| Sl. No. | Item Description |
| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 2 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 4 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below |
| 5 | Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge:Up to 150 mm diameter |
| 6 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 7 | Dismantling aluminium/ Gypsum/ Wooden partitions/ Venetian Blind, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 8 | Dismantling of Central Air Condition Duct (1000mm X 450mm) from Corridor, cutting the das fastener and making the slab surface good by cement plaster and disposal of the same as directed by the Engineer-in-charge. |
| 9 | Dismatling of PVC sheet from IPS floor (without damaging the floor), skirting and removing the adhesive from the floor by scrapping using Scotch bite and sand paper and cleaning the floor throughly by soap water or as directed by the Engineer-in-Charge. |
| 10 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 11 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 12 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 13 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 14 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 15 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 16 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 20 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7) |
| 17 | 20 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand) |
| 18 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 19 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 20 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour: New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre |
| 21 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 22 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 24 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 25 | Providing & fixing G.I pipes complete with G.I fittings and clamps, including cutting and making good the walls etc. 15mm dia nomonal bore |
| 26 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore |
| 27 | Providing and fixing uplasticised PVC connection pipe with brass unions :30 cm length:15 mm nominal bore |
| 28 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :15 mm nominal bore |
| 29 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore |
| 30 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :15 mm diameter pipe |
| 31 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe.40 mm dia |
| 32 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms |
| 33 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board. 510x1040 mm bowl depth 250 mm |
| 34 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including C971 painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink without drain board. 610x510 mm bowl depth 200 mm |
| 35 | Providing and fixing vertical venetian blind of approved make ( Mac/Vista) |
| 36 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble. Area of slab over 0.50 sqm |
| 37 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 38 | Applying priming coat:With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood |
| 39 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 40 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC \"C\" channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading. on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the \"C\" Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer\"s specification & drawing. 30 mm thick plain PVC door shutters |
| 41 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimensionin higher side shall be accepted but no extra payment on this accountshall be made.Note: For uPVC frame, sash and mullion extruded profiles minus 5%tolerancein dimension i.e. in depth & width of profile shall be acceptable.Casement window single panel with S.S. friction hinges(300 x 19 x 1.9 mm), made of (small series) frame 47 x 50mm & sash 47 x 68 mm both having wall thickness of 1.9 ±0.2 mm and single glass pane glazing bead of appropriatedimension. (Area of window upto 0.75 sqm.) |
| 42 | Providingandfixingscaffolding system onthe exteriorside,up tofive storyheightmade with Bamboo centre to centre horizontal & verticaljoining with coir rope and also providing workingplatformetc.and maintainingitinaserviceableconditionfortherequiredduration as approvedand removingitthere after.The scaffolding systemshallbe stiffenedwithbracings,runners,connectionwiththebuildingetc whereverrequiredforinspectionofworkatrequiredlocationswith essentialsafetyfeaturesforthe workmenetc.completeasper directionsandapprovalofEngineer-in-charge .Theelevationalareaof thescaffolding shall bemeasuredforpaymentpurpose.Thepayment will be made once irrespective of duration of scaffolding. |
| 43 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type orof approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge. 50 mm average thickness |
| 44 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust freesteel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. |
| 45 | Removing corroded worn out portion of reinforcement (when the area of bar is damaged by more than 25%) by cutting and replacing the same by a new plain round bar of requisite diameter by binding with required lap / welding with old bar, including cost of reinforcement, complete in all respect including removing unserviceable materials from site as per direction of the Engineer - in - charge. Note : Payment on weight (Kg.) of new reinforcement. |
| 46 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as perspecifications and direction of EngineerIn-charge complete in all respect. Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make. |
| 47 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100 mm upto 200 mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/ balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. Upto and including 12 mm dia. |
| 48 | Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of “L” shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge. |
| 49 | Providing, mixing and applying SBR polymer (of approved make @ minimum 2% by wt. of cement used) modified plain/reinforced cement concrete for structural members having minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] with specified average thickness. Note: Rates shall be for finished surface area of concrete and shall include the cost of labour, concrete and appropriate approved Super-Plasticiser for rendering concrete as flowable and SBR polymer but shall exclude cost of reinforcement, bond coat, Shear Keys, centering and shuttering, strutting, propping etc (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument).50 mm thick in Grade M25 with cement content not less than 330 kg per cum. |
| 50 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 51 | Taking out of 01 (one) no wall hanging rack of size 3050 (L) X 300 (B) X 600(H), 2Nos of size 1552 (L) X 300 (B) X 600(H) and 1No of size 1220 (L) X 300 (B) X 600(H)from Room No.134 and refixing the same in Room No.136 with necessary repair such as 6 mm century ply, and necessary accesaries like Screw, Nail, etc. finishing in all respect all complete as directed by Engg in charge at CSIR-IICB, Jadavpur Campus, Kolkata - 700032. |
| 52 | Construction of wooden panelling on wall of Director\"s Room having wall size (a) 2.78m (L)X 3.35m(H), (b) 4.80m (L)X 3.35m(H), (c) 7.58m (L)X 3.35m(H), (d) 7.45m (L)X 3.35m(H), (e) 2.80m (L)X 3.35m(H), (f) 4.35m (L)X 3.35m(H) consisting of Sal wood frame work of size 2\"X 1\"(spacing of frame @ 600mm C/C both in vertical and Horizontal direction of wall), 12mm Century Ply, 4mm teak Veneer and polishing the wood work and wooden door (new & old) in all respect as per direction of Engineer-in-Charge. |
| 53 | Providing, fitting & fixing Laminate timber flooring having colour: natural beige, good abrasion resistence, Dimensions: 1220MM x 200MM, Thickness: 8.3MM, locking: ARC CLICK GERMAN TECHNOLOGY, medium emboss surface finish and consisting of door profile and locking bid etc all complete as per direction of Engineer-in-charge. |
| 54 | Providing, fitting & fixing uPVC French Window having material: High-grade UPVC with internal steel-reinforce, finish: White / Woodgrain / Custom RAL colors, Thermal Insulation: U‑value ≤ 1.6 W/m²K, Sound Insulation: Up to 35 dB with, Glass Options:5 mm (transparent) Weather Resistance: Wind class C5, Water tightness 600 Pa, Opening Style: French casement (inward/outward opening) with handle etc,all complete as per direction of Engineer-in-charge. |
| 55 | Shifiting of materials (furnitures)from the laboratory to some suitable place and again rearranging the material to the concerned room after renovation (Civil, Electrical and Air Condition) at CSIR-IICB, Jadavpur and Salt lake campus, Kolkata. |
| 56 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/ 250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick |
| 57 | Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. |
| 58 | Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete :With residual type petroleum bitumen of grade VG - 10 |
| 59 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 60 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5°.110 mm bend |
| 61 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain). 110 mm Shoe |
| 62 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 63 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 64 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc. as required. |
| 65 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 66 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. |
| 67 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 68 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 69 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 70 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 71 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. |
| 72 | 3X1.5 sq.mm. |
| 73 | 3X2.5 sq.mm. |
| 74 | 3X4 sq.mm. |
| 75 | 3X6 sq.mm. |
| 76 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 77 | 20 mm |
| 78 | 25 mm |
| 79 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 80 | 2 Pair |
| 81 | Supply of following sizes of 1.1 kV grade multicore aluminium conductor XLPE sheathed armoured cable as per IS 7098 (Part -1) 1988. |
| 82 | 3 Core 16 Sq. mm. |
| 83 | 4 Core 25 Sq. mm. |
| 84 | 4Core 35 Sq. mm. |
| 85 | 4Core 70 Sq. mm. |
| 86 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
| 87 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 88 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25X3mm MS flat clamp). |
| 89 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 90 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 91 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25X3mm MS flat clamp). |
| 92 | Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 93 | 3 X 16 sq. mm (25mm) |
| 94 | 4 X 25 sq. mm |
| 95 | 4 X 35 sq. mm |
| 96 | 4CX 70 sq. mm |
| 97 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 98 | Supplying and fixing of following way surface / recess mounting, vertical type, 415 V, TPN MCB distribution board (MCCB incomer & MCB outgoings) of sheet steel, dust protected, duly powder painted, inclusive of 160 A tinned copper bus bar, common neutral link earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. |
| 99 | 8 way, MCCB+24 modules |
| 100 | Supplying and fixing Cable End box ( Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc as required. |
| 101 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts on surface/recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator.) |
| 102 | 12 Way, 12 Modules Double Door. |
| 103 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 104 | 4 way (4 + 12), Double door |
| 105 | 6 way (4 + 18), Double door |
| 106 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 107 | Single pole |
| 108 | Double pole |
| 109 | Triple pole |
| 110 | Supplying and fixing 40 A to 63 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 111 | Single pole |
| 112 | Triple Pole |
| 113 | Four Pole |
| 114 | Supply and fixing of following size and type, 415 volts, thermal magnetic release MCCB , having adjustable overload features. |
| 115 | 100 A 4 Pole, Breaking Capacity 25kA |
| 116 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 117 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 118 | 63 A |
| 119 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 120 | 1 run of cable |
| 121 | Supply of 3 Core 1.5 sq.mm. PVC insulated and PVC round sheathed Copper Cable. |
| 122 | Supply of 3 Core 2.5 sq.mm. PVC insulated and PVC round sheathed Copper Cable. |
| 123 | Supply, Installation and Testing of Telephone Socket Outlet including PVC box Connectors etc. complete as required. |
| 124 | Supply, Installation and Testing of IO box Suitable for LAN Connection incuding supply and fixing of connectors etc. Complete as required. |
| 125 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 126 | 100 mm X 100 mm X 60 mm deep |
| 127 | 200 mm X 250 mm X 60 mm deep |
| 128 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 129 | 5/6 A switch |
| 130 | 15/16 A switch |
| 131 | 3 pin 5/6 A socket outlet |
| 132 | 6 pin 15/16 A socket outlet |
| 133 | 16 A Kit Kat Fuse |
| 134 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 135 | 1 or 2 Module (75mmX75mm) |
| 136 | 3 Module (100mmX75mm) |
| 137 | 6 Module (200mmX75mm) |
| 138 | 8 Module (125mmX125mm) |
| 139 | 12 Module (200mmX150mm) |
| 140 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 141 | 5/6 A switch |
| 142 | 15/16 A switch |
| 143 | 3 pin 5/6 A socket outlet |
| 144 | 6 pin 15/16 A socket outlet |
| 145 | Telephone Socket Outlet |
| 146 | RJ 45 Internet socket Outlet, CAT 6. |
| 147 | Supplying and fixing following size/ modules premimum quality and decorative type, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(Make Havells Crabtree Crabtree Athena- Amare Decorative - Glittery Sand Glass or equivalent design & grade). |
| 148 | 1 or 2 Module (75mmX75mm) |
| 149 | 3 Module (100mmX75mm) |
| 150 | 4 Module (125mmX 125mm) |
| 151 | 6 Module (200mmX75mm) |
| 152 | 8 Module (125mmX125mm) |
| 153 | 12 Module (200mmX150mm) |
| 154 | Supplying and fixing following premium quality and decorative type modular switch/ socket/Blank plate on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (Make Havells Crabtree Athena- Moderna Elephant Grey or equivalent grade). |
| 155 | 10 A switch |
| 156 | 15/16 A switch |
| 157 | 3 pin 5/6 A socket outlet |
| 158 | 6 pin 15/16 A socket outlet |
| 159 | Telephone Socket Outlet |
| 160 | RJ 45 Internet socket Outlet, CAT 6. |
| 161 | Modular blanking plate |
| 162 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 163 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 164 | Supply of following Electrical items complete with all accessories: |
| 165 | Industrial Box type Luminaire suitable for Single T8 LED Tube (without Lamp) |
| 166 | Industrial Box type Luminaire suitable for Twin T8 LED Tube (without Lamps) |
| 167 | T8 LED Lamp20 -23 Watt, >2100 lm (Polycarbonet Body) for above fittings. |
| 168 | Supplying and fixing of following sizes of heavy dutyPVC Casing Capping/ Trunking along with accessories in surface including all accessories. |
| 169 | 20X12 mm |
| 170 | 75 x 50 mm |
| 171 | Supply, installation, Testing & Commissioning of recess mounted premium & decorative type Panel light 2x2 ft., CCT 3000°K / 4000°K/ 5700°K/6000°K/6500°KSystem lumen efficacy 100-120 lm/Watt output .Make: Crompton LED STELLUX-S Recess mounted Signature series premium commercial luminaire LCTRS-36-TL or equivalent grade & design. |
| 172 | 36 watt |
| 173 | LED Down lighter (COB Type) (System lumen efficacy ≥ 105 < 120lm/Watt ) Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K /4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminum Body including trim with Aluminum Reflector. |
| 174 | 12 -15 watt |
| 175 | LED Flood Light, powder coated pressure die cast aluminum(System lumen efficacy 105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above90°C). |
| 176 | 50 watt |
| 177 | 150 watt |
| 178 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range - 15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80, under voltage and over voltage protection, EMI-EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 179 | 50 watt |
| 180 | 90 watt |
| 181 | Brush Less Direct Current (BLDC) MotorSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req |
| 182 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 183 | Supply, installation and Testing of 450 mm sweep, 230 Volt AC,Copper Coil, Heavy duty Exhaust fan ( CG/ Usha/ Havells) including Louvers. |
| 184 | Supply, installation and Testing of 300 mm sweep, 230 Volt AC,Copper Coil, Heavy duty Exhaust fan ( CG/ Usha/ Havells) including Louvers. |
| 185 | Supply, installation and Testing of 400 mm sweep, 230 Volt AC,Copper Coil, oscillating type wall mounting fan with built in regulator complete as required. |
| 186 | Supply, installation and Testing of , 250 watt, 230 Volt industrial pedestal fan having following specifications.1. 750 mm sweep2. 250 watt (apprx.)3. 230 Volt4. 1440.00 RPM (apprx.) |
| 187 | Supply, Installation and Testing of Fan Regulator complete in all respect. |
| 188 | Supply, Installation and Testing of 21 A OLP-3 AC Starter including Modular Box etc. complete as required ( Electron OLP3+ or its Equivalent). |
| 189 | Supply, Installation, Testing and Commissioning of Automatic 2 AC Controller with provision of Time, Voltage and Current adjustment and protection facility (Parameters are to be user adjustable) complete as required. (Ultrasafe UTCON 07C or its equivalent make and model.) Installation part is including all accessories like Lugs, Screw, Bolts etc. |
| 190 | Supply and installation of corded landline phone comprising of following features.1. LCD screen can display upto 16 digits.2. Caller ID support.3. Time display & Call duration display4. Call memories & call transfer facility.5. Warranty: Minimum 1 year. |
| 191 | Supply and installation of cordless landline phone comprising of following features.1.LCD Display with Backlight2. Caller ID support.3. Text Based Menu, Time Display, Date Display and Call Duration Display, Missed Call Notification, speed dialing, 4. Call memories & call transfer facility.5.Conference Calls Enabled, Speaker phone6. The phone includes Base + Handset),AC Adaptor, Line Cord, Rechargeable Batteries etc as required. 7. Warranty: Minimum 1 year. |
| 192 | Supplying and Laying 3 core 2.5 sq. mm Copper Armoured cable, 1.1 KV grade in surface or in recess as required. |
| 193 | Supplying and Laying 3 core 4.0 sq. mm Copper Armoured cable, 1.1 KV grade in surface or in recess as required. |
| 194 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 195 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 40/63 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 196 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A, 415 V “C” curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 197 | Supplying and fixing 8 way 8 module sheet steel enclosure on surface/ recess along with 16/25/32 A, 415 V “C” curve TPN MCB complete with connections, testing and commissioning etc. as required. |
| 198 | Supplying and fixing8 way 8 module sheet steel enclosure on surface/ recess along with 40/63 A, 415 V “C” curve TPN MCB complete with connections, testing and commissioning etc. as required. |
| 199 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 60 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 200 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/ lamp etc., directly on ceiling / wall, including connections with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 201 | Installation of Street lights with MS bracket arm (5 ft. length & 30-40 mm dia) inclduding all accessores like reducers, saddle etc as required. |
| 202 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 203 | 150 mm width X 50 mm depth X 1.6 mm thickness. |
| 204 | 300 mm width X 50 mm depth X 1.6 mm thickness. |
| 205 | Earthing with G.I. earth plate 600mm X 600mm X 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 206 | Providing and fixing 25mm X 5mm G.I. strip on surface or in recess for connections etc. as required. |
| 207 | Dismantling of power boards, DBS, Cables, Wirings, Light Fittings, Fans etc. includingsurface/ recessed wiring/ Cabling from the source, cable end termination and removal and refixing of Fire Detectors, Fans (if required) etc. at Labs / Rooms etc. of CSIR-IICB, Jadavpur, Campus.The dismantled materials are to be kept at the specified location within the Institute campus as directed by the Engineer-in-charge of the work. For removal and refixing of Fire Detectors / Alarm System, persons having knowledge in the similar field, are to be engaged. |
| 208 | Dismantling of following size surface mounted existing metal switch boards includingphenolic laminated sheet cover and refixing in recess (concealed) including cutting of wall and finishing the same with sand, cement etc. |
| 209 | 100 mm X 100 mm X 60 mm deep |
| 210 | 125 mm X 75 mm X 60 mm deep/ 4 Module |
| 211 | 200 mm X 250 mm X 60 mm deep |
| 212 | 250 mm X 300 mm X 60 mm deep |
| 213 | Dismantling of following size surface mounted existing Wiring for circuit/ submain wiring alongwith earth wire with the 1.5/2.5/4.0 sq.mm. of FRLS PVC insulated copper conductor, single core cable in surface mounted 20/25 mm. PVC conduit and refixing the same in recess (concealed) including cutting of wall and finishing the same with sand, cement etc. |
| 214 | Engaging of man power for execution of miscellaneous Electrical Works as per direction of Engineer-In-Charge.(Other than above mentioned work.) |
| 215 | Skilled |
| 216 | Unskilled |
| 217 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. |
| 218 | HI - WALLSPLIT SYSTEMSSupply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut-off and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 degC (out door ambient temperature).Inverter Type - Cooling only |
| 219 | 2.0 TR with 5 Star BEE Rating |
| 220 | Removal of existing Split type AC units(1.5 / 2.0 TR capacity): Removal of different makes & models Split type AC units from the specific location and keeping the dismantled AC units to store / place / location as indicated by the Engineer in charge within institute campus. This work is inclusive pump down of Compressor for restore the refrigerant gas, removal of existing refrigerant pipe lines, drain line, bracket etc. and making arrangement of covering the holes for split AC pipe lines and blocking of pocket with white cement /putty or ply wooden board and nails (as applicable) as required to meet actual site requirement. |
| 221 | Re-installation of existing Split type AC Units (1.5 / 2.0 TR capacity): Standard complete Re-installation of existing Split type AC Units (different makes & models) for installation / shifting the same from one place to another place as indicated by the Engineer in charge / Lab in charge within the institute campus. This work is inclusive of all necessary work like Overhauling & Servicing (for existing AC units) , Laying & fixing of Copper pipes with insulation & Wrapping tape, Laying & fixing of Electric Wires & Drain Pipes, fixing of bracket, Leak testing, required Refrigerant Gas charging, necessary ply wooden board fixing & painting the same, covering the holes with white cement / putty if any etc. as required to meet actual site requirementfor installation of AC units and run smooth functioning of the same . |
| 222 | COPPER REFRIGERANT PIPING :Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : |
| 223 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 224 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 225 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 226 | Providing interconnected 1.1 KV, FRLS, 4 Core x 2.5 Sq. mm Electric Wire (multi-strand)for Electrical connection of Indoor & Outdoor units of Split AC units |
| 227 | Providing suitable size heavy duty wall mounted Bracket (steel material, L shape , powder coated finish) including fasteners for fixing of outdoor unit of 1.5 / 2.0 ton capacity AC units. |
| 228 | Providing suitable size hard braided pipe (ID16 mm, OD-20 mm, wall thickness-2-2.5 mm, material (inner layer): soft PVC or LDPE, outer layer: braided mesh reinforcement, Colour- White / Blue ) for condensate drainage lineof split AC units |
| 229 | Providing suitable Refrigerant Gas (R-22 /33/410 or eco friendly) for different makes & modelsAC units |
| 230 | Providing Heavy duty Ply wooden Board (thickness 19 mm or above or equivalent)for installation of IDU Split AC units |
| 231 | Providing of 16 Amps , ISI marked 3 pin Plug Top made of fire-retardant polycarbonate body with brass pins and screw terminals suitable for use split AC unit for Electrical connection |
| 232 | Supply of universal AC remote Compatible with most of The Brands Like Voltas, Carrier, Blue Star, Weather Makers, Electrolux, Hitachi, LG, Samsung, Whirlpool, Lloyd etc. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail