| 1 | Comprehensive repair/maintenance of storage type electric water heater (geyser) of capacity 50 litres, vertical or horizontal type comprising of the following:(a) Opening or dismantling the storage tank, taking down, de-scaling, brushing and thoroughly cleaning.(b) checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc. in situ to ensure proper functioning of parts including supply and replacing of washers/ gasket nut bolts etc.(c)Checking and rectify earth continuity of the Electrical circuits of Geyser and power point.(d)Checking and re-fixing thermostat and re-adjusting the same.(e) De-scaling the immersion type heating element and siphon assembly with diluted Hydrochloric acid or clear pedette solution.(f)Checking of indicator lamp for its proper serviceability. (g) Re-assembling the Geyser and re-install at same position and testing complete all as specified and directed.NOTE: Unserviceable Parts/ components of electric water heater shall be replaced by the contractor. Under Supply of new parts/components which shall be measured and paid separately under respective item of schedule. |
| 2 | Ditto all as per item no 1.00 above but for geysers of capacity 25 litres. |
| 3 | S&F bib taps 15mm bore, half/quarter turn, fancy type, long body, cast copper alloy, chromium plated, screwed for iron pipe or for brass ferrule including all accessories complete all as specified and directed. |
| 4 | S&F in repair 15mm bore Steel water tubing \"medium grade\", galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floors complete all as specified and directed.Make- Tata/Jindal /Prakash surya. |
| 5 | S&F in repair MCB, single pole & neutral 20-32 Amp, 240 volts, 10 KA breaking capacity, \"C\" curve complete all as specified and directed. Make- Havells/Legrand/ABB/Indoasian/ L&T/ C&S. |
| 6 | Supply only thermostat of Type EST 11/20A, 240 Volt of ISI marked approved make complete all as specified and directed.Make- Theta/Bajaj/ V-guard. |
| 7 | Supply only thermostat of Type EST 7/15A, 240 Volt of ISI marked approved make complete all as specified and directed.Make- Theta/Bajaj/ V-guard. |
| 8 | Supply only heating element of capacity 2 KW, AC 240 volts, suitable for storage type electric water heater as per requirement (press type/ screw type/ triangular/ circular base or ceramic cartrige type), ISI marked complete all as specified and directed.Make- Bajaj/ V-guard/ Havells/ Crombton. |
| 9 | Supply only heating element of capacity 1.5 KW, AC 240 volts, suitable for storage type electric water heater as per requirement (press type/ screw type/ triangular/ circular base or ceramic cartrige type), ISI marked complete all as specified and directed.Make- Bajaj/ V-guard/ Havells/ Crombton. |
| 10 | Supply only copper syphon (door) assembly suitable for geyser of capacity 50 litres of any type as required complete with inlet and outlet and provision for thermostat pipe with drain pipes with drain plug, screws, studs, clamps for fixing heating elements etc. including gasket complete all as specified anddirected. |
| 11 | Supply only copper syphon (door) assembly suitable for geyser of capacity 25 litres of any type as required complete with inlet and outlet and provision for thermostat pipe with drain pipes with drain plug, screws, studs, clamps for fixing heating elements etc. including gasket complete all as specified anddirected. |
| 12 | Supply only polycorbonate 3-pin, 16 amps Plug top, white complete all as specified and directed. Make- Havells/Anchor/Legrand/ L&T/C&S. |
| 13 | Supply only PVC insulated PVC sheathed flexible round stranded copper wire of size 2.5 sqmm, 3 core complete all as specified and directed. |
| 14 | Supply only indicating LED lamp, Neon type, 240 volt AC suitable for 25/50 ltrs capacity geysers complete all as specified and directed. |
| 15 | Supply only safety valve suitable for 25/50 litres capacity geyser complete all as specified and directed. |
| 16 | S&F in repair sheet metal enclosures, single pole with socket plug top and MCBs with a two pin and earth plug and socketwith one single pole MCB 20 Amps complete all as specified and directed. |
| 17 | S&F in repair Modular type AC boxwith socket plug top and MCBs withtwo pin and one pin forearth plug and socket with one single pole MCB 20 Amp complete all as specified and directed. |
| 18 | M&L for tracing and arresting of leakage in storage tank of 25 ltrs capacity geyser by brazing and soldering at leakage point and testing on completion complete all as specified and directed. |
| 19 | M&L for tracing and arresting of leakage in storage tank of 50 ltrs capacity geyser by brazing and soldering at leakage point and testing on completion complete all as specified and directed. |
| 20 | M&L for spray painting to 50 litres capacity geysers with one coat of synthetic enamel paint of approved tint includingpreparation of old steel surface and writing of serial/ MES no. with black colour synthetic enamel paint (height of letters not exc 2cm) including taking down of geyser and refixing in the same position after completion of painting work and making inlet/ outlet water connection and testing complete all as specified and directed. |
| 21 | M&L for spray painting to 25 litres capacity geysers with one coat of synthetic enamel paint of approved tint includingpreparation of old steel surface and writing of serial/ MES no. with black colour synthetic enamel paint (height of letters not exc 2cm) including taking down of geyser and refixing in the same position after completion of painting work and making inlet/ outlet water connection and testing complete all as specified and directed. |
| 22 | S&F in repair 450mm long PVC connection with brass adopter nut suitable for 15mm bore pipe complete all as specified and directed. |
| 23 | S&F in repair 600mm long PVC connection with brass adopter nut suitable for 15mm bore pipe complete all as specified and directed. |
| 24 | S&F in repair 450mm long steel hose connection with brass adopter nut suitable for 15mm bore pipe and suitable for hot water complete all as specified and directed. |
| 25 | S&F in repair 600mm long steel hose connection with brass adopter nut suitable for 15mm bore pipe and suitable for hot water complete all as specified and directed. |
| 26 | S&F in repair non return valve of cast copper alloy suitable for 15mm bore pipe complete all as specified and directed. |
| 27 | S&F in replacement stainless steel inner tank of capacity 25 litres geyser, vertical or horizontal type of any make complete all as specified and directed. |
| 28 | S&F in repair metallic plug top suitabe for sheet metal enclsoure 20 Amp capacity complete all as specified and directed. |
| 29 | S&F in repair base socket metallic suitable for sheet metalenclsoure 20 Amp capacity complete all as specified and directed. |
| 30 | S&F in repair switch socket combination, flush type, single pole, multipurpose 2 in 1, 5 pin 5 and 15 Amp, 230 volts complete all as specified and directed. Make- Anchor/Havells/ Legrand/L&T/ C&S. |
| 31 | S&F in replacement instant type geyser 3 ltrs capacity with stainless steel inner tank, electric driven, single phase, AC 230 volt, rust and shock proof ABS outer body for long life including connecting water supply pipe with fitting as required at sitecomplete all as specified and directed. Make: Havell\"s /Bajaj/Crompton/RacoldNOTE: Old geyser shall be deposited at E/M store yard. |
| 32 | S&F in replacement storage type water heater (geyser) of capacity 25 litres, electric driven, BEE five star rated, mild steel inner tank, AC 230 volt, vertical type and provn of fixing arrangement with 4Nos fastener of size 100x10 mm with washer and bolts and making water connection with 02 nos 450mm long flexible pipe and 16 Amp plug top complete all as specified and directed. Make: Havell\"s /Bajaj/Crompton/RacoldNOTE: Old geyser shall be deposited at E/M store yard. |
| 33 | Supply and fix in repair geyser fastner 4 to 6 \" steel complete with all accessories all as specified and directed. |
| 34 | M&L for glass wool in any type of geyser complete all as specified and directed. |
| 35 | Checking of ceiling fan 1200/1400mm sweep at site in existing position as per requirement based on MES complaint slip on daily basis except sunday/ holidays and provn of S&F of 2.5 mfd condensor of ceiling fan at site in position as in repair complete all as specified and directed. |
| 36 | Checking of exhaust fan of any size/type at site in existing position as per requirement based on MES complaint slip on daily basis except sunday/ holidays and provn of S&F of 2.5 mfd condensor of ceiling fan at site in position as in repair complete all as specified and directed. |
| 37 | Taking down carefully ceiling fan of any sweep and make after disconnecting all electrical connection, detaching the blades, removing fan with blades to workshop, opening and cleaning of fan, segregation of unserviceable parts, replacement of unserviceable spares parts with new parts including necessary machining work and lubricating with approved grade of grease and necessary minor soldering work (if required) and re-assembling the fan complete and testing and refixing the fan in same position including all electrical connection and provn of replacement of two nos split pins, one connection block and one rubber reel complete all as specified and as directed.NOTE: (i) Rewinding work of armature (if any) shall be measured and paid separately under relevant item of Sch \"A\" given here-in-after.(ii) Replacement of new spare parts with old unserviceable parts other than connector, split pins, connection block and rubber reel and same shall be measured and paid separately under respective item of schedule \"A\" given here-in-after.(iii) Labour cost for replacement of spare parts shall deemed to be inclusive in quoted unit rate.(iv) The fan repair work will be done in AGE E/M Yard only. |
| 38 | M&L for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for fan of size 1200/ 1400mm sweep with new super enamelled copper wire of existing gauge including provn of necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing complete all as specified and directed.Note: The ceiling fan winding work will be done in AGE E/M Yard only. |
| 39 | S&F in replacement onlyceiling fan motor copper winding with super enamelled copper wire of 1200/1400 mm sweep complete all as specified and directed |
| 40 | Supply and fixing ceiling fan completewith blade down rodand accessories 230 V,1400 mm sweep air delivery 245 cfmcomplete with brusheless direct current motors all as specified and directed .Make :- Havells/Philips/Bajaj / Usha. |
| 41 | Taking down carefullyfan of any size/sweep exhaust fan, wall fan, cabin fan and fresh air fan after disconnecting all electrical connection, detaching the blades, removing fan with blades to workshop, opening and cleaning of fan, segregation of unserviceable parts, replacement of unserviceable spares parts with new parts including necessary machining work and lubricating with approved grade of grease and necessary minor soldering work (if required) and re-assembling the fan complete and testing and refixing the fan in same position including all electrical connection and provn of replacement of two nos split pins, one connection block and one rubber reel complete all as specified and as directed.NOTE: (i) Rewinding work of armature (if any) shall be measured and paid separately under relevant item of Sch \"A\" given here-in-after.(ii) Replacement of new spare parts with old unserviceable parts other than connector, split pins, connection block and rubber reel and same shall be measured and paid separately under respective item of schedule \"A\" given here-in-after. (iii) Labour cost for replacement of spare parts shall deemed to be inclusive in quoted unit rate.(iv) Repair workof exhaust/wall/cabinfans wili be done in AGE E/M Yard only. |
| 42 | M&L for taking out and removing burnt copper winding, cleaning the armature, rewinding the armature of exhaust fan of size 300mm sweep with new super enamelled copper wire of existing gauge including provn of necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing complete all as specified and directed.Note: The exhaust fan winding work will be done in AGE E/M Yard only. |
| 43 | Ditto all as per item no 42 above but for exhaust fan of size 200/250mm sweep. |
| 44 | Ditto all as per item no 42 above but for exhaust fan of size 400/450mm sweep. |
| 45 | Ditto all as per item no 42 above but for PVC body exhaust fan of size 250/300mm sweep. |
| 46 | Ditto all as per item no 42 above but for PVC body exhaust fan of size 200mm sweep. |
| 47 | Ditto taking out and removing burnt copper winding, cleaning the armature and M&L for rewinding the armatureof wall mounted cabin fan of size 300/400mm sweep with new super enamelled copper wire of existing gauge including provn of necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing complete all as specified and directed. |
| 48 | M&L for spray painting ceiling fan of any sweep with one coat of synthetic enamel paint of approved tint includingpreparation of old steel surface and filling cavaties with filler materials and writing of serial/ MES no. with black colour synthetic enamel paint (height of letters not exc 2cm) including taking down of fan and refixing in the same position after completion of painting work and making inlet/ outlet water connection and testing complete all as specified and directed. |
| 49 | Ditto all as per item no 48 above but for exhaust fan of any size any sweep complete all as specified and directed. |
| 50 | S&F in repair ceiling fan regulator, electronic, rotary step up socket type, 230 volts suitable for 1200/1400 mm sweep ceiling fan including necessary connection complete all as specified and directed. |
| 51 | S&F in repair ceiling fan regulator, electronic, rotary step up switch type, 230 volts suitable for 1200/1400 mm sweep ceiling fan including necessary connection complete all as specified and directed. |
| 52 | S&F in repair ceiling fan regulator modular type, electronic, rotary step up switch type, 230 volts suitable for 1200/1400 mm sweep ceiling fan including necessary connection complete all as specified and directed. |
| 53 | M&L for flexible multi stranded copper wire twin twisted two core of size 0.75sqmm complete all as specified and directed. |
| 54 | Supply only new metal bush made out of Gun metal/ Brass of same size suitable for ceiling fan, wall mounted fan and exhaust fan complete all as specified and directed. |
| 55 | Supply only roter shaft of ceiling fan, exhaust fan, wall fan of any capacity, make and type complete all as specified and directed. |
| 56 | Supply only ball bearings No. 6201 and 6202 suitable for fan complete all as specified and directed. |
| 57 | Supply only ball bearings No. 6203 and 6204 suitable for fan complete all as specified and directed. |
| 58 | Supply onlycapacitor 1.5 Mfd, 400Volts, 50Hz complete all as specified and directed. |
| 59 | Supply onlycapacitor 2.5 Mfd, 400Volts, 50Hz complete all as specified and directed. |
| 60 | S&F in replacement of plastic body exhaust fan of size 250mm complete all as specified and directed. Make - Bajaj/Havells/Phillips/ Crompton. |
| 61 | S&F in replacement of plastic body exhaust fan of size 200mm complete all as specified and directed. Make - Bajaj/Havells/Phillips/ Crompton. |
| 62 | S&F in replacment of cabin fan of size 300mm sweep, opal white, 250 Voltcomplete all as specified and directed. Make - Bajaj/Havells/Phillips/ Crompton. |
| 63 | S&F in replacment of cabin fan of size 400mm sweep, opal white, 250 Voltcomplete all as specified and directed.Make - Bajaj/Havells/Phillips / Crompton. |
| 64 | S&F of exhaust fan super enamelled copper winding, single phase, 230/240 Volt heavy duty of size 230/250 mm sweep 1400 RPM,including suitable louvers and making connection with twisted copper flexible wire 23/0.076mm all as specified and directed. Make - Bajaj/Havells/Phillips/ Crompton. Note:- Old exhaust fan shall be deposited in AGE E/M yard |
| 65 | S&F of exhaust fan super enamelled copper winding, single phase, 230/240 Volt heavy duty of size 300 mm sweep 1400 RPM,including suitable louvers and making connection with twisted copper flexible wire 23/0.076mm all as specified and directed.Make - Bajaj/Havells/Phillips / Crompton. Note:- Old exhaust fan shall be deposited in AGE E/M yard |
| 66 | S&F of exhaust fan super enamelled copper winding, single phase, 230/240 Volt heavy duty of size 450 mm sweep 1400 RPM,including suitable louvers and making connection with twisted copper flexible wire 23/0.076mm all as specified and directed. Note:- Old exhaust fan shall be deposited in AGE E/M yard .Make - Bajaj/Havells/Phillips / Crompton. |
| 67 | S&F in repairblade set of metallicexhaust fan of size 450mm sweep with frame, four legs and coupling complete all as specified and directed. |
| 68 | S&F in repair blade set of metallic exhaust fan of size 300mm sweep with frame, four legs and coupling complete all as specified and directed. |
| 69 | S&F in repair blade set of metallicexhaust fan of size 200/250 mm sweep with frame, four legs and coupling complete all as specified and directed. |
| 70 | S&F in repair blade set of cabin fan of size 400mm sweep with frame, four legs and coupling complete all as specified and directed. |
| 71 | S&F aluminium blade set (set of three) suitable for 1200mm sweep ceiling fan of any type and make complete all as specified and directed. |
| 72 | S&F aluminium blade set (set of three) suitable for 1400mm sweep ceiling fan of any type and make complete all as specified and directed. |
| 73 | S&F in replacement down rod 0.60m long made out of 15mm bore GI tubing, medium grade, with both side hole/slot for fixing of ceiling fan complete all as specified asdirected. Make:- TATA/ JINDAL/Prakash Surya. |
| 74 | S&F in replacement down rod 1.00m long made out of 15mm bore GI tubing, medium grade, with both side hole/slot for fixing of ceiling fan complete all as specified asdirected. Make:- TATA/ JINDAL/Prakash Surya. |
| 75 | S&F in replacement down rod 1.25m long made out of 15mm bore GI tubing, medium grade, with both side hole/slot for fixing of ceiling fan complete all as specified asdirected. Make:- TATA/ JINDAL/Prakash Surya. |
| 76 | S&F in replacement down rod 1.75m long made out of 15mm bore GI tubing, medium grade, with both side hole/slot for fixing of ceiling fan complete all as specified asdirected. Make:- TATA/ JINDAL/Prakash Surya. |
| 77 | S&F in replacement hanging clamp with GI hook suitable for fixing on ceiling fan down rod, made out of 40x5mm GI strip, of any type, with rubber reel, split pin, bolts, nut and washer complete all as specified and directed. |
| 78 | S&Finreplacement PVC gang box fitted with and including piano type switch 15 A and socket 15 A, 230 Volts complete with pvc gitties and screws complete all as specified and directed. |
| 79 | M & L for making opening of holes circular/square in brick wall 230/460mm thick built in cement mortar and making good surface with cement mortar 1:3 including all necessary nuts, bolts, washers etc complete all as specified and directed. |
| 80 | Takingdown old unserviceablemainswitches/DB’s up to 100 Amps capacity fixed in wall and making good of all disturbed surfaces as perexisting complete all as specified and directed. |
| 81 | S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 4 way, AC,240 volt with 200 Amp bus bar rating complete all as directed. Make-Havells/Legrand/Seimens/L&T/C&S. |
| 82 | S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 8 way, AC,240 volt with 200 amp bus bar ratingcomplete all as directed.Make-Havells/Legrand/Seimens/L&T/C&S. |
| 83 | S&Fsheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 12 way, AC,240 volt with 200 Amp bus bar rating complete all as directed.Make-Havells/Legrand/Seimens/L&T/C&S. |
| 84 | S&Fsheet metal enclosure double door (MCB DB) three phase and neutral with 200 Amps rated bus bar TPN,4 wayverticall type, with provision of MCB incommer, AC, 415 Voltcomplete all as specified & directed.Make-Havells/Legrand/Seimens/L&T/C&S. |
| 85 | S&Fsheet metal enclosure double door (MCCB DB) three phase and neutral with 200 Amps rated bus bar VTPN,4 way vertical type, with provision of MCCB incommer, AC, 415 Voltcomplete all as specified & directed.Make-Havells/Legrand/Seimens/L&T/C&S. |
| 86 | M & L industrial socket 5 pin, 3P+E 240V, AC of rating 32 Ampswith industrial plug top complete with triple pole MCB and all fixing accessoriesall as specified & directed.Make - Legrand/ Crompton / ABB or equivalent. |
| 87 | M & L industrial socket 3 pin, 2P+E 240V, AC of rating 20 Ampswith industrial plug top complete with double pole MCB and all fixing accessoriesall as specified & directed. Make - Legrand/ Crompton / ABB or equivalent. |
| 88 | S&F MCBsingle pole, 6 to 32Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed.Make-Havells/Legrand/Seimens/L&T/C&S. |
| 89 | S&FMCBsingle pole, 32 to 40 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed.Make-Havells/Legrand/Seimens/L&T/C&S. |
| 90 | S&F MCB DP 40 to 63 Amps 240 Volts, 50 Hz, 10 KA breaking capacity complete all as directed.Make-Havells/Legrand/Seimens/L&T/C&S. |
| 91 | S&F MCB Four Pole 40 to 63 Amps 415 Volts, 50 Hz, 10 KA breaking capacity complete all as directed.Make-Havells/Legrand/Seimens/L&T/C&S. |
| 92 | S&FMCB Four Pole 100 Amps 415 Volts, 50 Hz, 10 KA breaking capacity complete all as directed.Make-Havells/Legrand/Seimens/L&T/C&S. |
| 93 | S&F MCCB 4 pole 100 / 125 Amp 415 volts 50 HZ25 KA breakingcapacity complete all as directed.Make-Havells/Legrand/Seimens/L&T/C&S. |
| 94 | Material, labour (Technician & Helper) and T&P including testing eqptsfor carring outs comprehensive maintenance and testing of earthing any type as per existing procedure for lighting protection /eqpts/domestic etc in tech area & admin area by tightening of nut bolts arranging earth lead in allighnment mannerreplacing unservicable earthing lead ,funnel ,pit coverand PCC pits etc and testing of earthing and recording result in register as per procedure provided as directed ,If result found more than permissible limit (e.i more than 2 ohm). reconditioning of earthing carried out by pouring water with salt /chemical as per direction and further testing the same earthing result and recordsing in register including levelling refilling of earth settle down near pit complete all as specified and directed.Note-(i) Necessary compound required for recharging shall deemed to included in quoted unit rate.(ii) During AMC of earthing , if any parts of the earthing is required to be replaced the same will be done by the contractyor as per directed by EIC . The cost of such parts shall deemed to be included in the unit rate quoted by th contractor for AMC.(iii) Pouring of salt/chemical/charcoal water in the earth pit is included in the rate quoted.(iv) Total no of earthing to be checked during month shall be 100-130 nos |
| 95 | S&F Submain wiring with two single core PVCinsulated FRLS-H multistrand copper conductor cable of size 10Sq mmdrawn into and including non metallic heavy duty rigid concealedPVCcondute not less than 25mm size ISI markedwith allfittings / accessories and 10Sq mm FRLS-H multistrand copper conductorcable as continuous earth wire complete al as specified and directed.Make-Polycab/Plaza/Finolex/RR Cables/ Havells. (Note :- for submain wiring: Two run of single core cable and one run of earth wire will be measured as one lengthandconduit and its accessoriesis deemed to be included in the unit rate quoted for this items.) |
| 96 | S&F Submain wiring with two single core PVCinsulated FRLS-H multistrand copper conductor cable of size 04 Sq mmdrawn into and including non metallic medium duty rigid concealedPVCcondute not less than 25mm size ISI markedwith allfittings / accessories and 04 Sq mm FRLS-H multistrand copper conductorcable as continuous earth wire complete all as specified and directed. Make-Polycab/Plaza/Finolex/RR Cables/ Havells (Note :- for submain wiring: Two run of single core cable and one run of earth wire will be measured as one lengthandconduit and its accessoriesis deemed to be included in the unit rate quoted for this items.) |