Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5m, as directed by Engr-in-charge |
| 2 | Ditto all as per item sl no 1 here-in-before but exc 1.5 m and not exc 3.0m deep. |
| 3 | Taking down chowkats or frameswith shutters (without taking off shutter from the frames) exceeding1.5 sqm & not exceeding4 sqm each complete all as specified and directed |
| 4 | M&L for pressed steel frames of size125mm x 60mmfor doors with one or more rebatesincludingnecessary fixing lugs, keys , hinges lock, lock strike plate etc.made out of 1.25mm thick MS sheet including one shop coat of red oxide zinc chrome primer etc complete all as specified and directed . |
| 5 | M&L 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides with both face is covered with deco rative face veneer with lipping/frame to match complete all as specified and directed. |
| 6 | Taking downchowkats or frames with shutters (without taking off shutter from the frames) n.exc 1.50 Sqm each all as specified and as directed. |
| 7 | M&L for Solid PVC door/cup board frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, suppling and fixing in opening complete all as specified and directed. |
| 8 | M&L for Factory made solid panel PVC door/cup board shutter 30mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails.M.S frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement or stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail.Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, suippling and fixing in the frame at site as per specification in SSR Part-I. complete all as specified and directed. |
| 9 | M&L for Pressed steel frame for door with one or more rebates including necessary lugs, fixing lugs hinges, lock strike plate etc. of size 105mm x 60 mm and made of 1.25mm thick MS sheet, complete all as specified and directed including necessary welding complete and including medium weight 03 Nos of MS butt hinges of size 75mm / 100mm / 125mm and 01 No 50mm Size of medium weight MS butt hinge complete all as specified and directed. |
| 10 | M&L for Steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast with locking arrangements, complete all as specified and directed. |
| 11 | S&F Galvanized mild steel wire cloth 0.45 nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tank or galvanized wire staple complete all as specified and as directed. |
| 12 | M&L for 3mm thick figured glass, pin head type and glazing with oil putty or wooden beads in square n.exc 0.5 sqm each complete all as specified and directed. |
| 13 | M&L for Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel springs, fixed in floor with over all length of cover plate 150mm complete all as specified and directed. |
| 14 | M&L PCC (1:3:6) type C-2 (20 mm graded aggregate) filling back of chowkats complete all as specified and directed. |
| 15 | S&F Butt Hinges medium weight cold rolled mild steel of size 100 mm completeall as specified and directed |
| 16 | S&F 150 mm size mild aluminium handles cast type anodised completeall as specifiedand directed |
| 17 | S&F 150mm Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 18 | M&L for RCC M-25 design mix as in foundation, including raft, footing, fdn beams, plinth beams bases for columns complete all as specified and directed. |
| 19 | M&L for RCC (Design mix) M-25 as in columns , pillars, piers, posts and struts etc complete all as specified and directed. |
| 20 | M&L for M&L for RCC (Design mix) M-25 as in beams, cantilevers, bressummers, lintel over 1.5 m span complete all as specified and directed. |
| 21 | M&L for RCC (Design mix) M-25 as in slabs supported on walls beams and columns in floors, roofs, landings, balcony, canopies, deck slabs and in salves and like complete all as specified and directed. |
| 22 | M&L for RCC (Design mix) M-25 as in walls, basement wall of any thickness above top of footings incl attached pilasters & buttresses complete all as specified and directed. |
| 23 | M&L for RCC (Design mix) M-25 as fins, facias, louvers, parapet and railing exc 60 cm ht, newals, balustrade & the like complete all as specified and directed. |
| 24 | M&L for RCC (Design mix) M-25 as in stairways,incl steps, string pieces complete but excluding railing complete all as specified and directed. |
| 25 | M&L for Form work to sides of concrete fdn footing base of columns and raft beams sides and soffits (if any) of plinth beams complete all as specified and directed. |
| 26 | M&L for Form work to sides of pillars, posts, struts, pier, columns square, rectangular or polygonal fair finished surface of concrete complete all as specified and directed. |
| 27 | M&L for Form work to sides and soffitsof floor or roof beams beam , lintels, cantilevers, shelves etc with fair finished complete all as specified and directed. |
| 28 | M&L for Form work to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar works not exc 20 cm wide and sides of PCC/RCC bands exc 10 cm but n.exc 20 cm wide with fair finished complete all as specified and directed. |
| 29 | M&L for Form work to faces of walls, retaining walls, abutments, parapets & staircase railing and similar work with fair finished. |
| 30 | M&L for Form work to staircase with slopping or stepped soffits incl risers & strings (exc landing) with fair finished complete all as specified and directed. |
| 31 | M & L for form work to edges of concrete flats, treads breaks in floors , window cills , concrete railling, opening in concrete walls, floors and roofsRCC/PCC bandsfloors roofs n exc 20 cm wide and sides of RCC/PCC bands in walls , horizontal or slooping and similar work exc 10 cm and not exc 20 cm wide surface finished roughcomplete all as specified and directed. |
| 32 | M & L for TMT bars 10 mm dia & over cut to length bent to shape required including cranking bending spirally for hoping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or seuring with chip with deep quality confirming to FE 500/FE 500D complete all as specified and directed. |
| 33 | Ditto all as per item sl no 32 here-in-before but 6 to 8 mm dia complete all as specified and directed. |
| 34 | M & L for TMT bars5mm dia and over upto and including 10mm dia as in stirrups and spacerscomplete all as specified and directed. |
| 35 | M & L for 75 mm thick Cement concrete type B2, 1:2:4 (using 40 mm graded granite stone aggregate) in sub base of flooring/ hard standing finishing the surface even and smooth complete all as specified and directed. |
| 36 | M&L for sunken treatment with glass fiber reinforced modified cementitious coating system before the final coat of Latex Shield 2K (or equivalent) complete all as following :-Base Coat : Berger HS Latex plus (or equivalent)consumption base coat : 0.3 kg/m2Reinforcement : Glass fiberSecond and Third coat : Latex sheild 2K (or equivalent)Consumption top coat : 3 kg/m2System reqquirements : density : 2.00 kg/ltr;Compressive strength: 0.5N/mm2Wall penetration through the RCC slab must be sealed using Berger HS Repair (or equivalent).Intersection of base slab with wall must be provided with a 50 mm fillet using Berger HS Latex plus (or equivalent) modified mortar with a bonding coat of Berger HS Latexplus (or equivalent) modified cement slurry upto sft.All depressions, unevenness, surface honeycombng shal be repaired using Berger HS Latex plus (or equivalent) modifiled polymer mortar with a bonding coat of Berger HS latex plus (or equivalent) modified cement slurry.Including cleaning of RCC surface to remove dust, loose paricles, etc with compressed air or any other suitable technique depending on site conditions, grinding aby sharp edges, etc.Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix \"AB\" on page no. 108 of tender documents as per Sch \"A\" Note No 19 Page No 17). |
| 37 | M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 with water proofing compound tobe finished even and smooth without usingextra cement completeall as specified and as directed (WPC to be measured and paid separately) |
| 38 | Supply onlyIntegral water proofing compound liquid M & L for completeall as specified and as directed |
| 39 | S&F 20mm dia High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in as spout pipes to pour out rsidual water out from the treated area completeall as specified and as directed |
| 40 | M&L for hard core, of broken bricks broken to gauge n exc 63mm for laying sub base of thickness 150mm complete all as specified and directed. |
| 41 | M&L Cementconcrete type D-2 1:4:8 (40mm graded crushed stone aggregate) in foundations, filling and mass concrete in sub base complete all as specified and directed. |
| 42 | M&L for 25mm thick PCC (1:2:4) type B1 with 20mm graded aggregate for laying floor tiles complete all as specified and directed. |
| 43 | M&L for non skid coloured Ceramic tiles 8 to 10 mm thick in light shade (square/ rectangular) polished, area of each tiles exc 0.11 sqm but not exceeding 0.18 sqm, in floors/Skirting etc. set, jointed and pointed with Berger HS tile adhesive anti slip white @1.2kg/sqm thickness upto 8 to 10mm (or equivalent) and epoxy material for sealing of tile joints with Berger HS Epoxy tile grout(or equivalent) to the floor of toilets and bathroom complete all as specified and directed. |
| 44 | Demolition of cement concrete in and paving (un reinforced)exc. 15 cm. thickness, below or above ground level, including removal of waste from defence land and dumping at a place as specified by civil authorities complete all as specified and directed. |
| 45 | S&F Vitreous China squatting pan \"Orissa\" pattern size 580 x 440 mm white, with integral foot rests with connection to drain and to flushing pipe antisyphonage pipe,brackets for flushing cistern ,PVC (SRW) \"P\" trap including provision of cement concrete bedding etc complete all as specified and dirtected by Engr-in-Charge . |
| 46 | S & F Vitreous China wash down pedestal pattern EWC, white and including with PVC (SWR)\" S\" Trap withconnection to drain and to flushing pipe antisyphonage pipe, including sheet cover and making good to floor complete all as specified and directed. |
| 47 | S&F Vitreous China wash basin, white, flat back, size 550 x 400 mm including , chain and plug but including brackets or erecting stand including&(32 mm-45 gms/40mm-60 gms ) waste couplingof PTMTcomplete all as specified and dirtected by Engr-in-Charge . |
| 48 | S&F 10 Ltrs capacity PVC valveless symphonic action type flushing cistern white low level with inlet, ball valve float handle including bracket ,32mm bore PVC flush pipe complete all as specified and directed |
| 49 | S& FPTMT towel rail60 Cm long fixed and including chromium plated brass screws and wooden / plastic cleats (minimum weight 190gms)to wall as directed |
| 50 | S&F PVC 32mm dia waste pipe with CP coupling, all as specified & directed. |
| 51 | Taking up or down 15mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specified and as directed. |
| 52 | Taking up or down 20mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specified and as directed. |
| 53 | S&F steel water tubing galvanised 15 mm bore medium grade fixed to walls, under floors and on ceiling surfaces or in chases including all fittings complete all as specified and directed. |
| 54 | S&F steel water tubing galvanised 20 mm bore medium grade fixed to walls, under floors and on ceiling surfaces or in chases including all fittings complete all as specified and directed. |
| 55 | S&F 15 mm angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed. ( minimum weight 90 gms) complete all as specified & directed. |
| 56 | S&F Stainless steel grating of 125mm size (square/round), male/female pattern with or without hole, fixed in nahani/floor traps with white/coloured cement, fixed in repairs, complete all as specified & directed. |
| 57 | S & F liquid soap container of PTMT fixed and including chromium plated brass screws and wooden / plastic cleats (minimum weight 105gms)to wall as directed |
| 58 | S&F in repair Bib taps, chromium platedcast copper alloy, withcapstan head, screwed down for iron pipe or for brass ferrule and fixed for bore of pipe 15 mm, fixed in repairs,all as specified and as directed. |
| 59 | S & Fin repair 20 mm bore Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed completeall as specified and directed. |
| 60 | S&F PVC (SWR)floor trap , plain with CP grating including jointing with solvent cement of 75mm outlet dia all as specified |
| 61 | S&F Fancy type, chromium plated angle valve 15 mm of cast copper alloy with crutch or butter fly handle, screwed down for iron pipe ,fixed in repairscomplete all as specified and directed. |
| 62 | S&F Pillar taps 15 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or with out lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts screwed for iron pipe fixed in repairscomplete all as spd & directed. |
| 63 | Dismantling water tanks of any description1000 Ltrs capacity complete all as specified and directed. |
| 64 | S&F Rotational moulded polyethlene water storage tanks , triple layered, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of Capacity 1000 litres including over flow , drain out pipe and all accessories completeall as specified. |
| 65 | S&F Ball brass valve, high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed to pipe20 mm bore fixed in repairsall as specified and directed. |
| 66 | Taking down cement plasteron bricksor stone wall / ceiling decayed surfaces of concrete, roof projections or chajjas etc upto triple storey including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 67 | M&L Rendering 10 mm thick in cement plaster 1:6 on fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 68 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 (with WPC) and finished even and smooth without using extra cement. WPC measured and paid separately |
| 69 | M&L for rendering 5 mm thick onconcrete surfaces of ceilingsin cm 1:3finished even and smooth withoutusing extra cementcomplete all as specified and directed |
| 70 | M&L for Rendering 5 mm thick onconcrete surface as in columns, RCC walls, fins etc in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed |
| 71 | M&L for 10 mm thick plastering/rendering on brick work on concrete surfaces in cement mortar (1:3) mixed with liquid water proofing compound as per manufaturer\"s instructions finishing surfaces even and smooth without using extra cement complete all as specified and directed. (liquid water proofing compound shall be measured and paid sepretaely). |
| 72 | Supply only liquid water proofing compound/admixture, ISI marked complete all as specified and directed |
| 73 | M&L for preparation of new plaster surfaces of ceiling and applying three coats of white wash on ceiling,all as specified and directed. |
| 74 | Preparation of new plaster surfaces of walls and applying two coats of oilemulsion distemper over a coat of chalk whiting on walls all as specified and directed. |
| 75 | Meterial and labour for preparation of newly plasstered wall surface and applying two coat of premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay echnology, Excellent Dirt Pick up resistance of Berger Paints Ltd or equivalent of other approved make with low VOC less than 50 gram/ litre as per the LEEDS specification, Anti Algal properties in Two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instruction applied over one coat 1\"1 ratio as per manufacture\"s instruction and all coats incl primer to be applied with fully automatic airlesspray machine of paint application with a flow speed of inium 1 ltr per minute having a pressure of 300 PSI. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and directed Make : Berger Paints Weathercoat Long Life Flexo/ Nerolac Paints excel Total/ Asian Paint Apex Ultima/ JK Maximo Ultra. Notes for smart periodicals (a) Work shall be done as per MoU between tenderer and manufacturer of paints and their authorized applicator complete all as specified and directed (b) the contractor shall upload MoU between tenderer and manufacturer of paints and their authorized applicator before quoting the bids and submit the same alongwith tender & other Documents as mentioned in NIT (c) Cost of scaffolding at any height shal be included in thequoted rate. (d) Preparation of plastered or unplastered surface of removal of existing treatment by scrappigng of walls, chajjas, ceiling, fins, fascias, parapets etc shall be done by using mechanial sander with internal dust extraction system for clean environment certified by the manufacturer. After the prepartaion of surface written approval shall be obtained from GE before applying primer and further tratment/ coat. Bldg wise stage passing register shall be maintained. (e) Finishes ie cement based paint, acrylic water based exterior grade primer, premium acrylic smooth exterior emulsion etc to walls, ceiing, chajjas, fins, fascias, parapets etc shall be applied using airles spray technology and capable of operating single spray gun with a suitable hose length. the spray machine should be of are putted majufacturer with pro-guard technology and capability of traking pressure as well as paint and primer usage. (f) This equipment shall be certified by approved manufacturer. (g) The accessories for applying the finishes shall be spray in hard to reach areas ad penetration of finishes on the surface so as to achieve uniform appication and quality surface finish. Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix \"CD\" on page no. 112of tender documents as per Sch \"A\" Note No 19 Page No 17). |
| 76 | Material & Labour for RCC chajja/fascia/parapet repair by using following steps :-(a) Removal of existing concrete along with loose damaged and cracked concrete/cover concrete from chajjas etc, exposing corroded steel reinforcements upto a depth of 10mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chippers including high pressure water jetting to chipped concrete and reinforcement all as directed by Engineer-in-charge. Hard concrete shall not be removed. However if the rebar is corroded, concrete around it shall be removed.(b)Cleaning the surface of reinforcement bars from dust by using wire brushes and dry cloth and applying FOSROC Rebakleens RR- Rust Remover or equivalentusing small brush and allow to react it for 16-24 hrs. (c) Providing and applying two coats of Fosroc Nitozinc Primer - two component, zinc rich epoxy, anti-corrosive protective coating or equivalentby brushes to the exposed and cleaned rebars with an interval of 45minutes to 1 hour @ 40microns DFT / coat and allowed to completely dry for 24 hours all as directed by Engr-in-Charge. |
| 77 | Material and labour for complete removal of existing treatment including fascias, cornices etc by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\"/9\" to make the surface free from dust, loose paint and loose plaster to be completely removed by skilled labour and repair of external wall/ chajjas to be done with repair mortar to get even surface including preparation of old surface of wall/ ceiling by filling cracks by Berger Bison Putty/ crack fill paste of Berger Paints or equivalent make and make good smoothen surfae by sand paper and applying two coats of premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance of Berger Paints Ltd or equivalent of other approved make with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water based exterior grade primer @ 0.9 ltr (undiluted)/10 sqm mtrs diluted with water in 1:1 ratio as per manufacture\"s instruction and all coats incl primer to be applied with fuly automatic airless spray machine of paint appliaction with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI all as specified and directed.Allow 6-8 hrs to dry the surrface in subsequent coats of paint and including necessary scaffolding at any height complete all as specified and directedMake : Berger Paints Weathercoat Long Life Flexo/ Nerolac Paints excel Total/ Asian Paint Apex Ultima/ JK Maximo Ultra Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix \"CD\" on page no. 112 of tender documents as per Sch \"A\" Note No 19 Page No 17). |
| 78 | M&L for preparation of new wooden surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed |
| 79 | M&L for Preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed |
| 80 | M&L for sand filling under floors or in foundations including watering and consolidation as required complete all as specified and directed. |
| 81 | M&L75 mm thickcement concrete type C-2 1:3:6 (40mm graded aggregate) as in sub base complete all as specified and directed. |
| 82 | M &L 25 mm Thick PCC type B-0 1:2:4 (12.5mm graded aggregate) as in flooring, under Tiles etc complete all as specified and directed |
| 83 | M&L for 20 mm thick screed bed or bedding layer of mortar in CM 1:4 for laying floor finishes complete all as specified and directed |
| 84 | M&L for 10 mm thick screed bed or bedding layer of mortar in CM 1:3 as on vertical surfaces for laying wall finishes complete all as specified and directed |
| 85 | M&L for hard core of gauge n.exc 63mm deposited, spread and leveled in layers n.exc 15cm thick watered and rammed to a true surface with broken stone aggregate complete all as specified and directed. |
| 86 | M & L 75 mm thick Cement concrete workas in plinth protection type C-1 , 1:3:6 (20mm graded aggregates) with finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 87 | M&L for brushingneat cement slurry with 3.0 kg of cement per sqm complete all as specified and directed |
| 88 | M&L for machine cut Kota stone slab flooring, 20-25 mm thick over cement screed bed laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete all as specified and directed |
| 89 | Ditto all as per item sl no 88 here-in-before but on vertical surfaces such as in riser, skirting etc complete all as specified and directed |
| 90 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-35 Grade add with grey cement and pigment complete all as specified and directed. |
| 91 | M&L75 mm thickPCC1:4:8 type D-2 using (40mm graded crushed stone aggregate ) as in sub base of floor completeall as specified and directed. |
| 92 | M&L for earth Soilspreading , levelling in layers n.exc 25 cm thick each layer with well ramming including watering as required under the floor complete all as specified and directed by Engr -in Charge. (Note :- Earth Soil available surplus soil from the excavationat ground ) |
| 93 | S & F of rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete, drilled for fixing of steel sheeting or other covering doors etc. to be prepared for hanging orsteel hanging door fitting and also fastening complete all as specified and directed. |
| 94 | M&L for Shower rose of C.P. swival joint of size 125mm for fixing 15mm pipeincluding fixing to steel pipe or union fixed in repairs all as specified and directed. |
| 95 | M&L for PVC connections 15mm dia & 600mm long with PTMT nuts all as spd & directed |
| 96 | M&L for Box type steel windows comprising of tubular frame and shutters made out of 1.25mm thick MS steel tube, factory made, with double side shutters wire gauged shutter and glass glazed shutter (wire and glass panes shall be measured and paid separately) with side hung shutters with steel handle and steel peg stay dovetailed or welded including 2 Nos tower bolts 150 mm long for each leaf and 8mm square bar grills at spacing as shown on drg welded to F1 frame work, including other fittings, hinges, handles tarred hold fasts PCC blocks etc all as shown on Drawing No CEPZ/TD-354/09 sheet 1/3 to 3/3 including taking down old steel window of any size complete all as specified and directed. |
| 97 | S & F600mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 98 | S&F Peg stay Cloth Hanger 30 to 60 cm long between Hangs, fixed in repairs complete all as specified and directed. |
| 99 | Complete removal of existing roof treatment or roof tile and removing from site to a place outside defence land as specified by civil authorities and clean the surface of roof with water and remove dust complete all as specified. |
| 100 | Cleaning of the exposed concrete slab and repairing the surface irregularities like cracks, potholes, as per manufacturers method statement by Berger HS Rapairo(or equivalent)along with HS Latex Plus(or equivalent)& cement in mixing ratio of 1:4 where ever required |
| 101 | M&L for Home Sheild PU Roofkoat (or equivalent) is a one component liquid, solvent free, cold applied water-proofing membrane that is highly elastic and UV resistant with 10 years warranty. ASTM D 6083-97 a waterproofing and heat reflecting system having following key performace properties : 1. UV resistant, prevent yellowing and weathering2. Highly elastic upto 350% and crack bridging3. Excellent adhesion on porous and non-porous substrates4. Tensile strength > 10 N/mm2 with Geo Textile fleece5. Soler reflective Index(SRI) more then 109-111 ASTM E 1980-11 System :First coat : Providing and applying primer over the prepared surface with HS PU roofkoat Primer (or equivalent)Coverage :0.2kg/m2 (with 50 % dilution of water)Reinforcement : Geotextile 40 gsmSecond coat : Home sheildroofkoat (or equivalent)Consumption : 0.5 kg/m2Third coat : HS PU roofkoat (or equivalent)Consumption : 0.8 kg/m2 System buildup-1.5kg/sqm with geotextile of 40 gsmFor accessible roof, tiles with scred/ adhesive may be fixed thereafter.Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix \"EF\" on page no. 116 of tender documents as per Sch \"A\" Note No 19 Page No 17). |
| 102 | M&L for Providing cement concrete type B-0 1:2:4 (using 12.5 mm graded stone aggregate ) in roof padding, roof kerbs or mud stops, rounded or chamfered on edges finished even and smooth without using extra cementcomplete all as specified and directed. |
| 103 | Dismantling floor, hearth or wall tiling , terrazzo topping on wallsincluding cement mortar ,bedding (but no backing) removing serviceable tilesand rubbish off the premises complete all as specified and directed. |
| 104 | M&L for Non Skid joint freeceramic tiles 300 x 300 x 7 to 8 mm thickin floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchover screed bed or bedding layer of mortar 15mm thick in cement mortar 1:4 all as specified and directed. |
| 105 | M&L for Glazed ceramic coloured tiles of size450X 300X 7mm thick as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed. |
| 106 | M & L Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but notexceeding 0.18 sqm, in floors etc, setand jointed in neat cement slurry and pointed in white or Coloured cement to match laid over 15 mm thick avg screed bed in CM 1:6 complete all as specified and dirtected. |
| 107 | S&F for PVC (SWR) pipes 75 mm bore single socketed in any length with rubber ring joints fixed to wallincluding fixing clamps complete all as specified. |
| 108 | S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches. |
| 109 | PVC (SWR) bends any radius 75mm borecomplete all as specified and directed. |
| 110 | S & F 75 mmdia PVCcowls complete all as specified and directed. |
| 111 | S & F 75mm dia PVC floor trap , with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed. |
| 112 | S & F 75mm dia PVC multi floor trap floor trap , with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed. |
| 113 | S & F PVC (SWR)junction single(single T) equal or unequal 75mm bore all as specified and directed |
| 114 | S & F PVC (SWR) bends any radius 110mm bore complete all as specified and directed. |
| 115 | S & F PVC (SWR)junction single(single T) equal or unequal 110mm bore all as specified and directed |
| 116 | Dismantling cast iron or reinforced concrete drain pipes of 100mm bore, fixed with walls and taking out of trenches, if required all as specified and directed. |
| 117 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m depth, for foundation etc or for shafts, manholes, etc not exc 10.00sqm on plan and not exc 1.5m depth and getting out in any type of soilcomplete all as specified and directed |
| 118 | Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m depth and not exceeding 3m for foundation, manholes, etc., and getting out in any type of soilcomplete all as specified and directed. |
| 119 | Returning filling in, including spreading, levelling watering and well ramming in layer not exc 25 cm thickcomplete all as specified and directed. |
| 120 | Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and as directed. |
| 121 | Demolition and breaking up drain pipes 200mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, complete all as specified and as directed. |
| 122 | Demolition and breaking up drain pipes 150mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, complete all as specified and as directed. |
| 123 | M&L for concrete bed to drain pipes including packing under, and haunching againstthe sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate for 200mm dia bore pipes allas per SSR Part-I specifications, complete all as specified and directed. |
| 124 | M&L for Concrete bed to drain pipes including packing under, and haunching againstthe sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregatefor 150mm dia bore pipes allas per SSR Part-I specifications, complete all as specified and directed. |
| 125 | S & F 200 mm dia DWCPE (SN8) HDPE pipes laid in trenches on PCC bed incl jointing as per manufactures instructions and as complete all as specified and directed. (Benching/ haunching and earthwork paid separately under respective items of schedule) |
| 126 | S & F 150 mm dia DWCPE (SN8) HDPE pipes laid in trenches on PCC bed incl jointing as per manufactures instructions and complete all as specified and directed. (Benching/ haunching and earthwork paid separately under respective items of schedule) |
| 127 | M&L for Cutting into existing manholes for connecting new drains (internal dia of pipe 200mm), making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as requiredfor (100/150/200) pipe complete all as specified and directed. |
| 128 | M&L for Cutting salt-glazed stoneware drain pipe in position new drains (internal dia of pipe 100mm), making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed. |
| 129 | Demolition of unreinforced cement concrete in ground floors & pavings not exceeding 15cm thicknes (below or above ground level) complete all as specified and directed. |
| 130 | Demolition of reinforced cement concrete of any description not otherwise specifically provided for (reiforcement cut to facilitate demolition) complete complete all as specified and directed. |
| 131 | Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches pillarsetc, complete all as specified. |
| 132 | M&L for Brick work with sub class\"B\" bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 133 | M&L for Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4, complete, but except brick, i.e. using serviceable bricks obtained from Serial Item No \"15.00\" here-in-before all as specified and as directed. |
| 134 | M & Lfor Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4, in half brick thick complete all as specified and directed by Engr-in-Charge. |
| 135 | M & Lfor Cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed. |
| 136 | M & Lfor Plain cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in benching, water troughs and the like including form work and finishing all exposed surfaces of concrete, complete all as specified directed. |
| 137 | M & Lfor Plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregates) as in copings, lintels upto 1.50 metre clear span, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, kneelers, apex stones, bed plates, kerbs etc. and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form work complete all as specified directed. |
| 138 | M & Lfor Precast cement concrete 1:2:4 type B-I (using 20 mm graded stone aggregate) as in cover slabs (for manholes etc.), chullah hoods, chajjas, shelves and similar articles with plain faces, set in cement mortar 1:4 complete all as specified directed. |
| 139 | M&L for Cleaning / clearing of sewage line (including manholes) 100mm to 200mm bore of any description, underground at any depth, removing any type of blockage including desilting, descaling & de-chocking of drains as well as manholes with combined high pressure water jetting cum suction (vaccum) type machine mounted on LCV / HCV and having facilities of high pressure vaccum and provision of hydraulic application through high pressure thermo plastic fiber based water jetting hose and conical round shape nozzle pipe and flushing after cleaning including removing the same in the tank to a place outside cantonment at the place meant for the purpose by local municipality, all as directed. |
| 140 | All as per the description of Serial Item No 139 here-in-before but cleaning done manually by labour complete all as directed by the Engr-in-Charge. |
| 141 | M&L for desludging / dewatering of septic tanks/ soakage wells includinginlet / outlet chambers, removing out all scum, silt, residual sludge (both organic & inorganic in nature) after plugging the incoming sewage lines through combined high pressure water jetting cum suction (Vacuum) type machine mounted on LCV/HCV facility of high pressure vacuum and removing the same in the tank to a place outside cantonment at the place meant for the purpose by local municipality, complete all as specified & directed. |
| 142 | All as per the description of Serial Item No 141 here-in-before but cleaning done manually by labour complete all as directed by the Engr-in-Charge. |
| 143 | S & F of viterous china urinal, half stall type, whitewith grating and union for discharge pipe, complete including providing and fixing plugs, beding urinal against wall in cement mortar 1:2 securing urinal plugs with and including 60mm long brass screws, pointing around urinal back in cement,with flush pipe, waste coupling and urinal spreader, fixed in repairs, complete all as specified & directed. |
| 144 | E/M Portion |
| 145 | Takingout carefully copper/aluminium point wiring,Light,fan,socket or powercomplete with all fitting, fixtures such as switch socket out let, ceiling rose ,holder ,regulator,DBs etc including making good the disturbed surface of wall/floors complete |
| 146 | Taking down distribution boards/wooden board ,switch fuse units,steel enclosures for MCB of any type and removing from site all as specified and as directed by the Engineer in charge. |
| 147 | Taking down existing unserviceable submain wiring any size and making good the disturbed surface all as specified and as directed. |
| 148 | Material and labour for point wiring for one light controlled by one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn through and includingrigid non metallic PVC concealed conduit (medium grade) of suitable dia along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and includingpressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for mounting switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good disturbed surface all as specified and as directed. |
| 149 | All as per item no-148 above but for one Exhaust fan point controled by one piano switch all as directed. |
| 150 | All as per ser itemno-148 hereinbefore but for one 3 pin socket outlet 5 Amp Same. |
| 151 | All as per ser item No 148 hereinbefore but for one 3 pin socket outlet 5 Amp independent. |
| 152 | All as per Itemno-148 here-in-before but for one15 Amp 3pin switch socket outlet, independent with 4 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 2.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed. |
| 153 | Supply and fix modular type switch, one way 6 Amps , 1 module complete all as specified and directed. |
| 154 | Supply and fix modular type switch, Two way 6 Amps , 1 module complete all as specified and directed. |
| 155 | Supply and fix modular type switch, one way 16 Amps, 1 module complete all as specified and directed. |
| 156 | Supply and fixmodular type socket 5 pin, 6 Amps 2 module complete all as specified and directed. |
| 157 | Supply and fixmodular type socket 5 pin, 6 A/16 Amps2 module complete all as specified and directed. |
| 158 | Supply and fixof Ceiling rose surface bakelite three terminals 240 volts complete, all as specified. |
| 159 | Supply and fix of Lamp holder PVC case body of Bakelite with back plate suitable for batten fittings , all as specified. |
| 160 | Supply and fix ofSwitch piano flush type single pole, one way 5 Amp , all as specified. |
| 161 | Supply and fix of Switch socket out let combination universal type, 2 in 1, 2 and 3 pin 5 Amp, piano flush type, 240 volts, complete all as specified and as directed at site by the Engrs-in-Charge. |
| 162 | Supply and fix of Switch socket outlet combination universal type, 2 in 1, 3 pin 5 and 15 Amp, piano flush type, 240 volts, complete all as specified and as directed at site by the Engrs-in-Charge. |
| 163 | S&F Electronic fan regulator stepped typewith five step 240 volts suitable for 1200/1400 mm sweep AC ceiling fan, complete all as specified & directed |
| 164 | Supply and fix in repair LED lamp,6500K,900lm in white colour of 12 Watt base cap B-22 with poly carbonate difusser and aluminium heat sink ,complete all as specified & directed. |
| 165 | S&F LED lamp,6500K,900lm in white colour of 9 Wattbase cap B-22 with poly carbonate difusser and aluminium heat sink ,complete all as specified & directed. |
| 166 | Supply and fix of Tube light fitting integrated type suitable for LED 20W indoor decorative aluminium extruded T5 LED batten complete with hosing with all accessories pre wired and making connection with threecore copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting complete all as specified and directed. |
| 167 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 168 | Supply and fix IP 66 Integral LED security light luminaire 35W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & heat resistanttoughned glass ,efficacy 110 lumens/watt, external 10KV,440 volt SPD and inbuilt 4KV , IP 67 potted isolated driver with operating range 902V to 340V AC .CCT 5700K,LED life -1 lakh burning hours,fixture should withstand 320 volt upto 48 hrs , Auto cut off >320 volts & restart,440 Volt sustainupto 8 hrs,NABL Acreddited LM79 report including GI pipe 40mm ,medium grade ,1.7mtr long mounting bracket and providing fixing clamps ,bolts,nuts of suitable sizecomplete all as specified and as directed. |
| 169 | Material and labour for sub main wiring with Four single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm and two single core PVC insulated (unsheathed) solid copper conductor FRLS cable of size 4 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement moter 1:3 and making good disturbed surface complete all as specified and as directed. |
| 170 | Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm and one single core PVC insulated (unsheathed) solid copper conductor FRLS cable of size 4 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement moter 1:3 and making good disturbed surface complete all as specified and as directed. (for Geyser) |
| 171 | Supply and fix of Factory made flush shutter type sheet metal enclosures, double door,forMCCB DB load link, Vertical, triplepole and neutral, 4 way IP-43,Suitable for MCCB up to 100A as incommer complete all as specified and directed. |
| 172 | Supply and fix of Thermal magnetic release MCCB 4 pole 415 volt rapturing capacity 16 KA 0f size 63 amp complete all as specified and directed. |
| 173 | Supply and fixof MCB SP-06 to 32 Amp, 240 volts complete all as specified and directed. |
| 174 | Supply and fix of MCB SPN-32 Amp, 240 volts 50Hz AC supply, complete all as specified and directed. |
| 175 | Supply and fix of Sheet metal enclosure IP-43 double door for DBs(where MCBs arereqd) SPN 240 V, for 4 ways, complete all as specified.and directed |
| 176 | Supply and fix of Sheet metal enclosure IP-43 double door for DBs(where MCBs arereqd) SPN 240 V, for 8 ways with suitable busbar, complete all as specified and as directed. (For T-22 T-23 & T-75) |
| 177 | Supply and fix in repairs factory made epoxy powder coated Distribution board SPN 12 ways (SPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 100 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cale management, top and bottom removable gland plates with Knockouts and suitable for one SPN/DP-MCB as incomer and SP MCBs outgoing complete all as specified and confirming to IS : 8623 complete all as specified and directed. |
| 178 | M&L for Earthing complete with galvanized mild steel earth plate electrode size 600x600x6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 part-I, connected to test point complete, all as specified and testing on completion complete all as specified and directed. |
| 179 | M&L forExhaust Fan, 450mm(18\") sweep, single phase, 230 volts 50 Hz AC,1400 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings complete with louvers and shutters including cutting hole for fixing exhaust fan to wall and making good the disturbed surfaces (including plastering, necessary brickwork and distempering) to match with the existing specification, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site and as directed. |
| 180 | S & F of exhaust Fan steel body, 300mm(12\") sweep, single phase, 230 volts 50 Hz AC,1400 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings complete with louvers and shutters including cutting hole for fixing exhaust fan to wall and making good the disturbed surfaces (including plastering, necessary brickwork and distempering) to match with the existing specification, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site and as directed. |
| 181 | Supply and fixing ceiling fan BEE 5 star (BLDC) rated super energy efficient electric driven ceiling fan with double ball bearing 1200mm (48 inch) sweep,copper wound stator ( with brudhless direct current motor) having three blades made of aluminium alloy suitable for operation on single phase 140-285 Volts, AC ,50Hz , with power factor not less than 0.99,service value minimum 8 Cu.metre / Min/Watt or higher ,air delivery minimum 230 cubic metre per minute or more ,power consumption maximum 28 watts or lower , top speed minimum 350 (+/-) 10% RPM or higher, speed control by 5 step regulator with copper winding complete as per IS:374-1979 or latest IE rulecomplete all as specified and directed. |
| 182 | Supply, installationand testing of water heater storage type (Geyser), single phase 230V, 50Hz, 5 star energy saving high density PUF insulation tank made of heavy duty magnesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type, 50 Litre capacity, 2000Watt rated power, incoloy 800 glass coated heating element, inner tank coating of ferro glass powder, tank made of ultra thick super cold rolled steel plates, rated pressure 0.8MPa, IPX4 protectionconsist of safety valves, thermal cut off, thermostat including connecting up and fixing arrangement on wall including providing hole fastners - 04 Nos, hot & cold water metallic flexiblepipes 15 mm bore of adequate length as provided by OEM or required at site - 2 Nos, non return valve 01 No and including necessary plumbing work, complete with integrated shock safeplug with all protection features as per OEM design and standard design and standard, complete all as specified and as directed. |
| 183 | Supply,install and testing water heater storage type(Geyser)single phase 230V,50Hz ,5 star energy saving high density PUF insulation tank made of heavy duty magnesium anode rod with steel core to protect enamelled tank from rust & corrosion ,vertical installation type, 25 Litre capacity,2000Watt rated power,incoloy 800 glass coated heating element,tank coating of feroglas powder,tank made of ultra thick super cold rolled steel plates,rated pressure 0.8MPa,IPX4 protectionconsist of safety valves,thermal cut off, thermostat including connecting up fixed to walls by drilling of holes ,grouting of bolts of suitable size with nuts etc and makinggood disturbed surface complete all as specified & directed. |
| 184 | Cutting existing steel tubing15 mm bore for alterations or additions (Each cut measured) complete all as specified and directed. |
| 185 | Screwing existing steel tubing 15mmfor alterations or additions. |
| 186 | S & F Tubes medium grade galvanized 15 mm dia with fittings such as socket, bend and fixed complete to walls and ceilings complete all as specified and directed. |
| 187 | S&F Stop valve/angle valve cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe of four unions and fixed complete all as specified and directed. |
| 188 | S&F Bib tap 15mmchromium platedcast copper alloy with crutch or butterfly screwed down for iron pipe and fixed complete all as specified and directed. |
| 189 | Supply and fix sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole mcb complete all as specified and directed. |
| 190 | Supply, laying underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium stranded conductor, Armoured cable 25 sq mm 4 core cable confirming to IS-7098 Part-I (1988) with latest ammendments of size complete all as specified and directed. |
| 191 | Material and labour for cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 16Sqmm 2 Core, including glands, lugs, nut, bolts, washers as required at site, testing complete all as specified and directed. |
| 192 | Supply and laying cable XLPE insulated armoured cable heavy duty 1100 Volts of size 10 Sqmm 2 core complete all as specified and directed. |
| 193 | Material and labour for cutting of bituminous road / floor / culvert / PCC hard standingfor laying of pipe / cables not exceeding 1.5 meter wide and not exceeding 1.5meterdeep including refilling / with material and, watering well ramming / compacting and making good with PCC 1;2;4,type B-1, 100 mm thick complete all as specified anddirected. |
| 194 | Supply & laying dry river sand as cable cushioning 15cm thick layer before laying and 8cm thick over cable after laying the cable in trench complete all as specifieds and directed. |
| 195 | M&L for well burnt sub class \"B\" bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick complete all as specified and directed. |
| 196 | Material and labourfor GI pipe \"\"light grade\"\"for road crossing / on wall / on pole with fixed clamps, nuts, boltsfor cableprotectionof size25 mm dia complete all as specifieds and directed. |
| 197 | Material and labourfor GI pipe \"\"Medium grade\"\"for road crossing / on wall / on pole with fixed clamps, nuts, boltsfor cableprotectionof size50 mm dia complete all as specifieds and directed. |
| 198 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 199 | Supply and fix of Sheet metal enclosure IP-43 double door for DBs(where MCBs arereqd) SPN 240 V, for 4 ways, complete all as specified.and directed |
| 200 | Supply & fixing MCB Single Pole and Neutral (SPN) of capacity 32Amps , 240 volts in proper position all as specified and as directed |
| 201 | Supply & fixing MCB Single Pole (SP) of capacity 6 to 32 amps , 240 volts in proper position all as specified and as directed |
| 202 | Dismantling and taking out rusted/corroded pipe GI/CPVC of size 20/25/40/50mm bore complete all as specified and directed. |
| 203 | M & L of tubing GI \"MG\" with all fittings laid in floor or trenches including taking out old UNSV pipe of size 50 mm dia complete all as specified and directed |
| 204 | M & L of tubing GI \"MG\" with all fittings laid in floor or trenches including taking out old UNSV pipe of size 25 mm dia complete all as specified and directed |
| 205 | M & L of gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of size 50 mm bore |
| 206 | M & L of gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of size 25 mm bore |
| 207 | Cutting existing 80/100/150 mm GI pipe and inserting GI Tee of size 100x100x50 mm for tapping including necessary earth work and making flange for connection of new 50 mm of GI pipe including all as specified and directed . |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy