified and directed size 10 Sqmm 4 core. |
| 236 | All as per item 205 above but size 16 sq mm 4 core. |
| 237 | All as per item 205 above but size 25 sq mm 4 core. |
| 238 | All as per item 205 above but size 50 sq mm 3.5 core. |
| 239 | All as per item 205 above but size 120 Sq mm 3.5 core. |
| 240 | All as per item 205 above but size 240 Sq mm 3.5 core. |
| 241 | Supply & laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm thick over the cable complete all as specified and ditected. |
| 242 | Supply & laying brick for protection of cable sub class \"B\"laid dry flat across the cable with width equal to the length of whole brickscomplete all as specified and ditected. |
| 243 | Labour for boring, holes for inserting of 50/80 mm bore GI pope under the road/hard standing or any other location not less than 1200 mm deeep complete all as specified and ditected. |
| 244 | M & L GI pipe 40 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed. |
| 245 | M & L GI pipe 50 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed. |
| 246 | M & L GI pipe 80 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed. |
| 247 | S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz, 250 Amps with breaking capacity 36 KA adjustable, theremal magnetic release type all as specified and directed. |
| 248 | S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz, 200 Amps with breaking capacity 36 KA adjustable, theremal magnetic release type all as specified and directed. |
| 249 | S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz,125 Amps with breaking capacity 16 KA fixed, theremal magnetic release type all as specified and directed. |
| 250 | S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz,100 Amps with breaking capacity 16 KA fixed, theremal magnetic release type all as specified and directed. |
| 251 | S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz,63 Amps with breaking capacity 16 KA fixed, theremal magnetic release type all as specified and directed. |
| 252 | Taking downu/s street light fitting/flood light of any type and make & capacity. |
| 253 | Supply and fix roadway luminaire LED light fittings of 60 watts and including necessary electric connection with 2.5 Sqmm twin core Copper conductor unarmoured cable, complete all as specified and directed. |
| 254 | All as per item No. 223 above but of 70 watts . |
| 255 | Supply and fix LED Flood light 70 W IP 66 including necessary electric connection with twin core twisted flexible copper conductor cable of suitable size . |
| 256 | All as per item No. 225 above but of 210 watts |
| 257 | M&L for cleaning of all condensor tubes of central/package AC plant by disconnecting the condensor from the system, cleaning by descaling pump of suitable capacity using descaling solution of Make:-MAIC / HIBIRD or Hydrochloric acid 20%, cleaning the system through cooling tower by using descaling solution, cleaning condensor tubes by nylon brushes & mild steel rods of suitable size and necessary pumping set and tools etc complete for smooth and proper functioning of plants of following cap of plant :-(Note:- T&P such as pumps, tube etc & descaling solution etc shall be arranged by the contractor at his own cost.) |
| 258 | 3x 7.5 TR Cap (ICU Plant MH). |
| 259 | 2x 5 TR Cap (Signal centre) |
| 260 | M&L for Cleaning and Servicing of nozzles & motorof cooling tower of central/package AC plants completeof any acapcity, as and when required or directed. |
| 261 | M&L for replacement of Contactors for 3 phase compressor rating-35 Amps and testing completeall as directed. Make-L&T/BCH |
| 262 | M&L for replacement of O/L relay suitable for 35 Amps contactor completeall as directed. Make- L&T, Havells, BCH or equivalent. |
| 263 | M&L for replacement of O/L relay suitable for 25 Amps contactor completeall as directed. Make- L&T, Havells, BCH or equivalent. |
| 264 | S & F in repair Gun metal gate valve, ISI marked complete with iron wheel head,screwed both ends for iron pipe of following sizes complete all as specified and directed |
| 265 | 25 mm bore |
| 266 | 40 mm bore |
| 267 | 50 mm bore |
| 268 | S&F in repair On load change over Switch, 100 Amps, 4 pole, 415 Volts, front operated complete all as directed. |
| 269 | S&F in repair On load change over Switch, 63 Amps, 4 pole, 415 Volts, front operated complete all specified and directed. |
| 270 | M&L for replacement of block bearing of blower fan including balancing of blower fan for package type AC, complete all specified and directed. |
| 271 | M&L for replacement of block bearing of blower fan including balancing of blower fan for Central AC complete all specified and directed. |
| 272 | Dismantling burnt electric motor of capacity 2 HP, 3 phase 415 Volts, 50 cycle from booster/ Blower/ CT fan including cutting burnt coils, cleaning the slots and rewinding with and including super enamelled copper wire of existing size & gauge, re-insulating, two coats varnishing & heating, reassembling and commissioning & testing complete all specified and directed. |
| 273 | M&L for Maintenance of DG set at Danapur and carrying out ‘B’ check and replacement of ‘B’ check kit filters such as Oil filter, by pass filter, fuel filter,CR element and CR plates complete with ‘O’ rings and draining of Engine oil and topping up with the new engine oil complete testing all as specified and directed by the Engr-in-Charge for the following capacity DG sets:-Note :-(i) Engine oil shall be measured and paid separately(ii) Labour & transportation shall be arranged by contractor,quoted rate deemed to be inclusive in the unit rate.Make: KIRLOSKER/ CUMMINS /GREAVES/ GREAVES COTTON/ASIATIC/ RUSTON |
| 274 | 30KVA DG Set |
| 275 | 70KVA DG Set |
| 276 | 82.5 KVA DG Set |
| 277 | 100 KVA DG Set |
| 278 | 110 KVA DG Set |
| 279 | 125 KVA DG Set |
| 280 | 160 KVA DG Set |
| 281 | M&L for Renewal/Replacement of unserviceable batteries with maintenance free batteries of 150 AH, 12V including connecting to DG set complete all as directed. |
| 282 | M&L for Renewal/Replacement of unserviceable batteries with maintenance free batteries of 180 AH, 12V including connecting to DG set complete all specified and directed. |
| 283 | Attending thebreakdown of any capacity/make DG Sets, AMF Panels, by Technician & helper for checking all components and rectifythe fault and give report to concern JE complete all specified and directed. Note :- Spare Parts for rectify the fault is measured and paid seperately. |
| 284 | S&FAutomatic cut off type Battery Charger suitable for 12 V,up to 10 Amp Battery complete all specified and directed. |
| 285 | S&F Automatic cut off type Battery Charger suitable for 24 V, up to 10 Amp Battery complete all specified and directed. |
| 286 | Supply and filling the new engine oil 20W/40 for toping up upto the required level complete all specified and directed |
| 287 | Supply and filling the new engine oil 15W/40 for toping up upto the required level complete all specified and directed. |
| 288 | Drain out the fuel from the fuel tank of DG set of capacity 500 Ltrs and above and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat ofsynthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements complete all specified and directed. |
| 289 | All as per item No. 246 above but upto 500 Ltrs complete all specified and directed. |
| 290 | M&L forInhibitor corrosion (coolant additive concentrate) required for top up (TVS Make) complete all specified and directed |
| 291 | Supply and topping up of acid mixture suitable for lead acid batteries of 12 volts complete all specified and directed. |
| 292 | Supply and topping up of distilled water suitable for lead acid batteries of 12 volts complete all specified and directed. |
| 293 | M&L for lifting the Gen Set above up to 200 KVA after dissconnection complete from cables, Shifting to other place within 25 mtr sourrounding area and making PCC foundation of sizesuitable to existing DG Setwith 1 : 2 : 4 PCC. Including smooth finishing.Shifting the DG Set on newfoundation with all necessary arrangement of Cables Connections, Testing and commissioning complete all as directed by Engr-in-Charge.Notes :- All items & Manpower including Crane for lifting up and placing again on new foundation is included in quoted rates. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail