| 1 | Taking out unserviceable LT cable of any size from trenches/duct etc carefully including bricks and keeping in safe custody either for relaying or disposalcomplete all as specified and directed |
| 2 | Supply, laying jointing and testing10 Sqmm 4 core XLPE insulated LT under ground cable, 1100 volts grade heavy duty, armoured with multi stranded aluminium conductor laid in trenches/ ducts pipes or on poles etc complete all as specified and directed. Make - Havells/Polycab/Finolex/ Plaza/ RR Cable. |
| 3 | Supply, laying jointing and testing35 Sqmm 3.5 core XLPE insulated LT under ground cable, 1100 volts grade heavy duty, armoured with multi stranded aluminium conductor laid in trenches/ ducts pipes or on poles etc complete all as specified and directed Make - Havells/Polycab/Finolex/Plaza RR Cable. |
| 4 | Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc complete all as sepecified and directed. |
| 5 | Returning filling in, including spreading, levelling, watering and well ramming soil in layers not excuding 25 cm thickness complete all as specified and directed. |
| 6 | Removing surplus excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point. Complete all as specified and directed. |
| 7 | M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation complete all as specified and directed.(Note:- Only punned thickness of send shall be measuredand paid). |
| 8 | Supply and laying well burnt sub class ‘B’ bricks, locally best available laid in trenches for protection of underground cable complete all as specified and directed. |
| 9 | M & L for boring of holes under road, pavement, hard standing by trenchless boring manually or by machine for insertion ofGIpipe of size upto 40 mm dia suitable complete all as specified and directed. |
| 10 | S&F GI pipe 40 mmlight grade with all fitting fixed to electric pole and laid in road crossingfor cable protection with suitable size clamp, nut bolt and washers complete all as specified and directed. Make : Tata/Jindal/swastik/ Prakash Surya. |
| 11 | F&S in repairold rusted street light bracket, clamps, nuts and bolt with new street light bracket made out of 32 mm dia light grade GI pipe(length of pipe should not be lessthan 1.2 mtrs) , two set of clamp made out of 25 mm x 3 mm flat iron, nuts & bolts as required , bend to shape andfixing arrangement duly welded complete all as specified and directed. |
| 12 | S&F in replacement of old unserviceable normal Street light fitting with new generation energy saving environemental friendly long life LED street light made up of pressure die cast aluminium housingwith lens, energy efficient high quality consistency, glare control with toughned glass and individual high power LEDs with secondary optics ,IP66 protection and impact of capacity 60 Watt complete all as specified and directed. Make:- Havells/Philips/Syska/CG/ Bajaj. |
| 13 | S&F in replacement of old unserviceable normal flood light fitting with new generation energy saving environement friendly long life exclusive innovative die cast aluminium IP66LED flood light with high power LEDs as light source of capacity 120 Watt complete all as specified and directed. Make:- Havells/Philips/Syska/CG/Bajaj. |
| 14 | S&F replacement of old unserviceable normal flood light fitting with new generation energy saving environement friendly long life exclusive innovative die cast aluminium IP66LED flood light with high power LEDs as light source of capacity 250 Watt complete all as specified and directed. Make:- Havells/Philips/Syska/RR Cable. |
| 15 | S & F in repair service connection 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tap and over all PVC sheathed of size 10 Sqmm 2 core complete all as specified and directed. Make :-Palza/Polycab/Havells. |
| 16 | S&F in replacement old unserveceable cable junction boxwith newpole mounted thermoplastic cable junction box for steet light 4.5 modulewith IP-65 protection, halogen free and weather proof with metric knockouts for cable entryfor outdoor installation of approx size 126 mm x 288mm x 111 mm with front door opening system including terminals for one incoming and two outgoing cables of size 16/25 sqmm 4 core, one MCB SP 3 to 6 Amp 240V AC with mounting clamp of flat iron, nut, bolt and washers complete all as specified and directed .Make of junction box -Hensel / Syntex / Havells/ Legrand/ C&S. |
| 17 | M&L for painting of existing LT/HTpole upto 9 / 11meter heightwith twocoat of aluminium paint complete including preparation of old painted surfaces and including makingblue / black colour paintstrip of 15 cm width including writing the Pole Nos.complete all as specified and directed. |
| 18 | S&F Photonic Astronomical timer switches (Having Latitude and Longitude at the installed location of Indian cities in memory) 150V to 260V AC, 50 HZ single phase of 15000 watts rating with dual mode operation (Asronomical timer/Real time clock) , location accuracy + 1 degree, clock accuracy +1 second and provided to delay \"Switch ON\" Lights after sunset PFF offset provided to early \"Switch OFF\" lights before sunrise time, RTC mode input ON and OFF time clock based with on delay 0-99 seconds user adjustable and dual relay can be individually programmed with control MCB and auto/manual switch, 4 pole contactor complete with steel encosure duly painted and fixing MS clamps for mounted on pole complete all as specified and directed. |
| 19 | S&F in repair aviation light fitting with integral LED aviation light comprising of aluminium housing with polycarbonate enclosure capacity 20 Watt complete all as specified and directed. Make:Philips/Havells/Syska/ CG/ Bajaj |
| 20 | M&L for PVC insulated sheathed aluminium conductor cableof size 6.0 Sqmm, 2 core for connection including PVC conduit with clamps, nuts & bolts of suitable size or drawing through pole or GI brackets of street light fittings to junction box complete all as specified and directed.Make : Plaza/Finolex/Havells/Polycab |
| 21 | M & L for repair/replacement ofhigher efficiency crystalline SPG solar panel of 30 watt capacity with 14 AH battery mounting height 5 to 6 mtr IP 65 protection complete all as specified and as directed. |
| 22 | S&F in repair/replacement ofhigher efficiency crystalline SPG solar panel of 20 watt capacity rated voltage 12.8 V DC with 10.5 AH battery mounting height 5 to 6 mtr IP 65 protection complete all as specified and directed. |
| 23 | Cutting and trimming of tree branches 2 mtr all around of single pole any size obstructing lumination of street light pole removing trimmed tree branches and bushes. Complete all as specified and directed. |