| 1 | M&L for Repair to pot holes any depth, not exc 1 sqm each including sweeping free from dust and mud or water, scoring sunken surfaces in roads, paths, etc cutting around edges to at least 25mm in depth, and making good by applying tack coat @ 5 Kgs per 10 Sqm and laying premixed bituminious macadam well rammed and sealed with paving bitumen 60/70 or VG-30 grade@ 9.8 Kgs per 10 Sqm, blinded with 0.09 Cum of stone chipping of size 6.3mm and again well rolled with 8 to 10 tonne power roller (Iincluding supply of pre-mixed macadam, binder and chipping) depth of pot holes exc 30mm complete all as specified and directed by Engineer-in-Charge. |
| 2 | M&L for Preparing existing black top surface or bituminous macadam surfaces by brushing with brushes for removing caked mud etc sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all loose dirt etc on back top/concrete surfaces than applying evenly priming tack coat with paving bitumen 60/70 or VG-30 penetration over the prepared surface by mechanical sprayer @ 5 Kgs/10 Sqm of surface area complete all as specified and directed by the Engineer -in-Charge. |
| 3 | M&L for applying bituminous premixed semi dense asphaltic concrete 40mm thick (consolidated thickness) with 5.5% binder content of paving bitumen 60/70 or VG-30 grade by weight of total mix including cement filler, on surfaces rolled & compacted with using 8 to 10 tonne capacity power roller to achieve the required compactness, camber and gradient mixed in hot mix plant using design mix and laid by mechanical paver finisher. Complete all as specified and directed by the Engineer-in-charge. |
| 4 | M&L for preparation of existing bituminous surfaces, removing, dust, dirt grease and other foreign matters etc to receive the marking and M&L for thermo plastic (Reflective) line marking having 1.0 mm thickness (average) of uniform surface finish conforming to BS3262 (Part 1) 1989 read in conjunction with the MOSTspecification 803 clause 4.2.2 on bituminous surfaces in white/yelow clour and super imposed with glass beads confirming to BS 6088 read in conjuction with and MOST specification 803 clause 4.3.3 complete all as specified and directed. Note - MOST specification 803 shall be followed strictly for execution of work&suitable machine shall beused for the marking as approved by the GE. Shape & size/ patterns ofmarking shall be as approved by the GE. |
| 5 | S&F in repair cat eyes/road studs for roadways sign permanent surface mounted type having tough poly carbonate micro replicated corner cube reflector lenses with a protective abrssion resistant ceramor coating having body of weather proof and impect resistant thermoplasit complete as per manufacturer,s instruction and as directed. |
| 6 | S&F in repair solar cat eyes/road studs size (mm) 125L x 125B x 25H including stem height 53mm approx housing dia cast aluminium (grade LM-6) fully water proof and weather proof and weatherproof coating visible distance upto 400mtr LED-6 super bright amber led (3 Nos each side) yellow charged, flush frequency 1.2 Hz-1.8Hz including solar panel 3.5V/110MA & battery one PC sub ‘C’ type Ni-Cd rechargeable battery 1.2V/2.5AH temp range 20C to 70C fixed on road for roadway signcomplete as per manufacturer’s instruction and directed . |
| 7 | S&F in repair plastic speed bumbs (Speed breakers) not less 400 mm wide blocks & yellow colours fixed with necessary spikes/screws to the road surface etc. Complete all as specified & directed . |
| 8 | S&F in repair ABS Body, 100 cm outdoor convex mirror good quality as approved by GE fixed in road/ground portion complete including hanging/fixing arrangement with adequate mounting arrangement at suitable height, having unbreakable Polycarbonate Convex Lens with hoods as the traffic safety mirror for eliminating blind spots & increase visibility at a broader angle, including excavation for post holes, PCC Type C-2 1:3:6 (using 40 mm graded stone aggregate) in post hole & removal of surplus excavated material to a distance not exceeding 50 metre & depositing where directed at a level not exceeding 1.5 metre above the starting point. Complete all as specified & directed. |
| 9 | S & F Plastic Kerb Stone (size 300x150x120mm) with Led lightting,high intensity,UV Protected, water proof with IP567-65 and tested as per IS 16104 standard more energy-efficient, more illuminating,including all necessary point wiring and electrical connection fixed on steel/concrete surface etc all as specified and directed. |
| 10 | S&F in repair high intensity prismatic retro - reflective (3m/Avery) sheet of colour as directed, self adhesive, fixed on steel/concrete surface etc all as specified and directed. |
| 11 | S&F in repair Alcolite Spring Post/Flexible delinator, strong flexible UV protected PU & PVC with high intensity reflective light material crystal lattice, 75 mm dia, 750 mm height including all necessary fittings. Complete all as specified & directed by Engr - in - Charge. |
| 12 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified. |
| 13 | S & F of rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete, drilled for fixing of steel sheeting or other covering doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting and also fastening confirming to Fe – 410 – W(Gde E - 250) quality \"B\" complete all as specified and directed. |
| 14 | M&L for two coats synthetic enamelled paint to new steel surfaces after preparation over a coat of red oxide primer area over exc 10cm in width or girth etc complete all as specified and directed. |
| 15 | M & L Premixed sand seal coat with 0.06 cu.m. of sand mixed with 6.8 kg of Paving bitumen, applied and rolled to a uniform smooth surface complete all as specified and as directed by Engr-in-Charge. |
| 16 | M&L for premixed bituminous macadam laid, rolled and compacted to required gradient and camber n.exc 75mm thickness (consolidated thickness) with 4% binder content of VG -30 by weight of total mix, mixed in hot mix plant and laid by mechnical paver finished complete. |
| 17 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves(thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 18 | Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for. Complete all as specified & directed. |
| 19 | M&L for cement concrete B-1 (1:2:4 ) (20 mm graded stone aggregate) as in path/ hardstanding surface even and fair complete all as specified and directed |
| 20 | M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface all as specified and directed. |
| 21 | S&F machine pressed precast concrete interlocking paver block any shape & size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement & pigment complete all as specified & directed. |
| 22 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 23 | S&F in repairs 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed |
| 24 | S&F in repairs 110mm bore PVC (SWR) bends any radius complete all as specified and as directed |
| 25 | M&L for Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m depth insoft /loose soil etc complete all as specified and directed. |
| 26 | M&L for Returning, filing in, including spreading, levelling, watering and well rammingin layers not exceeding 25 cm in any type of soil etc complete all as specified and directed |
| 27 | M&L for Removing excavated material (Soil) exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed. |
| 28 | M & L for Moorum / Red bajri filling in floors or pavings, laid in layer not exc. 15 cm tkick, spread, levelled, and blinded with earth including well ramming and watering as required complete all as specified and directed. |
| 29 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off premises complete all as specified and directed |
| 30 | M&L 16 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 31 | M&L PCC 1:2:4 Type B1 with metallic hardener (20mmgraded agg) as in copings,kerbs and like incl weathering slightly rounded or chamfered angles without extra cement for smooth finish as directed by engineer incharge . |
| 32 | M&L applying two coats of acrylic exterior weather proof emulsion paint over a coat of exterior primer on newly plastered wall surfaces,dusting & finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc complete all as specified and directed. |