| 1 | Disconnecting/taking down defective fluorescent tube light/HPSV/MH/HPMV/ LEDflood lights/street light street light fittings for repair by replacement of worn out accessories from pole up to 11 mtr and refixing the same after repair complete all as specified and directed. Note:- (i) Spare parts shall be measured and paid separately under respective item of BOQ as \"supply only\".(ii) All T&P and safety measures required shall deem included in quoted unit rate. |
| 2 | Disconnecting and taking down High mast light up to 25 Mtr Height including taking down mast assembly,refixing & repositing of the same after repairingcomplete all as specified and directed.Note:- (i) Spare parts shall be measured and paid separately under respective item of BOQ as \"supply only\".(ii) All T&P and safety measures required shall deem included in quoted unit rate. |
| 3 | S & F in repair MS flat iron clamps, nut bolt of existingsize for bracket on pole complete all as specified and directed. |
| 4 | S & F in replacement GI pipe 40 mm bore light gradebent to the shape of bracket 1.2 Mtr in length for mounting of street light fitting and fixed on pole with clamp and nut, bolt and washerwith two coat anti corrosive enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 5 | Supply only following items/materials for replacement to repair FTL/HVSV/MH/HPMV/LED flood light/street light under item No 01 & 02 here in before.Note:- (i) Labour component for taking out burned part including dismantling of street light any description and replaced with new one is included in item No. 01 & 02 here in before. (ii) No item shall be taken from Contractor for MES storethrough receipt voucher (RV) |
| 6 | Constant current LED driver as per existing make suitable for flood light fitting 240/200 watt complete all as specified and directed. |
| 7 | Constant current LED driver suitable forflood lightfitting 150 watt complete all as specified and directed. |
| 8 | Constant current LED driver as per existing make at site suitable for street light fitting 90 watt complete all as specified and directed. |
| 9 | Constant current LED driver as per existing make suitable for street light fitting 70/72/80 watt complete all as specified and directed. |
| 10 | Constant current LED driver as per existing make at site suitable forstreet light fitting 60 watt complete all as specified and directed. |
| 11 | Constant current LED driver as per existing make at site suitable forstreet light fitting45 watt complete all as specified and directed. |
| 12 | LED panelas per existing make at site suitable forstreet light fitting 90 watt complete all as specified and directed. |
| 13 | Panelas per existing make at site suitable forstreet light fitting 70/72/80 watt complete all as specified and directed. |
| 14 | LED panelas per existing make at site suitable forstreet light fitting 60 watt complete all as specified and directed. |
| 15 | LED panelas per existing make at site suitable forstreet light fitting 45 watt complete all as specified and directed. |
| 16 | LED panel as per existing make at site suitable forflood light fitting 150 watt complete all as specified and directed. |
| 17 | LED panel as per existing make at site suitable forflood light fitting 200/240 watt complete all as specified and directed. |
| 18 | SPD suitable street light/flood light of any wattage suitable for existing fitting at site complete all as specified and directed. |
| 19 | S&F in replacement of 150 watt LED flood light fittings having long life of high power LED with SMD LED exclusive innovative dia cast aluminium IP-66 built in IP-67 electronic driver with APFC, lower THD, open circuit protection, over voltage protection, surge protection up to 10KV with built in SPD & other safety as per IS-15885 part -2 ,Sec 13, IEC 60598-1 of operating voltage 140-270V avg life 50,000 hours complete manufacture prove all test certificate as per protection for minimum 2 years from manufacturing companies complete all as specified and directed. |
| 20 | All as per item No. 6 above but 200 watt LED flood light |
| 21 | Supply and fixing in repalcement of LEDStreet Light fixture of 90W with IP-66 protected die-cast aluminium housing and heat resistive toughened glass. LED shall be having LM-79 and LM-80 complied as per L-70 standard. LEDs should be tested for minimum 10,000 burning hours with 5700-6000 K CCT.Maximum power consumption shall not exceed 90W and system lumens shall not be less than 9,000. Optics shall be properly designed with Polycarbonate Lenses to avoid dark patches on the road. Street light without lenses will not be acceptable. Driver shall be 3 stage \"Constant Current Constant Voltage\" with voltage range of 150-270V AC. Output voltage of driver should be complied to Safety Extra Low Voltage norms not exceeding 60 V DC.Note:-(i) The item rate shall deem to include provision of weather proof PVC insulated aluminium conductor cable 2.5 Sqmm, 2 core as required.(ii) LEDs used in the product shall comply with EN-62471 for photo - biological safety and certificate for the same from manufacturer shall be provided.Luminaire manufacturer shall produce certificate of association with LED manufacturer for minimum two years. |
| 22 | All as per item No. 8 above but LEDStreet Light fixture of 70W |
| 23 | Supply and fixing in replacement of timer switch for street lights control for 3 KW Single Phase rating consists of the following items :- (a) Swadeep-02EC-3KW1P(b) contactor AC3 25 Amps - 01 No (c) Incoming MCB of 25 Amps - 01 No(d) Outgoing MCB of 25 Amps - 01 No(e) complete single phase circuit wiring |
| 24 | Supply and fixing in replacement of timer switch for street lights control for 5 KW three Phaserating consists of the following items :- (a) Swadeep-02EC-5KW3P(b) contactorAC3 16 Amps per phase - 03 No (c) Incoming MCB of 20 Amps - 01 No(d) Outgoing MCB of 20 Amps - 01 No(e) complete single phase circuit wiring |
| 25 | M&L for 10 Sqmm 2 core 1100V solidaluminium conductor, unsheathed PVC insulated cable including taking down old unserviceable existing cable complete all as specified and directed.Note:- Excavation, earth work, sand filling and cable cover shall be measured and paid separately under respective item of BOQ. |
| 26 | All as per item No. 12 above but cable of size 2.5 Sqmm size. |
| 27 | M&L for Supply, laying, connecting and testingXLPE insulated armoured heavy duty aluminium conductor electric cable, 1100 Volt grade, 35 Sqmm 3.5core complete all as specified and directed. |
| 28 | All as above item no 14 but 16 sqmm 4 core cable. |
| 29 | All as above item no 14 but 10 sqmm 4 core cable. |
| 30 | All as above item no 14 but 10 sqmm 2 core cable. |
| 31 | Excavation in trenches in soft/ loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth (for laying of cables/pole/ foundation etc) and getting outcomplete all as specified and directed. |
| 32 | Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cmapart complete all as specified and directed. |
| 33 | Removing surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtrs above the starting point complete all as specified and directed. |
| 34 | M&L for sand cushioning with a layer of sand 80mm thickbefore laying of cable and 150mm thick after laying of cable in trenches complete all as specified and directed.Note:- Punned thickness of 180mm shall be measured for payment purpose. |
| 35 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250mm x 150mm x 40mm complete all as specified and directed. |
| 36 | S&F in repair junction box of size not less than 12\"x10\"x4\" Triple Pole and neutral (TPN) enclosure compression gland2with connector and clamp for pole mounting with two nos of nut bolt and washers and socket complete all as specified and directed. |
| 37 | All as per item No. 23 above but SPN junction box. |
| 38 | S&F in repair galvanised iron pipe light grade 40 mm dia (ISI marked) with all fittings laid in trenches or on pole, crossing of road,fixed on wall for protection of cables complete all as specified and directed |
| 39 | S&F in repair timer analog time watch FM/1 quartz 16A 250ACsuitable for high mast panel complete all as specified and directed. |
| 40 | S&F in repair auxiliary contactor MNX-A2 415V 10A suitable for high mast panel complete all as specified and directed. |
| 41 | S&F in repair lower raising push botton no NC auxiliary contactor MNX-A2 415V 10A suitable for high mast panel complete all as specified and directed. |
| 42 | S&F in repair one/two way connector suitablefor high mast panel/street light connectioncomplete all as specified and directed. |
| 43 | S&F in repairflexible copper flat cable of size 2.5 sqmm 5 core, 1100 volt grading complete all as specified and directed. |
| 44 | S&F in repair flexible copper flat cable of size 1.5 sqmm 3 core, 1100 volt grading complete all as specified and directed. |
| 45 | M&L repair chain pully motor & greasing chain pully of high mast light complete all as specified and directed. |
| 46 | S&F MCB SPN 240 volt 40 to 63 Amp10 KA capacity having C-curve characteristics complete all as specified and directed. |
| 47 | S&F MCB SP 240 volt 6 Amp to 40 Amp 10 KA capacity having C-curve characteristicscomplete all as specified and directed. |
| 48 | M&L for cleaning of site including cutting of vegetation surrounding transformer, two poles, four pole structure at various sub station / E&M installation and remove the rubbish/bushes to a distance not exc 50 mtr complete all as specified and directed. |
| 49 | M&L for cutting /trimming of tree branches upto 80 mm girth along LT/HT OH electric lines which are growing /touching or falling on ACSR conductor /poles or near by sub stns etc at any height from GL and making sufficient clearance (not less than 1.5 mtr) from ACSR conductor/ poles/ structure carefully avoiding any damages to the line and removing the brushes/ tree branches from site complete all as specified and directed.Note :- All T&P and safety measures shall be arranged/provided by the Contractor and cost of the same shall deemed to be included in the quoted unit rate. |