| 1 | Supplying and laying of the following size PVC insulated and PVC sheathed / XLPE Aluminium power cable of 1.1 KV grade cable in existing RCC/ HUME/ METAL pipe etc., as required. |
| 2 | a) 4 X 25 sq. mm |
| 3 | b) 3 1/2 X 50 sq. mm |
| 4 | c) 3 1/2 X 70 sq. mm |
| 5 | Supplying and laying ofthe following size PVC insulated and PVC sheathed / XLPE Aluminium power cable of 1.1 KV grade cable on surface of wall etc., as required. |
| 6 | a) 4 X 25 sq. mm |
| 7 | b) 3 1/2 X 50 sq. mm |
| 8 | c) 3 1/2 X 70 sq. mm |
| 9 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 10 | a) 4 X 25 sq. mm |
| 11 | b) 3 1/2 X 50 sq. mm |
| 12 | C) 3 1/2 X 70 sq. mm |
| 13 | Supplying and laying 40mm dia HDPE pipe of 8 Kgf/cm2 in the following manner for cable protection |
| 14 | a) Direct in ground i/c excavation, refilling and making good the surface |
| 15 | Supplying and fixing of SMC sheet outdoor type service connection board with IP-65 protection of size not less than 600 mm x 500 mm x 250 mmon existing MS angle iron/surface of wall i/c necessary drilling, nut bolds etc., as required. |
| 16 | Supplying and fixing of followingrating isolator /MCBs in existing DB/ Meter Box etc, as reqd |
| 17 | a) 100 A Rewirable fuse cutout with base ( Per Number) |
| 18 | b) 63 A Rewirable fuse cutout with base ( Per Number) |
| 19 | c) 100/63 A Neutral link ( Per Number) |
| 20 | d) 10 mm thick hylam sheet for meter board including cutting, drilling etc. |
| 21 | e) 100 A Four Pole Isolator |
| 22 | f) 5- 32 A Single pole |
| 23 | Providing & fixing GI busbar arrangement with the following items inside the shelter for proper earthing a) 25mm x 3mm GI strip (Approx Length – 300mm)b) Insulator - 2NosAll the above consists of |
| 24 | Supply and laying of Overhead Service connection arrangement of following size PVC insulated Al. conductor wire in the following manner |
| 25 | a) 4 x 16 sqmm In air with 2 run insulated GI of stay wire and PVC separator |
| 26 | b) 4 x 25 sqmm In air with 2 run insulated GI of stay wire and PVC separator |
| 27 | c) 4 x 16 sqmm In loose looping/existing pipe |
| 28 | d) 4 x 25 sqmm In loose looping/existing pipe |
| 29 | Supplying and laying of 40 mm diameter \"B\" class G.I. pipe in a vertical position, including all necessary alignment, supports, and fixtures. The work includes supply and fixing of L-bow, bends, and other required fittings, along with all labour for positioning, securing the pipe in place etc., as required. |
| 30 | a) 40 mm diameter |
| 31 | Supplying and Laying 4 X 25 sq.mm PVC insulated single core multi strand copper conductor wire with suitable sockets in the existing PVC pipe/LT panel etc., as required. |
| 32 | Supplying and fixing of 40 mm dia PVC pipe (6 Kgf/cm²) along with the accessories in surface/recess including cutting the wall and making good the same necessary clamping etc required. |
| 33 | Supplying and fixing 3 phase cable bus bar chamber of size not less than 300mmX450mmX200mm depth with suitable size aluminium bus bar capable of not less than 100 Amp etc., as required. |
| 34 | Supplying / Fixing of 4 pole 63 A, ON LOAD changeover switch in sheet steel enclosure suitable for operation on 415V, 50Hz, 3 Phase AC supply including fixing on surface of wall including testing and commissioning etc., as reqd. (Make: L&T or S/S make) |
| 35 | Dismantling of old Electricity meter box along with accessories such asold service cable/wire etc ., as required. |
| 36 | Checking of electrical circuits, load balancing and co-ordination with Puducherry EB department officials for wire termination at poles EB metering panel and shutdown of EB power supply etc., as required. |
| 37 | Supplying and fixing of M.S steel sections of following size for fixing the existing Meter box/DB box etc., as required. |
| 38 | a) MS angle (38X38X6mm) |
| 39 | b) MS flate (38X6mm) |
| 40 | S/L of 1x10sq.mm copper wire with lug for both endfor loop earthing as required |