| 1 | Demilotion of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 2 | M&L for 75mm thick cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base of hardstanding complete all as specified and directed. |
| 3 | M&L for machine pressed precast cement concrete interlocking paver block of size confirming to IS-15658-2006 of 60 mm thickness, M-35 grade with grey cement and with pigment or without pigment.Note : Shape and size approved by GE. |
| 4 | M&L for providng 25mm thick sand crushioning under interlocking tiles complete all as specified and directed |
| 5 | M&L for chequered cement concrete tiles 30cmx30cmx25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigments and including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6 complete including demolition of old unserviceable tiles all as specified and as directed |
| 6 | M&L for 75mm thick PCC type C-2, 1:3:6 (using 20mm grade aggregate) as in path hardstanding including finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 7 | 18mm thick granite any colour machine cut, such as in steps, platform, vertical surfaces laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 15mm thick screed bed on fair faces of brickwork or conctrete surface in CM 1:3complete all as specified and directed |
| 8 | M&L for old size brickwork in subclass \"B\" bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 including demolition of brickwork or stone/boulder masonry, built in cement mortar including all quions, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed |
| 9 | M&L for brickwork with sub class \"B\" bricks, straight or curved on plan to any radius in half brick thick wall built in CM 1:4 including demolition complete all as specified and as directed. |
| 10 | M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in cm 1:4 complete all as specified and directed |
| 11 | M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in cm 1:4 including taking down old finishes, complete all as specified and directed. |
| 12 | Removing building materials etc. to a distance of 200 mtr, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed complete all as specified and directed. |
| 13 | S&F PVC pipes, single socketed, in any length with rubber ring 110mm dia fixed in wall including taking down complete all as specified and directed. |
| 14 | M&L forpreparation of old surfaces of wall and applying one coat of colour wash on old decorated surface of wall complete all as specified and directed. |
| 15 | M&L forpreparation of new surfaces of wall and applying two coats of colour wash on Undecorated surface complete all as specified and directed. |
| 16 | M&L for precast cement concrete type B1 1:2:4 (20mm graded aggregate) in landings, cover slabs, drain, chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete including demolition of old RCC work all as specified and directed. |
| 17 | Taking down & Re-fixing precast cement concrete cover slab in cement mortar 1:4 of any shape and size complete all as specified and directed |
| 18 | Taking down & Re-fixing machine pressed precast concrete interlocking paver block of any shape and size conforming to IS-15658-2006 of 60mm thickness, M-35 grade with grey cementpigment including 25mm thick sand crushioning under interlocking tiles complete all as specified and directed. |
| 19 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 20 | M&L for cement concrete type D2 1:4:8 (40mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 21 | S&F TMT mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, beinding spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe 290(Gde E-165) complete all as specified and directed. |
| 22 | S&F TMT mild steel bars, 6 mm to 8 mm dia and over, cut to length, bent to shape required, including cranking, beinding spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe 290(Gde E-165) complete all as specified and directed. |
| 23 | M&L for form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 24 | M&L for formwork to sides of pillars, posts, struts, piers,columns and stanchions complete all as specified and directed. |
| 25 | M&L for Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 26 | M&L for Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc complete all as specified and directed. |
| 27 | Dismantling including cutting wrought iron or mild steel work of any description not other wise provided for complete all as specified and directed. |
| 28 | S&F for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161 1979 grade St.-240 complete all as specified and directed. |
| 29 | M&L for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates; hook and pintle hinges large hasps and staples; chains; hand made sliding bolts; mps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 30 | M&L PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in surface channels, drains, complete all as specified and directed. |
| 31 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |