| 1 | Demolition of cement concrete un- reinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 2 | M&L 75mm thick cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in sub base complete all as specified. |
| 3 | M&L Chequered cement concrete tiles with grey cement & pigment 25cm x 25cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors over and including 15 mm thick cement screed bed in CM 1:6etc complete all as specified and as directed. |
| 4 | M&L 100mm thick cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in sub base complete all as specified. |
| 5 | M&L in repair Providing and laying 80 mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed |
| 6 | M&L in repair Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed |
| 7 | M&L 100mm thick PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in hard standing finished even and smooth without using extra cement including spike rolling to surface or making impression of expanded metal while the concrete is steel green complete all as specified and directed by Engr-in-Charge. |
| 8 | Taking down old cement plaster including ranking out joints, hacking for key, scrubbing down with water etc and rubbish off the premisses complete all as specified and directed. |
| 9 | M&L Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified as directed. |
| 10 | M&L for preparation of new plastered surfaces of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10+E35 sqm over new surfaces. complete all as specified and directed. |
| 11 | M& L preparation of new plastered surface of wall and applyingtwo coat of cement base paint over a coat of white cement primerprimercomplete all as specified and directed |
| 12 | M&L for preparation of old plaster surfaces of wall and applying two coats of cement base paintcomplete all as specified as directed. |
| 13 | Demolition of brick work built in cement mortar or cement lime mortar .complete all as specified and directed at site. |
| 14 | M&L Brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed at site. |
| 15 | Allas per Item above here in above but except bricks complete all as specified and directed at site. |
| 16 | M&L for brickwork with subclass \"B\" bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed at site. |
| 17 | Dismantling chain link fencing of any description complete all as specified and directed by Engineer-in-Charge. |
| 18 | Fixing only chain link M S galvanised fencing (IS-272) mesh as required size complete all as specified and directed. |
| 19 | Supply only chain link MS galvanised fencing, any size or type of minimum dia 3.15 mm or above including line wires, binding wire fixed to any type of standards, rails, straining bolts, etc complete all as specified & directed.Note:-weight of chian link fence shall be decided through BOO. |
| 20 | M&L in repair mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 21 | S&F in repairs Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. |
| 22 | S&F in repair MS Posts and struts in fencing (any size of angle) mm including cutting tops to shapes as directed including driling holes for bolting of MS flat iron in horizontal, vertical & diagnal faces of each pannel to be intertwined with Chain link fencing, and fixed to posts with MS nut bolts and washers ,wind ties for sign board posts and struts, andsimilar work confirming to Fe 290 Gde E-165 complete al as spd and directed. |
| 23 | M&Lpreparation ofnew steel surfaces of any description,over 10cm width or girth and apply two coat of synthetic enamel paint over a coat of red oxidecomplete all as specified and as directed . |
| 24 | M&L plain cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate in surface channels and drains complete all as specified and directed. |
| 25 | Extra for forming fair finished drain or channel up to 30 cm inner girth in cement concrete using extra cement incl forms, moulds, mitred/stopped ends etc.complete all as specified and directed. |
| 26 | Demolition of reinforcement cement concrete ( reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 27 | M&L for PCC (1:4:8) type D-2, (using 40mm graded stone aggregate) as in foundation, mass fillings,sub baseetc. complete all as specified & directed. |
| 28 | M&L for Precast RCC 1: 2:4 type B1(nominal mix ) using 20mm graded stone aggregates as indrain/MH cover slab etc including necessary use and wast of form work complete all as specifide and directed . |
| 29 | S&F 10mm diaTMTbars cut to legth, bent to shape required including cranking bending spirally for hooping for slab for manhole etccomplete all as directed. |
| 30 | S&F 6mm to 8mm diaTMTbars cut to legth, bent to shape required including cranking bending spirally for hooping for slab for manhole etccomplete all as directed. |
| 31 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern, with EWC including p or strap ,seat cover , including connection to trap /drainand to flushingpipe anti syphonage pipe etc complete including making good floorcomplete all as specified as directed. |
| 32 | S&F in repair vitreous chainasquating pan orissa pattern size 580X 440mmwhite with intregal foot rest complete including lime concrete(excl flushing cistern and flush pipe) but connecting to flushing pipe, anti-symphonage pipe etc complete all as specified as directed. |
| 33 | S&F in repair vitreous china urinal half stall type white complete including providing and fixing plugs,etc all fittings including spreader (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)complete all as specified and directed. |
| 34 | Taking downeaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) |
| 35 | S&F for 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or laid in trenches as in floors, all as specified &directed . |
| 36 | S&F for 110mm bore PVC (SWR) bendsprovided with access door jointed with solvent cement joint all as specified &directed . |
| 37 | S&F for 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or laid in trenches as in floors, all as specified &directed . |
| 38 | S&F for 75mm bore PVC (SWR) bendsprovided with access door jointed with solvent cement joint all as specified &directed . |
| 39 | S&F in repair PVC (SWR) P or S trap 125/110 mm,setting and jointing with solvent cement complete all specified and directed. |
| 40 | M&L in repair 75mm dia PVC (SWR) floortrap, plane with grating including jointing with solvent cement complete all specified and directed. |
| 41 | Excavation in trenches n.exc 1.5M wide and n.exc 1.5M depth and n.exc 10 Sqm on plan and getting out in any type of soil (for manholes and sewage lines, drain etc.) .complete all as specified and directed at site. |
| 42 | Returning filling in including spreading watering and well raming in layer . Exc 25 cm each in loose/soft soil complete all as specified and directed. |
| 43 | Removing excavated material to a distancenot exc50 m and depositing where directed, complete all as specified and directed |
| 44 | M&L forCutting into existing manholes for connecting new drains and making good to pipe and rendering cutting out existing bending for and forming branch channel incement concrete 1:2:4 type B1 smooth finished and reforming benching as required for pipe 150mm bore complete all as specified and directed. |
| 45 | Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 200 mm dia for all depth complete all as specified and directed |
| 46 | Material and labour for Cleaning/removal of blockage from bathroom,EWC/IWC (any type), kitchen, WHB and urinals including connected Nahani traps / gully traps/floor traps, grating of trap, waste pipes, pipe in any length upto first manhole etc choked with mud / other accumulated sludge and getting out, washing thoroughly at any location, at any floor by rodding/choke remover/Pressure technique/manually or otherwise to clear blockage upto entire satisfaction of users,including refixing of oval assess door covers with new nuts & washers and refixing manhole covers, including removing of all wastes, solid or liquid sludge and depositing the sludge in a pit (at empty/open area) of suitable size at a distance exceeding 50 metres from the building where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified andas directed .(a) Contractor must employ Minimum 3 Nos labourers daily deployed i.e. 1 No in Vijay vihar, 01 No in GRD and 1 No for NCC area, complete all as specified and as directed . (b)Contractor or his representative shall report daily at 09.00 AM except on Sunday/ National holidays in the office of Engineer-in-Charge/ Complaint cell to receive complaint slip and necessary directions. Complaints received through telephonic message from JE/ Engineer-in-Charge shall also be attended on the same day and the completion of work shall be reported by 05.00 PM of every working day to JE/ Engineer-in-Charge. (c) In case of non attedence of complaints against BOQ item 64 above by the contractor on the same day, a penalty of Rs 200/- per complaint per day and for complaints against BOQ item 63 above, a penalty of Rs 100/- per complaint per day will be recovered from the contractor due complete all as specified and as directed . (d) The cost for all necessary T&P such as green female bamboo strips, iron rods, sewage rodding machine, buckets, rope, ladder, safety mask, bleaching powder etc and all other other materials for execution of the work shall be included in the unit rate complete all as specified and as directed . (e) A complaint register shall be maintained by JE and proper record of complaints received and attended with date and time shall be recorded and shall be signed daily by both the parties. Complaint register shall be kept on record of Engineer-in-Charge after completion of work complete all as specified and as directed . |
| 47 | Cleaning of Manhole n. exc 1.50m deep including bailing out water, from it and removing sludge and blockages from inlet and outlet of sewer lines including taking out the excavated sludge and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the septic tank including site clearance to a distance of 3 Metre around septic tank complete all as specified and directed for the following capacity :- (a) ForManhole n. exc 1.50m deep. |
| 48 | ditto as above but for manholeexc 1.50m but n.exc 3m deep….ditto…. |
| 49 | ditto as above but for septic tank of 25 to 50 user capacity.….ditto…. |
| 50 | Dewatering of septic tank, sump wells, grease trap including bailing out water with mechanical device like super sucker machine, high pressure jetting machine, from it and removing sludge and blockages from inlet and outlet of sewer lines including taking out the excavated sludge and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the same including site clearance to a distance of 3 metre aroundcomplete all as specified and directed. |
| 51 | Cleaning of soil pipe lines of any type of 100mm dia by roding from man hole to man hole cleaning eyes and flushing with water for the cleaning incl removal of sludge and re-setting of man holes cover complete. |
| 52 | Ditto all as per item above but for 150mm dia pipe…ditto… |
| 53 | Ditto all as per item above but for 200mm dia pipe….ditto… |
| 54 | M&L for 75 mm thick PCC 1:3:6 type C-2, using 40mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement concrete surface even and smooth including forming construction joint 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixturecomplete all as specified and as directed |
| 55 | Dismantling of structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed. |
| 56 | M&L for Framed work as in doors or gates or grating of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing Fe 410 -W (Gde E- 250) complete complete all as specified and as directed. |
| 57 | Dismantling brick or brick tiles laid bedded and pointed in any type of mortar etc complete all as specified and directed |
| 58 | M&L bricks, sub class B, laid flat,bedded and jointed in CM 1:6 and pointed in CM 1:3in drain, old size bricks complete all as specified and directed at site. |
| 59 | Labour only forbricks, sub class B, laid flat,bedded and jointed in CM 1:6 and pointed in CM 1:3in drain, old size bricks complete but except bricks ( only serviceable Brick obtained from dismantling complete all as specified and directed at site. |
| 60 | M&L bricks, sub class B, laid on edge,bedded and jointed in CM 1:6 and pointed in CM 1:3in drain, old size bricks complete all as specified and directed at site. |
| 61 | Labour only for brick work , sub class B, laid on edge,bedded and jointed in CM 1:6 and pointed in CM 1:3in drain, old size bricks completebut except bricks( only serviceable Brick obtained from dismantling) complete all as specified and directed at site. |
| 62 | M&L for providing cement concrete 1:2:4 type B0 using (12.5mm graded aggregate) as in copings using necessary use and waste of formwork complete all as specified and directed. |
| 63 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground post embeded in cement concrete. |
| 64 | M&L PCC 1:3:6 type C2 40mm graded stoneaggregate as in fixing of fencing post and mass concrete all as specified. |
| 65 | Dismantling of concertina coil 600mm dia any shape including razor wire of six linc etc all as specified and directed. Note :- Concertina coil and six link razor wire shall be measured as one Rm |
| 66 | S&F in 600mm dia punchedtape concertina coil (effective dia 550mm at strech length of coil 6m) with two handle and spikes at both end of coil with dovetail clips [18 SWG], incl razor wire [7 No], 6m length of each wire medium size, barbed length 20mm width 14mm, incl 51 pins, 128 nos of clips in each coil incl 230gm/ Sqm Zinc coating on core wire complete all as specified.Note :- Concertina coil and six link razor wire shall be measured as one Rm |
| 67 | Fixing only existing serveciable concertina coil and razor bladecomplete all as specified and diected.Note :- Concertina coil and six link razor wire shall be measured as one Rm |
| 68 | Fixing only existing serveciable concertina coil and razor bladecomplete all as specified and diected |