| 1 | Disconnecting and taking down the existing street light fittings from poles and gate light of any type or any wattage for cleaning by removing the dusts, insects from the inside of the light, repair/replacement andre-fixing the same complete all on the direction of Engineer-in-Charge all as specified and as directed. Note - Spare parts will be measured and paid for seperately. |
| 2 | Supply only electronic driver , as per existing sample suitable for street light fitting 45/60/90 Watt ,complete all as specified and directed. |
| 3 | Supply only PVC insulated and PVC sheathed copper flexible cable stranded of 1.5 sqmm twin core flat or circular with connection from light fittings to OH conductor or upto junction box ,complete all as specified and directed. |
| 4 | Supply only PVC insulated and PVC sheathed Aluminium flexible cable stranded of 6 sqmm twin core flat or circular with connection from light fittings to OH conductor or upto junction box ,complete all as specified and directed. |
| 5 | Supply and fix in replacement 1 x 45 Watt, LED street light fitting, powder coated pressure die cast aluminium compact High power with heat resistant toughened glass with lens, priple locked with built in short circuit protection, over load protection, and surge protection, High/low voltage cut off a,complete all as specified and directed. |
| 6 | Supply and fix in replacement 1 x 60 Watt, LED street light fitting, powder coated pressure die cast aluminium compact High power with heat resistant toughened glass with lens, priple locked with built in short circuit protection, over load protection, and surge protection, High/low voltage cut off ,complete all as specified and directed. |
| 7 | Supply and fix in replacement of 1 x 30 watt Circular or square LED Flood light with innovative finless design and excellent thermal management and light distribution along with IP66 protection ,complete all as specified and directed. |
| 8 | Disconnecting and taking down the existing unserviceable post top lantern/ gate/ garden light fittings from gates/ poles of any type or any make for cleaning by removing the dusts, insects from the inside of compartment,repair/replacement of unserviceable spares andre-fixing the same ,complete all as specified and directed.Note - (a) Spare parts will be measured and paid for seperately.(b) Necessary dismantling and new PCC work /touch up work ifrequired to make existing surface as existing etc shalldeemed to be included in the quoted rates. |
| 9 | Supply and fix in replacement of gate light / LED Post Top lantern moonlight effect and efficient light distribution with IP65 protection of capacity 40 watt mounted on existing Pipe 40/50 mm bore ,complete all as specified and directed. |
| 10 | Supply and fix in replacement of Integral pole mounted decorative LED post top light of capacity 25 watt with spherical shade polycarbonate diffuser and IP65 protection,complete all as specified and directed. |
| 11 | Supply and fix in replacement of LED Bollard light fittings 10 W IP65 protection with robust design and efficient light distribution complete including Plain cement concrete foundation 30x30x30 cm ,complete all as specified and directed. |
| 12 | Disconnecting and taking down the existing street light timer from poles of any type or any make for cleaning by removing the dusts, insects from the inside of compartment,repair/replacement of unserviceable spares andre- fixing the same ,complete all as specified and directed.Note - Spare parts will be measured and paid for seperately. |
| 13 | Supply only nature time switch, 230 V automatically switching ON/OFF as per seasonal changes single phase upto 5 KW capacity,complete all as specified and directed. |
| 14 | Supply only time switch 3 phase with 48 hours back-upcharge programmable and operated within 5 minutes of preset time of current rating 32 amps ,complete all as specified and directed. |
| 15 | Supply only power contractor TP 415 volts, 32 amps without aux relay suitable for operating of timer switch ,complete all as specified and directed. |
| 16 | Supply only MCB SP 32 Amps 240 volts 10 KA ,complete all as specified and directed. |
| 17 | Supply only MCB DP upto 40 Amps ,complete all as specified and directed. |
| 18 | Supply and replacement of Prestressed concrete pole size 9 Mtr long 102 mm x 172 mm at top and 102 mm x 279 mm at bottoms class-10 including painting 5 Nos of strips in white and black colour 30 cm wide above Plain cement concrete couping on ground level and numbering,complete all as specified and directed. |
| 19 | Supply and fix in repair and replacementswitch fuse iron clad of sheet metal SP fused and neutral link 32 Amps 240 volts,complete all as specified and directed. |
| 20 | Earthing in repair complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanised iron strip, size 32x6mm as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test pointetc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge. Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.(ii) GI earth strip 32x6mm and GI medium grade pipe 40mm dia upto 7.50mtrs long shall be deemed to be included in the unit quoted rate. (iii) The earth pit shall be redone if the desired earth resistance value is not obtained by the contractor at no extra cost to the department. |
| 21 | Dismantling and taking down defective high mast light fitting with complete assembly by engaging suitable heavy duty crane/ Hydra machine from pole upto 20 mtr height using electrically operated winch, repairing and refixing after replacing all unserviceable parts including internal wiring complete all as specified and directed by Engineer-in-Charge.Note : (a)Light fittings shall be measured and paid for separately.(b)Spares such as steel wire, winch motor, cable etc shall be measured and paid for separately. c) The entire work shall be carried out by well experienced professionals who has already carried out the high mast poles dismantling /repair works and similar works. d) Cost Minor fittings/fixtures such as screws, bolt/nuts, grease etc shall provided by the contractor without any extra cost to the Govt to make fucntional lights and nothing shall be admissible on this ground. |
| 22 | Supply only stainless steel rope twisted of size 10 mm dia with necessary connections proper binding on both sides from bottom drum to high mast top connection hook , complete all as specified and directed . |
| 23 | Supply only fractional 1.5 HP motor 415 volts suitable for electrically operated high mast light, complete all as specified and directed . |
| 24 | Supply only PVC insulated and PVC sheathed Aluminium flexible cable stranded of 4 sqmm twin core flat or circular with connection from light fittings to OH conductor or upto junction box a, complete all as specified and directed . |
| 25 | Supply only Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 ,150watt flood light, suitable for highlighting architectural facade and general purpose lighting along with connected accessories , complete all as specified and directed . |
| 26 | Supply only Integral LED aviation light fitting 10watt Integral LED aviation light comprising of aluminium housing with polycarbonate enclosure, complete all as specified and directed . |
| 27 | Supply only electronic LED driver for LED light fittings, capacity 45/ 50 Watt, 50Hz,, complete all as specified and directed . |
| 28 | Supply only electronic LED driver for LED light fittings, capacity 60 Watt, 50Hz, complete all as specified and directed . |
| 29 | Supply and fixing in repalcementbracket made out of GI pipe 1.5 Mtr long, 40 mm dia light grade bent to shape as directed including clamps made out of 40 mm x 6 mm flat for fixing bracket suitable for Plain cement concrete poles including nuts and bolts, washers and other connected items of required size including painting with one coat of aluminium paint over a coat of red oxide/primer , complete all as specified and directed . |
| 30 | Supply and fixing in repair XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area of size 6 Sq mm, 2 core , complete all as specified and directed . |
| 31 | Supply and fixing in repair XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area of size 10 Sq mm, 2 core, complete all as specified and directed . |
| 32 | Supply and fixing in repair XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area of size 16 Sq mm, 4 core , complete all as specified and directed . |
| 33 | Supply and fixing in repair XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area of size 25 Sq mm, 4 core , complete all as specified and directed . |
| 34 | Supply and fixing in repairXLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area of size 35 Sq mm, 3.5 core, complete all as specified and directed . |
| 35 | Supply and fixing in repair XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area of size 50 Sq mm, 3.5 core , complete all as specified and directed . |
| 36 | Excavation in trenches in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable,erection of poles, stays, pipes etc and not exceeding 10sqm on plan and getting out , complete all as specified and directed . |
| 37 | Excavation in trenches not exceeding 1.50 mtr wide andexceeding 1.50mtr but not exceeding 3.0mtrs in depth, not exceeding 10 Sqm on plan and getting out, in any type of soil, for laying electric cables or foundation of poles/ stays etc, complete all as specified and directed . |
| 38 | Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm , complete all as specified and directed . |
| 39 | Removal of excavated material not exceeding 50 mtr and depositing where directed at a level n.exc 1.5 mtr above in starting point, complete all as specified and directed . |
| 40 | Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed . Note: Punned thickness shall be measured. |
| 41 | Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed . |
| 42 | M&L providing plain cement concrete 1:4:8 type D-2(using 40 mm graded crushed stone aggregate) for filling in foundations of LT poles/garden light fitting, complete all as specified and directed . |
| 43 | M&L for providing plain cement concrete 1:3:6 type C-2 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary form work and finished the surface, complete all as specified and directed . |
| 44 | Supply and fixing in repairPVC junction box of size 200MMx2500MMx95MM mounted on GI pipe with MS clamp made out of 40 mm x 6 mm flat for fixing box on pole/wall including four poles terminal points mounted on epoxy insulator for cable connection with 01 No MCB SP 0-32 amp , complete all as specified and directed . |
| 45 | Supply and fixing in repair GI pipe light grade of size 40 mm bore of any height mounted on plain cement concrete foundation at existing position, complete all as specified and directed . |
| 46 | Design,Supply, installation, testing and commissioning including taking down old Cubical type floor mounted LT panel, of minimumsuitable sizeoutdoor typefactory fabricatedmade out of CRCA sheet of minimum thickness 3.15 mm,fully enclosedand angle iron frame of size 40 x 40 x 6mm thick and T section with front openabledouble door shutter, dust and vermin proofand rear openingcomplete with locking arrangement, having a system of bus barsof aluminiumof suitable size of 200 Amps duly insulated and mounted on Epoxy/porcelain insulators in totally enclosed chamber with three phase and neutral 415volts, AC, system prewired with suitable copper wire PVC insulated with all control accessories, provn of suitable cable glands, duly powder coated of approved quality over a coat of red primer with sufficient free space complete to include the following accessories:- (a) MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 16 KA-01 No(b) MCCB 3 Pole, 415 V, fixed type, 63 Amps with breaking capacity 16 KA-03 Nos (c) Digital volt meter 0 to 500 volts with selector switch-1 No (d) Digital Ammeter 0 to 350 Ampswith CTs of suitable Amps and selector switch-1 No (f) Indicator lampRYB- 01 Set |
| 47 | Earthing in repair complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanised iron wire of 4.0mm dia as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test pointetc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed. Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.(ii) GI earth lead 4.0mm dia and GI medium grade pipoe 15mm dia upto 7.50mtrs long shall be deemed to be included in the unit quoted rate. (iii) The earth pit shall be redone if the desired earth resistance value is not obtained by the contractor at no extra cost to the department. |