| 1 | Attending and rectifying all type of electrical complaints of all non operational area including buildings up to 3 Mtrs at HWPK plant site, Job includes problem rectification of lights, Fans, including Temporary light cable lying/ wiring work etc.Note: Any job at ground elevation or using portable ladder. |
| 2 | Attending and rectifying all type of electrical complaints height up to 3 mtrs in plant operating area Job includes problem rectification including Tempory light,cable laying/ wiringwork etc.Note: Any job at ground elevation or using portable ladder. |
| 3 | Attending and rectifying all type of electrical complaints height more than 3 mtrs any where in the plant including street light.Job includes problem rectification of lights, including cable laying at existing cable tray/cable trench Note: Any job requiring wheel mounted ladder/ scaffold. |
| 4 | AMC of Air Conditioners:Following jobs shall be carried out through out the contract period:-a) Bi-monthly preventive maintenance of window/split/cassette type ACs b) Attending the day to day complains/ breakdown maintenance c) All type of maintenacelike replacement of compressor, leak test, Gas charging, replacement ofblower, condenser fan are under the scope of vender. Under preventive maintenance jobsare cleaning of filters, condenser and evaporator, checking of the all power connection. replacement of overheated lugs of the compressor, performance check of ACs &record the current & Temp of the cold air with the help of digital thermometer. As per the requirement supply and replacement of minor components i.e.thimbles,knobs, rubber bush etcas per requirement and cells for remote (Min 100Nos Cells to be supplied & 200 Nos Thimbles for compressor), are under the scope of vender. Detailed technical specifications is attached. Note: Digital Thermometer should be provided by the vendor and available with AC Mechanics. All tools tackles including LPG cane for brazzing are under the scope of vender |
| 5 | Drinking Water Coolers:Following jobs shall be carried out through out the contract period:-a) Monthly cleaning of the water storage tank of drinking water coolers with cleaning agents and steel brush including cleaning of the water collecting tray. After cleaning the tank,top cover should be sealed with brown tape b) Attending the day to day complains/ breakdown maintenance c) All type of maintenacelike replacement of compressor, leak test, Gas charging, replacement ofblower, condenser fan are under the scope of vender. Under maintenance jobsare replacement of overheated lugs of the compressor, . performance check of water coolers, shifting of water cooler from one location to another location as per requirement. Supply and replacement of minor components i.e. fan capacitors up to 4 micro farad (metallic), knobs, rubber bush etcas per requirement are under the scope of vender. Detailed technical specifications is attached. All tools tackles including LPG cane for brazzing are under the scope of vender |
| 6 | Drawl of the materials from the central stores and carrying it to sectional store arrangement of items at sectional store as per instructions of store in charge. Updating inventory status and segregation of the scrap materials and hand over to the store. (1 lot= each type of item drawn fromor handed over to central stores every time) |
| 7 | Replacement of the damaged LED lights / conventionals lights, installation of new points in buildings/ any modification works or attending the points raised by SSC |
| 8 | Supply of following spare parts / components of OEM / genuine / reputed make for split type / window type air conditioners, water cooler/ desert cooler as per technical specifications. All spares / components shall be got approved from EIC. |
| 9 | 1.5 TR capacity Rotary type compressor suitable for R22Gas -4 Nos,R32 Gas -2 Noswith base rubber bush (grommet) for air conditionerMake Whirphool/ Highly along with Complete Compressore wiring kit. |
| 10 | 2 TR capacity Rotary type compressor suitable for R32Gas -4 Nos, with base rubber bush (grommet) for air conditionerMake Whirphool/ Highly along with Complete Compressore wiring kit. |
| 11 | 15 mfd 440 volt Capacitor Havells440 V Model No QHPPSS5015X0 15 MFD / 440 V / PLSFO |
| 12 | High Pressure Washer Machine 1800 Watts approximate and Pressure 120 Bar for Cleaning of Air conditioning unit (Indoor & out door fins) |
| 13 | Refrigerant Gas: Supplyof Refrigerant gas (R-22/R-32/R410/R134 gas) as per requirement (Quantity will be executed as per actual requirement) |
| 14 | Supply of complete Indoor unit suitable for 2.0Tr split AC of R32 |
| 15 | Supply of AC LG/Voltas 1.5Tr Inverter Air Conditioner PCB, For Circuit Board |
| 16 | Supply of complete 22 gauge GI body Single door desert cooler along with Gril,Honey comb cellulose pads, water distribution pipe from pump to pad & control panel (Fan & Pump swich for ON/Off & Cooler Regulator Dimmer Speed Full To Zero Rotaration Out put 100 – 160 W approx, 230 V, 1 ph. AC supply, ISI marked and suitable for 3-speed regulator.Size of cooler should be not less than of size 25\"(L)x 25\"(W) x 25-26.5\"(H). |
| 17 | Supply of spares of light luminers |
| 18 | Supply & installation ofSolar LED Street Light Outdoor Waterproof 50 Watt Wireless Motion Sensor high Power Lamp for Home, Garden, Dusk to Dawn (4000mAh/3.2V Cool Light) black, suitable for pole mounted |
| 19 | 36 Watt LED MCPCB for panel LightService along with High Lumen LED 100-140 Lumen Per Watt - Colour: White - 6500 Kas per techncal specification |
| 20 | 36 Watt panel light driver meeting to the light of item no 10.2 as per techncal specification |
| 21 | Supply of following hardwares for use of day to day maintenance (Lot means supply of all materials mentioned in this item as per quantity mentioned):- |
| 22 | Taparia 9\" X 11\" Silicon Carbide Wet Or Dry Emery Sheet, Grit 200, 320, 400.( each type 200 Nostotal 600 Nos) |
| 23 | Anchor Fasteners, Size: 6 MM, Total Length 5 Cm, |
| 24 | Anchor Fasteners,Size: 8 MM, Total Length 6 Cm, |
| 25 | Zinc Plated Pin Drive Expansion Bolts-Hammer Strike Pin Anchor Fasteners (10 MM x 75 MM), |
| 26 | Havells Make Industrial type 3 Pin Receptical top 32A Single Phase |
| 27 | Havells Make Industrial type 3 Pin Receptical top 20A Single Phase |
| 28 | Plug Top 6A, 3 Pin, with LED Indicator, ISI Certified, Ideal for ACs, Geysers, Fridges & More – White |
| 29 | Plug Top 16A, 3 Pin, ISI Certified, Secure Fit for Home, Office & Appliance Use – White |
| 30 | BOSCH 24 TPI HSS 12\"All Hard Hacksaw Blade, HSS 1224 |
| 31 | BOSCH 150mm Hacksaw Blades 24Tpi Durable, Precise, And Long-Lasting For Clean Cuts in Metal. |
| 32 | 1.5 Inch / 38 mm Plastic Wall Plugs | Rawl Plugs | Nylon Plugs | Gitty | |
| 33 | TAPARIA /Bouch 6 mm Flat Tip Masonry Drill Bit for Wall/Masonary Drilling (MD 6150, 6x90x150 mm, |
| 34 | 220V wired Door call bell single sound |
| 35 | Thermostate for water geyser |
| 36 | Supply & as per requirement installation of following rating Siemens make Fuse link |
| 37 | 3NWNS 10 Amps |
| 38 | 3NA78050RC Size 000 16 Amps |
| 39 | Supply of following Havells Modular |
| 40 | 6A shuttered socket with ISI marking AHLKPXW063 |
| 41 | 6/16A shuttered socket with ISI marking AHLKCXW163 |
| 42 | 10AX One way switch AHCSXXW101 |
| 43 | 16AX One way switch AHCSXXW161 |
| 44 | 8 Module Polycarbonate switchboards Size23.7x8.9) cm / (9.3X3.5in inch) AHNXMIZH08 along with 8M Front plateACYPLCWH08 with fixing screw |
| 45 | 12 Module Polycarbonate switchboards Size (21.4x14.9) cm / (8.4X5.9) inch AHNXMIZX12 alongwith 12M Front plate ACYPLCWV12 with fixing screw |
| 46 | The maintenance of street light poles at plant area. Job involves Repair of pole foundation,and painting the poles, JB on the poles and cable conduits near by the pole. The painting process after manually and/or mechanical cleaning of entire surface and removing oil, grease, rust, loose mill scale or existing primer as per specification and as directed by the engineer. Applying the coat ofred oxide primer each of 40 to 45 micron per coat dry film thickness of approved make and after word2 coat of Al Paint. Supply of the paint, brush & other require tools is under the scope of vender. Poles are included all type of poles & old towers except Hi Mast Tower. Once the painting is completed, the name of the Steet light Pole will be written onblack background with white paint. Each letter measuring Min 3 inches in size as per the instruction of EIC.contractor should deployed their own supervisor for this work. |