| 1 | Dismantling of AC/GI plain/Corrugated / semi corrugated roof sheets any type and any size complete all as specified and directed. |
| 2 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and directed. |
| 3 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed by Engineer-in-Charge. |
| 4 | S&F Mild steel workin tubular poles & trusses (framed) including purlins,rafters and special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS-1161-1979 grade St-240 complete all as specified and as directed by Engineer-in-Charge. |
| 5 | S & F steel Fe-410-W (Gde 250 Quality-A) work in tubular stanchion/postincluding special shaped washer etc. complete using one of more tubes or induction butt welded tubes conforming to IS-1161- 1979 grade St.-240 complete all as specified and directed. |
| 6 | S&F mild steel work Fe-410-W (Gde 250 Quality-A) in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachmentcomplete all as specified and as directed by Engineer-in-Charge. |
| 7 | M&L for MS Framed work of Fe 410 W (Gde-E-250) Quality A, as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete |
| 8 | M&L for preparationof new/old or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 9 | Excavation in post holes (or similar holes) each n exc. 0.5cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layer n.exc. 25cm complete all as specified |
| 10 | Demolition of reinforced cement concrete of any description and in any position such as in RCC post or in RCC walls below or above ground floor complete all as specified and directed. |
| 11 | Providing reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area n exc 100 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed |
| 12 | M&L for Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:4 complete all as specified and directed. |
| 13 | M&L Hard core of gauge n.exc 63 mm, deposited, spread, levelled in layers not exc 15 cm thick, watered and well rammed to a true surface. |
| 14 | Moorum / Red bajri filling in floors or pavings, laid in layers n.exc15 cm thick spread levelled and rammed incl watering etcall as specified & directed. |
| 15 | Demolition of cement concrete unreinforced in ground floor and paving not exc 15cm thick (below or above ground level) complete all as specified and directed. |
| 16 | M & L P:C:C 1:4:8 Type D2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 17 | M&L for 100 mm thick Cement concrete 1:4:8type D-2using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 18 | M&L for 100 mm thick Cement concrete 1:2:4type B-1using 20 mm graded stone aggregate as in flooring incl finished cement concrete surface even and smooth with extra cement complete all as specified and directed. |
| 19 | M&L for 50 mm thick Cement concrete 1:2:4type B-1using 20 mm graded stone aggregate as in flooring incl finished cement concrete surface even and smooth complete all as specified and directed. |
| 20 | M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in surface channels and drains complete all as specified and directed. |
| 21 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed. |
| 22 | M&L forPrepolished Chequered cement concrete tiles of size 200 mm x 200 mm x 25 mm thick set jointed and pointed in neat cement slurry in floor and cut and polished with grey cement and pigment, including 20 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 23 | Providing and laying 60mm thick factory made chamfered edge Pre polished cement concrete interlocking paver block of M-35 grade with approved colour,design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified. |
| 24 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 25 | M&L old size Brick work using fly ash bricks straightor curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 26 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick workor concrete surfaceof walland to be finished even and smooth with out using extra cement complete all as specified and directed |
| 27 | M&L for rendering 15mm thick in CM 1:6 on other than fair faces of brick workor concrete surfaceof walland to be finished even and smooth with out using extra cement complete all as specified and directed |
| 28 | M&L TMT bar 10 mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips ,complete all as specified and directed. |
| 29 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 10cm and n exc 15cm long and dia of neck 11 mm to 15 mm ,complete all as specified and directed. |
| 30 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 31 | Dismantling fencing wire mesh any size or type,and removing the site complete all speciified and directed |
| 32 | S&F PVC insulated chain link fencing including line wire of size 3.15 mm dia and 100x100 mm mesh made up in mattresses or cases, lapped wire and laid in position to RCC fenccing and straining and fixing to any type of posts, straining bolts, standard bolt, incl securing or tying at crossing with and including provision of galvanized mild steel wire sraples or steel pins etc complete all as specified and directed (each line of wire to be measured for the purpose of payment) |
| 33 | S&F Flat Iron strip 40 mm x 6 mm for securing chain link fencing with RCC posts incl drilling holes, notching for wire etc.for inserting bolts incl all necessary drilling, bolting or riveting etc. complete |
| 34 | M&L fortwo coats of white wash on previously untreated (new)/old surface of RCC posts or bk wall incl preparation of surface complete |
| 35 | M&L for Preparation of old surfaces of Wall and applying One coat of white wash over old decorated surface of wallsall as specified and directed by Engineer-in-Charge. |
| 36 | M&L for preparation of old distempered surfaces of walls and applying one coat of oil bound distemper on walls all as specified and directed. |
| 37 | M&L for Preparation of old surfaces of Wall and applying one coat of Cement Base Paint on wallsall as specified and directed by Engineer-in-Charge. |
| 38 | M&L for preparing old plastered surfaces of walls, Facias, cornices etc and apply one coat of weather proof exterior emultion (Make as approved by GE) Complete all as specified and directed. |
| 39 | M&L for preparation of old plastered surfaces of ceilings and apply one coat of white wash complete all as specified and directed. |
| 40 | M&L for preparation of old painted surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply one coat of synthetic enamel paint complete all as specified and directed. |
| 41 | M&L for Preparation of Newly Plastered surfaces of Wall and applying Two coats of Oil Bound Distemper over a coat of primer all as specified and directed. |
| 42 | M&L for Preparation of Newly Plastered surfaces of Wall and applying Two coats of White Wash all as specified and directed. |
| 43 | Dismantling post or struts embedded in concrete, brick work, masonry etc (wood, steel or R.C.C) any section, including taking out embeded portion and making good disturbed ground. |
| 44 | Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr depth and getting out in looses/soft soil complete all as specified |
| 45 | Returing filling in incl spreading leveling, watering and well ramming in layer not less than 25 cum each layer all as specified. |
| 46 | Removing excavated material to a distance not exc 50M anddepositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified |
| 47 | M&L Checking /finding out or locating fault of existingLT UG cable laid inunder ground /on poles/ walls or any situvations or location inside Gopalpur Mil stationup to Vijaya dhar gate and restoring power supply within 4 Hrs period after receiving the call/ Msgfrom concerned JE E/M or in chain of command.The job includes excavation,Earth work, returning filling and removal, Meggaring /insulation resistance checking ,intermittant jointing of existing cables with new cableswith proper LT straighjt through joints etc to restore power supply in all respect including cutting of road path and making good etc all as directed. Note:- 1:- Excavation / earth work,new cable,cable protection pipes, re laying of existing cable, LT cable joints,JB boxes, clamps, Brackets,filling of PCC will be measured and paid seperately.Note ;- 2 :- If the fault not rectified in the specified time limit double the rate of job as penality will be debited to contr.(3) Break down will be attended any time round the clock including sunday/ holidays and any weather conditions,(4) Excavation more than 5 cum only will be measured and paid seperately |
| 48 | Supply and laying double wall corrugated (DWC) HDPE pipe 50 mm outer dia for protection of UG cable as per IS: 16205 (part 24) of 2017 complete all as specified. |
| 49 | Supply and laying double wall corrugated (DWC) HDPE pipe 63 mm outer dia for protection of UG cable as per IS: 16205 (part 24) of 2017 complete all as specified. |
| 50 | Supply and laying double wall corrugated (DWC) HDPE pipe 90 mm outer dia for protection of UG cable as per IS: 16205 (part 24) of 2017 complete all as specified |
| 51 | M&L PCC 1:4:8 type D 2 using 40 mm graded stone aggregate for fillingof pole & stay complete all as directed |
| 52 | M&L PCC 1:3:6 type C 2 using 40 mm graded stone aggregate for fillingof pole & stay complete all as directed |
| 53 | M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for copining of pole complete all as directed |
| 54 | M & Lfortubelightgrade galvanisedwithallfittingslaidalong the pole/intrenches / underroadorfloorof50mmbore including removing the rusted old one completeallasspecifiedanddirected. |
| 55 | M & Lfortubelightgrade galvanisedwithallfittingslaidalong the pole/intrenches / underroadorfloorof80mmbore including removing the rusted old one completeallasspecifiedanddirected. |
| 56 | M & Lfortubelightgrade galvanisedwithallfittingslaidalong the pole/intrenches / underroadorfloorof100mmbore including removing the rusted old one completeallasspecifiedanddirected. |
| 57 | Taking out old unserviceable PCC/steel tubularpole 9 mtrs long and supply and fixing steel tubular swaged poles with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and erecting in position all as specified and directed with shifting of conductors and insulators including painting the exposed portion with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer with and including marking of pole number with black paint in yellow circle, complete, all as specified and directed. |
| 58 | Taking out old usserviceable PCC pole of any size and supply and fixing in repairs Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and l02mm x 279mm at bottom, class 10 and erecting in position all as specified and directed with shifting of conductors and insulators including painting the exposed portion with two coats of weather proof paint complete, all as specified and directed. |
| 59 | S & F in replacement of Cross arm, bracings, supports , clamps and back plate fabricated from structural steel section, including nut , bolts , washers, welding , bendings cold or hot, drilling hole for both in any shape or size as indicated or directed and inclusive of one prime coat, one under coat and one finishing coat of paint incl taking down the old unserviceable cross arms complete all as directed. |
| 60 | M & L stay assembly complete with accessories as shown in electrical plate No 1 (Loop type insulator, stay clamps, excavation and concrete only measured separately) using diameter of stay rod 16 mm and MS stay plate 230mm x 230mm including taking down complete all as directed. |
| 61 | Supply and fix in replacement of loop type insulator vitreous white,brown or green insulator small size,with over all dimensions 65 x 90 mm,clearance of hole 16 mm complete all as directed. |
| 62 | M&L Supply, laying, jointing and testing ofXLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts gradewith aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for 10Sqmm 2 core , complete all as specified and directed . |
| 63 | All as per item no. 62 but for25 Sqmm 3.5 Core. |
| 64 | All as per item no. 62 but for35 Sqmm 3.5 Core |
| 65 | All as per item no. 62 but for50 Sqmm 3.5 Core |
| 66 | All as per item no. 62 but for70 Sqmm 3.5 Core |
| 67 | All as per item no. 62 but for240 Sqmm 3.5 Core |
| 68 | M/L for replacement of Earthing complete with GI earthplate 60x60cmx6mm thick electrode and using galvanised iron strip 32 x 6 mm as earthing lead burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI strip 32x6mmby means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia med grade,funnel,wire mesh,protection pipe 40 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point all as specified and as directed by Engr-in-charge. |
| 69 | Supply and fixing of moulded case circuit breaker Four pole 63/100 Amps 16 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 70 | Supply and fixing of moulded case circuit breaker Four pole 125 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 71 | Supply and fixing of moulded case circuit breaker Four pole 160 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 72 | Supply and fixing of moulded case circuit breaker Four pole 200 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 73 | Supply and fixing of moulded case circuit breaker Four pole 250 Amps 36 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 74 | Supply and fixing of moulded case circuit breaker Four pole 315 Amps 36 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 75 | Supply and fixing of moulded case circuit breaker Four pole 400 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 76 | Supply and fixing of digital voltmeter 0 to 500 volts 96 x96mm flush type in LT Panels incl taking out the old unserviceable complete allasspecifiedanddirected. |
| 77 | Supply and fixing of digital ammeter range as per existing 96 x96mm flush type in LT panels incl taking out the old unserviceable complete allasspecifiedanddirected. |
| 78 | Supply and fixing of LT current transformer ratio from 200/5 Ampsor 100/5 or 400/5 in LT panels incl taking out the old unserviceable complete allasspecifiedanddirected. |
| 79 | Supply and fixingselector switch of voltmeter/ammeter in LT panel boards incl taking out the old unserviceable complete allasspecifiedanddirected. |
| 80 | Supply and fixing indicator assembly (RYB) LED type in LT panel boards incl taking out the old unserviceable complete allasspecifiedanddirected. |
| 81 | M&L for painting steel tubular/RS joist pole 9 mtrs long alongwith bends with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer with and including marking of pole number with black paint in yellow circle, complete, all as specified and directed. |
| 82 | M&L for painting PCCpole 9 mtrs long alongwith bends with two coats of weather proof paint and two coats of black bituminous paint over a coat and including marking of pole number with black paint in yellow circle, complete all as specified and directed. |
| 83 | M&L for painting to LT panels of any size with two coats of synthetic enamelpaint of approved colour over a coat of red oxide primer outerside andinternally complete Job including removing rust and dust and repair to worn out portion and denting etccomplete all as specified and directed by Engr- in-Charge. Note: 1. Before painting the contractor will ask for a shut down of the recpective feeder from the JE.2. While painting of the panels protection of MCCB\"s and MCB\"s to be taken care of by the contractor.Any damage occured during the painting will be bear by the contractor. |
| 84 | S&F of Cable jointing kit for 1.1 KV (Earthed)grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 2 core XLPE armoured aluminium conductor cable of size 10-16 sqmm , complete all as specified and directed. |
| 85 | S&F of Cable jointing kit for 1.1 KV (Earthed)grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 25-50 sqmm , complete all as specified and directed. |
| 86 | S&F of Cable jointing kit for 1.1 KV (Earthed)grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm , complete all as specified and directed. |
| 87 | S&F of Cable jointing kit for 1.1 KV (Earthed)grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 150 to 185 sqmm , complete all as specified and directed. |
| 88 | Boring of holes horizontally for laying of 80mmdia pipe (minimum depth 0.60 Mtr from top level) under road, Pavement, hard standing complete all as specified and directed. |
| 89 | Supply and fixing Aluminium tube terminal/ lugs of undermentioned10 to 25 Sqmm complete all as specified and directed. |
| 90 | All as per item no. 89 but for35 to 50 Sqmm |
| 91 | All as per item no. 89 but for70 to 120 Sqmm |
| 92 | All as per item no. 89 but for150 to 185 Sqmm |
| 93 | All as per item no. 89 but for240 to 300 Sqmm |
| 94 | supply only PVC Electricalinsulation self adhesive tape 1.8cmx7mx0.125mmfor Red, Yellow, Blue & Green all as specified and directed |
| 95 | Supply, fabricate, erect, test and commission in replacement outdoor LT MS Feeder pillar box totally enclosed weather and vermin proof, suitable verntilated, 440 Volts, 50 HZ, AC Supply, factory made standard design as per electrical requirements to suit power distr sys , enclosure fabricated out of 3.00 mm thick MS sheet, excavation and earth work, PCC foundation etc,with hinged doors and lcoking arrangemetn , air vents, tappered roof, incoming and outgoing cable connections from bottom with compressed cable gland etcas required with and including the following, supplied fitted and connected internally complete04 Nos aluminiumbus bar of size 50 x 10 mm with PVC coloured heat srinkable type sleeves continous phase rating 400 Amps rating mounted on non cracting resin type insulators complete all as specified |
| 96 | S & F in replacement of old UNSV. Cable loop box with SMC Junction box shock and rust proof , rot/termite resistance, tamper proof, with necessary pole mounting arrangements FR type ( (270mm x 225mm x 135mm) with in-built /housed terminal for 04 pole wire termination and 6AMCB din-rail mounted , hinged door with locking arrangements incl necessary Galvanised iron clamps, bolts/nuts suitable to hold/accommodate to the exisitng pole(any type)/ bldg etc by removing the exisiting electrical connections and reconnecting back the same cable complete all as specified & directed . |
| 97 | S&F in repair/ repalcement of on load change over switches 4 pole 160A in open execution, 415 volts, 50 Hz complete all as specified and directed. |
| 98 | S&F in repair/ repalcement of on load change over switches 4 pole 200A in open execution, 415 volts, 50 Hz complete all as specified and directed. |
| 99 | S&F in repair/ repalcement of on load change over switches 4 pole 250Aamp in open execution, 415 volts, 50 Hz complete all as specified and directed. |
| 100 | S&F in repair/ repalcement of on load change over switches 4 pole 400Amp in open execution, 415 volts, 50 Hz complete all as specified and directed. |
| 101 | S&F in repairs Aluminium strip 32x6 mmwith saddles and fixing screws etc. for roofconductors and down conductors above ground. |
| 102 | S&F in repairs Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specifed and directed. |
| 103 | M&L for in repairs Aluminium conductor, steel reinforced, to stringe against the old unsv overhead conductor of suitable size with keep proper sag as applicable complete all as specified and directed. |
| 104 | M & L for earth continuity conductor using GI strip 32 x 6 mm galvanised iron strip complete all as directed incl taking down the old unserviceable complete. |
| 105 | S&F in repairs HRFR PVC insulated industrial cabled single core copper conductor, 1100 volts conforming to IS 694 of size 16 Sqmm complete all as specified and directed |
| 106 | S&F in repairs HRFR PVC insulated industrial cabled single core copper conductor, 1100 volts conforming to IS 694 of size 10 Sqmm complete all as specified and directed |
| 107 | S&F in repairs aluminium busbar of suitable size as per exisiting on ground and removing the old burnt one from LT panel with complete connection of existing cables all as specified and directed. |
| 108 | M&L for attending day to day breakdown complaints of any nature in low tension line round the clock time after receiving the complaint from complaint cell/ JE concerned and rectifying the same as soon as possible complete all as specified and directed. |
| 109 | Supply and fixing in repairs SP 5-32 amp rating 240V, 10KA \"C\" curveminiature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 110 | Supply and fixing in repairs SPN 32-40 amp rating 240V, 10KA \"C\" curveminiature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 111 | Supply and fixing in repairs TPN 40-100 rating 415, 10KA \"C\" curveminiature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 112 | Taking out old UNSVXLPE/PVC insulated, armoured, heavy duty LT under ground cable 1100 Volts gradewith aluminium conductor fromtrenches, from poles/walls etc cross sectional area for 10 Sqmm to 16 sqmm 4 / 2 Core ,complete all as specified and directed . |
| 113 | All as per item no. 112 but for25to 50 Sqmm 3.5 Core/4 core. |
| 114 | All as per item no. 112 but for70 to 240 Sqmm 3.5 Core/4 core. |
| 115 | Relaying of serviceable U/G cable retrived from site of size 10 to 16 sqmm 2/4 core ,complete all as specified and directed( Cable protection pipe /sand brick,jointing kit,cable lugs etc will be measured and paid seperately) |
| 116 | Relaying of serviceable U/G cable retrived from site of size 25 to 35 sqmm 2/3.5/4 core ,complete all as specified and directed( Cable protection pipe /sand brick,jointing kit, cable lugs,etc will be measured and paid seperately) |
| 117 | Relaying of serviceable U/G cable retrived from site of size 70 to 240 sqmm 2/3.5/4 core ,complete all as specified and directed( Cable protection pipe /sand brick,jointing kit, cable lugs etc will be measured and paid seperately) |