Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | PART-A CIVIL WORKEARTH WORK |
| 2 | Earth work in surface excavationnot exceeding 30 cm in depthbut exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lif upto 1.5 m, as directed by Engineer-in- Charge: |
| 3 | All kinds of soil |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. |
| 5 | All kinds of soil |
| 6 | Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: |
| 7 | All kinds of soil |
| 8 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 9 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 10 | Pruning, trimming, shaping of trees /shrubs (ht 15 feet and above) i/c removal of cut materials upto 50mt. stacking of serviceable material and disposal of unserviceable material. Lead, as per direction of officer in charge. T&Pshall be arranged by the contractor |
| 11 | CEMENT CONCRETE (CAST IN SITU) |
| 12 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 13 | 1:2:4 (1cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 14 | 1:3:6 (1Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 15 | Makingplinthprotection 50mmthickofcementconcrete 1:3:6 (1cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 16 | Extra for addition of synthetic Polyester triangular fibre of length 12mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement concrete/ RCC/ Flooring/ water retaining structures by using 125 gram of synthetic Polyester triangular fibre for 50 kg cement used as per direction of Engineer-in-Charge. |
| 17 | REINFORCED CEMENT CONCRETE |
| 18 | Providing and laying in position specified grade of reinforced cement concrete,excludingthecostofcentering,shuttering,finishingand reinforcement - All work up to plinth level : |
| 19 | 1:2:4 (1cement : 2 coarse sand(zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 21 | Edges of slabs and breaks in floors and walls |
| 22 | Under 20 cm wide |
| 23 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. |
| 24 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 25 | MASONRY WORK |
| 26 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 27 | Cement mortar 1:4(1 cement :4 coarse sand) |
| 28 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 29 | Cement mortar 1:4(1 cement :4 coarse sand) |
| 30 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 31 | Cement mortar 1:3(1 cement :3 coarse sand) |
| 32 | CLADDING WORK |
| 33 | Providingandfixing 18mmthickgangsawcut,mirrorpolished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters,window sills,facias andsimilar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. |
| 34 | Granite stone slab of colour black, Cherry/Ruby red |
| 35 | Area of slab over 0.50 sqm |
| 36 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 37 | Granite work |
| 38 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 39 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 40 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions/Bathroom quadrant shelves by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. |
| 41 | Granite Stone of approved shade |
| 42 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 43 | WOOD AND P. V. C. WORK |
| 44 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 45 | Second class teak wood |
| 46 | Providing and fixing panelled or panelled and glazed shutters for doors, windows andclerestory windows, fixing withbutt hinges of required size withnecessary screws,excludingpanellingwhichwillbepaid forseparately,allcompleteasperdirectionofEngineer-in-charge.(Note: Butt hinges and necessary screws shall be paid separately) |
| 47 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. |
| 48 | Second class teak wood |
| 49 | 30 mm thick |
| 50 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202(Part I) decorative type,core of block boardconstruction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 51 | 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 52 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 53 | Providingandfixingchromiumplatedbrass curtainrodhaving wall thickness of 1.25 mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete: |
| 54 | 25 mm dia |
| 55 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 56 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 57 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : |
| 58 | 100x10 mm |
| 59 | Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. |
| 60 | Size 65 mm |
| 61 | Providing and fixing magnetic catcher of approved quality in cupboard/ ward robe shutters, including fixing with necessary screws etc. complete. |
| 62 | Double strip (horizontal type) |
| 63 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 64 | Providing and fixing to existing door frames. |
| 65 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of requiredcolour andapprovedbrandand manufacture,made with fire - retardant grade unsaturated polyester resin,moulded to 3mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. |
| 66 | Providingandfixingcupboardshutterwith 19mmthickoneside decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2 mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge. (Payment of providing and fixing auto closing hinges shall be paid separately) |
| 67 | Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. |
| 68 | 200 mm |
| 69 | Providing and fixing stainless steel sof closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge. |
| 70 | Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approvedmake500mmlongwithscrewsetc. complete as per direction of Engineer- in-charge, |
| 71 | STEEL WORK |
| 72 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 73 | FLOORING |
| 74 | Providing andlayingCeramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. |
| 75 | Providing and laying vitrified floor tiles in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 76 | Size of Tile 600x600 mm |
| 77 | Providing and laying Vitrified tiles in floor in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 78 | Glazed Vitrified tiles Matt/Antiskid finish of size |
| 79 | Size of Tile 600 x 600 mm |
| 80 | ProvidingandlayingVitrifiedtilesindiferent sizes (thickness tobe specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 81 | Size of Tile 600x600 mm |
| 82 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 83 | Size of Tile 600x600 mm |
| 84 | Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. |
| 85 | ROOFING |
| 86 | Providing and fixing on wall face unplasticisedRigidPVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 87 | 110 mm diameter |
| 88 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. |
| 89 | Coupler |
| 90 | 110 mm |
| 91 | Single tee with door |
| 92 | 110x110x110 mm |
| 93 | Bend 87.5° |
| 94 | 110 mm bend |
| 95 | Shoe (Plain) |
| 96 | 110 mm Shoe |
| 97 | FINISHING |
| 98 | 12 mm cement plaster of mix: |
| 99 | 1:4(1 cement: 4 fine sand) |
| 100 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement: 3 coarse sand) finished rough with sponge. |
| 101 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 102 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 103 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 104 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture,including applying additional coats wherever required, to achieve even shade and colour. |
| 105 | Two coats |
| 106 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 107 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 108 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping (using wall scraper machine), sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 109 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 110 | One or more coats on old work |
| 111 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade |
| 112 | Old work (Two or more coats applied @ 1.43 V/ 10 sqm) over existing cement paint surface |
| 113 | REPAIRS TO BUILDING |
| 114 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 115 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 116 | Disconnecting damaged overhead/terrace PVC water storage tankof any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. |
| 117 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 118 | Dismantling and Demolishing |
| 119 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 120 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 121 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 122 | Demolishingbrickworkmanually/bymechanicalmeansincluding stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 123 | In cement mortar |
| 124 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 125 | Of area 3 sq. metres and below |
| 126 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : |
| 127 | Of area 3 sq. metres and below |
| 128 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 129 | For thickness of tiles 10 mm to 25 mm |
| 130 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : |
| 131 | 75 to 80 mm dia pipe |
| 132 | 100 mm dia pipe |
| 133 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 134 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer- in-charge. |
| 135 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 136 | ROAD WORK |
| 137 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 138 | Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). |
| 139 | SANITARY INSTALLATIONS |
| 140 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 141 | Kitchen sink with drain board |
| 142 | 510x1040 mm bowl depth 225 mm |
| 143 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 144 | WATER SUPPLY |
| 145 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall |
| 146 | 20 mm nominal dia Pipes |
| 147 | 25 mm nominal dia Pipes |
| 148 | 40 mm nominal dia Pipes |
| 149 | ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 150 | 20 mm nominal dia Pipes |
| 151 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work |
| 152 | DRAINAGE |
| 153 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
| 154 | 150 mm dia. R.C.C. pipe |
| 155 | Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg |
| 156 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: |
| 157 | Inside dimensions 455x610 mm and 45 cm deep for single pipe line : |
| 158 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 159 | Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : |
| 160 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 161 | ALUMINIUM WORK |
| 162 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : |
| 163 | For fixed portion |
| 164 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 165 | Forshuttersofdoors,windows&ventilatorsincluding providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 166 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 167 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 168 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 169 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
| 170 | Upto 5 mm depth and 5 mm width |
| 171 | Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete. |
| 172 | 255 X 19 mm |
| 173 | Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. |
| 174 | Powder coated minimum thickness 50 micron aluminium |
| 175 | WATER PROOFING |
| 176 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 177 | Providingand applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer- in-Charge. |
| 178 | Credit Items (as per Local MR) |
| 179 | Credit value item for selling of old scrapped reinforcement steel/ structural steel/ cast iron pipe on as is where is basis (rate of item will be considered negative). |
| 180 | Buyback of old/existing wooden window of approximate size 1.52 meters x 1.35 meters/ panelled door of size 0.9 x 2.1m) , including wooden frame, shutters, and mild steel (MS) grill. The item includes taking over the removed material in as-is condition from the site. The rate shall include cost of material, loading, transportation, unloading, and all incidental charges complete as directed by the Engineer-in-Charge.(Note: Rate is considered as negative) |
| 181 | Buyback of old/existing wooden windows of various sizes ranging from 0.60 meters x 1.35 meters to 0.90 meters x 1.35 meters, including wooden frames, shutters, and mild steel (MS) grills. The item includes taking over the removed materials in as-is condition from the site. The rate shall include cost of material, loading, transportation, unloading, and all incidental charges complete as directed by the Engineer-in-Charge.(Note: Rate is considered as negative) |
| 182 | SOR Derived Items |
| 183 | Providing and laying backfilling of dry broken brick/AAC block aggregates of 40 mm thick nominal size including spreading and grouting with coarse/fine sand, including finishing smooth etc. complete as per direction of Engineer-in- charge. |
| 184 | Kota stone slab flooring over chajjah with 20 mm (average) thick base and embedding in wall by cutting a chase of appropriate width with chase cutter and embedding the kota stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) as per direction of Engineer-in-charge and finished smooth. |
| 185 | 25 mm thick |
| 186 | Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives. |
| 187 | New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers with elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) or as per per manufacturer specification as directed by Engineer In Charge. |
| 188 | Providing and fixing on terrace (at all floor levels) polyethylene water storagetank,IS : 12701marked,with cover with fitting of CPVC ball valve, CPVC connecting nipple, Brass elbow, Cpvc Elbow, Cpvc Union, brass float valve 25mm andsuitablelocking arrangement with making necessary holes for inlet, outlet and overflow pipesfittings and the base support for tank. |
| 189 | Providing gola 75x75 mm in cement mortar 1:5(1 cement :5 coarse sand ), including finishing complete as Directed by Engineer In Charge. |
| 190 | Providing and fixing machine cut, mirror/ eggshell polished, Granite stone work for door frame/ Window Jambs, sill including dado, skirting, risers of steps etc., in required design and pattern wherever required, atfinished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with cement slurry @ 3.3 kg/sqm including pointing with epoxy grout with pigment of matching shade, including rubbing, curing, moulding and polishing of edges to give high gloss finish all complete as per directed by the Engineer-in-Charge. |
| 191 | Granite Stone of approved shade |
| 192 | Careful removal of existing MS grill from window/ventilator/opening, including repairs such as cutting, welding, straightening of bent members, , grinding, and surface preparation; and refixing the same in original or new position with proper alignment, including fixing with suitable anchoring arrangement complete in all respects with all labour, materials as directed by Engineer In charge. |
| 193 | Fixed to openings /wooden frames with rawl plugs screws/ steel door by welding as required. |
| 194 | NON SOR items |
| 195 | Extra for providing and fixing Galvanised steel ‘base U’ clamps (Ghodi clamp) of approved design for fixing the unplasticised - PVC rain water pipes (or similar work) by means of nail, screwed with M.S. screws of required length, nut bolt, etc. complete as directed by Engineer In-Charge. |
| 196 | For pipe of 75 mm dia |
| 197 | for pipe of 110 mm dia |
| 198 | Extra for providing and fixing Galvanised steel ‘base U’ clamps (Ghodi clamp) of approved design for fixing the unplasticised - PVC or GI water pipes (or similar work) by means of nail, screwed with M.S. screws of required length, nut bolt, etc. complete as directed by Engineer In-Charge. |
| 199 | For 25-50 dia pipe lines |
| 200 | Providing and fixing PVC SWR grade drainage fittings confirming to IS:14735 including fitting with required adhesive/rubber lubricant as per manufacturer\"s specification etc all complete for soil, waste and vent pipes as directed by Engineer In-Charge: |
| 201 | W.C. Connector (Straight) |
| 202 | 110 mm dia |
| 203 | Nahani Trap without Jali |
| 204 | 110 x 75 mm dia |
| 205 | Single \"Y\" with door |
| 206 | 75 mm dia |
| 207 | 110 mm dia |
| 208 | Single \"Y\" |
| 209 | 75 mm dia |
| 210 | 110 mm dia |
| 211 | Single Tee |
| 212 | 75 mm dia |
| 213 | 110 mm dia |
| 214 | Single Tee with door |
| 215 | 75 mm dia |
| 216 | 110 mm dia |
| 217 | Bend 87.5 ﹾ |
| 218 | 75 mm dia |
| 219 | 110 mm dia |
| 220 | Bend 87.5with doorﹾ |
| 221 | 75 mm dia |
| 222 | 110 mm dia |
| 223 | Double \"Y\" |
| 224 | 75 mm dia |
| 225 | 110 mm dia |
| 226 | Reducer \"Y\" with door |
| 227 | 110 mm x 75mm size |
| 228 | Double \"Y\" with door |
| 229 | 75 mm dia |
| 230 | 110 mm dia |
| 231 | Floor Drain Tile |
| 232 | 100 mm |
| 233 | Reducing TEE |
| 234 | 110 x 75 mm size |
| 235 | Reducing TEE with door |
| 236 | 110 x 75 mm size |
| 237 | Bend 45 |
| 238 | Bend 45 ° 75 mm size |
| 239 | Bend 45 ° 110 mm size |
| 240 | NON SOR Item (CSPS SA WORK) |
| 241 | Disconnecting water supply line with clamps and reconnecting with necessasry fitting required including providing and fixing Galvanised steel ‘base U’ clamps (Ghodi clamp) of approved design for fixing the unplasticised - PVC or GI water pipes (or similar work) by means of nail, screwed with M.S. screws of required length, nut bolt, etc. complete at every 3 feet as directed by Engineer In-Charge. |
| 242 | For 25-50 dia pipe lines |
| 243 | Providing and fixing Wall Mixer with provision for Overhead Shower with 115 mm Long Bend Pipe on Upper Side, Connecting Legs & Wall Flanges of approved brand and quality and conforming to IS 8931 and as per directed by Engineer In Charge. |
| 244 | Providing and fixing CP brass Pillar Cock with Extension Body of approved brand and quality and conforming to IS 8931 15 mm nominal diameter as per directed by Engineer In Charge. |
| 245 | Providing and fixing CP brass Angular Stop Cock with Wall Flange of approved brand and quality and conforming to IS 8931 and as per directed by Engineer In Charge. |
| 246 | Providing and fixing CP brass Shower Arm 240 mm Long Round Shape for Wall Mounted Showers with Wall Flangeof approved brand and quality and conforming to IS 8931 and as per directed by Engineer In Charge. |
| 247 | Providing and fixing CP brass Bib Cock with Nozzle of approved brand and quality and conforming to IS 8931 andas per directed by Engineer In Charge. |
| 248 | Providing and fixing Overhead Shower 125 mm dia Round Shape Single Flow (ABS Body Chrome Plated with Gray Face Plate) with Rubit Cleaning System as directed by Engineer In Charge. |
| 249 | Providing and fixing CP Brass Bottle Trap with Fully Casted Body 32 mm with 190 mm and 125 mm Long Connecting Pipes of approvedquality & make and as per the direction of Engineer-in-charge. |
| 250 | providing and fixing SS Waste Coupling Half Thread 40mm for Kitchen Sinks/ Wash basin of approved make as directed by Engineer In Charge. |
| 251 | Providing and fixing CP brass 2-Way Bib Cock with Wall Flange of approved brand and quality and conforming to IS 8931 andas per directed by Engineer In Charge. |
| 252 | Providing and fixing CP brass Sink Cock with Swinging Spout (Wall Mounted Model) with Wall Flange with wall flange of approved brand and quality and conforming to IS 8931 and as per directed by Engineer In Charge |
| 253 | Providing and fixing Wall Hung Cistern with 39mm Drainage L-Bend Pipe with Gasket & Installation Kit of approved brand and quality as Directed by Engineer In Charge. |
| 254 | providing and fixing Hand Shower (Health Faucet) (ABS Body) with 8mm dia, 1 Meter Long Flexible Tube & Wall Hook of approved brand and make as Directed by Engineer In Charge. |
| 255 | Providing and fixing white vitreous china wall mounted water closet of approved size & shape including seat cover, fittings, nuts, bolts and gasket etc all complete as directed by Engineer In-charge. |
| 256 | Providing and fixing white vitreous china over the counter wash basin of size 470mm x 360mm x 130mm of approved brand and manufacturer including making all connections as directed by Engineer In Charge. |
| 257 | Providing and fixing horizontal Chajjah/ Vertical shelves of kota stone in Kitchen Platform/Cupboard shelves 20 to 25 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : |
| 258 | Providing and fixing PVC SWR grade TYPE B drainage integral rubber ring socketed pipes confirming to IS:13592 including fitiing with required adhesive/rubber lubricant (if/as required) as per manufacturer\"s specification etc all complete for soil, waste and vent pipes as directed by Engineer In-Charge.Note: 1) Drainage layout shall be prerpared and got approved by Engineer in charge: based on different socket lengths / fittings available of approved make or manufracturer.2) No extra payment will be made for coupler, reducer, Vent cowl with jali or any small fitting in between the drain lines.Only Special fittings like Tee, Bends, Y will be paid separately. |
| 259 | 75mm dia |
| 260 | 110 mm dia |
| 261 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment with Imidacloprid 30.5% SC (including the cost of chemical emulsion) :Note : Dilution with 2.1ml Imidacloprid 30.5% SC with 1 litre of water or as per manufacturer\"s specification. |
| 262 | Treatment of existing masonry using chemical emulsion as followsa) Drilling 12 mm dia holes at 45 degree with 75 mm depth at interval of 300 mm apart at wall and floor junction Internal as well as External including staircase, landing area.b) Drilling 6 mm dia holes at downward angle of 45 degree with 50 mm depth at interval of 500 mm apart on wood work of window frame, door frame, cupboard frame and wooden work etc. on both faces.c) Injecting chemical emulsion by hand operated pressure pump at minimum 110-120 ml per hole at interval of 30 minutes i.e (350 ml for each hole complete)d) Plugging them with white cement of matching pigment to the full depth of the hole |
| 263 | Making circular holes in masonary walls by core cutting of required size for inserting a rigid pvc pipe of 80 mm dia with end cap including finising with cement mortar (1:4 ; cement : fine sand) and making good walls (matching , touching- painting ) etc all complete as directed by engineer in charge. |
| 264 | providing and fixing Towel rail 600 mm long, CP Brass of approved brand and make as Directed by Engineer In Charge. |
| 265 | PART B: ELECTRICAL WORK WIRING IN STEEL & PVC CONDUIT |
| 266 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable insurface /recessedmediumclassPVCconduit,withmodular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 267 | Group B |
| 268 | Wiringfortwincontrollightpointwith 1.5sq.mmFRLSPVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch,modular plate, suitable GI box and earthing the point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 269 | Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required. |
| 270 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 271 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 272 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 273 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wireinexistingsurface/recessedsteel/PVC conduit including dismantling as required. |
| 274 | Group B |
| 275 | SupplyinganddrawingfollowingsizesofFRLSPVCinsulated copperconductor, singlecorecableintheexistingsurface/ recessed steel/ PVC conduit as required. |
| 276 | 3 x 1.5 sq. mm |
| 277 | 3 x 4 sq. mm |
| 278 | 3 x 6 sq. mm |
| 279 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 280 | 20 mm |
| 281 | 25 mm |
| 282 | Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required. |
| 283 | 5/6 A switch |
| 284 | Supplyingandfixingfollowingsize/modules,GIboxalongwith modular base & cover plate for modular switches in recess etc. as required. |
| 285 | 1 or 2 Module (75mmX75mm) |
| 286 | 3 Module (100mmX75mm) |
| 287 | 4 Module (125mmX75mm) |
| 288 | 6 Module (200mmX75mm) |
| 289 | Supplying and fixing suitable size GI box withmodular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 &15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 290 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 291 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 292 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 293 | Numberingofceilingfan/exhaustfan/fluorescentfittingsas required. |
| 294 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 295 | MCCB, MCB & DB\"S |
| 296 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar,interconnections,powderpaintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 297 | 12 way , Double door |
| 298 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles intheexistingMOBDBcompletewithconnections,testingand commissioning etc. as required. |
| 299 | Single pole |
| 300 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V,residual current circuit breaker (RCCB),having a sensitivity current 30mA inthe existingMCBDBcomplete with connections, testing and commissioning etc. as required. |
| 301 | 40A |
| 302 | Supplying and fixing DP sheet steel enclosure on surface/ recess alongwith 25/32A240V\"C\"curveDPMCBcompletewith connections, testing and commissioning etc. as required. |
| 303 | EARTHING |
| 304 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate havinglocking arrangement and wateringpipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 305 | Supplying andlaying 25 mm X 5 mm copper strip at 0.50 metre belowground asstrip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 306 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 307 | Providingandfixing4.00mmdiacopper wireonsurfaceorin recess for loop earthing as required. |
| 308 | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. |
| 309 | BLDC |
| 310 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLOC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 311 | Non-Schedule/MR |
| 312 | Supplying & Fixing of 300 mm sweep metal body exhaust fan, HEAVY duty,, 230 Volts, 50Hz,1400 RPM single phase A.C.supply andmounting frame on teak wooden frame 19 mm thiknes, complete including making the hole in wall and refinished it with testing,commissioning etc. as reqd. \"Marathon\" Make |
| 313 | LED Batten light (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K/4000°K /5700°K /6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3. Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120<135 Im/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). CRCA sheet Body (thiness ≥ 0.50 mm) 18-22Watt |
| 314 | Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel board necessary IP-42 and above protection as per approval from engineer incharge made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary accesories supporting angles/ flats channel including cutting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with erection ofsupplied switch gears, BUSBARS, suitable size of inter connecting PVC copper wire/copper-aluminium strips, rubber grommets, rib, bakelite control fuses/MCB for measuring instruments, earth bus & earth bolts, foundation flange bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket, heavy duty end terminal notice connection, danger board, necessary ventilation, earthing strip complete. The Panel shall be painted with epoxy powder coating.(The rates excludes the cost of switchgears, bus bars, inter connecting mains & Copper Aluminium strips, meters, Fuses etc. The dimension shall be measured excluding base beams) The panel shall be supplied with following approved manufacturers with following size.(A) locally fabricated panel board(1) with 350 mm depth |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail