| Sl. No. | Item Description |
| 1 | Demolition of brick/stone masonry work built in cement mortar as in wall including all quoins, arches, pillars etc and removal of debris outside MoD land complete all as specified and directed. |
| 2 | Brick work with with old size fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 3 | Brick work with with old size fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed. |
| 4 | Demolition of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets and hanging frameworkand removal of debris outside MoD land complete all as specified and directed. |
| 5 | Providing and fixing false ceiling at all the heights with GRG (Glass fibre Reinforced Gypsum) false ceiling tiles with semi perforated 12mm thick micro tegular edged of size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99%, NRC 0.50 20.75 as per IS 8225: 1987, non combustible as per BS 476 (Part 4) -1970 and light reflectance of 85% ( minimum) to be laid into horizontal level suspended on inter locking metal T - Grid of hot dipped galvanised iron sec of 0.33 mm thick (galvanised @ 120 gms per sqm including both sides) comprising the main T runners of size 15 x 32 mm of length 3000mm, cross T of size 15 x 32 mm of length 1200 mm and secondary intermediate cross T of size 15 x 32 mm of length 600 mm to form grid module of size 600 x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i e 50mm long, 8mm outer diameter M-6 dash fastners 6mm dia fully threded hanger rod upto 1000mm length and L shape level adjuster of size 85 x 25 x 2 mm.Galvanised iron perimeter wall angle of size 24 x 24x 0.40mm of length 3000mm to be fixed on peripheri wall / partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dirve wall wood screws complete all as specified, shown on drawings and directed. |
| 6 | Taking down cement plaster / terrazo finish on brick wall including racking out joints, hacking for key scrubbing down with water, etc. and removal of debris outside MoD land complete all as specified and directed. |
| 7 | Rendering 10mm thick on fair facesof brick work or concrete surfacesin cement mortar 1:6 finished even & smooth without using extra cement all as specified and directed. |
| 8 | Preparation of newly palstered surface of walls and applying one coat of alkali resistant primer over a coat of birla white cement putty, sanding the surfaces to smooth finishand finally applying two coat of oil emulsion distemper complete all as specified and directed. |
| 9 | Rendering 15mm thick plaster on fair faces of brick walls or concrete surfaces intwo layers i.e. 10mm in cement mortar 1:6 and 5mm in cement mortar 1:4 mixed with approved WPC as per manufacturer\"s instructions in 5mm layer only and finished fair & even without using extra cement, complete all as specified and directed.Note:- WPC shall be measured and paid for separately. |
| 10 | Supply only integral liquid water proofing compound, ISI marked complete all as specified and directed. |
| 11 | Preparation of new plastered or un-plastered surfaces of walls including cornices, pillasters etcand applying two coats of weather proof exterior emulsion over a coat of alkali resistence primer complete all as specified and as directed. |
| 12 | Rendering 5 mm thick on ceiling in cement mortar 1:3 on fair faces of brick work or concrete surfaces and finishing the surface even and smooth complete all as specified and directed. |
| 13 | Preparation of new plastered ceiling surfaces and applying two coats of white washcomplete all as specified and directed. |
| 14 | Preparation of old decorated plastered surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applying one coat of distemper oil emulsioncomplete all as specified and directed. |
| 15 | Dismantling floor or wall tiles including cement mortar bedding,and removal of debris outside MoD land complete all as specified and directed. |
| 16 | Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thick, above or below ground level and removal of debris outside MoD land complete all as specified and directed. |
| 17 | 25 mm thick cement concrete 1:2:4 type B–0 using 12.5mm graded stone aggregate in flooring, finished even and rough to receive topping layer complete all as specified and directed. |
| 18 | All as per Srl item No. 17 here-in-before but 40 mm thick. |
| 19 | Glazed ceramic coloured tiles 7mm thick 300 x 450mm size on vertical surface, set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 10mm thick rendering in cement mortar (1:3) complete all as specified and directed. |
| 20 | Double charged vitrified ceramic light shade coloured tiles with matt finish, 8-9 mm thick (square/rectangular), polished, area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc., set andjointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15mm thick screed bed in cement mortar (1:4)complete all as specified and directed. |
| 21 | All as per Srl item No. 20 here-in-before but 10 mm thick tiles, area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm. |
| 22 | All as per Srl item No. 20 here-in-before but on vertical surface such as skirting, dado over and including 10mm thick rendering in cement mortar (1:3). |
| 23 | All as per Srl item No. 21 here-in-before but on vertical surface such as skirting, dado over and including 10mm thick rendering in cement mortar (1:3). |
| 24 | Coloured Non Skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15 mm screed bed in cement mortar 1:4complete all as specified and directed. |
| 25 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for, removal of debris outside MoD land and stacking steel reinforcement for credit complete all as specified and directed. |
| 26 | Reinforced Cement Concrete 1:1.5:3 type A-1, using 20mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.Note:- Steel reinforcement bars and use and waste form work shall be measured and paid for separately. |
| 27 | Reinforced Cement Concrete (1:1.5:3) type A-1, using 20mm graded crushed stone aggregate as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed.Note:- Steel reinforcement bars and use & waste form work shall be measured and paid separately. |
| 28 | Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 29 | Demolition of cement concrete (unreinforcement) of any description and in any position not otherwise specifically provided for, and removal of debris outside MoD land complete all as specified and directed. |
| 30 | Dismantling brick tiles or terracing tiles, single layer on roof including segregating and stacking serviceable brick tiles for re-use and removal of unserviceable brick tiles / brickbats and rubbish outside defence land, complete all as specified and directed. |
| 31 | Demolition of mud phuska on roofs, any thickness, including mud plaster, leeping plaster and bottom layer of polythene film if any, including removal of retrieved material outside defence land, complete all as specified directed. |
| 32 | Cutting out cracks to \"V\" section in existing RCC roof slab or terracing , cleaning out, wetting, grouting with cement and sand slurry in CM (1:3), complete all as specified and directed. |
| 33 | Cutting groove in brick wall, 75mm wide and 65mm deep, for inserting APP polymer membrane and shaping horizontal face of groove with cement mortar 1:3, including removal of rubbish outside MoD land, complete all as specified and directed. |
| 34 | Plain cement concrete(1:2:4) type B-1 using 20mm graded crushed stone aggregate as to fill/level up depressions/cracks/to maintain desired slope on existing/old roof slab, of required thickness, finished even and fair to receive tiles/ APP membrane, including wire brushing, cleaning, washing and preparing roof surface before placing concrete complete all as specified and directed. |
| 35 | Plain cement concrete (1:2:4) type B-0 using 12.50 mm graded crushed stone aggregate, as in roof kerb, mud stops, benching and coping etc, including use and waste necessary form work, complete all as specified and directed. |
| 36 | 10mm thickcement plaster in CM (1:4) mixed with WPC as per manufacturer’s instructions @ 3% by weight of cement on concrete surfaces, finished even and smooth without using extra cement, after applying neat cement slurry @ 3Kg/Sqm, including wire brushing, cleaning, washing and preparing roof surface, complete all as specified and directed.Note : WPC shall be measured and paid separately. |
| 37 | Filling expansion joint with 12mm thick pre-formed filler for expansion joints complete all specified and directed. |
| 38 | 01 mm thick plain aluminium strip 300mm wide as on crumple jointswith all necessary suitable rawal plug and screws, fixed in repair complete all as specified and directed. |
| 39 | Water proofing treatment of RCC roof consisting as under:- (a) Applying evenly a coat of bituminous primer conforming to IS-3384:1986 @ 0.40 litre/Sqm over the prepared roof surfaces.(b) A layer of 3 mm thick APP polymeric membrane of weight not less than 3.60 Kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/sqm), duly sealed at over laps & joints with flame (by torch application) all as per manufacturer’s instructions, complete all as specified and directed.Make - MOPLY - FP manufactured by M/s Texsa India Ltd or IWL (HYPERPLAS POLYSTER) manufactured by M/s IWL or other makes in Appx B.Note:- The over lap shall be minimium 100 mm in transverse direction and 75 mm in longitudinal direction. |
| 40 | Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) mixed with approved WPC as per manufacturer\"s instructions, and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified and directed. Note:- WPC shall be measured and paid for separately. |
| 41 | Reinforced Cement Concrete (1:5:10) type E-1, using 20mm graded crushed stone aggregate for filling of RCC columns Stubs/Extension columns including coating the existing reinforcement bars with anti-corrosive paint,complete all as specified and directed.Note:- Use & waste form work shall be measured and paid separately. |
| 42 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions; square, rectangular or polygonal on plan; rough finished surface of concrete complete all as specified and directed. |
| 43 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), flat, rough finished surface, complete all as specified and directed. |
| 44 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc, rough finished flat surface of concrete complete all as specified and directed. |
| 45 | WPC wall panelling, hollow cored, 5mm thick, decorative designs with smooth surfaces, fire resistant, water and heat proof, tongue and groove edge for easy assembly with all accessories such as U cap, end cap, tee, plugs, fillets and screws etc and fixed in repair, all as per manufacturer\"s instructions complete all as specified & directed.Note : WPC frame shall be measured and paid separately. |
| 46 | WPC wall panelling, solid cored, 5mm thick, decorative designs with smooth surfaces, fire resistant, water and heat proof, tongue and groove edge for easy assembly with all accessories such as U cap, end cap, tee, plugs and screws etc and fixed in repair, all as per manufacturer\"s instructions complete all as specified & directed. |
| 47 | 5 mm thick WPC sheet fillet of width 35 mm fixed on wall to make PVC Frame as per specification and drawing,fixed in repair,complete all as specified and directed. |
| 48 | Demolitionofstone slabs and tiles of any description or thickness in floors, aprons, etc laid, bedded and pointed in any mortar and removal of debris outside MoD land complete all as specified and directed. |
| 49 | 18 mm thick granite (of any type) work, machine cut, (table rubbed and mirror polished) in steps, jambs, pillars, window cills, cooking platforms and like laid over and including 20mm thick cement mortar (1:4), and set with grey cement slurry @ 3Kg/Sqm, jointed and pointed in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including rubbing and polishing (mirror finish), complete all as specified and directed. |
| 50 | All as per Srl item No. 48 here-in-before but in wall lining/vertical surfaces/skirting over 10mm thick rendering in cement mortar (1:3). |
| 51 | Extra over Granite or marble slabs as in rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc complete all as directed. |
| 52 | 18-20 mm thick green marble work (table rubbed and mirror polished) in steps, jambs, pillars, window cills, cooking platforms and like laid over and including 20mm thick screed bed in cement mortar (1:4), and set withgrey cement slurry @ 3Kg/Sqm, jointed and pointed in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including rubbing and polishing (mirror finish), complete all as specified and directed. |
| 53 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 54 | Rolled mild steel in structural steel work in tubular trusses, posts and purlin including special shaped washersetc. complete using induction butt welded tubes conforming to IS 1161- 1979 grade St.- 240 withone shop coat of zinc chromate primer paint complete all as specified and directed. |
| 55 | All as per Srl item No. 53 here-in-before but in door frame. |
| 56 | Preparation of new steel surfaces of any description, not otherwise described, over 10cm width or girth, applying two coats of synthetic enamel paint over and including one coat of red oxide primer, complete all as specified and directed. |
| 57 | Demolition of plain or corrugatedsheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed. |
| 58 | Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm of mangalore pattern of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 59 | Pre- painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in valley/gutter/eve board fixed with self tapping screws etc., complete all as specified and directed. |
| 60 | Taking down chowkhats or frames of area n exc 1.5 Sqm each (without taking off shutters from the frame)complete all as specified and as directed. |
| 61 | Taking down chowkhats or frames of area exc 1.5 Sqm but n.exc 4.00 sqm each (without taking off shutters from the frame)complete all as specified and as directed. |
| 62 | Aluminium frame with powder coating (minimum thickness of powder coating 50 micron) for doors, windows, ventilators, partitions etc. with one or more rebates including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and directed.Note: Glass panes & ACPshall be measured & paid separately as \"Supply only\". |
| 63 | Aluminium door shutters with powder coating (minimum thickness of powder coating 50 micron),aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 No in each door, hinges, anodised aluminum snap beading, screws, fixing with aluminium beading or as manufacturer\"s instructions including joint filling and tapping ACP, with necessary arrangement etc. complete all as specified and directed.Note: Glass panes & ACPshall be measured & paid separately as \"Supply only\". |
| 64 | Aluminium window and ventilator shutter fixed type/sliding type without sash bar, with powder coating (minimum thickness of powder coating 50 micron), aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, tinned tacks or stainless steel wire staples forfixing wire gauge/slazing etc complete all as specified and directed. Note: Glass panes & wire gauge shall be measured & paid separately as \"Supply only\". |
| 65 | Factory made aluminium grill, powder coated (minimum thickness of powder coating 50 micron),of approved design/pattern, with approved standard section and fixed to the existing window frame with matching screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved powder coated aluminium standard section around the opening, all as per manufacturer\"s instructions complete all as specified and directed. |
| 66 | Bright finished brass 100 mm mortice lock with four levers vertical typewith necessary screws etc complete all as specified and directed. |
| 67 | Floor door stopper 140mm of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor all as specified and directed by Engineer - in - Charge. |
| 68 | Supply only 4.8 mm thickfloat glass, tinted, ordinary quality for aluminium doors and windows complete all as specified and directed. |
| 69 | 4.8 mm thickfloat glass, tinted quality and glazing with and including aluminium beading and rubber gasket for aluminium Doors and windows complete all as specified and directed. |
| 70 | 4mm thick ACP of approved color as in doors, windows & partitions fixing with aluminium beading or as manufacturer\"s instructions including joint filling and tapping, with necessary arrangement complete all as specified and directed. |
| 71 | Supply only 4mm thick ACP of approved color as in doors, windows & partitions fixing with aluminium beading or as manufacturer\"s instructions including joint filling and tapping, with necessary arrangement complete all as specified and directed. |
| 72 | Supply only 3.0 mm thick figuredglass,pin head type glazing with oil putty in squares not exc. 0.50sqm in each panecomplete all as specified and directed. |
| 73 | Supply only stainless steel wire cloth, 0.36mm nominal dia. of wire and average width of aperture 1.40mm, complete all as specified and directed. |
| 74 | 80 N, 30cm long, superior metal body, hydraulic gas spring-lift support strut for kitchen cabinet/overhead storage doors/flaps, soft silent open/close, fixed in repair complete all as specified and directed. |
| 75 | Floor spring double action hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box main body with steel cover, govening pivot made of brass, other parts made of MS heavy duty and fixed complete all as specified and directed. |
| 76 | Taking up or down 15mm bore steel tubing with all standard fittings or connections, from wall/ceiling/floor etc., including removal from site to store/for re-use or for credit, complete all as specified and directed. |
| 77 | 20 mm outer dia CPVC pipes SDR 11 & special CPVC SDR 11 fittings, on walls/ ceiling or laying in floors complete all as specified and directed. |
| 78 | All as per Srl item No. 76 here-in-before but 25 mm outer dia. |
| 79 | Cutting chases, pinning in making good to facings where required and pointing in cement mortar (1:3) or PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10cm girth, and removal of rubbish outside MoD land, complete all as specified and directed. |
| 80 | Brass elbow suitable for 20mm outer dia CPVC Pipe complete all as specified and as directed. |
| 81 | Brass elbow suitable for 25mm outer dia CPVC Pipe complete all as specified and as directed. |
| 82 | Brass tee suitable for 20mm CPVC Pipe complete all as specified and as directed. |
| 83 | Brass tee suitable for 25mm outer dia CPVC Pipe complete all as specified and as directed. |
| 84 | Vitreous china wash down water closet pan (Pedestal Pattern) white complete, excluding flushing cistern and flush pipe butincluding plastic water closet seat cover, black, closed pattern with flat bottom with mild steel chromium plated or aluminised hinging device and fixing with all joints to WC pan complete all as specified and directed. |
| 85 | Flushing cistern, low level, 10 litre capacity virgin PVC, valveless syphonic action type,white or coloured, complete with inlet, handle, ball valve and float, mounting brackets / fixing bolts, PVC bend/flush pipe of PVC 32 mm bore and making all connection, fixed in repair, complete all as specified and directed. |
| 86 | Vitreous china wash basin, white, flat back, size 550x400mm including waste fitting brass chromium plated 32 mm dia, fixing with new brackets including cutting and pinning in ends of brackets, fixed in repair complete all as specified and directed. |
| 87 | Vitreous china table top wash basin, white, size 420x420x155 mm including waste fitting brass chromium plated and placing in position, fixed in repair complete all as specified and directed. |
| 88 | Pillar taps 15mm bore dia, fancy type, cast copper alloy with capstan heads chromium plated, screwed down, high pressure with or without lettered Hot or Cold, with long screwed shanks and fly nuts screwed for iron pipe, fixed in repair complete all as specified and directed. |
| 89 | Soap dish brass chromium plated, fixed to plugs with brass chromium plated screws, fixed in repair complete all as specified and directed. |
| 90 | Bib tap, cast copper alloy, chromium plated, screwed down high pressure, with any type of handle, screwed for 15mm dia bore iron pipe or for brass ferrule, fixed in repair complete all as specified and directed. |
| 91 | All as per Srl item No. 89 here-in-before but 2-way. |
| 92 | Stop valves/Angle tap, 15 mm bore, cast copper alloy, screwed down , high pressure, with crutch or butterfly handles , screwed both ends for iron pipe or for unions,fixed in repair complete all as specified and directed. |
| 93 | Brass CPfancytype wall mixer with L- bends (including provision of O/H shower & hand shower) for mixing hot & coldwater, screwed down for iron pipe 15 mm bore,including hand shower and tube complete all as specified and directed. (Make Hand shower cat part no. HSH-CHR-1717 and wall mixer cat part no. QQT-7281 of Jaquar or equivalent in make Kohler/Marc) |
| 94 | Brass chromium plated shower rose 125mm size,with swivel joints, fixed to steel pipe or union 15 mm bore with and including 195mm long arm, fixed in repair complete all as specified and directed. (Make: Marc or equivalent make of Jaquar/Kohler) |
| 95 | PVC (SWR) floor trap 75mm dia of outlet, plain with grating including jointing to waste pipe, fixed in solvent cement complete all as specified & directed. |
| 96 | Stainless steel tolilet paper holder, flat recessed type, fixed to wall with chromium plated (CP) brass screws complete all as specified & directed. |
| 97 | Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP brass bracket guard & railing 60cm long complete all as specified & directed. |
| 98 | Looking mirror of size as directed, bevelled edge mirror 5mm thick of selected quality glass, fixed with SS studs & suitable spacers, fixed in repair complete all as specified and directed. |
| 99 | Chromium plated brass towel rail 600mm long complete all as specified and directed. |
| 100 | Stainless steel sink made of 1.00 mm thick sheet for kitchen with plugs washers & wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size495mmx420mm with bowl size410mmx330mmx160mm, with and including PVC waste pipe and CP waste coupling 32 mm, fixed in repair, complete all as specified directed. |
| 101 | Vitreous China urinals, half stall type of size 580x380x350 mm complete with all fittings, standard size C.P. brass including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, flush pipe, grating and union for discharge pipe, PVC connection with CP brass spreader, CP brass waste fitting and PVC waste pipe, fixed in repair, complete all as specified directed. |
| 102 | Vitreous china urinal partition white of size 310x700 mm, terminating about 40cm above floor line, fixed in repair, complete all as specified directed. |
| 103 | Cutting into existing manholes for connecting new drains 100mm dia, making good to pipe & rendering, cutting out existing benching for & forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, & reforming benching as required, Internal dia of pipe in 100 mm complete all as specified & directed. |
| 104 | Health faucet with 1.25 m long tube & wall hook, all chromium plated brass, suitable for 15mm size pipe, fixed in repair, complete all as specified directed. |
| 105 | PVC flexible waste pipe of standard length 25mm dia. with PVC cap suitable for waste coupling 32/ 40mm, fixed in repair, complete all as specified directed. |
| 106 | Dismantling of PVC drain pipes 100mm bore, with fittings, jointed in cement mortar and taking out of trenches complete all as specified and as directed. |
| 107 | Dismantling of PVC drain pipes 75mm bore, with fittings, jointed in cement mortar and taking out of trenches complete all as specified and as directed. |
| 108 | PVC (SWR) soil or waste pipe, 110 mm bore, single socket, in any length, type \"B\" with rubber ring joints, laid in trenches orfloor complete all as specified and directed. |
| 109 | All as per Srl item No. 108 here-in-before but fixed to wall. |
| 110 | PVC (SWR) soil or waste pipe, 75 mm bore, single socket, in any length, type \"B\", with rubber ring joints, fixed to wall complete all as specified and directed. |
| 111 | PVC (SWR)bend any radius,75 mmbore complete all as specified and directed. |
| 112 | PVC (SWR)bend any radius,110 mmbore complete all as specified and directed. |
| 113 | PVC (SWR) 75mm branch piece, single (double Y), equal or unequal complete all as specified and as directed. |
| 114 | PVC (SWR) 110mm branch piece, single (double Y), equal or unequal complete all as specified and as directed. |
| 115 | PVC (SWR) 75 mm junction double, (double T),equal or unequal complete all as specified and as directed. |
| 116 | PVC (SWR) 110mmjunction double, (double T),equal or unequal complete all as specified and as directed. |
| 117 | Stainless steel Wall panel:-Pre-fabricated wall panelling made of Stainless Steel 304 Grade with 50 to 60mm thick puff insulation with pressure injected of rigid polyurethane foam minimum density 40kg /cum, sandwiched between inner and outer stainless steel sheeting having 0.80mm thickness each.The wall panels to be fixed on metal Grid frame work sufficient enough to withstand the entire wall panelling work including making / cutting necessary opening if any required as per site conditions for fixing switch boards / gas pipeline/ electrification works and equipment etc. Joints:- The individual wall panel shall use the tongue and groove / suitable technology for joining two panels with minimum number of junctions. No welding shall be allowed. The gaps between Wall Panels to be filled with metalic epoxy filler and sanded flush giving seamless appearance and finished to fine grain surface to the entire wall panelling.The angular corners to be made with 130° - 140° angular modular element.Anti Bacterial Paint:- The stainless steel wall Panelling to be painted with dryfilm thickness of minimum 300microns over primer. The paint to be Anti-bacterial / Anti-microbial/Antifungal, resistant to UV lights, disinfactants, steams, fumigation agents etc. Painting to be applied by approved applicator with air-less spray gun. Color and tint of paint to be approved by the GE. The painting protection and preventation of the growth of mould, bacteria and yeasts for 5 years be given by the manufacturer.The wall Panels shall be CE/UL/ETL/US FDA/BIS/DIN 1.4301 Certified/Listed.Test report from Govt certified lab for anti-microbial, Stainless Steel & properties of paint will be submitted by the contractor at the time of Pre-Dispatch inspection/supply by Accepting Officer\"s Rep, complete all as specified and as directed. Note : Wall panelling to be provided flushed with storage cabinet / space side and size of grid for wall panellingwill be fixed accordingly. |
| 118 | Stainless Steel Ceiling Panel:-Pre-fabricated false ceiling panels made of Stainless Steel 304 grade injected with rigid polyurethane foam puff insulation of minimum density 40kg /cum, sandwiched between inner and outer stainless steel sheeting having 0.80mm thickness each, with total thickness of panel 30-40mm.The false ceiling panels to be fixed on metal grid frame work sufficient enough to withstand the entire false ceiling work including making / cutting necessary opening, if any, required as per site conditions for fixing any electrification works and equipment etc. Joints:- The individual ceiling panel shall use the tongue and groove / suitable technology for joining two panels with minimum number of junctions. No welding shall be allowed. The gaps between Ceiling Panels to be filled with metalic epoxy filler and sanded flush giving seamless appearance and finished to fine grain surface for the entire celing panelling.The angular corners to be made with 130° - 140° angular modular element. Anti Bacterial Paint:- The stainless steel celing panelling to be painted with dry film thickness of minimum 300 microns over primer. The paint to be Anti-bacterial / Anti-microbial/Antifungal, resistant to UV lights, disinfactants, steams, fumigation agents etc. Painting to be applied by approved applicator with air-less spray gun. Color and tint of paint to be approved by GE. The painting protection and preventation of the growth of mould, bacteria and yeasts for 5 years shall be given by the manufacturer. The Ceiling Panels shall be CE/UL/ETL/US FDA/BIS/DIN 1.4301 Certified/Listed. Test report from Govt certified lab for anti-microbial, Stainless Steel & properties of paint shall be submitted by the contractor at the time of Pre-Dispatch inspection/supply, complete all as specified and as directed. |
| 119 | Vinyl Flooring:- Antisatic, conductive seamless vinyl flooring having minimum 2mm thickness laid after cleaning and preparation of existing floor surface including 3 to 4mm thick Self leveling with epoxy compound followed by 0.50mm thick 50mm wide Copper strip to be made visible by ginding and no copper strip shall project more than 0.5mm above level surface to avoid damage to Vinyl sheet. The suitable grid of copper strip to be laid under vinyl flooring. One earthing lead shall be brought out from every 150 Sqft area and attached to the main earthing strip / ground. Flooring to be seamless smooth, non slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Continious roll of vinyl flooring shall be used and joints shall be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets shall be highly durable and resistance to shock, scratch and indentation. The conductive material shall be uniformly impregnated as grains. It shall be inert to body fluids, chemicals and disinfectants and shall not be affected by temparature variations wthin the OT. The flooring to be laid by skilled worker of accredited agencies authorised by the manufacturer of vinyl sheets.Electrical Resistance:-The floor shall efficiently discharge electric charges up to 2KV. The electrical resistance ( point to ground ) shall be within 2.5 x10000 to 5 x 1000000 Ohms. The floor shall not allow build-up of electrical charge beyond 100 V due to antistatic effect.(c) Properties:- Weight of vinyl floor roll shall be 3100gm/sqm in the roll size of 2mx20m. The corners shall not be terminated sharply and concealed cove - former ( alumnium) shall be used to overlap the wall panel to a height of approximately 25 mm and saled perfectly and uniformly. Flooring shall be highly durable and resistant to shock, scratch proof, indentation proof, flame retardant and antimicrobial. Corners shall be uniformly covered. Colour shall be uniform, pleasent and matching with ambience and approved by the GE as per ISO 16000-6. Shall be REACH compliant, complete all as specified and as directed. Note:- (i) The requirement of conductive floor with requisite earthing will cater for 10 No of OTs with size as given in the Line Plan provided with this tender. (ii) The approximate distance from copper grid to the nearest earthing deemed to be included in this item shall be 20m. |
| 120 | Wall cladding:- Anti-microbial silver ion technology PVC wall cladding having minimum 2.50mm thickness or more, smooth finished having approx weight 3.5kg /sqm, able to withstandtemperature upto 60°C. Method of Fixing:- Cladding to be fixed with Aluminium pipe of size 25x40 mm with thickness of 1.20 mm on grid framework of 600 mm X 600 mm accuretly aligned with 6mm thick Bison board using raw plugs etc.Joints:- PVC cladding to be sealed by hot welding providing a water tight smooth and seamless finish. Internal / external corners of the PVC cladding shall be able to thermoformed on site to provide seamless uniform corner arrangement. Coving between wall and ceiling to be provided with same PVC cladding company, complete all as specified and as directed. Note:PVC cladding shall be VOC ( Volatile Organic Compound) compliant, certificate to be enclosed as per EN 13999:2013 BREEAM and shall have a Fire Rating in accordance to EN 13501-1:2007+A1:2009. Contractor shall submit the Third party Test Certificate and warrany for 5 years. |
| 121 | Automatic Hermetically Sealed sliding door with electronic automation unit :Door:-Sliding door made of HPCL / HPL material painted with anti bacterial paint. Thickness of Door shall be 50 to 60mm injected with CFCfree polyurethane foam puff insulationhaving minium density of 40 kg /cum. Colour of door from interior to match the interiors of room & from outside to match with the outer area.The door shall have double glazed vision window of size 300mm x 300mm and hermetically sealed. The Hermetic sealingshall conform to class 4 (EN 1.026,EN 12.207). Door shall move smoothly on roller. Either side of door shall be perfectly leveled. Door leaf shall have high quality synthetic rubber gasket with long life to ensure hermetic sealing (to maintain air pressure differential), Air tightness 99.99% at a pressure of 100KPa. Dimension of door shall be 1500mm x 2100mm with lead line(as per AERB Norms) (size may vary slightly as per site requirement).The rates are inslusive of following Automation & Hardware / Accessories:- Door to be provided with both touchless sensor based switch button on each side and foot operated switch . Door to be provided with suitable hinges to withstand the load of door, locking system, 300mm long HPL Handleson inner and outer side. Operation of door shall be microprocessor controlled electro mechanical movement mechanism should allow manual opening in case of power failure. Speed of closing movement to be between 80-120mm/sec and opening speed should be 600 to 800 mm/sec (approx) with option of customised opening & closing time, speed of door leaf including half opening option. The door and controls shall comply with IEE regulation. All motors shall be DC brushless/PMDC motors with esential isolation from mains, complete all as specified and directed. Notes:- (i) The complete door shall be CE(Compliance to European standards) certified or relevant equivalent IS certification, if any. Test certificate for hermetic sealing with door frame shall be provided by the contractorwith pre despatch documents. (ii) Suitable size of copper cable compatible with automation of door deemed to be included in the quoted rate. |
| 122 | Hermetically Sealed Hinged Door Door:- Hinged door made of HPCL / HPL material painted with anti bactrial paint. Thickness of door to be 50 to 60mm injected with CFCfree polyurethane foamPuff insulation having minimum density 40 kg /cum. Colour of door from interior to match the interiors of room & from outside to match with the outer area.The door shall have double glazed vision window of size 300mm x 300mm. The hermetic sealingshall conform to class 4 (EN 1.026,EN 12.207). The movement of door to be smooth. Either side of door should be perfectly leveled. Door leaf should have high quality synthetic rubber gasket with long life to ensure hermetic sealing (to maintain air pressure differential), Air tightness 99.99% at a pressure of 100KPa. Dimension of door shall be 1500mm x 2100mmwith lead line (as per AERB Norms) ( size may vary slightly as per site requirement).The rates are inslusive of following automation & hardware / accessories : Door to be provided with suitable hinges to withstand the load of door, locking system with keys, heavy duty hydraulic door closer, 300mm long HPL Handles and 250mm long HPLtower bolts on each side and door stopper, complete all as specified and directed. Note : The complete door shall be CE (Compliance of European standard) certified. Test certificate for hermetic sealing with door frame shall be provided by the contractor with pre despatch documents. |
| 123 | All as per Srl item No. 122 here-in-before but dimension of door shall be 1000mm x 2100mm. |
| 124 | Window with motorized roller BlindsFactory made UPVC fixed type window made of extruded profiles with wall thickness of 2.3mm(+/- 0.2 mm), Window profile with hollow section with multi chamber, Frame (60mm x58mm), T profile(60 mm x 74 mm), Glazing bead (35 mm x20 mm) shall be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc,. making arrangement for fixing of hardware, EPDM gasket 1.2 +/- 0.2 mm thick, galvanized steel Frame (28 mm x 21.5 mm), T profile (27 mm x 17 mrn) to be inserted in required profile including 6 mm thick two parallel toughened glass and motorized curtain blinds with FHP motor control and ACB view panel, Blinds shall be sandwiched in two parallel glass panes,The window shall be fixed in such away that replacement / maintenance of blinds, motors, switches etc shall beeasily accessible without taking any additional shutdown,complete all as specified and as directed. Note :Suitable size copper cable compatible with automation of door deemed to be included in the quoted rate. |
| 125 | Compact surgical scrub sink of overall size2400 mm long x 600 mm wide and 1300 mm high with tub depth of minimum 380 mm divided into two sink portions, made of 1.50 mm thick Stainless Steel sheet of 316 grade with seamless welded construction, polished to stainless finish. Each sink portion to have one sensor based CP brass water sink mixer system for hot and cold water, one sensor based bib tap, one sensor based betadine dispenser and one foot operated switch for hands free operation including infra-red sensors with built-in temperature range adjustment and thermostatic mixing valve control located behind the access panel and maintain constant water temperature. The scrub sink to be provided with front access panel easily removable for access to the water controlled valve, waste connections stoppers and strainers complete all as specified and directed. |
| 126 | Storage unit made with 0.80 mm thick stainless steel 304 grade sheet, to be continuously ventilated by positive air in the room through ventilation holes provided at the bottom and top of opposite sides, the storage unit to be divided into 2 or more parts, as directed, and each part shall have individual 10 mm thick toughened glass shelf. The overall size shall be 1200mm wide x 2100mm high and 350mm deep complete all as specified and directed. |
| 127 | Factory made UPVC casement (Openable) Door made of extruded profile with wall thickness of 2.3 mm (+/- 0.2mm). Door profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 78mm), T profile (One vertical length in between two shutters) (60mm x74mm), Glazing bead (35mm x 20mm) shall be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +/- 0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), profile (27mm x 17mm) to be inserted in required T profile, frame shall be fixed to wall wilh 8 mm x 100 mm long fasteners.Hardware: Door to be provided with suitable hinges to withstand load of door, locking system with keys, heavy duty hydraulic door closer, suitable Handles and 250mm long Stainless steeltower bolts on each side and door stopper, Door transmission gear made of mild sleel with multi point locking system with strikes (white powder coated) and bottom portion to be fixed with 4mm ACP sheet panel, on top portion glazing with 8mm thick toughened glass, fixed in repair complete all as specified and directed. |
| 128 | Factory made UPVCfixed / openable window made of extruded profiles with wall thickness of 2.3 mm(+/- 0.2mm), Window profile with hollow section with multi chamber, Frame (60mm x58mm), T profile (Onevertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x20mm) will be mitred cut and fusion welded at all corners including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket 1.2 +/- 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame shall be fixed to the wall with 8mm x 100mm long fasteners and glazing with 8mm thick toughened glass, including taking down old window and making good existing surface, (Area exceeding 1.00 sqm but not exceeding2.00 sqm each ), complete all as specified and directed. |
| 129 | All as per Srl item No. 128 here-in-before but area exceeding2.00 sqm each. |
| 130 | Stainless steel double bowl sink made of 1.00 mm thick sheet for kitchen or laboratory with plugs washers & wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx510mm with bowl size420mmx420mmx225mm, with and including PVC waste pipe and CP waste coupling 32 mm, fixed in repair, complete all as specified and directed. |
| 131 | 52mm thick PVC Partition consisting of 12mm thick plain solid PVC ply sheet reinforced with frame work made from 40mm x 20mm MS tubes. In between two MS tubes, 5mm thick Plain heat moulded \"C channel of size 75mmx50mm with feathered edges shall be fixed on the floor, wall and ceiling. Plastic ply opanel shall be inserted in the PVC \"C channel. The first & last MS tube should be errected such that it is inside a PVC \"C channel, in between adjoining plastic panel, 5mm thick x75mm width plain PVC sheet feathered at edges shall be stick on the front & back face using solvent cement complete all as specified and directed. |
| 132 | Compact surgical scrub sink of overall size1000 mm long x 600 mm wide and 1300 mm high having wash with tub depth of minimum 380mm, made of 1.50mm thick Stainless Steel sheet 316 grade with seemless welded construction, polished to stainless finish. Sink shall have one sensor based CP brass water sink mixer system for hot and cold water, one sensor based bib tap, one sensor based Betadine despenser and one foot operated switch for hands-free operation including infra-red sensors with built-in temperature range adjustment and thermostatic mixing valve control located behind the access panel and maintain constant water temperature. The scrub sink to be provided with front access panel easily removable for access to the water controlled valve, waste connections stoppers and strainers complete all as specified and directed. |
| 133 | HDHMR prelaminated (one side and inner side balancing white) board of 18-20 mm thick having minimum density of 32kg/cum as in Nursing Station work / cabinet work/ Shelves Side hung/ top hung including alll necessary hardware which includes Moduler handles, SS hinges, Magnetic lock, hydraulic closer for top hung shutter cabinets with push & press lock system, fittings, taping on edges etc completeall as specified and directed. |
| 134 | Door closer hydraulically regulated, aluminium (extruded section) body, designation No. 3, universal type suitable for top hung cabinet shutter upto 700mm in width and of weight not more than 35 kg complete all as specified and directed. |
| 135 | Stainless steel magnetic hinges 70-80 mm long L type suitable for modular kitchen cabinet shutters complete all as specified. |
| 136 | Stainless steel sliding channels suitable for modular kitchen cabinet drawers/racks upto 800mm long complete all as specified and directed. |
| 137 | Brass cupboard knobs 35-40mm dia fixed with ss srews complete all as specified and directed. |
| 138 | Fancy SS handles, any type, 75mm size complete all as specified and directed. |
| 139 | Bright finished brass 75 mm mortice lock with 2 levers, vertical typewith necessary screws etc complete all as specified and directed. |
| 140 | 15mm bore central hole basin mixer chromium plated brass for mixing hot & cold water screwed down for iron pipe and fixed in repair complete all as specified and directed . |
| 141 | Machine cutkota stone slabflooring,20-25mm thick over 15mm thick cement screed in cement mortar (1:4)base laid andjointed with grey cement slurry mixed with pigment to match theshade of the slab including rubbingand polishing complete all as specified and directed. |
| 142 | Fully Automatic Single/double leaf sensor sliding door with operating system (Total size varying from 1200mm to 2400 mm wide and sensor door opening size of 1200/1500/2000 mm wide x 2400 mm high) with ST flex profile, complete with future European standards and produced according to the guidelines for power-operated windows, doors and gates BGR 232, the UVV and the VDE regulations. TÜV design tested. Fulfils the DIN V18650 (prEN 12650).Automatic Sliding Door system should have mounting backplate for easy installation and a flexible track profile for improved noise & vibration dampening and easy maintenance. Microprocessor-controlled control unit. Self-learning, with adjustable parameters for opening and closing speed, hold-open time and opening and closing force.Class of protection IP 20. Automatic door system shall be with Anti-Jump fitting. Door Panel weight greater than 90 kg for each panel with the following accessories and all necessary electrical connections :-Function programs: Program Modes: - Off, Automatic,Permanent open,Exit only, Partial open.Adjustable Hold Open Time: Hold Open is easily adjustable at module as per client’s requirement, Hold Open Time: 0.5 – 30 Sec. Adjustable Parameters Via parameter display and selection key at electronic module.Adjustable Opening Speed: 10 -50 cm/s,Adjustable Closing Speed: 10 – 40 cm/s, Auto Error Display with Error Code Display for error correction. Read-out error store with error codes, Emergency off – Connection for Emergency Off Button, On activation operator will open fully and stop all functions, enabling passenger to pass through in case of panic. Safety devices: Inbuilt obstruction detection feature with automatic reversing cycle on obstruction, dynamic and static force limitation, emergency control unit (emergency stop) etc. |
| 143 | Safety PhotoCells: 1/ 2 Pair of Photo Cells are provided for safety of passenger standing in line of motion of Moving Panel and for through-passage monitoring Connection: 230 V, 50/60 Hz, UPS Supply, complete all as specified and directed.Activators: Radar system 02 No, with 24 GHz, Mandatory as Int’Nat Standards, Light barriers, comprising receiver and transmitter -01 Pair.For shutter all necessary hole/cut-outs & edge polishing, finished at site to be provided, bistable, UPS of 750 VA shall be provided, which will give power backup upto 20 minute.Note:- (i) 12 mm thick toughened glass as \"Supply only\" shall be measured and paid separetely. However fittings and fixtures are included in quoted rates for this item.(ii) Two year maintenance and service shall be provided by the contractor as per manufacturer\"s instructions and cost of the same shall be included in the quoted rates against this item itself. |
| 144 | Supply only Toughened glass selected quality 12mm thickness as in hinged doors, partitions, automatic doors and similar work cutting to shape, drilling holes as required complete all as specified and directed. |
| 145 | Water proofing treatment to sunken floors of bathroom/WC/kitchen etc. as given below, complete all as specified and directed: -(a) Cleaningthe concrete surface of top of the RCC slab and peripheral beams of sunkenportion by wire brushing & washing with water. (b) Making fillet of size 25 x 25 mm at corner of slab & wall with polymer modified cementitious (PMC) mortar consisting of 01 part TAPECRETE P-151, two parts cement and 6 parts of fine sand by weight. (c) Cutting out cracks, if any, to \"V\" section in existing RCC roof slab or terracing , cleaning out, wetting, grouting with PMC mortar.(d) Sealing of all joints/ trap/WC/Soilpipe with approved sealing compound. (e) Apply first layer of slurry of cement @ 0.488 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours.(f) Apply second layer of slurry of cement @ 0.242 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.(g)Paste 200 micron thick polythenefilm of approved make with approved adhesive to the treated sunken surface.(h)Applying 15 mm thick plaster in cement mortar 1:4 mixed with CICO Super @ 100 mlper 50 kg cement on treated surface. (j) Joints/ trap/WC/Soilpipe shall be properly sealedwith approved sealing compound.(k)Testing of all traps & joints shall be done after sealing and before filling of sunken slabs . Also refer TD117 (C) for filling the sunken floor with lean concrete 1:3:6 using cinder up to required depth but sorrounding of WC pan shall be filled with lime concrete and finish the surface using 40 mm thick PCC 1:2:4 finished the surface even and rough to receive top layer complete all as specified and as directed. |
| 146 | MILD STEEL WORKS (MISCELLANEOUS) framed work such as grills, grating, etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work for water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 147 | Designing, Engineering, Preparing erection drawings, providing, installing and fixing factory finished custom designed cold form Light Gauge Framing System (LGFS) super structure comprising as follows:- |
| 148 | LGFS - STRUCTURAL FRAME WORK: Designing, preparation of drawings, fabrication, supply & erection Light Gauge Framing System (LGFS) cold form structure system comprising C-frame in size 89mm x 41mm x 0.95mm thick for load bearing and non-load bearing walls consisting Hi-tensile Bare Galvalume steel (AZ150 gsm/ 550 MPA yield strength) or Hi-tensile Pre-Galvanized steel coils (Z-275 gsm Zinc coating mass both sides/ 550 MPA Yield strength) for all internal, external walls and trusses. The framing section shall be C type having (89mm depth x 41 mm flange x 11mm lip) in required length as per site condition with pre-punched dimple/slot at required location as per manufacturer approved drawings at various locations. The frame shall be supplied in knock down condition at site and fixed by mean of wafer head galvanised steel screws 4mm thick. The LGFS Frame structure shall be fixed above roof beam using hold on steel expanded fasteners. Vertical member shall be supported maximum 600mm c/c and horizontally frame at 800mm max. All framing shall be factory finished with service hole of 30mm round dia at 3 different levels to run conduits. Frame opening provision shall be made within the dry wall system as per approved architectural door and window schedule, complete all as specified and directed. |
| 149 | ROOF SHEETING AND UNDERDECK ROOF INSULATION: Supply and fixing of racdek hi-rib single skin bare galvalume silver finish in required and approved slope/design made of 0.50 mm +/- 5% total coated thickness (TCT) thick high tensile Galvalume steel (AZ150gsm/ 550Mpa) fixed over cold form purlin at 1.5 mtr c/c max girt by mean of 12-14mm steel self-drilling hex-head screws. The end rib shall be profiled with anti-capillary action to avoid any seepage of water through the lateral Self drilling, self-tapping fasteners for fixing the roof and side cladding shall be Tin- Zinc Coated with Xylon coated with EPDM seals conforming to AS:3566 Class-3. Color Coated Tonex cap of same colour as roof or wall will be used on screw head. The under deck insulation will be of 50mm thick glass wool of 16kg/m3 density with FSK and wire mesh, complete all as specified and directed. |
| 150 | FLASHING: All as per Srl item No. 149 here-in-before but in flashing, trim, ridges etc in similar material 0.5mm in required girth Approx. 300mm - 500mm Girth. |
| 151 | EXTERNAL WALL CLADDING: Supply and fixing of factory finished double layer heavy duty fiber (cellulose fiber) cement board on external face comprising first layer of 9mm thick and 2nd layer of 6mm thick fiber (cellulose fiber) cement board of exterior grade as per approved make fixed over LGFS Frame structure with steel wafer head screws, complete all as specified and directed. |
| 152 | WALL INSULATION: Providing & fixing 75 mm thick Rock wool Insulation of 48kg/m3 density and will install in the form of slab in the cavity of LGFS wall frame, complete all as specified and directed. |
| 153 | INTERNAL PARTITIONS AND INTERNAL WALL PANEL: Supply and fixing of factory finished 8mm thick Cement board as first layer and 2nd layer of 12.5mm thick Gypsum board of approved make of required size & length as per approved drawings. The board shall be fixed over LGFS Frame structure with steel wafer head screws and tapping to seal joints, complete all as specified and directed. |
| 154 | WINDOWS: Providing and fixing powder coated aluminium Three track sliding windows (02x glass shutter & 01x Mesh shutter). with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, including 6.0 mm thick clear float glass panes with EPDM rubber/ neoprene gasket with all accessories such as aluminium tower bolt, handles, casement friction stay hinges etc. all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 155 | Preparation of new APP membrane roof surface and applying one coat of aluminium paint@ 0.11 kg/sqm complete all as specified and as directed. |
| 156 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 157 | Re-fixing (after completion of civil work) hospital flex boards, token display board etc., retrieved and deposited in MES store vide Sl item 156 here-in-before including connecting up with suitable size of connectors/terminals end andthree core flexible copper conductor cable complete all as specified and directed. |
| 158 | Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FRLSH copper conductor 1100 V grade, ISI marked, drawn through and including suitable dia of rigid PVC conduit medium grade and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, by means of saddles and clips etc, including provision of modular metal flush boxes thickness not less than 1.2 mm with modular frame plate and white cover of required modules for housing switches, sockets, regulators etc., including 1.5 sq.mm PVC insulated unsheathed multi-stranded FRLSH copper conductor cable as earth continuity conductor and connecting to common earth dolly, for following points:- |
| 159 | One light point controlled by anti-bacterial type modular switch 6 Amp, single pole, one way, one module, 240V, complete all as specified and directed. |
| 160 | One ceiling Fan/Exhaust Fan/Wall fan point controlled byanti-bacterial type modular switch 6 Amp, single pole, one way, one module, 240V, complete all as specified and directed. |
| 161 | One5 Amp socket outlet point on independent board controlled by anti-bacterial type modular switch 6 Amp, single pole, one way, one module, 240V, complete all as specified and directed. |
| 162 | One5 Amp socket outlet point on same board controlled by anti-bacterial type modular switch 6 Amp, single pole, one way, one module, 240V, complete all as specified and directed. |
| 163 | One light point controlled byanti-bacterial type modular switch 6 Amp, single pole, two way, one module, 240V, complete all as specified and directed. |
| 164 | One bell/buzzer point controlled by anti-bacterial type one push button, one module, 240V on the same board with other switches or independent, complete all as specified and directed. |
| 165 | All as per Srl item No. 158 here-in-before but with 2.5 Sqmm single core multi stranded copper conductor of 1100 V grade PVC FRLSH insulated and sheathed cable for one multi-purpose anti-bacterial type switch socket outlet 6 pin6/16 Amp on independent board, controlled by anti-bacterial type modular switch 16 Amp, single pole, one way, two module, 240V,including 2.5 Sqmm single core solid copper conductor 1100 V grade PVC insulated and sheathed cable as earth continuity conductor to common earth and connecting to common earth dolly.Notes for Srl Items 158.00 to 159.07: (a) The quoted rate shall include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per site requirement etc.(b)Quoted rate shall also include cost of making necessary cuting chases in walls/floor for concealing conduit/metal boxes and making good the disturbed surfaces in cement mortar (1:4) or PCC (1:2:4) as required to match with existing.(c) Switches and fan regulator shall be measured and paid separately. |
| 166 | Anti-bacterial type modular switch 1 way 6A,1 module, conforming to IS 3854 complete all as specified and directed. |
| 167 | Anti-bacterial type modular switch 1 way 16A,1 module, conforming to IS 3854 complete all as specified and directed. |
| 168 | Anti-bacterial type modular Bell push 6A, 1 module, single pole one way and conforming to IS 3854 complete all as specified and directed. |
| 169 | Anti-bacterial type switch modular two way 6A,1 module and conforming to IS 3854 complete all as specified and directed. |
| 170 | Anti-bacterial type electric call bell/ buzzer, AC, 230 V, single pole, and conforming to IS 3854 complete all as specified and as directed by Engineer-in-Charge. |
| 171 | Anti-bacterial type modular socket, 6A - 2/3 pin combined 2 module and conforming to IS 3854 complete all as specified and directed. |
| 172 | Anti-bacterial type modular socket 6A/16A - 2/3 pin combined 2 module and conforming to IS 3854 complete all as specified and directed. |
| 173 | Anti-bacterial type modular fan step type regulator, 120W, 2 module and conforming to IS 3854 complete all as specified and directed. |
| 174 | Ceiling rose 65 x 50mm three terminals polycorbonate, isolated body complete all as specified and directed. |
| 175 | LED light fitting mirror type with high output diffuser 2 feet, 10 W, 220 V, AC, decorative type with driver holder and LED lamp, extruded aluminium channel in thermally conductive material and luminaire efficacy of 110 lm/W, beam angle 120 degree or more CRI > 80, LED life span not less than 50000 hr with drivers and others accessories and overvoltage protection including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 176 | LED tube light fitting 1 x 20 W, 220V, AC, decorative box type with driver, holder including LED tube light, aluminium extrusion body with powder coating, suitable for retrofit LED 1X20W LED tube rated luminaire efficacy 110 lm/W, beam angle 120 degree, CRI>80, LED life span not less than 50000 hr with drivers and others accessories and overvoltage protection including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 177 | Surface mounted Luminaire of size 2\"x2\" LED 36 Wequiped with CRCA powder coated housing, anti-glare diffuser with separate energy electronic driver of capacity 36 W minimum, 110 lm/W, CRI>80, LED life span not less than 50000 hr with drivers and others accessories and overvoltage protection including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 178 | Surface/recess mounted (as per site requirement) slim square/roundtype LED 15 W panel with die-cast aluminium housing and smooth powder coated finish with anti-glare UV stabilized diffuser and separate energy efficient eletronic driverhaving rated luminaire efficacy of 110 lm/W, CRI>80, LED life span not less than 50000 hr with anti-glare PC diffuser, drivers and others accessories and overvoltage protection including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 179 | LED Luminaire 36 W suitable for armstrong/grid ceilling of size 2\"x2\" with super bright LED luminaire efficacy 110 lm/W, recess mounted with drivers and others accessories and overvoltage protection, CRI>80, LED life span not less than 50000 hr with drivers and others accessories and overvoltage protection including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 180 | Decorative wall mounted lamp with one light Opal Glass with Chrome Finish (SS) including 1 x 7 W LED lamp, CRI>80, LED life span not less than 50000 hr with drivers and others accessories and overvoltage protection including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 181 | Span recessed/surface LED 1\" x 4\" panel ceiling light of 33/36 W with high performance, commercial grade solution suitable for hospitals, offices and having white powder coated CRCA housing,luminaire efficacy 110 lm/W with LED life span not less than 50000 hr, CRI>80, anti-glare diffuser with separate energy electronic driver with drivers and others accessories and overvoltage protection including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 182 | Downlight LED 15 Watt, 230 V, 50 Hz, AC supplycylinder type die cast aluminium with black/silver powder coated with PC Lens & reflector to ensure uniform illumination with a consistent color with combining aesthetics and high performance 1200 lm/W, CRI> 80 Ra, IP 20 rated suitable for modern interiors and commercial spaces with beam angle 24 degree, CRI>80, life span of LED 50000 hrs with drivers and others accessories and overvoltage protection including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 183 | LED Beacon Step light CRCA housing, powder coating with PC diffuserinbuilt, 06 Wrated luminaire efficacy 100 lm/W,suitable for concealed into surface wall/floor, super bright LED life span not less than 50000 hr,CRI>80 with drivers and others accessories and overvoltage protection including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 184 | Recessed/surface mounting sensor polycarbonate housing stand-alone 2 in 1microwavesensor(Day/Night + Motion) operating temperature range -10°C to + 40°C, rated voltage 220 V-240 V/AC, 50 Hz, power on delay 0-5 Sec, time delay/hold time 10 sec to 15 Minute (Adjustable), Load Capacity 400 W (LED Light), IP 20, detection angle/range 360°, detection distance max 6 m radius (Adjustable), installation height 2.2-4.0 m including all accessories as per manufactures recommendation, with drivers and overvoltage protection including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 185 | MCB distribution board of sheet metal, single pole and neutral (SPN), 12 way, double door, IP-54 & IK09 certified with fully shrouded Neutral bar, PU gasket, 200 Amp rated bus bar 240 V, conforming to IEC-61439-3 complete all as specified and directed. |
| 186 | All as per item No. 178 here-in-before but 08 way. |
| 187 | All as per item No. 178 here-in-before but 04 way. |
| 188 | MCB distribution board of sheet metal, triple pole and neutral (TPN) 04 way, double door, IP-54 & IK09 Certified with fully shrouded neutral bar, PU gasket, 200 rated bus bar, 415V, conforming to IEC-61439-3 complete all as specified and directed. |
| 189 | All as per item No. 179 here-in-before but 08 way. |
| 190 | All as per item No. 179 here-in-before but 12 way. |
| 191 | VTPN DB 12 way for MCCB as incomer, metal door, shrouded Neutral Bar, Mechanical Impact Strenth IK 09 certified, fully insulated busbar assembly, 2 neutral bar, 2 earth bar, cable ties, blanking plates, PU gasket suitable for 3-4 pole MCCBs upto 160 Amp as Incommer and MCBs (TP/TPN/SP/SPN) as outgoing, IP 54 protection, conforming to IEC 61439-3 completeall as specified and directed. Note:- MCCBs/MCBs/RCBOs shall be measured and paid for separately. |
| 192 | All as per item No. 180 here-in-before but 08 way. |
| 193 | All as per item No. 180 here-in-before but 04 way. |
| 194 | Taking down existing old unserviceable DBs alongwith MCCBs/MCBs/RCBOs/Metal clad etc. of any capacity/make and making necessary good the disturbed surfaces to match with existing complete all as specified and directed. |
| 195 | MCCB 400 A, 4 pole, 36 KA (Ics =100% Icu), Adjustable Thermal Fixed Magnetic account, fixed in replacement, complete all as specified and directed |
| 196 | MCCB 250 A, 4 pole, 36 KA (Ics =100% Icu), Adjustable Thermal Fixed Magnetic account, fixed in replacement, complete all as specified and directed |
| 197 | MCCB 200 A, 4 pole, 36 KA (Ics =100% Icu), Adjustable Thermal Fixed Magnetic account, fixed in replacement, complete all as specified and directed |
| 198 | MCCB 160 A, 4 pole, 25 KA (Ics =100% Icu), Adjustable Thermal Fixed Magnetic account, fixed in replacement, complete all as specified and directed |
| 199 | MCCB 125 A, 4 pole, 25 KA (Ics =100% Icu), Adjustable Thermal Fixed Magnetic account, complete all as specified and directed |
| 200 | MCCB 100 A, 4 pole, 25 KA (Ics =100% Icu), Adjustable Thermal Fixed Magnetic account, fixed in replacement,complete all as specified and directed |
| 201 | Supply and fix MCCB 160 Amp, 415 V, 4 Pole,Ics=100% of Icu, 16 kA complete all as specified and directed. |
| 202 | MCCB 100 Amp, 415 V, 4 Pole,Ics=100% of Icu,16 kA complete all as specified and directed. |
| 203 | MCCB 125 Amp, 415 V, 4 Pole, Ics=100% of Icu,16 kA complete all as specified and directed. |
| 204 | MCCB 63 Amp, 415 V, 4 Pole, Ics=100% of Icu,16kA complete all as specified and directed. |
| 205 | Supply and fix MCCB 40 Amp, 415 V, 4 Pole,Ics=100% of Icu,16 kA complete all as specified and directed. |
| 206 | RCBO 4 pole, 40-100 Amp, 415 V, electromechanical with rupturing capacity not less than 10 kA, and IEC 61009-1 all as specified and directed. |
| 207 | RCBO double pole (DP), 32-63 Amp, 240 V, electromechanical RCBOs used as DP RCBOs with rupturing capacity not less than 10 kA, 30mA, and IEC 61009-1 complete all as specified and directed. |
| 208 | MCB triple pole (TP) 25-63 Amp, 415 V,\"C\" Curvewith rupturing capacity not less than 10 kA complete all as specified and directed. (New Aircurtains) |
| 209 | MCB Three Pole and Neutral (TPN) 40-100 Amp, 415 V, \"C\" Curve with rupturing capacity not less than 10 kA complete all as specified and directed. |
| 210 | MCB Three Pole andneutral (TPN) 16-32 Amp, 415 V, \"C\" Curve with rupturing capacity not less than 10 kA complete all as specified and directed. |
| 211 | MCB Single Pole and Neutral (SPN), 32-63 Amp, 240 V,\"C\" Curvewith rupturing capacity not less than 10 kA complete all as specified and directed. |
| 212 | MCB Single Pole (SP) 06-32 Amp, 240 V \"C\" Curve with rupturing capacity not less than 10 KA complete all as specified and directed. |
| 213 | MCB Single Pole (SP) 06-32 Amp, 240 V \"B\" Curve with rupturing capacity not less than 10 kA complete all as specified and directed. |
| 214 | Single pole and neutral enclosures with two pin and earth plug and socket complete with single pole MCB SPN 20 Amp, 240 V complete all as specified and directed. (For Geyser). |
| 215 | Triple pole and earth enclosure with a three pin and earth plug with socket complete with MCB TP 32 Amp, 10 kA, 415 V complete all as specified and directed. (For Air curtains). |
| 216 | Industrial surface/wall mounting socket 63 Amp 3P+N+E4 pole with straight plug 63 Amp 3P+N+E, and sockets enclosure cabinet 5 module including incoming MCB TPN 63 Amp, complete all as specified and directed. |
| 217 | Industrial surface/wall mounting socket 32 Amp 3P+N+E 4 pole with straight plug 32 Amp 3P+N+E and sockets enclosure cabinet 5 module including incoming MCB TPN 32 Amp, complete all as specified and directed.Note for Ser Item No 178 to 204:- All DBs, MCCBs/MCBs/RCBOs shall be of same make. |
| 218 | MS down rod for ceiling fanheavy duty 15mm nominal dia and 24\" long duly painted in matching colour with all fittings including cutting & threading and making hole with suitable size fan clamp, rubber reel, split pin, nut, bolts & washers, including taking down existing, complete all as specified and directed. |
| 219 | All as per item No. 205 here-in-before but 36\" long. |
| 220 | Disconnecting, sealing cable end, taking down, dismantling blades of existing ceiling fan of any size and removing fan and blades to MES store for reuse, painting with synthetic enamel paint by spraying after preparation of surfaces including filling cavities with filler, assembling and re-fixing the fan (after completion of civil work), connecting up and testing complete all as specified and directed. |
| 221 | Disconnecting, sealing cable end, taking down existing wall fans/exhaust fans of any size and removing fan to MES store, painting with synthetic enamel paint by spraying after preparation of surfaces including filling cavities with filler and re-fixing the same (after completion of civil work), connecting up with new three core flexible copper conductor cable of suitable size and testing complete all as specified and directed. |
| 222 | Disconnecting, taking down existing geyser of any size and removingto MES store, and re-fixing at the same place (after completion of civil work) including all requiredfasteners, nuts, bolts etc., connecting up and testing complete all as specified and directed. |
| 223 | CP connection (hot/cold) with CP brass adaptor 350 mm long for electric water heater of any capacity, fixed in repair complete all as specified and directed. |
| 224 | Sub main wiring with four single core, 1100 V grade, 16.0 Sqmm (nominal area) PVC insulated and unsheathed cables with stranded copper conductor FRLSH, drawn in and including non metallic rigid PVC concealed conduit medium duty with all standard accessories including one run of continuous PVC insulated unsheathed stranded copper conductor FRLSH cable 16.0 Sqmm (nominal area) as continuous earth conductor cable connected to earth dolly, complete all as specified and directed. Note(s):- (i) 4 run of 16.0 Sqmm main cable + 1run of 16.0 Sqmm for earth cable and conduit shall be measured as one unit/one Running Metre.(ii)Quoted rate shall also include cost of ISI marked corrugated flexible pipe of suitable size through which submains shall be drawn where concealed PVC conduiting is not possible. (iii)Extra length of cable / wire required for connection to MCCBs/RCBOs/ MCBs etc. shall not be measured. (iv)Quoted rate shall also include cost of making necessary cuting chases in walls/floor for concealing conduit and making good the disturbed surfaces in cement mortar (1:4) or PCC (1:2:4) as required to match with existing. |
| 225 | All as per item No.211 here-in-before but 10.0 Sqmm cable . |
| 226 | All as per item No.211 here-in-before but 6.0 Sqmm cable . |
| 227 | Sub main wiring with two single core, 1100 V grade, 4.0 Sqmm (nominal area) PVC insulated and unsheathed cables with stranded copper conductor FRLSH, drawn in and including non metallic rigid PVC concealed conduit medium duty with all standard accessories including one run of continuous PVC insulated unsheathed stranded copper conductor FRLSH cable 4.0 Sqmm (nominal area) as continuous earth conductor cable connected to earth dolly, complete all as specified and directed. Note(s) :- (i) 2 run of 4.0 Sqmm main cable + 1run of 4.0 Sqmm for earth cable and conduit shall be measured as one unit/one Running Metre.(ii)Quoted rate shall also include cost of ISI marked corrugated flexible pipe of suitable size through which submains shall be drawn where concealed PVC conduiting is not possible. (iii)Extra length of cable / wire required for connection to MCCBs/RCBOs/ MCBs etc. shall not be measured. (iv)Quoted rate shall also include cost of making necessary cuting chases in walls/floor for concealing conduit and making good the disturbed surfaces in cement mortar (1:4) or PCC (1:2:4) as required to match with existing. |
| 228 | All as per item No.212 here-in-before but 6.0 Sqmm cable . |
| 229 | All as per item No.212 here-in-before but 10.0 Sqmm cable . |
| 230 | Taking down of old existing unserviceable aluminium/copper submain wiring alongwith PVC/steel conduits of any size/make includingmaking necessary chases in walls/floorand making good the disturbed surfaces in cement mortar (1:4) or PCC (1:2:4) as required to match with existing complete all as specified and directed. |
| 231 | Earthing complete with GI earth plate electrode 600mm x 600mm x 6.0 mmthickburried directly in ground vertically to a depth not less than 2.25m deep below ground level with the top edge of earth plate at a depth not less than 1.5m below ground level connected to GI earth strip of size 25 mm x 4 mm by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 40mm dia GI pipe \"medium grade\", watering pipe 20mm dia GI pipe \"light grade\", GI wire meshed funnel, 15 cm alternate layers of charcoal and salt on all side of earth plate, filling of soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 100mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion and taking down of old items complete all as speciified and directed.Notes:- (i)Alternate bed of charcoal/salt to be done in 3 x 15 cm depth of salt and 3 x 15 cm depth of charcoal.(ii) PVC type DC insulators with screws, nuts, bolts etc shall be used in suface/ wall/floor for mounting of strip and distance between two insulator shall not be more than 1.0 m.(iii) PCC chamber shall be constructed 50 cm away from the edge of earth pit.(iv) Quoted rate shall include GI strip and protection pipe upto length 7.5m. Any further length required at site beyond 7.5m, shall be measured and paid separately.(v)Earth resistance shall be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone at no extra cost. |
| 232 | All as per Item No 214 here-in-before but GI earth strip of size 32 mm x 6 mm. |
| 233 | Maintenance free chemical earthingsystem to achive the earth value less than 1.0 ohm comprising the following components complete all as specified and directed:- (a) Copper earth rod of minimum size 17.2mm dia x 3 m long, ISI marked and IED62561-2:2018 certified. (b) Fixing of stranded copper strip of minimum size 25mm x 3mm, with connections to the earth electrode using exothermic welding.(c) Use of excel electrofill plus compound (IEC 62561 - 7: 2018 certified) mixed with soil having adequate moisture retention capability to a depth of approximate one metre from the bottom the pit. (Approx-40 kg).(d) Addition of carbon based RoHS & TCLP- certified electrofill compound (high conductivity), mixed with soil and water to form a slurry and filled upto 35 percent of the pit depth above the base compund layer (Approx-40 kg).(e) Add gravel at the top portion for easy passage of water and removal of air bubbles at the time of filling of electrofill plus excel compound for easy dissipation of fault current.(f) Fixing of PVC earth pit chamber of size 24 x 24 cm with M8 SS 304 grade nut and bolts.(g) FRP earthing display board 254x 380mm made out of plastic material showing information related to type of earthing, earthing result, due data of plastic hollow pipe of 20mm dia. (h) Advaced chemical earth compound to be used as per IS:3043 standard highly conductive electrafill. Notes:- (i)Quoted rate shall include excavation and earthwork.(ii) Quoted rate shall include copper strip upto 7.5m length. Any further length required at site beyond 7.5m, shall be measured and paid separately.(iii)Earth resistance shall be less than 1Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone at no extra cost. |
| 234 | Copper strip of size 20 x 3 mm for copper earthing continuity conductor or main earthing lead fixed to wall or batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to or any other indicated situation asrequiredusing PVC type DC insulators with screws, nuts, bolts etc at a distance not be more than 1.0 m complete all as specified and directed. Note: (i) Insulator for fixing of strip along the wall/roof should be placed not more than 1.00 m of interval. (ii) Two nuts & bolt should be provided on each joint. |
| 235 | Galvanised iron strip 25 x 4 mm as earth continuty conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or any other indicated situation for loop earthing etc. as required includingPVC saddles with necessary nut & bolt, screws etc. complete all as specified and directed by Engr-in-Charge. Note: (i) PVC type DC insulators for fixing of strip along the wall/roof should be placed not more than 1.00 m of interval. (ii) Two nuts & bolt should be provided on each joint. |
| 236 | All as per Item No 217 here-in-before but GI earth strip of size 32 mm x 6 mm. |
| 237 | All as per Item No 217 here-in-before but aluminium strip of size 25x3mm. |
| 238 | Clamps, bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and directed. |
| 239 | Microproccessor based central display unit with audible & visual Indications interfaces and regulated power supply and connections with minimum 10-15 beds/Toilets interconnections etc. as per site requirement. Separate numerical numbers will be displayed for patient Bed & Toilet. Displays remain in numeric upto 4 digit. Dimension of Display Unit not less than 285 mm x 230 mm x 75 mm and height of digit 0.75-01 inch, operated on 12 V DC in wired system and signal passes through low Vage wire complete all as specified and as directed. |
| 240 | Microprocessor based bedside calling unit mountable on recssed metal boxes, having 2 buttons CALL & RESET & having 1 LED indication for call status including connections etc as required with attached 2-3 feet long Cord having Push button switch module patient handsetand remains on patients bed. Dimension-85 mm x 85 mm 15 mm, operated on 12 V DC sources from Central Display Unit complete all as specified and directed. |
| 241 | Microprocessor based emergency Toilet Calling Unit mountable on recssed metal boxes, having 2 buttons CALL & RESET & having 1 LED indication for call status, having connections etc as required with attached 4 feet long Pull Cord. Dimension-85 mm x 85 mm 15 mm, operated on 12 V DC sources from Central Display Unit complete all as specified and directed. |
| 242 | Cat 6 cablefor connection of central displayunittobed sidecalling unit /emengency toilet calling unitcompleteallas specifiedand direccted . |
| 243 | 20 mm external dia, rigid non metallic PVC conduit, \"ISI marked\", inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddles, pipe hooks etc (for wiring), complete all as specified. |
| 244 | All as per item No. 223 here-in-before but 25 mm external dia. |
| 245 | All as per item No. 223 here-in-before but 32 mm external dia. |
| 246 | All as per item No. 223 here-in-before but 40 mm external dia. |
| 247 | 20 mm dia, corrugated flexible hose pipe, \"ISI marked\", inclusive of all fittings and fixing accessories such as couplers lock nuts, saddless, pipe hooks etc (for wiring), complete all as specified and directed. |
| 248 | All as per item No.224 here-in-before but 25 mm dia. |
| 249 | All as per item No. 224 here-in-before but 32 mm dia. |
| 250 | All as per item No.224 here-in-before but 40 mm dia. |
| 251 | Galvanised Iron (GI) perforated cable tray manufactured with hot-dip galvanised steel sheet not less than2 mm thick with galvanisation coating thickness not less than 65 microns of zinc for superior corrosion resistance, standard side rail height minimum 50 mm, width 150 mm and length of each tray not more than 2500 mm. Zinc coating shall be good quality and free from defects like bare patches, rust, or blisters/black spot. Perforation should evenly spaced holes for ventilation and cable management. Manufacturing processes, including punching, cutting, bending and welding shall be free from burrs. Trays are to be designed in a such way for butt-joint construction, using zinc-plated coupler plates, nuts and bolts for secured connections and hanging from ceiling with suitable size of hanging rod or angle ironor fixing on wall with suitable size cantilever angle frame and fittings/fixtures like nuts/bolts etc. The materials of steel shall be conforming to IS 2026 and cable tray system conforming to IEC 61537 complete including all accessories and fittings/fixtures all as specified and directed. |
| 252 | All as per item No225 here-in-before but 200mm wide and 50 mm deep and 2 mm thick |
| 253 | All as per item No225 here-in-before but 300mm wide and 50 mm deep and 2 mm thick |
| 254 | All as per item No225 here-in-before but 1000mm wide and 1000 mm deep and 3 mm thick |
| 255 | Bakelite/Hylam sheet 3mm thick to cover the existing electrical switch board/junction box in wall/floor without disturbing the existing surfaces fixed with screws etc. complete all as specified and directed. |
| 256 | Lamp holder, modular type PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 257 | S & F LED 7 W lamp in both colour of Red & Green as indicating lights for OTs complete all as specified and directed. |
| 258 | Disconnecting, sealing cable end, taking down existing complete split/window type ACs 1.5/2.0 TR capacity including all accessories/fittings and removing to MES store, re-fixing the same after servicing (after completion of civil work), connecting up and testing complete all as specified and directed. |
| 259 | Ceiling fans complete with aluminium blades, down rod and necessary fittings & fixtures accessories , 230 V 1200 mm sweep, rated power 28 W ± 10%, RPM 370 ± 10% , min air delivery 210 CFM, double ball bearing with five star rated with brushless direct current motor (BLDC) with super enamelled copper wire and class \"B\" insulation including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 260 | Exhaust fan 300 mm sweep with steel body, AC single Phase, 230 V, 50 Hz having double ball bearing, 1400 RPM, IP 55 protectionwith 03 blades, frame and louvers of suitable size complete all as specified and directed.Note: Making ncessary hole in wall is included in the scope of civil wk. |
| 261 | Rigid non metalic PVC flexible pipe 25 mm dia complete includingall connected fitting and fixtures complete all as specified and as directed. |
| 262 | Rigid non metalic PVC pipe 32 mm dia complete includingall connected fitting and fixtures complete all as specified and as directed. |
| 263 | Taking out of old existing complete Split/window type ACs 1.5/2.0 TR capacity (indoor & outdoor unit, copper piping, MS stand/support for outdoor unit etc)and removing to MES store, and refixing the same as per site requirement after servicing by water, cleaning of dust etc.(after completion of civil work), connecting up with new copper piping, new MS stand/support, new copper conductor cable of suitable size and testing complete all as specified and directed. Note: (i) Copper pipe and refilling of refrigerant gas shall be measured and paid separately. (ii) MS stand/support (heavy duty)for outdoor unit shall deemed to be included in the quoted rate. |
| 264 | Refrigerant copper pipe with necessary fittings/fixtures duly insulated with 13 mm thick closed cell elastometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported including interconnecting, of following sizes complete all as specified and as directed:- |
| 265 | 6.4 mm dia with 13mm thick nitrile rubber insulation |
| 266 | 9.53 mm dia with 13mm thick nitrile rubber insulation |
| 267 | 12.7 mm dia with 13mm thick nitrile rubber insulation |
| 268 | 15.86 mm dia with 13mm thick nitrile rubber insulation |
| 269 | Refrigerant Gas R22/R32/R-410a (As per site requirement) filling/charging by using pressure guages and equipment to measure correct pressure and temperature for the specific system, ensuring right amount of refrigerant to be filled complete all as specified and as directed. |
| 270 | Hi wall split type air conditioner indoor and outdoor unit, electric driven, 230 V, single phase, cooling capacity of 4500 K cal per hr (1.5 Ton) all waether (Hot & Cold) type,BEE 5 star rated with outdoor stand, with cordlessremote control unit and with in built air ioniser and Plasma filter for better indoorair quality complete all as specified and as directed. |
| 271 | All as per item No.237 here-in-before but 2.0 TR. |
| 272 | Voltage stabilizer automatic operation, single phase, naturally air cooled, indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 25% and capacity 5 KVA complete all as specified and as directed. |
| 273 | Commercial Air Curtain Unit for prevention of dust and conditioned air losess, 3-phase 415 V, 50 Hz, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and two coat of synthetic enamel paint (oven baked) with MS-CRC 18 gauge square perforated suction grills, aluminium alloy fans and single phase electric motor, nozzles etc. and accessories so as to produce1-1.5 m/s air velocity at floor level for door opening 52\" x 90\" including sensors complete all as specified and directed. |
| 274 | All as per item No.239 here-in-before but for door opening 58\" x 90\". |
| 275 | All as per item No.239 here-in-before but for door opening 70\" x 90\". |
| 276 | All as per item No. 239 here-in-before but for door opening 70\" x 96\". |
| 277 | Air ball Diffuser of size 2\" x 2\", white in colour made of aluminium, powder coated suitable for existing HVAC system including all connection complete all as specified and directed. |
| 278 | Air flow exhaust grills of size 300 mm x 1200 mm, white in colour, made of aluminium, powder coated suitable for existing HVAC system including all connection complete all as specified and directed. |
| 279 | Air fine filter with efficiencies 90% of particles 0.3 microns/Pre filter with efficiency 95% for 5-10 microns suitable for existing HVAC system for AHU washable mesh material, of size 610 x 610 x 300 mm, box type including allconnection complete all as specified and directed. (AHUs of AC Plant). |
| 280 | Design, Supply, Installation, Commissioning and Testing of minimum capcity 24 HP VRF (Heating & Cooling type) Air Conditioning PlantOutdoor type VRF Units air cooled, 100% inverter compressor based VRF system using R-410a refrigerant Gas, including first fill of refrigerant to meet desired conditions as below. The bidder shall submit complete design of Air Conditioning plant alongwith heat load calculation, size of pipe, size of AC duct, AHU,LT panel, Control cable, LT switchgear.LT Panel alongwith LT Cable from respective LT Panel at terrace to VRF/VRV unit is deemed to be included in scope of work.VRV/VRF system should be Top Discharged Modular Typeheat pump outdoorunits, equippedwithHighly Efficient Scroll, all Inverter Compressor(s), special heat exchanger, Y- branch as required, outdoor unit ms stand, auto check function for connection error, auto address setting, Refrigerant temperature control and capacity as mentioned below.VRV/VRF System shall be suitable for working on 50°C AmbientTemperature, with Refrigerant R-410A, Refrigerant Cooled PCB, Automatic Refrigerant Charge Function. The Outdoor unit shall have external static pressure of 75 Pa or more to achieve installation flexibility. Unit price shall be inclusive offull charge of Refrigerant Gas & Oil. The COP shall be minimum 7.1 at 50% load, at 35°C ambient temperature in cooling conditions. OEM to submit orignal capacity charts for proof.The manufacturer of ODU and compressor shall be same. i.e the make of compressor shall be identicle of the ODU.Nominal Capacity in HP as stated below:Design Parameter.(a) Temperature - 21°C ± 3°C (b) Relative Humidity - 55% (±5%) (c) Air Filtration Unit (99% down to 0.3 micron) (d) 100% Fresh Air. (e) Laminar Air FlowPLENUM with HEPA filter-01 for OT-01, Delivery suite-01, BMT (Main Room-02) & Renal Transplantation Room -01. (f)Fire Damper-01 for each Room. (g) Return Air Riser -04Nos for each Room.(h) Minimum positive pressure to be maintained 2.5 Pascal. (j)Time required to achieve design condition after switching on plant shall not exceed 30 minutes. Note. (i) Minimum 24 HP VRF plant working and 24 HP VRF plant as standby. (ii) The VRF/VRV unit working as well as standby shall be measured and paid separately.(iii)Pre dispatch inspection to verify the correctness of specification & genuineness shall be carried out by the rep of Accepting Officer in the factory premises of the manufacturer. |
| 281 | All as per item No 243 here-in-before but minimum capcity of 36 HP. Note. Minimum 36 HP VRF plant working and 36 HP VRF plant as standby. |
| 282 | All as per item No 243 here-in-before but minimum capcity of 12 HP. Note. Minimum 12 HP VRF plant working and 12 HP VRF plant as standby. |
| 283 | Design, Supply, Installation,TestingandCommissioningofminimum capacity of 12 HP Top Discharged Modular Typeheat pump (Heating & Cooling type) outdoorunits, equippedwithHighly Efficient Scroll, all Inverter Compressor(s), special heat exchanger, Y- branch as required, outdoor unit MS stand anti vibration pad, auto check function for connection error, auto address setting, Refrigerant temperature control and capacity as mentioned below.VRV/VRF System shall be suitable for working on 50°C AmbientTemperature, with full charge of RefrigerantR-410A, Refrigerant Cooled PCB, Automatic Refrigerant Charge Function. The Outdoor unit shall have external static pressure of 75 Pa or more to achieve installation flexibility.The COP shall be minimum 7.1 at 50% load, at 35°C ambient temperature in cooling conditions. OEM to submit orignal capacity chart. The manufacturer make of ODU and compressor shall be same complete all as specified and directed. |
| 284 | All as per item No 244 here-in-before but minimum capcity of 10 HP. |
| 285 | FLOOR MOUNTED DX AHU COMPATIBLE WITHVRV/VRF DX ODU Design, Supply, Installation, testing and commissioning offactory fabricated double skintype Air Handling Units 2 tier construction with recovery wheel as per specifications given below:-AHU Construction:- It shall be made out of 0.8 mm pre -coated Galvanised steel sheet outside & 0.8 mm plain steel sheet inside with 40 mm thick PUF insulation factory injected between them by injection moulding with density not less than 40 kg/Cum between them. Drainpan (made out of 1.2 mm stainless steel (SS Grade 304) sheet insulated with 19 mm think closed cell insulation nitrile rubber with thermal brake profile.Necessary foundation required & anti vibration pads shall be provided & cost for the same shallbe included in this item. Supply Air Stream:-1) Filter section consisting of pre filter, fine filter & HEPA filters(preferably at Terminals) in aluminum casing .Pre-filter section shall be with non woven synthetic media of 10 micron particle size with an efficiency of 90%, fine filter section will be with media of 3 micron particle size of efficiency 99%. HEPA filter section with media of 0.3 micron particle size with an efficiency of 99.997% at terminals. The quoted price shall also include HEPA filter, VCD, pressure differential indicator across Fine filters and HEPA filters with audible and visual alarms.2) Plug Fans with aerofoil profile blade centrifugal type with motor (VFD compatible) ,volume control damper and duct flexible connection. The supply fan shall be provided with variable frequency drive and input / output signal compatible to BMS system with TEFC drive motor of efficiency class suitable for MOTOR415± 10% volts, 50Hz, 3Phase AC supply suitably designed for variable frequency drive applications shall be as per actual selection meeting other technical requirements. |
| 286 | f3) 4/6/8 Row Deep DX Cooling Coil or as required meeting functional requirement, DX COIL 1 Working + 1 SBY4) Space for Humidifier of suitable capacity, complete with stainless steel SS-304 tank with levelswitch, piezotransducers duly interlocked with level sensors, Solenoid operated RO water makeup, water over flow protection, overflow and drain connections.5) Mixing/Discharge Plenum Section.6) 12kwStrip heater bank for monsoon reheating.7) COIL- DX Copper tubes .5mm thickand Aluminum fins 12-13 fin/inch, Coil size shall be selected for air velocity of 400 ft/minute.8) Link toVFD:- VFD designed for HVAC applications with built-in PID controller, control panel (keypad & display), IP-65 enclosure for use on standard centrifugal plug fans. The display should be in alpha-numeric characters and programming facility should be in user-friendly HVAC terminology. VFD’s shall have built-in harmonic filters. VFD panel to be provided with digital display showing electrical parameters like voltage, current and power consumption. VFD shall be installed in a dedicated external IP- 65 enclosure andthe inter connecting wires between driver and MCC shall be included. VFD cost included in this AHU price itself.9) Sound level 65 db. at the distance of 2 mtr.(maximum)10) Recovery Wheel Section with min 70% Efficiency.Coil Selection Parameters-Out side DB/WB-114F/83 inside DB/RH-69F -40-60% RHof following capacity complete all as specified and as directed:-Note:- Pre dispatch inspection to verify the correctness of specification & genuineness shall be carried out by the rep of Accepting Officer in the factory premises of the manufacturer. |
| 287 | FM-AHU minimum capcity of 18 TR / 6500 CFMESP 125mm +ISP as per OEM mm of W.C & 4900 return/Exhast fan with 40mm Static pressure DX COIL 1 x Working + 1 x standby. The Exhaust and Inlet should have a Heat Recovery Wheel for energy saving. (Operative delivery suite) |
| 288 | FM-AHU minimum capcity of 24 TR / 7500 CFM |ESP 125mm +ISP as per OEM mm of W.C & 5600 return/Exhast fan with 40mm Static pressure DX COIL 1 Working + 1 standby The Exhaust and Inlet should have a Heat Recovery Wheel for energy saving. (Delivery & PNC chamber) |
| 289 | FM-AHU minimum capcity of 27 TR / 8500 CFM |ESP 125mm +ISP as per OEM mm of W.C & 6400 return/Exhast fan with 40mm Static pressure DX COIL 1 Working + 1 standby The Exhaust and Inlet should have a Heat Recovery Wheel for energy saving. (NICU) |
| 290 | FM-AHU minimum capcity of 9 TR / 3200 CFM |ESP 125mm +ISP as per OEM mm of W.C & 2400 return/Exhast fan with 40mm Static pressure DX COIL 1 Working + 1 standby The Exhaust and Inlet should have a Heat Recovery Wheel for energy saving. (BMT & Renal transplantation Centre) |
| 291 | FM-AHU minimum capcity of 14 TR / 5000 CFM |ESP 30 +ISP as per OEM mm of W.C (BMT Complex) |
| 292 | FM-AHU minimum capcity of 23TR / 6800 CFM |ESP 30 +ISP as per OEM mm of W.C (Renal Transplantation Centtre) |
| 293 | FM-AHU minimum capcity of 10 TR / 3700 CFM |ESP 125mm +ISP as per OEM mm of W.C & 2800 return/Exhast fan with 40mm Static pressure DX COIL 1 Working + 1 standby The Exhaust and Inlet should have a Heat Recovery Wheel for energy saving. (Renal transplantation Centre). |
| 294 | Design, Suppy and installation of laminar Air flow (LAF) system direct flow from ceiling to floor. The flow passing over head and upper body of surgeon and assistant made out of aluminium powder coated made of 16 SWG, particle size retention of 0.3 mm, plenum size 3\"x6\" complete with Hepa filters of size 610 x 610 x 305 mm and SS perforated grilles having minimum 50% perfortation entry of air to housing shall be from side. Center of plenum shall be blanked off for provision of light (light not included), complete all as specified and as directed. |
| 295 | Design, Supply, installing, testing and commissioning of of IP 55 Variable Frequency Drive (VFD) for AHU, without deration at ambient temp 50 Deg, 100kA SC rating with inbuilt2 PIDs, C2 Class EMI Filter for 1st Environment, 5% Impedance DC Choke on both(+ve & -ve) limbs and shall be able to reduce THDi<32% @ 100% load & THDi<35%@ 75% load with input PF>0.96 @50% load as per IEC 61800-2. VFD shall have inbuilt 5 line Graphical & Alpha Numeric LCD Key Pad ( Power in kW, Energy in kWh, Run time in hours & feedback signals in HVAC units viz WC, PSI, GPM, °F, ft3/min, m3/h, L/h, L/s, bar, Pa, °C, M, ft., L/min, m3/min, “Hg, kPa, %) along with Hand Off Auto Keys & Real time clock with battery etc as per specification complete all as specified and directed. |
| 296 | Design, Supply, installation, testing and commissioning of 5 kwh wall / floor mountedHumidifier shall be Horizontal Floor standing with casters. The tank shall be constructed out of 1.2mm thick SS-304 Sheet. Control Panel made out of 1.2mm thick CRCA sheet duly powder coated.The Pan Type Humidifier shall have Water filter membrane and Air filter assembly, Level switches for upper and lower water level, Piezo transducers with Low water level protection., Solenoid operated Water makeup/Fill, Drain Valve ) Water Overflow connection with valve, Mist outlet point, Power Supply Suitable for 1Phase, 230VAC +5% regulated power supply upto 30LPH and above 30LPH suitable for 3Phase, 415VAC +5% Electrical Control Panel for Ultrasonic complete all as specified and directed. |
| 297 | Design, Supply, installation, testing and commissioning of digital display type BMS compatible thermostat / humidistat with controller for cool / heat application suitable for two/four pipe system & humidistat suitable for working with humidifier and dx coil control valves for various air handling Units, the thermostat shall have provision ofsetting of space temperature and display of the same, the humidistat shall have provision of setting space RH and display of the same including all accessories, mountings, wiring between thermostat & unit, terminations,20mm MS conduits, control cabling, MS Box etc. as required but excluding the control valves and humidifier, complete all as specified and directed. |
| 298 | Design, Supply, installation, testing and commissioning of automatic control for AHU unit (heating & cooling) consisting of modulating thermostat, having provision of setting of room temperature, setting of fan speed (High, Medium, Low) including all accessories, mountings, necessary wiring between thermostat & AHU unitcontrol cabling, MS Box etc. as required complete all as specified and directed. |
| 299 | MAIN INTELLIGENT PROGRAMMABLE CENTRAL CONTROLLER: Design, Supply, Installation, Testing and Commissioning of Central Controller, digital type oflatestgeneration suitable for all VRV/VRF equipments/AHU to operate, Monitor, Scheduling Programme, On/Off, Temperature Setting etc as per specification complete as required to operate all the indoor units, with BMS compatible complete all as specified and directed. |
| 300 | Design, Supply, installation , testing and commissioning of ODU Isolator of suitable capacity as per OEM design complete all as specified and directed. |
| 301 | Indoor Units : Hiwall Type.Design, Supply, Installation, testingandcommissioningof Hiwall TypeIndoor units equipped with corded remote, pre-filter, fan section with suitable static fan, multispeedmotor, coilsection with DX coil, outer cabinet,drain pan, insulation, pipe connections, variable evaporative temperature control etc. of various capacities as per specifications and drawings. All indoor Units have force shut option to connect with fire alarm or key card adaptor, so that the unit automatically stops in case of fire or key card removal, complete including all accessories and fittings/fixtures of following capacity all as specified and as directed:- |
| 302 | Hiwall Type Indoor Unitminimum capcity of 1.3 TR |
| 303 | Hiwall Type Indoor Unit minimum capcity of 1.6 TR |
| 304 | Hiwall Type Indoor Unit minimum capcity of 2.08 TR |
| 305 | Design, Supply installation testing and commissioning of AHU Kit for AHU which shall be supplied with necessary expansion kit and control box with wired remote to connect with VRV outdoor units, complete including all accessories and fittings/fixtures all as specified and directed. |
| 306 | Design, Supply installation testing and commissioning of Refnets/Headers/ODU Connecting kit of required size as per OEM design complete including all accessories and fittings/fixtures all as specified and directed. |
| 307 | Drain Piping: Design, Supply, installation, testing and commissioning of PVC (Minimum 15 Kg/Sqcm pressure rated) Drain Water Piping with fittings (elbows, tees, reducers, sockets etc.), supports, jointing complete including all accessories and fittings/fixtures all as specified and directed, Nominal Diameters of Pipes as under: |
| 308 | 32 mm ( with 9 mm thick Class- O XLPE) |
| 309 | 40 mm ( with 9 mm thick Class- O XLPE) |
| 310 | 50 mm ( with 9 mm thick Class- O XLPE) |
| 311 | Copper Refrigerant Piping with Insulation for VRV & Split System: Design, Supply, installation, testing, commissioning of Copper Refrigerant piping for VRV / VRF& Split System complete with fittings, supports, jointing, insulation with class O -XLPE, gas charging & commissioning, all accessories and any other item required to make the system complete, Nominal Dia in mm OD as under, complete all as specified and directed:- |
| 312 | 41.3 ( with 19 mm thick insulation ) |
| 313 | 34.9 ( with 19 mm thick insulation ) |
| 314 | 31.6 ( with 19 mm thick insulation ) |
| 315 | 28.6 ( with 19 mm thick insulation ) |
| 316 | 25.4 (with 19 mm thick insulation) |
| 317 | 22.2 ( with 19 mm thick insulation ) |
| 318 | 19.1 ( with 13 mm thick insulation ) |
| 319 | 15.9 (with 13 mm thick insulation) |
| 320 | 12.7 ( with 13 mm thick insulation ) |
| 321 | 9.5 ( with 13 mm thick insulation ) |
| 322 | 6.4 (with 13 mm thick insulation) |
| 323 | CONTROL CABLING. Design, Supply & fixing control cum transmission wiring PVC 2 core x 1.5 sqmm copper conductor through suitable size of PVC conduits on surface between indoor units and outdoor units and indoor units and remote controllers including necessary making hole as per site requirement complete all as specified and directed. |
| 324 | Ducting. Design, Supply, Installation,Testing and Commissioning of 22 gauge aluminium ducting materialas per technical specifications and drawings complete with all fitting, accessories, dampers, vanes, take offs, canvas connections transformation. The rate shall include suspension and supporting arrangement with angle iron and dash fasteners. Ducts shall be straight and smooth and shall have neatly finished joints. All joints shall be made air tight using 5mm neoprene rubber gaskets, and/or RTV-sealed, or soldered as specified. The gasket will be fixed with a suitable adhesive to the flange. Changes in dimensions and shape of ducts shall be gradual. Curved elbows, unless otherwise approved, shall have a center line radius equal to one and a half times the width of the duct. Air turns shall be installed in all abrupt elbows and shall consist of curved metal blades or vanes, arranged to permit the air to make the turn without appreciable turbulence. Turning vanes shall be invariably provided at all turns and grille-collars. Splitters and dampers shall be provided at all branches/tapings 0.6 mm PCGI Frame construction shall be used, complete all as specified and directed. Note : Duct insulation shall be measured and paid for separately. |
| 325 | All as per item No 259 here-in-before but 20 Gauge Aluminium ducting material. |
| 326 | Dismantling of exisitng old unserviceable ductcomplete and making good the disturbed surfaces to match with exisitng surfaces/walls/floors including necessary brickwork/plastering, old ducting materials to be deposited in MES stores yard complete all as specified and directed. |
| 327 | Grills and Diffusers: Design, Supply, fixing, testing and commissioningof Extruded Aluminium powder coated supply air linear grills without volume control dampers and mounting frame, finished in approved shade and defusercomplete all as specified and directed. |
| 328 | Design, Supply, fixing, testing and commissioning of Anodised black aluminium volume controls dampers for supply air as per OEM design/ recommendation complete all as specified and directed. |
| 329 | Design, Supply, fixing testing and commissioning of Fire Dampers as per Fire rating standards made of GI sheet metal as per OEM design/ recommendation complete all as specified and directed. |
| 330 | Design, Supply, installing and testing of extruded aluminium Airlouverswith bird screen in accordance with as per OEM design/ recommendation complete all as specified and directed. |
| 331 | Design, Supply, installation, testing and commissioning of Actuator for fire damper complete all as specified and directed. |
| 332 | 19 mm thick nitrile duct insulation with aluminium foil, non-fibrous, fire retardant, closed cell, tri-dimensional chemically crosslinked polythylene foam, conforming to class \"0\" for fire propagation and class \"1\" for surface spread of flame & factory laminated aluminum foil complete all as specified and directed andincluding the following:(a)Cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage.(b)Applying rubber based adhesive CPRX compound.(c)Sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) Securing the insulation with and including mechanically fastened nylon/steel straps of size 12 mm/50 mm at maximum intervals of 1.2 m. |
| 333 | Acoustic insulation of initial part of supply air ducting with 15 mm thickopen cell class \"0\", porous, non-fibrous, non-dusting, and non-irritant insulation, conforming to BS 476 Parts 6 & 7 standards complete all as specified and directed. |
| 334 | Fire retarded poreless canvas for outlet connection of the AHUs, UL Classified and LA Approved complete all as specified and directed. |
| 335 | Design, supply, installation, testing and commissioning of outdoor type (to be mounted at terrace) LT Feeder pillar box made out of 3.15 mm thick CRCA sheet totally enclosed weather dust and vermin proof as per IS, CPRI Approved with front opening suitable locking arrangement having copper bus bar of 600 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables, made out of 50 mm x 50 mm x 6 mm angle iron grouted in PCC 1:3:6 in foundation, 30 cm above ground level. Panel shall have PLC base control with digital LED display and IP 55 protection. LT Panel comprising the following complete all as specified and directed:-Note : Cost of necessary internal wiring from bus bar to ACB/MCCBs/MCBs/ RCBOs/ Enclosure connections etc shall be deemed to be included in the unit rate. Incoming:(a)MCCB 400 Amp 4P, 415 V 25 kA microprocessor based adjustable thermal and fixed magnetic type, Ics= 100% Icu=100% Icw for 1 sec with spreader - 01 No. (b)Phase indicating LED Lamp Red/Yellow/Blue - 03 No (c) SP MCB 2 A - 03 No (d) Digital Multifunction meter with CT- 01 No(Voltmeter & Ammeter) with selector switch.Outgoing:(a) 63 Amp 4P RCBO, 415 V 10 kA - 16 No (For 16 No ODU). (b) 32 Amp 4P RCBO, 415 V, 10 kA - 06 No (For Pan type Humidifier & AHU unit). (LT Panel for NICU Complex) |
| 336 | Design, supply, installation, testing and commissioning of outdoor type (to be mounted at terrace) LT Feeder pillar box made out of 3.15 mm thick CRCA sheet totally enclosed, weather dust and vermin proof as per IS, CPRI Approved with front opening, suitable locking arrangement, having copper bus bar of 300 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables, made out of 50 mm x 50 mm x 6 mm angle iron grouted in PCC 1:3:6 in foundation, 30 cm above ground level. Panel shall have PLC base control with digital LED display and IP 55 protection. LT Panel comprising the following complete all as specified and directed:- Note : Cost of necessary internal wiring from bus bar to ACB/MCCBs/MCBs/RCBOs /Enclosure connections etc. shall be deemed to be included in the unit rate. Incoming:(a)MCCB 320 Amp 4P, 415 V 25 kA mricroprocessor based adjustable thermal and fixed magnetic type, Ics= 100% Icu=100% Icw for 1 sec with spreader - 01 No. (b)Phase indicating LED Lamp Red/Yellow/Blue - 03 No (c) SP MCB 2 A - 03 No (d) Digital Multifunction meter with CT- 01 No(Voltmeter & Ammeter) with selector switch.Outgoing: (a) 63 Amp 4P RCBO, 415 V 10 kA - 11 No (For 11 No ODU). (b) 32 Amp 4P RCBO, 415 V, 10 kA - 08 No (For Pan type Humidifier & AHU unit).(LT Panel for BMT Centre) |
| 337 | Design, supply, installation, testing and commissioning of outdoor type (to be mounted at terrace) LT Feeder pillar box made out of 3.15 mm thick CRCA sheet totally enclosed weather dust and vermin proof as per IS, CPRI approved with front opening, suitable locking arrangement, having copper bus bar of 300 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables, made out of 50 mm x 50 mm x 6 mm angle iron grouted in PCC 1:3:6 in foundation, 30 cm above ground level. Panel shall have PLC base control with digital LED display and IP 55 protection. LT Panel comprising the following complete all as specified and directed:- Note : Cost of necessary internal wiring from bus bar to ACB/MCCBs/MCBs/ RCBOs/Enclosure connections etc shall be deemed to be included in the unit rate.Incoming:(a)MCCBs 200 Amp 4P, 415 V 25 kA mricroprocessor based adjustable thermal and fixed magnetic type, Ics= 100% Icu for 1 sec with spreader-01 No. (b)Phase indicating LED Lamp Red/Yellow/Blue - 03 No (c) SP MCB 2 A -03 No (d) Digital Multifunction meter with CT- 01 No(Voltmeter & Ammeter) with selector switch.Outgoing: (a) 63 Amp 4P RCBO, 415 V 10 kA-07 No (For 07 No ODU). (b) 32 Amp 4P RCBO, 415 V, 10 kA-02 No (For Pan type Humidifier & AHU unit).(LT Panel for Renal Transplantation Centre) |
| 338 | Design, supply, installation, testing and commissioning of compertmentalised outdoor type LT Feeder piller box made out of 3.15 mm thick CRCA sheet dulypowdercoatedand comprises with DigitalVoltmeter,Ammeter,LED indicating lights, Stop/manual /Auto selector switch in each, outgoing current operated single phase preventer. Panels shouldcomply IEC 61439& internal arc IEC 61641.Thestarters should havepotentialfreecontacts for connectionto Building Automation System. The panel shall include contactors /over load relay with built in single phase protection / Time delay relay for delayed automatic start of the motor. All panels shall have spare NO/ NC Contacts for BMS applications as required. Panel shall be IP-54 protection, including connecting incoming and outgoing cables necessary PCC 1:3:6 in foundation and made out of 50 mm x 50 mm x 6 mm angle iron grouted at ground above 30 cm from ground level. LT Panel comprising of the following complete all as specified and directed(LT Panell to be mounted in terrace):-Incoming:(a)MCB TP 16 Amp, 415 V, 10 kA, \"C\" Curve - 02 No. (b)MCB TP 32 Amp, 415 V, 10 kA, \"C\" Curve - 01 No. (c)Phase indicating LED Lamp Red/Yellow/Blue - 03 No (d) SP MCB 2 A - 03 No as control MCBs(e) Digital Multifunction meter with CT- 01 No(Voltmeter & Ammeter) with selector switch.Outgoing: (a) 02 x DOL Starter withMCB TP 10 Amp, 415 V, 10 kA, C Curve (MotorDuty), suitable for power contactor, ON/OFFpushbuttonsand ON/OFF/TRIP indicating lights,A/Mselectorswitchforlocal/remoteoperations,CToperatedDigitalAmmeter,suitableNO&NC Potential free contacts, SMPS , DC Relays as required for Interlocking /ON-OFF on receiving of fire signal from fire control panel/Control Module,O/Lrelaywith inbuilt single phase preventor , selector switches etc. as required. (for 3.5 KW Motor). (LT Panel for AHU) |
| 339 | Low Tension (LT)PVC sheathed, electric power cable, cross sectional area 10Sqmm 4 core copper conductor 1100volts grade with end termination complete with brass compression gland, crimping thimbles etc, laid in cable tray, alongpolesorpassing through pipe etc, complete all as specified and directed. (for AHU to VRF/VRV)Note :Pre dispatch inspection of the cable to verify the correctness of specification & genuineness of cable will be carried out by the rep of Accepting Officer in the factory premises of the manufacturer. |
| 340 | All as per serial Item No.273 here-in-before but cross sectional area 6Sqmm 4 core copper. |
| 341 | All as per serial Item No. 273 here-in-before but cross sectional area 1.5Sqmm 4 core copper. |
| 342 | All as per serial Item No.273 here-in-before but cross sectional area 2.5Sqmm 3 core copper. |
| 343 | All as per serial Item No. 273 here-in-before but cross sectional area 1.5Sqmm 3 core copper. NOTE FOR Air Conditioning work:-(i) Contractor/bidder shall submit complete design of New AC plant of VRF/VRV and hi wall split AC comprising heat load calculations, size of pipe, size of AC duct, AHU, LT Panel, control cable, LT switch gear duly vetted by IIT/NIT for approval of AO, before commencement of work. (ii) Contractor/bidder will be responsible for performance guarantee of complete AC plant to achieve the inside design conditions round the clock throughout the year with overall COP of the system not less than 3 (Three). (iii)Contracor shall visit the site before bidding. (iv)All the new Air Conditioning equipment are to be installed on the roof where sufficient space is available. Additional accessories required for successful operation of units are deemed to be included in overall cost quoted. (v) Rates quoted by the contractor shall be for complete finished work including cost of all labour, material, scaffolding, finishing as required with tools, plants, cartage, lift, taxes, tollage, octroi, royalties etc. All works shall be executed as per drawings and instructions of Engineer-in-Charge/GE and shall include the supply and installation at site of all the equipment, ancillary materials as specified and all such items what-so-ever which may be required to fulfill the intent and purpose as laid down in the drawings. All materials shall be as per ISI specification and with IS certification marked wherever applicable. The material shall beapproved by GE before incorporation in the work. |
| 344 | (vi)Design of LT Panel, LT Cable, Earthing upto Control Panel of each New Plant shall be submitted by contractor for approval of GE. Cost of all designs are deemed to be included in overall cost.(vii) Central AC of existing NICU & delivery suite shall be delocated before connecting up new unit. Existing AC plant shall be synchronised all as specified and directed by Engineer-in-Charge. Nothing extra shall be payable on this account. (viii) Item of HERMATICALLY SEALED DOOR as designed for OT shall be measured & paid for separately. (ix)Complete system shall be tested for a period of 24 hours (Monsoon season) by rep of AO in presence of Engineer-in-Charge, rep of CWE and rep of Users. On successful testing of system, same shall be operated by the contractor for a period of six months within overall cost quoted. (x) The existing rooms are of approx height 3.20 m. Existing spaces at NICU complex shall be provided Air Conditioning from existing AC Plant for which all necessary modification to existing system shall be carried out by the Contractor. This item shall be measured and paid separately against relevant Item on this schedule. |
| 345 | Electric water heater (Geyser) storage type, steel body with MS glass lined inner tank and heating elements upto 2 KW, capacity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece, inbuilt or portable resudual current protection device (16 Amp 30mA ), 3-pin plug top 16 Amp and hot & cold water connection fittings complete including all accessories and fittings/fixtures all as specified and directed. Note - Water supply pipe line upto inlet & outlet of Geyser shall be measured and paid separately. |
| 346 | Med Eqpt & MGPSSurgeon\"s Pendant Double Arms, heavy duty ceiling mounted, aluminium powder coated body, adjustable shelf with two rails one on each side: 3 number, 6 trays and one drawer doublemoveable arm (any combination), with total coverage of minimum 1800 mm. Surgeon Pendant system shall have the facility to provide convinient positioning of medical equipment, medical gas terminal units, electrical and specially service in OT. Pendant shall be facilitated with load carrying capacity of minimum 180 Kg. The arm shall rotate up to 330° and ability of horizontal and vertical movement with electromagnetic brakes. Vertical movement shall be motorised. Pendant shall be provided with 10 No electrical 6/16 Amp Power Socket having independent switch. Pendant shall be supplied with outlets and probes as Oxygen (Oշ) and MA4: 01 each, Vaccum outlets : 2No, Air (7 Bar) outlet: 01 No and COշoutlet: 01 No, adjustable shelf with two rails 01 No each side 3 numbers, Data socket RJ-45: 02 No, IV fluid pole with 2 hooks: 01 No (Pole shall be capable of stacking 4 syringe pumps) as approved by the GE complete including all accessories and fittings/fixtures all as specified and directed. Standard & Classification: The pendant shall be European CE certified with 4 digit notified body number/USFDA/ETL/UL/BIS certified/listed under medical devices directive with complied to ISO-9001,CE,14001,13485,WHO & 45001. Make: WIESPL/Drager/Altos/ Stryker/Steris |
| 347 | Heavy duty Anaesthesia\"s Pendant System, Double moveable arms (any combination) with total coverage of minimum 1800 mm with load carrying capacity of minimum 180 Kg and shall have electromagnetic brakes. Each arm shall be capable of minimum 330° of rotation. Each arm shall have ability of horizontal movement and vertical movement. Vertical movement shall be motorised. Pendant system shall have the facility to provide convinient positioning of medical equipment, medical gas terminal units, electrical and specially service in OT. The pendant shall be ceiling mounted and shall have provision to mount at least 01 x monitor. Pendant shall be provided with 10 No of electrical 6/16 Amp power socket having independentswitch. Pendant shall be supplied with outlets and probes as Oxygen (Oշ) outlets: 02 No, Vacuum outlet: 02 No, Nitrous Oxide(NOշ) outlet: 01 No, Air (4 bar) outlets: 2 No, AGSS outlet: 01 No with electrical 6/16 Amp Power Sockets: 10 No. The pendant shall be supplied with adjustable shelf with two rails one on each side: 3 No, IV Fluid Pole with 4 hooks: 01 No and Data socket RJ-45: 02 No as approved by the GE complete including all accessories and fittings/fixtures all as specified and directed. Standard & Classification: The pendant shall be European CE certified with 4 digit notified body number/USFDA/ETL/UL/BIS certified/listed under medical devices directive with complied to ISO-9001,CE,14001,13485,WHO & 45001. Make: WIESPL/Drager/Altos/ Stryker/Steris |
| 348 | IP Based two way Audio-Video Communication System consisting of one loudspeaker, one hand mic and one wireless collar microphone with echo cancellation, installed within the operating room, suitable cable material and a patch panel shall be offered as per the position of the loudspeaker.Design Parameter: The system shall have in built IP based Uncast Video Streaming facility with zero latency in order to transmit live surgery on Hospital network/Seminar/ Conference/lecture theatre/Auditorium. It shall consist of two microphone input, auxiliary input for connecting external audio/video devices like HD TV for presentationand shall be intigrated with operation theatre control panel complete including all accessories and fittings/fixtures all as specified and directed. |
| 349 | Horizontal Bed Head Panel having minimum length 1.0 meter, maximum length 1.25 meter, efficient, safe & robust design in extruded aluminium section, smooth curved surfaces and choice of base colour and fascia plates, shall have integrated rail system to mount accessories. The handwall system shall be constructed of aluminium extrusions joined together to form a carcass to suit the particular application. Unit shall be factory made & assembled for electrical and mechanical components. Design Parameter: The panel shall be designed to accommodate the gas outlets for Oxygen- 02 No, Medical Air 4 Bar- 02 No & Vacuum- 02 No. It shall be consist of minimum 16 No Power Sockets with independent switches 6/16 Amp.It shall be supplied with integrated rail for mounting accessories. Each Bed Head Panel shall be supplied with medical and electrical outlets pre-fitted and internally wired complete including all accessories and fittings/fixtures all as specified and directed. Standard & Classification: ISO-9001,CE,14001,13485,WHO & 45001. Make: WIESPL/Drager/Altos/ Stryker/Steris |
| 350 | Touch type OT Control Panel: Digital display panel consisting of minimum of 30\" flat Monitor with computer fixed flush with the OT wall for PACS viewing. Touch Screen Control Panel must show temperature, humidity in the operating theatre and must be able to be set on required temperature of air as well as light intensity. Design Parameter: It shall have the function of clock and stopwatch consisting of Digital clock: (hh:mm:ss), Elapsed Clock: (hh:mm:ss), Start-stop-reset; Anesthesia Clock: (hh:mm:ss) & Start-stop-reset. This shall be a single panel or uniformly combined individual panels to suit the ambience. The Digital clock and the elapsed time indicator: Both shall have large LCD display for easy visibility from a distance. The digit height approximately 60mm. The Medical gas alarm shall indicate high and low gas pressures for each gas service. Present in the OR including vacuum. This shall be supported by audible alarm also. The panel shall have an alarm mute (fault annunciation) facility. The sensors (pressure switches) shall be at the nearest isolation valve. Control for general lighting: ON/OFF and dimming controls organized in groups to provide uniform illumination. Control of the operating light major and satellite and camera control (ON/OFF and intensity control) shallbe provided. Hand free telephone set with memory shall be located at one side. Temperature and humidity control for the room connected to the AHU. (Adjustable from the panel). There shall be a provision of temperature adjustment from the controller (temp adjustment of ±5°C to be achieved within 5 minutes).Digital room pressure indicator in cm of HշO or equivalent (signal from pressure sensor). HEPA filter bank differential pressure indicator. Provision for inbuilt recording of OT camera. The control panel shall be able to integrate with HIS (Hospital Information System)/BMS. Shall have provision for data processing. Shall interface with Isolated power supply systems to get the alarms/alerts. The control panel shall be able to display the isolation panel alarm conditions alongwith MGPS Alarms.IP Based two way Audio-Video Communication System shall be integrated with the control panel, complete including all accessories and fittings/fixtures all as specified and directed. Make: WIESPL/Drager/Altos/ Stryker/Steris |
| 351 | Operating List Board made of ceramic having magnetic properties, flush mounted to the wall of the operating room. The laminated board shall be bonded to 40 mm high density fire board sheet for additional rigidity.The board have minimum size 1000 mm x 700 mm x 60 mm complete including all accessories and fittings/fixtures all as specified and directed. Make: WIESPL/Drager/Altos/ Stryker/Steris |
| 352 | Sensor based No touch Dispenser, fully automatic, completely touch-free operation, the non-contact Intelligence to avoid Bacteria cross infection, operated by Wall-mounted roof and dark button. Easy to top filling, also can be hung on the wall. Single out the liquid 0.8~1Ml, avoid unnecessary waste. Non-Drip and more clean-Innovative non-drip design eliminating waste and counter-top mess, large easy to fill opening, Globally recognized design validated by user across the world, Accommodates 500ml or 1-liter bottles. The dispenser shall work with both 4-C type batteries or 6 V 1 Ampere DC Adapter complete including all accessories and fittings/fixtures all as specified and directed. Design Parameter: Sturdy and maintenance free design with long life. No nebulizing, no aerosol vapour and no wastage. Compatible with all leading hand disinfectant solutions. Designed to prevent excess liquid spill on surface. Collecting dish with absorbent media absorb more liquid and remain enclosed. No more touching of taps, towels, bottles of Disinfectants solutions. Designed and engineered for high frequency usage. |
| 353 | High precision ICU pressure monitor system fitted at entrance of the ICU to view positive pressure inside the ICU, positive and negative pressure cubical shall be fitted with separate ICU pressure monitoring system complete including all accessories and fittings/fixtures all as specified and directed. Make: WIESPL/Drager/Altos/ Stryker/Steris |
| 354 | Ward Vacuum Unit light weight, compact consisting of regulator, 600 ml reusable collection jar made of unbreakable polycarbonate material and fully auto clavable at 121°C temperature, wall bracket for mounting the jar assembly on the wall. The vacuum regulator with instant ON / OFF switch shall be infinitely adjustable and the vacuum gauge shall indicate suction supplied by the regulator. Safety trap shall be provided inside the jar to safeguard the regulator from overflowing. The Ward Vacuum Unit shall be certified by ISO-9001/CE/14001/ 13485/ WHO/45001 complete including all accessories and fittings/fixtures all as specified and directed. Make: WIESPL/Drager/Altos/ Stryker/Steris |
| 355 | OXYGEN SYSTEM.Oxygen outletswith matching stainless steel probe/adaptor complies with HTM 02-01, BSEN 737, BS 5682:1998, and C11 complete including all accessories and fittings/fixtures all as specified and directed. |
| 356 | Anodised aluminum body and control knob oxygen flow meter with humidifier bottle, 0-15 L/min standard flow rate and BSEN 737 probe complete including all accessories and fittings/fixtures all as specified and directed. |
| 357 | Oxygen H.P. anstistatic tube, white color complete including all accessories and fittings/fixtures all as specified and directed. |
| 358 | NITROUS OXIDE SYSTEM.N20 outletswith matching stainless steel probe/adaptor complies with BS EN 737, HTM 02-01 and C11 complete including all accessories and fittings/fixtures all as specified and directed. |
| 359 | N20 H.P. tube with antistatic core, french blue complete including all accessories and fittings/fixtures all as specified and directed. |
| 360 | COMPRESSED AIR SYSTEM.Medicalair MA-4 outletswith matching stainless steel probe/adaptor complies with BS EN 737, BS 5682:1998, HTM 02-01 and C11complete including all accessories and fittings/fixtures all as specified and directed. |
| 361 | Surgical air MA-7 outlets with matching stainless steel probe/adaptor complies with BS EN 737,BS 5682:1998 HTM 02-01 and C11complete including all accessories and fittings/fixtures all as specified and directed. |
| 362 | Compressed air HP antistatic tube, black colourcomplete including all accessories and fittings/fixtures all as specified and directed. |
| 363 | VACUUM CENTRAL SYSTEM.Vacuum outlets with matching stainless steel probe/adaptor complies with BS 5682:1998 HTM 02-01and C11 complete including all accessories and fittings/fixtures all as specified and directed. |
| 364 | Vacuum regulator with direct probe:High suction-direct complies with BS 5682:1998 HTM 02-01 and C11 complete including all accessories and fittings/fixtures all as specified and directed. |
| 365 | Theatre Vacuum Unit 1 regulator with direct probe complies with BS 5682 : 2015 HTM 02-01 and C11 complete including all accessories and fittings/fixtures all as specified and directed. |
| 366 | Vacuum collection jar size 2000 ml of polysulphone with lid complies with HTM 02-01 and C11 complete including all accessories and fittings/fixtures all as specified and directed. |
| 367 | Vacuum colletion jar size 1000 ml of polysulphjone with lid, complies with HTM 02-01 and C11 complete including all accessories and fittings/fixtures all as specified and directed. |
| 368 | Vacuum HP antistatic tube, yellow colour complete including all accessories and fittings/fixtures all as specified and directed. |
| 369 | MEDICAL GRADE COPPER PIPES, half hard drawn, tempered seamless phosphorous deoxidized, non-arsenic and degreased conforming to latest BS, EN 13348 : 2008,KITE MARK Certification is must, chemical compostion CU-DHP to ISO 1190-1 CW024A as per EN 1412, Cleanliness : Maximum total carbon content 0.20 mg/dm2, Packaging : Each tube individually end capped, tube bundles polythene wrapped and sealed, copper tubes stamped with 0.9 mm thick (a) Kite mark, (b) EN 13348, (c) Tamper complete including all accessories and fittings/fixtures all as specified and directed of following size:- Make: Mexflow/Mandev/Rajco/Mitesh Tube |
| 370 | 15mm (OD) |
| 371 | 22mm (OD) |
| 372 | 28mm (OD) |
| 373 | AVSU MODULE. Area Valve Unit Module with single service valve box, area alarm fitted in module, fully complies and meets withHTM 2022, HTM 02-01 and C11, and duly CE marked with CE No specified on it, easy to operate and reliable, supplied pre wired and with pressure switches terminal board and medgas area alarms, the steel chassis & cover shall be power coated, emergency assess lock mechanism on each door.The whole of the AVSU shall be identified for its gas by an engraved trafolite label riveted to the cover, and a gas identity labelattached to the pipe work.The NIST connection forming part of the stub pipes shall incorporate a metal seal to avoid the possibility of degradation over time, complete including all accessories and fittings/fixtures all as specified and directed. |
| 374 | 5 Services O2, N2O, Air-4, Air -7 , Vacuum (22,22,22,.22,22mm) |
| 375 | 3 Services O2, Air-4, Vacuum (22,22,22 mm) |
| 376 | 2 Services O2, Vacuum (22,22mm) |
| 377 | Lockable Line valves15mm lockable line valve, complete including all accessoriesall as specified and directed. |
| 378 | 22mm lockable line valve, complete including all accessories all as specified and directed. |
| 379 | 28mm lockable line valve, complete including all accessories all as specified and directed. |
| 380 | X-RAY View Box LED Type.X-ray viewer LED light with option of vertical as well as horizontal covering must be flushed into operating theatre wall. The dimming function should be provided. LED type flat panel X-ray viewing panel shall be supplied. This shall be a 3 panel viewing screen. LED X- Ray viewer to provide flicker free luminance for the film viewing purpose with option of vertical as well as horizontal covering. Mounting shall be flush with the wall to avoid dust accumulation and growth of organisms between wall and panel. Body shall be of extruded aluminum powder coated black with bacteria and disinfectant resistant finish. Dimming electronic control shall be enclosed at the bottom of the cabinet. Proper spring loaded film clip with rollers shall be provided to hold the films firmly and to remove the film without scratches. The diffuser on the front panel shall be a uniformly lit screen. Each panel should be able to illuminate films up to 14”x17” size ( Total 03 x Panel), complete including all accessories and fittings/fixtures all as specified and directed. Make: WIESPL/Drager/Altos/ Stryker/Steris |
| 381 | Peripheral light 56 W LED type, clean room luminaires, minimum size 2 feet x 2 feet,luminaries covermade of highly resistant, disinfectant proof laminated safety glass/acrylic with stylish fine-grained surface. The body of light shall be made of highly specular anodized aluminium with powder coated. The fittings shall be uniformly and aesthetically distributed on ceiling to provide uniform illumination. Light shall not be interfered when green mode endoscopy is performed. Light shall be protected with IP 65 . Electronic driver shall Powered by an independent Isolated, SELV Output electronic LED dimmable driver (SMPS based constant current supply) with Output Short-circuit protection and with suitable capcity of dimmer for controling the light ilumination by increasing/decreasing as per site requirement. Features. Optics shall High transmittance polystyrene opal diffuser for glare free symmetric light distribution. Light source shall High efficiency long life LED package in integral module with lumen efficacy of 140 lm/W and viewing beam angle of 120° to ensure better uniformity and ilumination to be controlled by a suitable capcity of dimmer as per site requirement, complete including all accessories and fittings/fixtures all as specified and directed. Make: WIESPL/Drager/Altos/ Stryker/Steris |
| 382 | Double Dome Ceiling Mounted OT Light with HD Camera on Centre of Main Dome, separate arm for HD Screen and Audio-Video Cabling to outside the Operating Theatre. Surgical light double dome LED ceiling mounted OT LED Light. The control equipment placed inside the operating room. The life of LEDs must be at least 50000 hr. Each dome shall have a multi-lens atrix for shadow free, homogeneous, pure white, natural light field. It shall be flat scaled light body designed for Laminar Air Flow Ceilings. It shall have a IIR free Illumination. Colour Rendering Index (CRI) not less than 95,Gamut Area Index (GAI) not less than 80, Light field diameter (at 1 m distance, without change in intensity) : 20 cm to 28 cm (±10% ). The illumination intensity shall be at least 1,60,000 Lux at 1 m distance for each dome. Colour Temperature : Minimum range 3800°K-5000°K (±10%) variable. It shall have adjustable focus system. It shall have light dimming range 5% to 100% (Minimum). Working range minimum 750 mm to 1100 mm (±10%). It shall be with dual controls for all controllable parameters. One at dome assembly and down and another, wired/wireless remote on the wall. It shall be possible to adjust the dome at any position, have easy maneuverable, free up and down and swing movements and free rotatable at any angle. It shall be supplied with 9 numbers of additional sterile handles. Every light petal must have a provision to be individually replaceable services onsite. It shall be with CE marks or US FDA approved.Make: WIESPL/Drager/Altos/ Stryker/SterisContd.. |
| 383 | Specification of HD Camera: Minimum capacity of 1080p/i, integrated in light camera system at the centre of one principal dome of this light system/third arm in order to capture images and video sequences of the open cases, Signal to noise ratio (S/N Ratio) shall be more than 50 dB, CCDD/CMOS: 1/3\" or 1/1.2\", Optical Zoom minimum 10X, Digital Zoom minimum 12-15X, Video output: HD, DVI, S-Video and composite video. White balance and gain: Automatic/Manual. OT lihgt and integrated Camera shall have a control through touch type digital panel of the control equipment placed inside the operating room complete all as specified and as directed.Note: All items which are mounted on ceiling like pendants, Double Dome OT LED light with HD Camera, Peripheral lights and cleanroom luminaries should be compatible to each other. |
| 384 | Recording System and PACS (Picture Archiving & Communication System) Monitor. Recording system capacity of minimum one TB storage space, Data cable for communication from both pendants and monitors shall be laid down upto outside of OT in a patch port for future expansion for all OTs where is no integration. Patch Panel for power and signal shall be laid down for minimum 40\" LED Monitor at wall of OTs. Record shall be capable of recording video from other sources like microscopes, endoscopes etc suitable provision for the same shall be made. Monitor shall be medical grade and integrated with hospital PACS. The contractor shall do the necessary coordination with hospital authorities for connecting the PACS monitor to the hospital PACS. If hospital/institute PACS is not available, contractor shall terminate all PACS monitor connection to switch loacated in OT Corridoor & Waiting area for further connection by the hospital. Monitor shall be flush mounted with suitable frame in OT wall. Frame shall be openable/serviceable for service. Make: WIESPL/Drager/Altos/ Stryker/Steris |
| 385 | HD LED Flat Panel Monitor.HD minimum 40\" LED flat Panel Monitor, medical grade high-definition progressive scan flat-panel monitor with ceiling mounted spring arm suspension to support high definition/HDTV progressive scan images and shall be able to support and display DVI/HDTV, RGBHV, S-Video, Composite video signals. Aspect ratio 16:9/16:10. Resolution : 1920 x1080 or better, IP 54 regulations. The flat panel suspension shall be ready with the cables for integration of high-definition digital (DVI/HDTV), RGBHV (High Resolution), SVHS (S-video), composite video signals to travel from the various sources of video like endoscopic camera, room camera, in-light camera, high definition flat panel monitors, while assuring apivore solution/signal. Monitor shall be capable of displaying from other sources like endoscope, microcope etc., complete including all accessories and fittings/fixtures all as specified and directed.Make: WIESPL/Drager/Altos/ Stryker/Steris |
| 386 | FIRE FIGHTING: FIRE PUMPS, EQUIPMENT, PIPING, VALVES & ACCESSORIES Supplying, installing, testing and commissioning ofelectrical driven Centrifugal End Suction pump having bronze impeller, SS Shaft, Mechanical Seal fitted with suitable capacity IE2 motor coupled on common base plate and suitable for automatic/manual operation consisting of the following, complete including all accessories and fittings/fixtures all as specified and directed :-Horizontal mounted End Suction type fire pump having cast iron body, bronze impeller, stainless steel shaft & capable of delivering 2850 LPM against a total head of 88 m complete in all respect.Squirrel cage, induction motor TEFC type suitable for 415V + 10%, 3 phase, 50 Hz, AC supply, of suitable HP rating for the above pump with synchronous speed withflexible coupling and coupling guard.Common bed plate for mounting pump and motor fabricated out of mild steel channel as per manufacturer\"s recommendation with heavy duty Anti Vibration pads (4 No, heavy duty).Drain Pipe with Valve (50 mm dia)Coupling and coupling guard for direct coupling of pump and motor.( Make: Kirloskar/ Crompton/ Mather & Platt )(Location: Existing Plant Room for fire pump and sprinkler pump) |
| 387 | Supplying, installing, testing and commissioning of Diesel Engine driven Centrifugal End Suction Pump [Stand by pump] with bronze impeller, SS Shaft, Mechanical Seal fitted with suitable capcity diesel engine at minimum 1800 RPM coupled on common base plate and suitable for automatic/manual operations consisting of the following, complete including all accessories and fittings/fixtures all as specified and directed :- (a) Horizontal mounted end suction type fire pump having cast iron body, bronze impeller, stainless steel shaft & capable of delivering 2850 LPM against a total head of 88 m complete in all respect.(b) Radiator cooled diesel engine of suitable BHP for the above pump complete with standard accessories & suitable cooling system as described in specifications.(c) Common base platefor mounting pump & engine of requisite strength manufactured out of M.S. channelsas per manufacturer\"s recommendation with heavy duty Anti Vibration pads.(d) Coupling & coupling guard for direct coupling of engine & pump.(e) 200 litre capacity diesel oil storage tank fabricated from 2 mmthick MS plate, provided with inlet, outlet, overflow, vent, drain connections, filling connection & level indicator. Tank shall be mounted on a suitable steel structure 60 cm from GL. Tank shall be provided with epoxy coat from inside & two or more coats of synthetic enamel paint outside & steel structure over a coats of red oxide primer after preparations of surface. (f) 24 V 180 AH lead acid battery (12 V - 2 No) with boost/Trickle charger for starting the engine automatically complete as required. (g) Provision for starting of Engine automatically in case of power failure at the time of fire. Diesel engine shall be designed conforming to CPCB-IV or latest guidelines.(Location - Plant Room) |
| 388 | Supplying, installing, testing and commissioning of Electrically driven Centrifugal End Suction Jockey pump, Bronze Impeller, SS Shaft, Mechanical seal fitted with suitable capacity IE2 Motor coupled on common base plate and suitable for automatic/manual operation consisting of the following, complete including all accessories and fittings/fixtures all as specified and directed.:- (a) Horizontal mounted end suction jockey pump having cast iron body, volute bronze impeller, stainless shaft capable of delivering 180 LPM against total head of 88 m complete in all respect.(b) Squirrel cage induction motor suitable for 415 + 10%V, 3 phase, 50 Hz, AC supply of suitable HP rating for the above pump with synchronous speed with flexible coupling and coupling guard.(c) Common bed plate for mounting pump and motor fabricated of mild steel channel as per manufacturer\"s recommendation with heavy duty 4 No Anti-Vibration pads of Cushy foot mount.(d) Drain pipe with valve (25 mm dia) (Location - Plant Room) |
| 389 | Supplying, installing, testing and commissioning of Centrifugal end suction pumpBronze impeller, SS shaft, Mechanical seal fitted with suitable capacity IE2 Motor coupled on common base plate and having 900 LPM capacity at 35 m head, pressure not less than 3.5 kg/sq cm at the top most hydrantsuitable for fire fighting and conforming to IS- 12469-1988 with totally enclosed drip proof squirrel cage induction motorwith bronz impellers, pressure gauge, pressure switch complete to operate on 3 phase, 415 V, 50 Hz including PCC foundation block and making connection with tail / tapper pieces to connect supply and delivery pipes including pipes and also including fabricated MS common base plate of suitable size coupling guard air vent with pessure guages on delivery side and pipe etc. complete including all accessories and fittings/fixtures all as specified and directed. Note for 304 to 307.(a) Rate shall deemed to be included of Engine accessories, Engine oil, collant, suitable battery with battery lead and construction of 200 Ltr Fuel Tank and fuel pipe as per site requirement/manufacturer recommendation. (b) Rate shall deemed to be included the cost for taking out/dismantling of existing complete fire pump and depositing to MES store. |
| 390 | Supplying, installing, testing and commissioning of Cubical type floor mounted fire control panel fabricated from 2 mm thick MS sheet dully painted with stove enamaled finish of approved shade and comprising One osolation fuse switch unit complete all as specifed and as directed. |
| 391 | Supplying, installing, testing and commissioning of Pressure switch of approved make for Hydrant pump, jockey pump and Diesel Engine Driven pump including necessary wiring and cut off valve up to central panel complete including all accessories and fittings/fixtures all as specified and directed. (Location Plant Room) |
| 392 | Air cushioning tank (Air vessel ) 250 mm dia x 2000 mm high with dished top, made of minimum 6mm thick MS Pipe/Plate complete with 20mm dia brass air valve (ball type), 20mm dia brass stop valve, pressure gauge with brass stop cock, nipple, tees, elbows complete including all accessories and fittings/fixtures all as specified and directed. |
| 393 | Supplying, fixing, testing and commissioning of Heavy grade 200 mm dia MS pipe, IS : 3589 marked with all necessary fittings like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc. welded or screwed joints as required including fixing the pipe with necessary structural supports (for delivery/suction manifold relating to the pumps) including painting the pipes two coats of synthetic enamel paint over a coat of red oxide primer after preparation of surfaces, including cutting holes in existing wall/floors and making good the disturbed surface/wall/floor, complete including all accessories and fittings/fixtures all as specified and directed. [ Location : Plant room].Note: MS clamps/supports, nuts, bolts etc as required shall be measured and paid separately. |
| 394 | All as per Item Ser No 311 above but 250 mm dia (6.3 mm thick) |
| 395 | Supplying, fixing, testing and commissioning of 150 mm dia 6.35 mm thick flanged end basket 300mm height of Y-type strainer made from MS body with bottom and top removable flanges with nuts, bolts etc havingfilteration area at least 6 times the cross sectional area of the pipe complete including all accessories and fittings/fixtures all as specified and directed. |
| 396 | Supplying, fixing, testing and commissioning of CI Sluice valve 150 mm dia, PN 1.6 rating, conforming to IS : 1538 with flanges, nuts, bolts and washers complete including all accessories and fittings/fixtures all as specified and directed.Make: Zoloto/Sant/Shakti/Ceasel |
| 397 | All as per Item Ser No 313 above but 100 mm dia |
| 398 | All as per Item Ser No 313 above but 80 mm dia |
| 399 | Supplying, fixing, testing and commissioning of CI Butterfly valve 150 mm dia, PN 1.6 rating, conforming to IS : 13095 with flanges, nuts, bolts and washers complete including all accessories and fittings/fixtures all as specified and directed.Make: Zoloto/Sant/Shakti/Ceasel |
| 400 | All as per Item Ser No 314 above but 100 mm dia |
| 401 | All as per Item Ser No 314 above but 80 mm dia |
| 402 | All as per Item Ser No 314 above but 65 mm dia |
| 403 | All as per Item Ser No 314 above but 50 mm dia |
| 404 | Supplying, fixing, testing and commissioning of Dual plate CI non-return valve 150 mm dia complete with nuts, bolts and washers complete including all accessories and fittings/fixtures all as specified and directed. Make: Zoloto/Sant/Shakti/Ceasel |
| 405 | All as per Item Ser No 315 above but 100 mm dia |
| 406 | All as per Item Ser No 315 above but 80 mm dia |
| 407 | All as per Item Ser No 315 above but 65 mm dia |
| 408 | All as per Item Ser No 315 above but 50 mm dia |
| 409 | 100 mm dia Burden type, Stainless Steel dial type pressure gauge (in Pump Room) including brass isolation valve and pipe having caliberation of 0-15 Kg/cm² complete including all accessories and fittings/fixtures all as specified and directed. |
| 410 | Burden type Stainless Steel dial type 100 mm dia pressure gauge with caliberation 0-10 Kg/cm² with brass isolation valve and pipe complete including all accessories and fittings/fixtures all as specified and directed. (For each internal Fire hose cabinet) |
| 411 | MS exhaust pipe class \"C\" 150 mm dia for Diesel engine exhaust including fittings like flanges, bends, reducers, etc. 50 mm thick fibre wool insulation aluminium cladding, 26gauge, fixing of silencer connections at engine exhaust, necessary supports, back filling, cutting and making good, bird proof and weather-proof flap complete including all accessories and fittings/fixtures all as specified and directed. |
| 412 | Design, supply, installation, testing and commissioning of Outdoor type (to be mounted at terrace) LT Feeder pillar box made out of 3.15 mm thick CRCA sheet totally enclosed, weather dust and vermin proof as per IS, CPRI Approved with front opening, suitable locking arrangement, having copper bus bar of 1000 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables, made out of 50 mm x 50 mm x 6 mm angle iron grouted in PCC 1:3:6 in foundation, 30 cm above ground level.Panel shall have PLC base control with digital LED display and IP 55 protection. LT Panel comprising the following complete all as specified and directed:- Note: Cost of necessary internal wiring from bus bar to ACB/MCCBs/MCBs/ RCBOs/Enclosure connections etc. shall be deemed to be included in the unit rate. Incoming:(a)ACB 630 Amp 4 P, 415 V 36 kA mricroprocessor based adjustable thermal and fixed magnetic type, Ics= 100% Icu=100% Icw for 1 sec with spreader-01 No. (b)Phase indicating LED Lamp Red/Yellow/Blue - 03 No (c)SP MCB 2 A - 03 No (d)Digital Multifunction meter with CT- 01 No(Voltmeter & Ameter) with selector switch.Outgoing (a) MCCB 250 A, 4 Pole, 415 V 25 kA microprocessor based adjustable thermal and fixed magnetic type, Ics= 100% Icu=100% Icw for 1 sec with spreader - 02 No. (For Eletric driven fire pump).(b) MCCB 32 A, 4 Pole, 415 V 16 kA microprocessor based adjustable thermal and fixed magnetic type, Ics= 100% Icu=100% Icw for 1 sec with spreader-02 No (For jockey pump). Contd... |
| 413 | (c) 04 x DOLstarterwill becompletewithsuitable capcity of TPN, 415 V, 10 kA, C Curve (MotorDuty), suitable for power contactor, ON/OFFpushbuttonsand ON/OFF/TRIP indicating lights,selectorswitchformannual/automaticoperations,CToperatedDigitalAmmeter,suitableNO&NC Potential free contacts, SMPS , DC Relays as required for Interlocking/ON-OFF on receiving of fire signal from fire control panel/Control Module, O/Lrelaywith inbuilt single phase preventor, selector switches etc. as required. (For 02 x fire pump & 02 x Jokey pump). Note(s): (a) Audio visual alarm & indications having disconnect/reset facility with a range of 1/2 km.Annunciator to be provided in the Fire panel with hooterand acknowledge, test and reset PBs. The indication shall come on when electrical driven pump set fails to start on pressure drop or when there is power failure during pressure drop.(b) Facility for mode of selection switch to be in auto mode and manual mode.(c)Protection failure & control cabling. (d) Automatic/mannual indication for ON/OFF/ TRIP shall be provided through potential free contact.(e) Provision of automatic/manual starting/stopping of engine shall be provided.(f) Wiring from pressure switch to starter. (g) Set of control system to make the system automatic as per functional requirements. (h) Provision for starting the diesel engine fire pump with battery charger for trickle & boost charging. The diesel engine driven fire pump shall start automatically in the event of pressure drop beyond preset limit on mains failure or failure of electrical driven pumps to start for each Diesel Engine Pump.(LT Panel Plant Room) |
| 414 | FIRE HYDRANT SYSTEM Supply, Installation testing & commissioning of Black Mild Steel heavy duty 25 mm dia pipes conforming to IS : 1239 Part-I including cutting, threading, welding & all fittings like flanges, tees, elbows, bends junctions, reducers, ball valves etc. welded or screwed joints, clamps structural steel supports (as per TAC norms) or as per site requirement including one soft coat of red oxide paint and two coat of synthetic enamel paint shall be done after surface preparation.Make : TATA/JINDAL/SWASTIK |
| 415 | All as per Item No 320 above but here-in-before but 32 mm Nominal Bore |
| 416 | All as per Item No 320 above but here-in-before but 40 mm Nominal Bore |
| 417 | All as per Item No 320 above but here-in-before but 50 mm Nominal Bore |
| 418 | All as per Item No 320 above but here-in-before but 65 mm Nominal Bore |
| 419 | All as per Item No 320 above but here-in-before but 80 mm Nominal Bore |
| 420 | All as per Item No 320 above but here-in-before but 100 mm Nominal Bore |
| 421 | All as per Item No 320 above but here-in-before but 150 mm Nominal Bore |
| 422 | Painting a coat of red oxide primer after surface prepation on upto 150 mm dia of MS pipe before laying in trenches/floor/wall/surface includingand wrapping conforming to IS-10221 foranti rust protection complete all as specified and as directed. |
| 423 | Water flow switch made of brass material, single pole double throw (SPDT) type, 230V, AC supply, operating pressure 10kgf/cm² or 150 psi, IP 65 protected including necessary internal connection, controls wiring etc. completeall as specified and directed. Make: System Sensor/Denforce/Inforce |
| 424 | S.S. single headed ISI marked oblique pattern hydrant landing valve with 80mm dia flanged inlet & 63 mm dia female outlet complete with gun metal cap and GI chain twist release type plug and all accessories conforming to IS : 5290-1983 Type A (For internal + external hydrant) complete including all accessories and fittings/fixtures all as specified and directed. Make: Minimex/Ceasfire/MEC |
| 425 | 63 mm dia 15 m long non-percolating flexible hose (RRL- type A) as per IS : 636. Type A with S.S. male & female instantaneous type coupling (IS 903), complete including all accessories and fittings/fixtures all as specified and directed. |
| 426 | 63 mm dia stainless steel branch pipe with 12.5 mm nozzleIS 903 marked, complete including all accessories and fittings/fixtures all as specified and directed. Make: Minimex/Ceasfire/MEC |
| 427 | Wall mounting swinging type first aid fire hose reel with drum, hanging bracket, 30 mtr length and 20 mm dia high pressure hose reel tubing with gun metal (GM) shut off nozzle having 5 mm dia orifice. The hose reel shall be conforming to IS : 884-1985. 25 mm dia M.S. pipe connection from Riser to hose reel, sockets, nipples, elbows and 25 mm dia ball valve. Drum shall be fixed on adjoining wallthrough anchor fasteners / cement concrete block as per site requirement and specification for couplings branch pipe nozzle used in hose reel tubing shall conforming to IS 8090(For internal hydrant system) complete including all accessories and fittings/fixtures all as specified and directed. Make: Minimex/Ceasfire/MEC |
| 428 | Weather proof standard fire hose cabinet (750 mm x 600 mm x 300 mm deep) for yard hydrants made of 1.6 mm thick MS sheet powder coatedhaving single or double opening glazed (4.0 mm thick glass) shutter including necessary locking arrangement by allan key, stove enamelled Fire red finish with \" Fire Hose\" marked on front, suitable for housing 2 No Hose pipe, 1 No branch pipe & nozzle spanner, complete including all accessories and fittings/fixtures all as specified and directed. |
| 429 | Air release valve 25 mm dia, working pressure upto 150 psi, PN 25 type, IS 14845 marked, made of stainless steel corrosion resistance with necessay fittings/fixtures etc. to be installed at riserscomplete all as specified and directed. Make: Zoloto/Sant/Shakti/Ceasel |
| 430 | Gun-metal gate valves, with iron wheel head, screwed down high pressure, screwed both ends for iron pipe of 25mm dia bore, at risers, complete all as specified and directed. Make: Zoloto/Sant/Shakti/Ceasel |
| 431 | Light duty, non pressure NP-3, RCC pipe, 300 mm dia for protection of underground hydrant pipe at road crossings including collar pieces and filling inside of pipe with sand complete complete all as specified and directed. Note: Excavation & earthwork, PCC foundation shall be measured and paid for separately. |
| 432 | Drain pipe for wet riser with 50 mm dia and 2 m long MS heavy duty pipe, hard chrome plated stainless steel ball valve with PTFE seat/seal, conforming to ISO 17292, BS EN, pressure rating 25 kg/cm²g working in temperature rating 25°C to 150°C complete including all accessories and fittings/fixtures all as specified and directed. |
| 433 | Supplying, Installation, Testing and Commissioning ofPendent Through Type of Sprinkler headsUL listed and FM approvedcomplete withfusible glass capsule of 5 mm dia suitable for horizontal/ pendenttype sprinkler\"s head of 68 degree temperature with powder coated complete all as specified and as directed. |
| 434 | Supplying, Installation, Testing and Commissioning of flexible minimum 1 meter long sprinkler connection pipe,UL listed and FM approvedcomplete 5 mm dia suitable for horizontal / pendent through type sprinkler\"s head including necessary connection complete all as specified and as directed. |
| 435 | Supply, erection, testing and commissioning of fire brigade draw off connection conforming to IS : 4038-1986 with 150 mm Non return valve/ strainer including necessary accessories and fittings/fixtures, painting the words \"FIRE BRIGADE DRAW OFF\" on the box complete all as specified and directed. |
| 436 | Supply, erection, testing and commissioning of FOUR WAY fire brigade inlet connection to wet riser system comprising 4 No 63 mm dia Gun metal NRV, 1 No powder coated weather proof standard hose box suitable for accommodating the above components, fabricated out of 1.6 mm thick MS sheet with central opening, glazed front incluiding all necessary accessories and fittings/fixtures, painting the words \"FIRE BRIGADE DRAW OFF\" on the box complete all as specified and directed. |
| 437 | FIRE DETECTION AND ALARM SYSTEM: Intelligent AnalogueMulti-Criteria (combination of smoke and heat) Detector with special algorithms to utilise information from both smoke and heat sensing elements to ensure high level of immunity to false alarms without compromising genuine alarm sensing performance, programmable multiple smoke senstivity level and 9 modes of operation, bi-directional in-built short circuit isolator to protect against cable faults, dual bi-colour LED\"s with 360° view of status, auto- addressable/ electronically addressed, utilises fully digital communication addressable protocol with high noise rejection (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device). Approved by LPCB for EN 54-5, EN 54-7, & EN 54-17 standard complete including all accessories and fittings/fixtures all as specified and directed. |
| 438 | Intelligent Analogue Heat Detector with inbuilt Isolator/Isolator Module and two programmablethermal senstivity level, the two level corresponds to rate-of-rise (A1R) and fixed temperature class BS. Bi-directional in-built short circuit isolator to protect against cable faults, bi-colour LED\"s with 360 degree view of status, auto- addressable/ electronically or hard addressed, utilises fully digital communication addressable protocol with high noise rejection (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device), Independently certified as complying with requirements ofUL 7th Edition Standard, complete including all accessories and fittings/fixtures all as specified and directed.(For pantry) |
| 439 | Motorised Auto Align 50-120 range conventional Beam detector Ul Listed with required Dual Input module, Control Module and power supply complete including all accessories and fittings/fixtures all as specified and directed. |
| 440 | Intelligent Analogue addressable resettable Manual Call Point, Bi-Colour LED for local indication of device status, single action operation, reset to normal condition using special reset key, clearly visible alarm flag in the activated state (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device), independently certified as complying with requirements ofUL 7th EditionStandard complete including all accessories and fittings/fixtures all as specified and directed. Make : Advanced/ Hochiki / Argus |
| 441 | Supply, installation, testing & commissioning of UL approved Isolator Base with Module fully monitored for short circuit Ability to detect short circuit conditions, Design shall be compatible with with analog sensor, inbuilt LED indication upon short circuit condition, security locking tab for tamper protectioncomplete including all accessories and fittings/fixtures all as specified and directed. Make: Hochiki/Honewell/Scheider/Siemens |
| 442 | Supply, Installation, Testing & Commissioning of Addressable (SLC) loop powered Wall Sounder with inbuilt Isolator Module andBeacon for providing Audible and Visual Alarms in response to the output signal from the control panel as per OEM recommendations. SLC having 32 selectable tone and adjustable sound level, maximum output volume@ 1m distance 100 dB(A), output tone frequency range 440 Hz to 2900 Hz,Visual alarm device output frequency 0.5 or 1Hz.Independently certified as complying with requirements ofUL 7th Edition Standard complete including all accessories and fittings/fixtures all as specified and directed. Make: Hochiki/Honewell/Scheider/Siemens |
| 443 | Supply, Installation, Testing & Commissioning of Intelligent Analogue Single Input/ Monitor Module with inbuilt Isolator/ Isolator Module , microprocessor controlled interface module for Flow switch monitoring and other input purposes, with in-built short circuit isolator, 360 degree view LED\"s for local indication of device status, auto-addressable/ electronically or hard addressed, utilises fully digital communication addressable protocol with high noise rejection (For Detectors/ Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device), independently certified as complying with requirements ofUL 7th Edition Standard complete including all accessories and fittings/fixtures all as specified and directed. |
| 444 | Supply, Installation, Testing & Commissioning of Intelligent Analogue Relay Output/ Control Module with inbuilt Isolator/ Isolator Module, for control of third party/auxiliary devices using single V-free change-over relay contact, with in-built short circuit isolator, Bi-colour LED\"s for local indication of device status, auto-addressable/ electronically or hard addressed, utilises fully digital communication addressable protocol with high noise rejection (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device), independently certified as complying with requirements ofUL 7th Edition Standard, complete including all accessories and fittings/fixtures all as specified and directed. |
| 445 | Supply, Installation, Testing & Commissioning of Active Network Repeater Panel (Including network card) withbacklit (840 Character/ 240x64 pixel resolution/10\" Touchscreen) graphical LCD display; incorporates function buttons for Silence, Mute, Resound, Reset and Disable/Enable; Networked for system display and control, in-built network card to network with compatible addressable panel(s) and repeater panel(s), fully on-site programmable via alphanumeric keypad or configuration software, panel housing meets min IP30 ingress protection classification finished in RAL 7035, complete including all accessories and fittings/fixtures all as specified and directed, for the following:- :- |
| 446 | Graphic LCD Repeater with 10 Inch touch Screen |
| 447 | Active Network Repeater Panel |
| 448 | Supply, Installation, Testing & Commissioning of 4loop Analogue Addressable Fire Alarm Control Panel UL-10th Edidion Certified expandable via plug-in loop driver boards, loop current minimum 500mA per loop, dual flash based microprocessor, supports to connect minimum 126 devicesin each loop via fully digital communication protocol, equipped with an inbuilt printer, white backlit display (840 Character/240x64 pixel resolution/10\" Touchscreen) graphical LCD Display with atleast 6 lines of information, 200 zones (soft zones) per panel and 2000 zones on network, fully programmable via alphanumeric keypad or configuration softwarewithout using any kind of dongle/licence or special cable, dediacted USB and RS-232 serial port for direct or PC connection, shall support 5000 historic events and 500 fire alarm events. Panel shall be equipped with in-built multi-meter for live monitoring of loop current, earth Voltage, loop Voltage etc. Panel should support peer to peer networking between panels capable of networking 32 nodes on standard networking and 200 nodes on secured network. Panel housing shall meet min IP30 ingress protection classification finished in RAL 7035. The panel shall be capable of providing output for BMS/ SCADA software through optional Modbus/ Bacnet module (The System cost shall be included of all necessary cards, modules, Panel enclosure, CPU and associated accessories to complete the system design), complete including all accessories and fittings/fixtures all as specified and directed. |
| 449 | Supply, Installation, Testing & Commissioning of PC based Graphics Software With AX/BMS Box, ability to import floor plans, Drag and drop from device tree to maps, real time graph of device analog values, unlimited map linking, display and control for multiple panels, Event history can be viewed, filtered and exported (The cost shall include required PC along with accrssories for running the software), complete including all accessories and fittings/fixtures all as specified and directed. |
| 450 | Supply, installation, testing & commissioningof copper wire 2 X 1.5 Sq.mm fire survival type wire for detection and alarm systemcomplete all as specified and as directed. ( Polycab / KEI / Plaza) |
| 451 | FIRE EXTINGUISHERSPortable type COշ based aluminium body fire extinguisher, capacity 4.5 kg with used/unused indicator, squeeze grip type store pressure, fire rating of different class of fire 55B, PED (Pressure Equipment Directive) approved, dishcharge mechanism Squeeze Grip Type only, ISI marked (IS: 15222)complete including all accessories and fittings/fixtures all as specified and directed. |
| 452 | Portable Aqueous Film Forming Foam (AFFF) based 9 litre capacity store pressure type Fire-Extinguisher, Fire Rating 3A & 144 B as per IS: 2878and 13A & 144 B as per EN Standard, EN approved, PED (Pressure Equipment Directive) approved and CE marked, bulk range throw shall be minimum 5 m, complete including all accessories and fittings/fixtures all as specified and directed. |
| 453 | Portable ABC multipurpose mono-ammonium phosphate (MAP), nitrogen pressurised type fire extinguisher, capacity 6 kg, ISI marked (IS: 15683) complete including all accessories and fittings/fixtures all as specified and directed. |
| 454 | Trolley mounted fire extinguisher, AFFF Mechnical foam type (gas pressurized), ISI marked (IS: 15683) Capacity 50 liter complete including all accessories and fittings/fixtures all as specified and directed. |
| 455 | Portable COշ fire extinguisher of capacity 22.5 kg, ISI marked (IS: 2878), flat base including valve discharge hose of not less than 10mm dia including initial fill with COշ gas confirming to IS 307-1966 and filled to filling ratio of not more than 0.367, complete including all accessories and fittings/fixtures all as specified and directed. |
| 456 | PANEL PROTECTIONSupply, Installation, Testing & Commissioning of Automatic High Pressure Fire Suppression Cylinder and DHP Valve COշ Gas Based, Cylinder CCOE/PESO approved, Brass Valve, integrated pressure reducing valve, rupture disk safety for the high-pressure side Boosting Disc: 250 Bars, spring-loaded safety valve for the low-pressure side; Integrated position control for ball valve : Open / Close. The required COշ gas quantity is arrived as per the volume of the respective panels to be protected. Following standards and rules and regulations shall be applicable: (a) IS: 6382 - 1984 CodeofPracticeforDesignandInstallationof Fixed Carbon Dioxide Fire Extinguishing System.(b) NBC Part-IV 2016 National Building Code Part-IV: Fire Safety System. (c) IS: 7285 - 2004 RefillableSeamlessSteelGasCylinders-Specification. (d) IS: 307 – 1966Carbon dioxide for the following:- |
| 457 | 4.5 Kg capacity COշ, DHP Valve Assembly with automatic valve, push in connector for tube, 4.5 Kg COշ gas & mounting bracket, (with provision for manual activation), complete including all accessories and fittings/fixtures all as specified and directed. |
| 458 | All as per Item No 356 here-in-before but 6.8 Kg capacity, 6.8 Kg CO2 gas. |
| 459 | Supply, Installation, Testing & Commissioning of Linear pneumatic heat Detection Tube for automatic fire detection and suppression system made by special modified Polyamide (PA), Color Red RAL300/ Black, High grade quality, Inner diameter 4mm, outer diameter 6 mm, Melting Point approx. 222°C, Burst Pressure 100 bar at 20°C, Temperature range: - 40°C to + 80°C, Working Pressure 20 Bar at 20°C, Burst Temperature with dry Nitrogen at 16 bar pressure approx 100°Cto 110°C, complete including all accessories and fittings/fixtures all as specified and directed. |
| 460 | Pressure Switch to monitor Pressure drop in the tube, switch point 5 Bars, Switch Type SPST, Normally Open, Electric Rating: 120/240 VAC-375 VA, 24 VAC-125 VA, Open at 160 psi y-7, Close 185 psi y-5, Pressure switch + adaptor / 5bar / M10x1 / SPST, complete including all accessories and fittings/fixtures all as specified and directed. |
| 461 | Supply, Installation, Testing & Commissioning of End of Line adapter with Pressure gauge for Automatic fire suppression tube used for fitting at the end of the tube for pressurizingand re-pressurizing the tube includes check Valve, Pressure Gauge and fitting to connect to sensor tubing. Tube connection 6mm, length 2.77\"/71mm, Gauge scale: 0-20 bar, brass Fitting (plated/unplated), Stainless steel, Elastomeric Sealings, Copper Nickle plated, Temperature range TS - 20°C to till + 60°C, made as per PED Pressure Equipment Directives, complete including all accessories and fittings/fixtures all as specified and directed. |
| 462 | Supply, Installation, Testing & Commissioning of End of Line Plug for Automatic fire suppression tube used for fitting at the tube end to terminate the point. Tube connection 6mm, Length 1.13\"/29mm, brass nickel plated fitting with Elastomeric sealings, Temperature range TS -20°C to till + 60°C, Maximum working pressure 25 Bars, made as per PED Pressure Equipment Directives, complete including all accessories and fittings/fixtures all as specified and directed. |
| 463 | Supply, Installation, Testing & Commissioning of T-Connection, Brass Nickle plated, for 4x6 mmSensor Tube, quick and easy dismantling using special tool, working pressure 15 bars at 150°C Temperature, temperature range- 40°C till + 80°C, Elastometric Sealings, External Diameter tube 6mm, complete including all accessories and fittings/fixtures all as specified and directed. |
| 464 | Supply, Installation, Testing & Commissioning of Control Unit for controlling each system, to get a signal continuously indicating the CO2 quantity inside the cylinder (for monitoring and maintenance), complete with buzzers and electronic hooters, including all necessary accessories + electrical wiring to make entire system functional complete including all accessories and fittings/fixtures all as specified and directed. |
| 465 | Emergency Lighting & Exit SignSupply, Installation, Testing & Commissioning of Addressable Combined Fire Alarm and Emergency LightingControl Panel features 1 loop expandable up to 2 loop with loop card, compliant to BS 5266, supports two lighting lines up to 127 points per line. The panel shall have event memory of 500 events, a line current of 2.5 amp with suitable capcity CT installed inside the enclosure, networkable up to 12 panels, complete including all accessories and fittings/fixtures all as specified and directed. Make : Hochiki/Neptolux/Tamlite |
| 466 | ELS (Emergency Lighting System) Panel CT 230 V with an output of 35V AC, placed between mains and EL2 Control panel, approved as per BS EN 60598-2-2 by LIA laboratories Ltd, complete including all accessories and fittings/fixtures all as specified and directed. Make : Hochiki/Neptolux/Tamlite |
| 467 | Key pad with an LCD to control, read and configure the Main Emegency Lighting System (ELS) Control Panel complete including all accessories and fittings/fixtures all as specified and directed. Make : Hochiki/Neptolux/Tamlite |
| 468 | Addressable Exit Signage visible from a distance of 20 m containing an integral long-life NiMH battery which complies with BS5266 in regards to providing 3 hours of illumination. The signage shall have dual fixing feature to mount either on ceiling or a wall. The device shall complies to BS5266 and contain range of directional lenses with ISO7010 legends, (Approved as per BS EN 60598-2-2), complete including all accessories and fittings/fixtures all as specified and directed. Make : Hochiki/Neptolux/Tamlite |
| 469 | Addressable Corridoor Area LED Down light visible from minimumdistance 40 m. Luminaries shall contain long-life NiMH batteries and latest LED technology conforming to IP 55 and operation temperature -25° to +40°C. Light shall cast a rectangular pattern of light to illuminate corridors and escape route (Approved as per BS EN 60598-2-2 with BS EN 60598-1:2008) with integral battery capacity of 3 hr and bicoloured LED status indicator complete including all accessories and fittings/fixtures all as specified and directed.Make : Hochiki/Neptolux/Tamlite |
| 470 | Addressable Open Area LED Down light vissible from minimumdistance 40 mtr. Luminaries shall contain long-life NiMH batteries and latest LED technology conforming to IP 55 and operation temperature -25° to +40°C. Light light shall cast circular pattern of light to illuminate open areas.(Approved as per BS EN 60598-2-2 with BS EN 60598-1:2008)with integral battery capacity of 3 hr and bicoloured LED status indicator complete including all accessories and fittings/fixtures all as specified and directed.Make : Hochiki/Neptolux/Tamlite |
| 471 | Screened and twisted single pair copper conductor 1.5 Sq mm 2 core annealed, tinned, multistrand, PVC Insulated, fire survival wire complete all as specified anddirected. |
| 472 | 1.6 mm thick MS Conduit 20 mm dia including includingjunction box, bends, elbow, sockets, Tee etc. laying on slab, complete including all accessories and fittings/fixtures all as specified and directed. |
| 473 | Heat Detection TubeVdS Approved signal processor unit having LED & LC display with 16 Relay, able to support 350 m sensor cable length with 1 to 100maximumsensor. The alarm triggering via differential and maximum temperature evaluation, High temperature resolution of 0.1 °C with a repeatability of ±0.1 K along the entire sensor cable length. Panel shall be free from false alarms, caused by natural ambient temperature fluctuations, due to intelligent evaluation algorithms. Highly durable via utilisation of maintenance-free components in a modular configuration, RoHS compliant. Individual password-protected access levels for operators, maintenance and service personnel, as well as for commissioning Operating temperature: -25°C to +70°C, complete including all accessories and fittings/fixtures all as specified and directed. |
| 474 | VdS approved, Heat Sensing Cable, sensors mounted in an encapsulation at every 4 m interval, complete encapsulation to protect sensors from environmental influences, Pinpoint sensor location via individual addresses, constant sensor monitoring via control and evaluation unit, branching of cable routes via connection boxes. Cable shall detect freely adjustable absolute alarm thershold & freely adjustable differential alarm thershold i.e. fixed temperature as well as rate of rise of temperature, measuring range -40°C to +120°C, complete including all accessories and fittings/fixtures all as specified and directed. |
| 475 | Connection cable2-wire, 0.8 mm core diameter, with functional integrity E30 - E90 according to DIN 4102-12; outer sheath in HM2 compound, red, loop resistance: max. 77 Ohm, connecting cable between sensor cable & controller complete including all accessories and fittings/fixtures all as specified and directed. |
| 476 | Clamp one-piece, self-locking polyamide cable clamp for indoor and outdoor use, Tool less locking mechanism, Halogen-free according to IEC 754-2, UV resistance according to ISO 4892-2, Temperature range -30 to +110°C, complete including all accessories and fittings/fixtures all as specified and directed. |
| 477 | Connection module in the housing for a sensor cable, up to four external sensors and corresponding connection lines to the control and evaluation unit; Housing material: glass-fibre reinforced polycarbonate, halogen-free, UV and weather-resistant, free of heavy metals, Protection class: IP 66 according to EN, complete including all accessories and fittings/fixtures all as specified and directed. |
| 478 | ExternalElectricitySupplyLow Tension (LT)XLPEinsulated, armoured, heavy duty, earthed, electric power cable, cross sectional area 400 Sqmm 3.5 core aluminum conductor 1100 V grade under ground cable including both side connection with cable lugs etc, laid in trenches, alongpolesorpassing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note(s): (i) Excavation & earth work, sand cushioning/PCC Cover/GI Pipe/MS Clamps/MS supports/cable tray shall be measured and paid separately.(ii) Pre-dispatch inspection of the cable to verify the correctness of specification & genuineness of cable will be carried out by the rep of Accepting Officer in the factory premises of the manufacturer. |
| 479 | All as per Item No 376 here-in-before but cable size 300 Sqmm, 3.5 core. |
| 480 | All as per Item No 376 here-in-before but cable size 240 Sqmm, 3.5 core. |
| 481 | All as per Item No 376 here-in-before but cable size 185 Sqmm, 3.5 core. |
| 482 | All as per Item No 376 here-in-before but cable size 120 Sqmm, 3.5 core. |
| 483 | All as per Item No 376 here-in-before but cable size 70 Sqmm, 3.5 core. |
| 484 | All as per Item No 376 here-in-before but cable size 95 Sqmm, 3.5 core. |
| 485 | All as per Item No 376 here-in-before but cable size 50 Sqmm, 3.5 core. |
| 486 | All as per Item No 376 here-in-before but cable size 35 Sqmm, 3.5 core. |
| 487 | All as per serial Item No. 376here-in-before but cross sectional area 10Sqmm 4 core copper. |
| 488 | All as per serial Item No.376here-in-before but cross sectional area 6Sqmm 4 core copper. |
| 489 | All as per serial Item No. 376 here-in-before but cross sectional area 1.5Sqmm 4 core copper. |
| 490 | All as per serial Item No. 376 here-in-before but cross sectional area 2.5Sqmm 3 core copper. |
| 491 | All as per serial Item No. 376 here-in-before but cross sectional area 1.5Sqmm 3 core copper. |
| 492 | High Tension (HT), 11000V, (earthed) grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 120 Sqmm, 3 core under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and directed.Note(s): (i) Excavation & earth work, sand cushioning/PCC Cover/GI Pipe for protection of cable shall be measured and paid separately.(ii) Pre-dispatch inspection of the cable to verify the correctness of specification & genuineness of cable will be carried out by the rep of Accepting Officer in the factory premises of the manufacturer. (Location:- From sub station No-1 to Main power house) |
| 493 | All as per Item No 377 here-in-before but cable size95 Sqmm, 3core. |
| 494 | Double wall corrugated high density polyethylene pipes outer dia 150 mm, inner dia 132 mmhaving corrugation on the outer wall and plain surface on the inner wall confirming to IS- 14930 (Part I&II) for protection ofunderground cables with all fittings, laid in trenches /road/nallah or fixed along wall , poles or laid under floor etc all as specified and directed. |
| 495 | All as per Item No 378 here-in-before but outer dia 100 mm, inner dia79.5 mm. |
| 496 | All as per Item No 378 but here-in-before but outer dia 80 mm, inner dia 63.5 mm. |
| 497 | All as per Item No 378 but here-in-before but outer dia 50 mm, inner dia 39 mm. |
| 498 | Excavation in trenches in soft soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables and foundation of poles etc. and getting out, complete all as specified and directed. |
| 499 | Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed. |
| 500 | Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 501 | Sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 180mm) shall be considered for measurement and payment. |
| 502 | Factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dryin trenches over the cable for protection, length perpendicular to the direction of cable, adjacent to each other, complete all as specified and directed. |
| 503 | Factory made unreinforced precast concrete cable cover HV type-1, flat, of size 300x180x40mm, laid flat and dryin trenches over the cable for protection, length perpendicular to the direction of cable, adjacent to each other, complete all as specified and directed. |
| 504 | Supply and fix Cable route indicator, showing \"HT UG cables\" painted in brown colour and route of cable with arrow, made of CI in suitable elliptical shape and fixed with MS rod 12mm dia 70mm long ( all words embosed) and embedded in PCC block of size 30x30x30cement mortar in ground complete all as specified and directed. |
| 505 | Supply and laying / fixing , GI pipe light grade 150mm dia bore for cable protection fixed to pole/wall or laid under floor/road/pavement, complete all as specified and directed.Note(s) : (i) MS clamps, nuts, bolts etc where required shall be measured and paid separately.(ii) Boring of holes under road etc. shall be measured and paid separately. |
| 506 | All as per item No. 386 here-in-before but of size 100 mm dia bore. |
| 507 | All as per item No. 386 here-in-before but of size 80 mm dia bore. |
| 508 | All as per Item No 386 here-in-before but 40 mm bore for protection of earthing strip & for air termination rod. |
| 509 | All as per item No. 386 here-in-before but of size 32 mm dia bore. |
| 510 | Taking out/down existing cables of any size frompower house to switch rooms,various floors and other area at Comd Hosp complete all as specified and directed. |
| 511 | Taking down existing trunking busbar of capacity 800/630 Amp from switch rooms to various floors of Comd Hosp complete all as specified and directed. |
| 512 | Supplying, installation, testing and commissioning of 800 Amp, 50 KA capacity Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 V, 50Hz AC with metal clad enclosure as integral earth having IP-55 for indoor after fixing the adopter boxes and all accessories, made out of 1.6mm thick GI sheet steel duly painted with color shade RAL-7035 or equivalent, complete with 4 No. Copper busbars throughout the length having class-F Insulation(155°C) and Impulse withstand 12KV at nominal current rating and ambient temperature of 40°C, including flange end, spring hangers, end cover, end feed unit, tap off boxes with MCCB 250A, 36KA Adjustable thermal fixed magnatic - 06 No (01 No for each floor) and MCCB 800A, 50 KA Adjustable thermal fixed magnatic - 01 No main incomer with accessories as per latest IEC 61439 part 1 & 6 complete including all accessories and fittings/fixtures all as specified and directed. |
| 513 | Supplying, installation, testing and commissioning of 630 Amp, 50 KA capacity Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 V, 50Hz A.C, with metal clad enclosure as integral earth having IP-55 for indoor after fixing the adopter boxes and all accessories, made of 1.6mm thick GI sheet steel duly painted with color shade RAL-7035 or equivalent, complete with 4 No copper busbar throughout the length having class-F Insulation(155°C) and Impulse withstand 12KV at nominal current rating and ambient temperature of 40°C, including flange end, spring hangers, end cover, end feed unit, tap off boxes with MCCB 400A, 36KA, Adjustable thermal fixed magnatic x 01 No for ground floor and 250A, 36KA, Adjustable thermal fixed magnatic x 04 No for other floors and main MCCB 630A, 50 KA Adjustable thermal fixed magnatic-01 No with accessories as per latest IEC 61439 part 1 & 6 complete including all accessories and fittings/fixtures all as specified and directed. |
| 514 | Supplying, installation, testing and commissioning of 630 Amp, 50 KA capacity Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 V, 50Hz AC, with metal clad enclosure as integral earth having IP-55 for indoor after fixing the adopter boxes and all accessories, made out of 1.6mm thick GI sheet steel duly painted with color shade RAL-7035 or equivalent, complete with 4 No. aluminium busbars with Copper +Tin plating throughout the length having class-F Insulation (155° C) and Impulse withstand 12KV at nominal current rating and ambient temperature of 40°C, including flange end, spring hangers, end cover, end feed unit, tap off boxes with MCCB 400A, 36KA, adjustable thermal fixed magnatic x 02 No for 2nd and 3rd floor and 250A, 36KA, adjustable thermal fixed magnatic for others floor and Main MCCB 630A, 50 KA Adjustable thermal fixed magnatic-01 No with accessories as per latest IEC 61439 part 1 & 6 complete including all accessories and fittings/fixtures all as specified and directed. |
| 515 | Supplying, installation, testing and commissioning of 800 Amp, 50 KA capacity Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 V, 50Hz AC, with metal clad enclosure as integral earth having IP-55 for indoor after fixing the adopter boxes and all accessories, made out of 1.6mm thick GI sheet steel duly painted with color shade RAL-7035 or equivalent, complete with 4 No. copper busbar throughout the length having class-F Insulation (155°C) and Impulse withstand 12KV at nominal current rating and ambient temperature of 40°C, including flange end, spring hangers, end cover, end feed unit, tap off boxes with MCCB 400A, 36KA, adjustable thermal fixed magnatic x 02 No for 1st and 2nd floor and 250A, 36KA, Adjustable thermal fixed magnatic x 01 No for other floor and Main MCCB 800A, 50 KA Adjustable thermal fixed magnatic- 01 No with accessories as per latest IEC 61439 part 1 & 6 complete all as specified and directed by Engr-in-charge. |
| 516 | Supplying, installation, testing and commissioning of 630 Amp, 50 KA capacity Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 V, 50Hz AC, with metal clad enclosure as integral earth having IP-55 for indoor after fixing the adopter boxes and all accessories, made of 1.6mm thick GI sheet steel duly painted with color shade RAL-7035 or equivalent, complete with 4 No Copper busbar throughout the length having class-F Insulation (155°C) and Impulse withstand 12KV at nominal current rating and ambient temperature of 40°C, including flange end, spring hangers, end cover, end feed unit, tap off boxes with 320A, 36 KA Adjustable thermal fixed magnatic MCCBs for each floor and Main MCCB 630A, 50 KA Adjustable tharmal fixed magnatic- 01 No with accessories as per latest IEC 61439 part 1 & 6 complete including all accessories and fittings/fixtures all as specified and directed. Note for item no 389 to 393:- 1. Drawing for busbar shall be approved by GE before placement of order.2. Necessary work like electric connection from existing /new LT panel to be made by the contractor. |
| 517 | Supplying, installation, testing and commissioning ofAIR CIRCUIT BREAKER (ACB) 630 Amp, 4P, electrical draw out with breaking capacity of 50kA (Ics=Icu=Icw for 1sec), microprocessor-based fully configurable protection release with password protected adjustable over load, short circuit, earth fault protection with LCD display of current & Voltage Meter&100 trip historyalongwith LED type indication of pre trip alarm &percentage load bar graph of each phase on release. ACB should be withZSI, impulse withstand of 12kV,Neutral protection selectivity for 50% or 100% with 25 m sec Short circuit tripping time & having incoming & outgoing terminal adapter, including taking down the existing ACB complete including all accessories and fittings/fixtures all as specified and directed. |
| 518 | All as per item No. 394 here-in-before but 1000 Amp. |
| 519 | All as per item No. 394 here-in-before but 2000 Amp. |
| 520 | Taking down existing unserviceable Aluminium stip of lightning protection fixed on roof/ wall from various floor to test point including insulator, saddles, screws etc complete all as specified and directed. |
| 521 | Taking down existing unserviceable GI strip from test point to earth pit complete all as specified and directed. |
| 522 | Taking down existing unserviceable aluminium air terminal pointer complete all as specified and directed. |
| 523 | Taking down existing unserviceable test point terminal box complete all as specified and directed. |
| 524 | Supply andfix single pointed air termination aluminium rod 12mm dia, 300mm long, complete all as specified and directed. |
| 525 | Test point terminal block made of gun metal or phosphorous bronze 75x75x25mm drilled including screwed 04 No 8mm dia 25mm long hexagonal head brass screws including box of size 90x90x90mm made of 1.6mm CRCA sheet painted with two coats of synthetic enamel paint over a coat of red oxide primer and screwed to wall for protection of test point complete including covered with 3mm thick laminated sheet complete all as specified and directed. |
| 526 | Plain cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate, for coping/muff of Existing/New poles, plinth blocks of HT/LT poles, in front of out door panel boards, in foundation for holding GI pipe etc., including use & waste necessary form work & finishing the exposed surfaces fair & even without using extra cement, complete all as specified and directed. |
| 527 | Supplying, installation, testing and commissioning of Weather and vermin proof LT feeder pillar boxof suitable size (main feeder pillar) factory fabricated out door type totally enclosed outer cover made out of 3.15mm thick CRCA Sheet and inner compartments of 2.00 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 V 50 Hz system, with hinged pannel door (covers) on two sides with handle, bottom gland plate and locking arrangement consisting of sufficient No of circular cable entry holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with neccesaryinternal wiring with stranded copper conductor FRLSH wires of adequate size, duly powder coated internally & externally of approved colour with PCC foundation (1:2:4) and 600A aluminium bus bar for 3 phase & neutral mounted on epoxy insulator with suitable rated CTs, digital ammeter & Voltmeter, LED indicator lamp and danger plate including following accesories, complete including all accessories and fittings/fixtures all as specified and directed:- INCOMING(a) MCCB 4 pole, 415 V, 400 Amp, 36 KA, Adjutable thermal fixed magnetic - 01 No.OUTGOING(a) MCCB 4 pole , 415 V,160 Amp, 25 KA, Adjutable thermal fixed magnetic -02 No(b) MCCB 4 pole , 415 V, 100 Amp, 25 KA, Adjutable thermal fixed magnetic-02 No(c ) MCCB 4 pole, 415 V, 63 Amp, 16 KA, Adjutable thermal fixed magnetic-01 No |
| 528 | Supplying, installation, testing and commissioning of Weather and vermin proof LT feeder pillar boxof suitable size (main feeder pillar) factory fabricated out door type totally enclosed outer cover made out of 3.15mm thick CRCA Sheet and inner compartments of 2.00 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 V 50 Hz system, with hinged pannel door (covers) on two sides with handle, bottom gland plate and locking arrangement consisting of sufficient No of circular cable entry holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with neccesaryinternal wiring with stranded copper conductor FRLSH wires of adequate size, duly powder coated internally & externally of approved colour with PCC foundation (1:2:4) and 500A aluminium bus bar for 3 phase & neutral mounted on epoxy insulator with suitable rated CTs, digital ammeter & Voltmeter, LED indicator lamp and danger plate including following accesories, complete including all accessories and fittings/fixtures all as specified and directed:-INCOMING(a) MCCB 4 pole, 415 V, 320 Amp, 36 KA, Adjutable thermal fixed magnetic - 01 No.OUTGOING(a) MCCB 4 pole , 415 V,125 Amp, 25 KA, Adjutable thermal fixed magnetic -02 No(b) MCCB 4 pole , 415 V, 100 Amp, 25 KA,Adjutable thermal fixed magnetic -02 No Note for item no 402 & 403:-1. All the switch gears used in the panel will be of same make. 2. All MCCBs removed out from old existing LT Panels shall be deposited to MES Store and not a part of Schedule of Credit.3. Drawing for LT panel shall be approved by GE before placement of order, Two No of empty slolt will be provided in the panel and all necessary worklike electric connection for existing supply to be made by the contractor. |
| 529 | Two coats of synthetic enamelled paint (externally & door opening from inner side)with spray machine, including marking of feeder No/voltage etc. after preparation ofold painted steel surfaces of LT/HT panels & bus bar chambers, after taking shut down, complete all as specified & directed. |
| 530 | Taking out ofexisting LT Panels with all accessoriescomplete, including fixture and fittings such as switches, MCCBs, MCBsetc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.Note: (i) Following MCCBS shall be deposited in the MES store as directed by Engr-in-charge:- MCCB 400 amp -6 No, 300 Amp- 4 No, 250/200 Amp- 8 No, 150/120/100 Amp- 6 No and 63 Amps -8 No.(ii) Contractor shall be responsible to provide electric supply from nearest trunking busbar/ panels at switch room of various floor during taking down of LT cables and trunking busbar without any extra cost.(iii) Contractor shall visit the site/11 KV substaion before bid submission. |
| 531 | Supply, erecting and fixing in truly verticle position, steel tubular swaged pole, type Supply and fixing/erecting in true vertical position, steel tubular pole, swaged, type 410-SP-55 (11 metre long) complete with finial taper plug, bolts, nuts, scerws as specified, CI base plate including drilling holes and painting with two coats of aluminium paint externally, providing 30cement mortar wide alternate strips with white and black synthetic enamal paint upto 1.2m height from ground level and numbering the pole (with black and white paint), undergruound part of the pole shall be painted with black bituminous paint complete all as specified and directed.Note: Excavation & earthwork, PCC foundation shall be measured and paid for separately. |
| 532 | Supply, fixing, testing and commissioning of air break gang operated switch triple pole mechanically operated outdoor type with all fittings/accessories mounted on and incl 11 KV HT porecain insulator and steel channel frame, GI rod 25 mm dia medium grade of suitable length with operating mechanism suitable for operation from ground level with dropout fuse consisting of 12 No insulators ISI marked, horizontal or vertically operated including locking arrangement for operating handle with and including 7 lever lock with three Keys complete suitable for current rating of upto 200 Amp HT 11 KV complete including all accessories and fittings/fixtures all as specified and directed. |
| 533 | HT lightningarrestors, non resistance type, for out door use complete with all fittings and fixing arrangement such as brackets, clamp, nuts, washers and connecting to earth wire 4 mm dia GI wire, transmission class, discharge capacity 65 KA, suitable for 11000 V, 3-phase, complete including all accessories and fittings/fixtures all as specified and directed. |
| 534 | Cable joint kit for 11 KV HT (earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed. |
| 535 | 400 KVA outdoor transformer floor mounted11KV on HT side and 433 V on LT side at no load, step down, 3 phase, 50 c/s, AC, copper wound, oil immersed, air natural oil natural with external cooling tubes core type. Transformer with off load tapping on HT side to vary secondary Voltage +/- 7.5% in steps of +/-2.5 %. The transformer shall conform with the requirement of IS-2026 and oil shall conform to IS-335,1983. The temperature rise shall not exceed 55 degeree centigrade in winding and 45 degree centigrade in oil when measured by the resistance method after continous full load run and on ambient temperature of 48 degree centigrade, copper wound, (losses shall be as per IS-1180 Part I 2022 level 2),all as specified. The transformer shall be complete with the following:-(a) HV Bushing of suitable size.(b) LV glands and cable box of suitable size.(c) Oil conservator.(d) Dehydrating breather with first fill of dehydrating agent.(e) Thermometer pocket with thermometer dial of suitable size.(f) Two Earthing terminals on tank and take cover with lugs to suit 32x6 mm GI strip.(g) Rating Plate.(h) Terminal marking plate.(i) Oil level gauge.(j) Oil drain and filter valve. (k) Lifting lugs. (l) Four plain rollers.(m) Oil filter plug with connection complete.(n) Extra bushing for neutral outside the cable box for providing independent earthing.(o) Oil filling hole with cap.(p) First filling of oil.(q) Cable box on LV side with cable gland. Note: (i) Drg of transformer shall be approved from GE before execution.(ii)Pre-commissioning of transformer shall be carried out by rep of accepting officer.(iii) Necessary T&P required for testing shall be provided by contrctor. |
| 536 | Platform for transformer of size 3000 x 2500 x 1200 mm with brick masonry construction in cement mortar 1:4, 150 mm thick, PCC (1:4:8) type D-2 150 mm thick in foundation 30cm depth, PCC (1:2:4) type B-1, 40 mm thick in floor over sub base PCC (1:4:8) type D-2, 75 mm thick, brick masonry step on one side, 15mm thick plastering to brick masonry in cement mortar 1:4 finished even & fair and three coats of white wash after preparation of surface including excavation and earth work in any type of soil complete all as specified and directed. |
| 537 | Supplying, installation, testing and commissioning of Weather and vermin proof LT feeder pillar boxof suitable size (main feeder pillar) factory fabricated, out door type, totally enclosed, outer cover made out of 3.15mm thick CRCA Sheet and inner compartments of 2.00 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm with PCC foundation (1:2:4), suitable for operation on 3 phase 4 wire, 440 V 50 Hz system, with hinged pannel door (covers) on two sides with handle, bottom gland plate and locking arrangement consisting of sufficient No of circular cable entry holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with neccesaryinternal wiring with stranded copper conductor FRLSH wires of adequate size, duly powder coated internally & externally of approved colourand 1200A aluminium bus bar for 3 phase & neutral mounted on epoxy insulator with suitable rated CTs, Ammeter, Voltmeter, indicator lamp and danger plate including following accesories:- INCOMING:-(Main panel) (i) ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 800 Amp 50 KA having LCD display with min 50 fault records = 02 No OUTGOING:- (ii) MCCB 320 Amp, 4 pole 36 KA, adjustable thermal fixed magnetic = 3 No(2W+1S) (ii) MCCB 160 Amp, 4 pole 36 KA, adjustable thermal fixed magnetic =1 No Note: (i) Drawing for LT panel shall be approved by GE before placement of order and all necessary worklike electric connection from existing panel to new panel to be made by the contractor.(ii) All the switchgears used in the panel will be of same make. |
| 538 | Supplying, installation, testing and commissioning of Eco friendly silent diesel engine driven generating set of 400 KVA at 0.8 power factor, 415 V AC, 3 phase, 50 Hz, 4 wire, directly coupled alternator and engine, water cooled, common base platform with floor mounted fuel tank and auto main faliure system including all civil work such as excavation, PCC foundation, anti-vibration pads/dampers including standard auto control panel as per manufacturer\"s instructions and other accessories comprising following:- (A) Engine: Eco friendly or emmission and noise standard (CPCB norms IV+ or latest and as specified), 4 stroke diesel engine as per manufacturer\"s design conforming to BS standard BHP, 1500 RPM, turbocharged after cooling complete under NTP condition with a provision for 10% over load for one hour on 12 hours running with the following:(i) Fly wheel with starter ring for generating set(ii) Dry type air filter(iii) Exhaust air manifold(iv) Exhaust silencer(v) Expasion bellow(B)Alternator: Brushless type suitable for direct coupling to engine, self excited, self regulated with fast response thyristor type electronic automatic Voltage regulator for output Voltage within desired limits (+1%), dynamically balanced 400/415 V AC, 3 phase, 50 Hz , 4 wire, 0.8 power factor lagging 400 KVA, 1500 RPM, star connected (4 Wire) screen protected drip proof enclosures, air cooled with radial fan mounted on rotor with insulation all as per BS-2613 IS 4722 with following accessories:- |
| 539 | (i) One MS frame suitable for mounting of engine and alternator.(ii) One fuel tank of suitable capacity 8 to 12 hr continuous running complete with fuel gauge, inlet/outlet connections, drain plug etc to be mounted on suitable angle iron frame or grouted in wall as per manufactururer\"s instructions.(iii) Two No 12 V DC battery of suitable AH, SMF type with copper leads and terminal lugs of suitable size.(iv) One set of AVM pads fitted on base frame.(v) One hand rotary type fuel pump connected with heavy duty pipe upto the tank.(vi) Adequate ventilation to meet air requirment for combustion and heat removal with a provision of blower.(vii) Emergency stop push button outside the container.(viii) Provn of light inside the conopy providing a FTL fillting.(C) Foundation: PCC foundation shall be as per manufacturer\"s design/instructions. (D) Accoustic enclosure: Accoustic enclosure suitable for DG shall be as under:-(i) Fabricated out of CRCA sheet of suitable thickness as per manufacturer\"s design conforming to relevant IS and satutory guidelines on the subject. Polyster based powder coated internally and externally with lockable type door handle, all nuts, bolts and hardware are zinc coated.(ii) Sheet metal components shall be hot dip seven tanks pretreated.(iii) The doors are gasketed with EPDM gaskets. |
| 540 | (iv) Sound proofing with high quality rock wool/ mineral wool conforming to IS 8183 of 50 mm thickness and of density 96 kg/m³ covered with fiber glass cloth and peforated powder coated sheet. Specially designed attenuators (sound controller) at air entry and exit of the container. Noise level shall not excced 75 dBA at 1 m distance as per CPCB norms.(v) Adequate ventilation to meet air requirment for combustion and heat removal.Note: (i) Pre commissioning test shall be carried out by the rep of AO. (ii) POL and testing equipments shall be provided by contractor. |
| 541 | Sch of Credit |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail