| 1 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) a) For Exposed Work PVC Pipes- 150mm |
| 2 | Supply and fixing of PVC ball valve with suitable clamp and other fixing accessories- 150mm |
| 3 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) a) For Exposed Work PVC Pipes- 100mm |
| 4 | Supply and fixing of PVC ball valve with suitable clamp and other fixing accessories- 100mm |
| 5 | Providing andfixingscaffolding system onthe exteriorside,up tofive storyheightmade with Bamboo centre to centre horizontal & vertical joining with coir rope and also providing workingplatformetc.and maintaining itinaserviceableconditionfortherequiredduration as approvedand removingitthere after.The scaffolding systemshallbe stiffenedwithbracings,runners,connectionwiththebuildingetc whereverrequiredforinspectionofworkatrequiredlocationswith essentialsafetyfeaturesforthe workmenetc.complete asper directionsandapprovalofEngineer-in-charge .Theelevationalareaof thescaffolding shall bemeasuredforpaymentpurpose.Thepayment will be made once irrespective of duration of scaffolding. |
| 6 | Supply of following sizes of 1.1 kV grade multicore aluminium conductor XLPE sheathed armoured cable as per IS 7098 (Part -1) 1988 |
| 7 | 3 Core 10 Sq. mm. |
| 8 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 9 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 10 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
| 11 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 12 | Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 13 | 3 X 10 sq. mm (22mm) |
| 14 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 15 | Supply, Installation, Testing and Commissioning of Axial Flow Fan. |
| 16 | 12\"\" (300 mm) 0.5 HP , 2850 rpm, 230V AC Air delivery 2000 cfm at 30mm static pressure (air delivery at free intake and delivery 2700 cfm). (EPC) |
| 17 | 10\"\" (250 mm) 0.25 HP , 2850 rpm, 230 V AC Air delivery 900 cfm at 20 mm static pressure (air delivery at free intake and delivery 1500 cfm). (EPC) |
| 18 | Supply, Installation, Testing and Commissioning of outdoor type Powder coated MS protection mounting Box with vent for 12\"\" Axial flow fan including all components and mounting accessories as per site requirement. |
| 19 | Supply, Installation, Testing and Commissioning of outdoor type Powder coated MS protection mounting Box with vent for 10\"\" Axial flow fanincluding all components and mounting accessories as per site requirement |
| 20 | Supply, Installation, Testing and Commissioning of single phase AC timer and controller/regulator suitable for controlling 2 nos. 12\"\"/10\"\" axial flow fan inpowder coated MS encloser box (Outdoor type & size is equivalent to 4 way TPN DB)) with DIN rail on surface with following major electrical accessories with all necessary wiringsand making connections as per direction of EIC.1. 25 A, 2 Pole contactor -2 nos.2. Digital / Analog time switch - 2nos. 3. 25A DP MCB (10 kA,C Curve)-2 nos.4. Speed Regulator- 2 nos.5. Other necessary accesories and wirings as required. |
| 21 | Supply, Installation, Testing and Commissioning of single phase AC timer and controller/regulator suitable for controlling 1 no. 12\"\"/10\"\" axial flow fan inpowder coated MS encloser box ( size is equivalent to 8 way SPN DB) with DIN rail on surface with following major electrical accessories with all necessary wiringsand making connections as per direction of EIC.1. 25 A, 2 Pole contactor -1 no.2. Digital / Analog time switch - 1 no. 3. 25A DP MCB (10 kA,C Curve)-1 no.4. Speed Regulator- 1 no.5. Other necessary accesories and wirings as required. |