| 1 | Excavation in trenches not exceeding 1.5 metrewide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays etc. and getting out soft/loose soil, complete all as specifiedand directed by the Engineer-in-Charge. |
| 2 | Excavation in trenches not exceeding 1.5 metrewide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays etc. and getting out hard/dense soil, complete all as specifiedand directed by the Engineer-in-Charge. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge. |
| 4 | Removing excavated material not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and as directed by Engineer-in-Charge. |
| 5 | M&L for sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable, complete all as specified and directed by Engineer-in-Charge.Note: Punned thickness of sand shall be measured. |
| 6 | Taking out oldunreinforced precast concrete cable coverclass LV type1 flat size 250x150x40 mmduring excavation of trenches completeall asspecified and directed. |
| 7 | S&F unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mmduring excation of trenchesall asspecified and directed. |
| 8 | Taking downGI pipelaying in trenches for UG cable protectionof any sizes pipe complete all as specified and as diercted. |
| 9 | Supply and lay in trenches / along the wall / floorpipes GI light grade of size 80 mm with and including all fittings and accessories complete all as specified and and directed for cable protection complete all as specified and directed. |
| 10 | Supply and lay in trenches / along the wall / floorpipes GI light grade of size 40 mm with and including all fittings and accessories for cable protectioncomplete all as specified and directed. |
| 11 | Supply and lay 80 mm outer dia double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & IS14930 ( Part I and II) for protection of underground cableswith all fittings. laid in trenches / road or fixed along wall. poles or laid under floor and making good to match with existing adjoining surface etc for cable protection all as specified. |
| 12 | Taking downany sizes ofof LT UG cable XLPE with aluminum conductor multistranded ,PVC insulated and PVC sheeted heavy duty 1100 Volts grade under ground cable complete all as specified and as directed. |
| 13 | Supply and laying cable XLPE Insulated armored, heavy duty electric power cables (heavy duty) 1100 Volts grade cross sectional area with stranded aluminium conductor of size 10 sq mm 2 Core complete all as specified and directed. |
| 14 | Supply and laying cable XLPE Insulated armored, heavy duty electric power cables (heavy duty) 1100 Volts grade cross sectional area with stranded aluminium conductor of size 16 sq mm 2 Core complete all as specified and directed. |
| 15 | Supply and laying cable XLPE Insulated armored, heavy duty electric power cables (heavy duty) 1100 Volts grade cross sectional area with stranded aluminium conductor of size 10 sq mm 4 Core complete all as specified and directed. |
| 16 | Supply and laying of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables (heavy duty) 1100 Volts grade cross sectional area with stranded aluminium conductor of size 16 sq mm 4 Core complete all as specified and directed. |
| 17 | Supply and laying of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables (heavy duty) 1100 Volts grade cross sectional area with stranded aluminium conductor of size 25 sq mm 4 Core complete all as specified and directed. |
| 18 | Supply and laying of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 35 sq mm 3.5 Core complete all as specified and directed. |
| 19 | Supply and laying of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 95 sq mm 3.5 Core complete all as specified and directed. |
| 20 | Supply and laying of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 70 sq mm 3.5 Core complete all as specified and directed. |
| 21 | Supply and laying of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 50 sq mm 3.5 Core complete all as specified and directed. |
| 22 | Supply and laying of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 150 sq mm 4 Core complete all as specified and directed. |
| 23 | Supply and laying of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 150 sq mm 1.0 Core complete all as specified and directed. |
| 24 | Supply and laying of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables (heavy duty) 1100 Volts grade cross sectional area with stranded aluminium conductor of size 120 sq mm 3.5 Core complete all as specified and directed. |
| 25 | S&F copper cable flexiblePVC insulated 3 x 2.5 sqmm single core along with earth wire in PVC conduit from FRP box to flood light/street light fitting ,including aluminium flat clamp 25 X 4 mmwith suitable nuts,bolts and washers etc all as specified and directed . |
| 26 | S&F copper cablePVC round sheathed (flexible) industrial cable4 core x 10.0 sqmmfor high mast lights/street light maintenance all as specified and directed. |
| 27 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor 10 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular all as specified and directed. |
| 28 | S & F Rigid non-metallic concealed PVC conduit 20 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.complete all as specified and as directed. |
| 29 | M&L cable jointing kitfor 1100 volts grade cable for straight through heat shrinkable typejoint, complete with and including jointing material and accessories suitable for 3.5 core XLPE armoured aluminium cable of size 25 Sqmm to 50 Sqmm, also with and including connecting single ferrules/thimbles etc after disconnecting of electric supply including burnt out jointing kit etc, complete all as specified and directed. |
| 30 | M&L cable jointing kit1100 volts grade cable for straight through heat shrinkable typejoint, complete with and including jointing material and accessories suitable for 3.5 core XLPE armoured aluminium cable of size 70 Sqmm to 95 Sqmm, also with and including connecting single ferrules/thimbles etc after disconnecting of electric supply including burnt out jointing kit etc, complete all as specified and directed. |
| 31 | M&L for cutting existing road/hard standing not exc 50x60 cm in wide & depth getting out excavated material for laying GI tube , for passing through LT cable, returning filling & well rammaing wateringfinish suraface 10 cm from top using plain cement concrete 1:2:4 type type B1 (using 20 mm graded stone aggregate ) finishing the surface even and smooth without using extrac cement including removal of surplus soil obtained form surface cutting complete all as specified and directed. |
| 32 | Demolation of Cement concrete in ground floor and paving n.exc 15 cm thickness (below or above) ground level including removal all as specified. |
| 33 | M&L for 100mm thick plain cement concrete 1:3:6 type C2 (using 20 mm graded stone aggregate) as in flooring finishing the surface even and smooth without using extrac cement complete all as specified and directed. |
| 34 | Taking down any type any breaking capacity MCCB complete all as specified and as directed. |
| 35 | S & F in replacement MCCB 415 volts grade with adjustable short circuit and over load of following rating :- |
| 36 | 63 Amps, 16 KA, 3 Pole. |
| 37 | 100 Amps, 16 KA, 3 Pole. |
| 38 | 125 Amps, 16 KA, 3Pole. |
| 39 | 160 Amps, 36 KA, 3 Pole. |
| 40 | 200 Amps, 36KA, 3 Pole. |
| 41 | Supply ,fabricte & InstalledLT Distribution Panel (CPRI Approved) Pedastal type outdoor type factory fabricated made out of 3 mm thick CRCA Sheet , size not less than 2.0 M x 0.90 M x 1.50 M & suitable size to accommodate allaccessories/fittings,compartmentalized in construction to accommodate incomming MCCB\"s and TPN Aluminium Bus Bars of suitable capacity of 400 Amps. The TPN Bus Bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50x50 mm conical type at an interval of not more than 500 mm through out the lenth of the TPN Bus bar.The incoming as well as outgoing MCCBs shall have Aluminium extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders.The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables.All extension links/interconnection shall colour coded sleeves.The cubical shall have a bottom channel of size75x40 mm duly coated with zinc metal coating. A detachable predrilled gland plate of thickness not less than 3 mm thick zinc metal coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be frontopenable by double door formand shall have louvers and airvent gasket for Natural flow of airadhesive type gasket shall be used to makepanel vermin proof,and panel shall be cold Zinc (for rust proof) sprayed thicknesscomplete all as specified, Panel mounted on 50x50x5 mm sizeMS angle iron frame duly painted including PCC 1:2:4 type B1(using 20 mm graded stone aggregate) in foundation andcomprising of the following items :- |
| 42 | (i) Al bus bar 600 Amps CU INCOMER(ii) 400A 4 Pole 36 KA MCCB-1 No METERING (i) Digital Voltmeter (0-500V)-1 Nos(ii) Digital Ammeter (0-200A)-1 Nos(iii) R/Y/B Indication Lamp 1Set -1 Nos(iv) Current Transformer (200/5A) 3-Nos(v) Control fuse witth base (2/20A)-6 NosOUTGOINGChange over switch of 200 Amps rating - 1 Nos(i) 200A TPN 36 KA MCCB - 1 Nos(ii) 160A TPN 16 KA MCCB - 1Nos(iii) 63A TPN 16 KA MCCB - 2 Nos(iv) 40A TPN 16 KA MCB - 2 Nos (v) 32A SPN 10 KA MCB - 2 Nos (v) 70A TP ML 4 Power contactor- 1 Nos(vi) 24 Hrs timer analog type (L&T) - 01 Nos |
| 43 | S & F timer switch with astronomical timer switch min 8KW, 3 pole, 230 V suitable for street light control including all assessories complete set all as specified and directed. |
| 44 | S & F power contactor MN 32, 3 pole for controlling street light switching circuit including all assessories complete set all as specified and directed. |
| 45 | Supply and fixingin repairs/Replacement ofof the undermentioneditems to be incorporated in street light fittings including taking down street light from pole andrefixing it on pole after replacement of driver complete all as specified and directed :- |
| 46 | LED Driver for 1 x 60 watt LED street light complete of make -Crompton/Bajaj/Havells. |
| 47 | LED Driver for 1 x 90 watt LED street light complete of make -Crompton/Bajaj/Havells. |
| 48 | LED Driver for 1 x100 watt LED flood light complete of make -Crompton/Bajaj/Havells. |
| 49 | LED Driver for 1 x200 watt LED flood light complete of make -Crompton/Bajaj/Havells. |
| 50 | S & F in replacement street light timer, single phase for 8 KW light load comprising of nature switch, contactor and MCB housed in a pole mountable enclosure complete all as specified and directed |
| 51 | Supply and fixing in replacement LED street light fitting 90 Watt 230 V, surge protection 10 KVA, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.& Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 1 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed. |
| 52 | Supply and fixing in replacement LED street light fitting 60 Watt 230 V, surge protection 10 KVA, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.& Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 1 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed. |
| 53 | Supply and fixing in replacement post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete.complete all as specified and directed. |
| 54 | Supply & fixing in replacement LED land scape light/bollard light/garden lightwith excellent light output through its sleek PMMA window ensuring max illumination aspect in surrounding, 10W/9 W with 900mm height extruded aluminium cylindrical section housing IP-65 rated complete with base & log bolt grafite grey epoxy cationic powder coated all accessories including PCC foundation for fixing arrangement on groundcomplete all as specified. and directed . |
| 55 | S&F copper cable flexiblePVC insulated 3 x 1.5 sqmm single core along with earth wire in PVC conduit from FRP box to street light fitting ,including aluminium flat clampt 25 X 4 mm -03 Nos with suitable nuts,bolts and washers etc all as specified and directed. |
| 56 | S&F copper cablePVC round sheathed (flexible) industrial cable4 core x 6.0 sqmm for high mast lights/street light maintenance all as specified and directed. |
| 57 | Supply and fixing in replacement LED street light fitting 45 Watt 230 V, surge protection 10 KVA, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.& Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 1 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed. |
| 58 | Supply & Fix inReplacement of GI Bracket made out of 40 mm dia medium grade GI tube up to 1.5 m long bend to shape 115 degree off set shape, fixed with 2 nos of suitable MS Flat clamp of size 40x5 mm with necessary nut bolts & washers and applying two coats of synthetic enameled paint over one coat of zinc oxide primer for clamp complete all as specified and directed. |
| 59 | Material and Labourfor painting ofsteel tubular pole 7.5 mtr long with one coat of aluminium paint including preparation old surface with scrapping of steel tubular poles Includingnumbering of pole no with black oil paint ,incl 2 strips of white & yellow paint , alternate upto a height of 1.2 mtrs complete all as specified and directed. |
| 60 | Material and Labour for painting of Pre-stressed concretepole 7.5 mtr long with one coat ofwhite colour weatherproof snowsum paint including numbering of pole no with black oil paint ,incl 2 strips of white & yellow paint , alternate upto a height of 1.2 mtrs complete all as specified and directed. |
| 61 | Supply and fix in replacement FRP cable looping box of size 250mm x 150mm x 100mm With connector block 4 Way , 1 Nos of MCB SP 6 Amp 10KA,etcincluding suitable Brass gland, including provision for connecting earth continuity conductor etc. all as specified and directedMake :- SINTEX / NATIONAL / NATRAJ. |
| 62 | Material and Labour for cement concrete1:3:6 type C2(using 40 mm graded stone aggregate) as in foundation filling and mass concrete for fillingcomplete all as specified and directed |
| 63 | Material and labour for lowering of LED light fiitings mounting ring 20 Mtr to 30 Mtrs heightcarefullywith help of highly skilled electrician and labours to mannually/electrically, Servicing Repair and replacement of spares of forward/reverse operation induction motor 3 phase 415 volts 2 HP capacity including winding,greasing and oiling. Servicing of forward/reverse operation Gear box including greasing and oiling, dismantling and taking chain of motor to gear box, taking down unserviceable LED Light fittings and replacement of Suitable drivers of existing capacity/ Make its serviceable,supply and replace wire rope for lift side for suitable gauges/size,replacement of timer with power contactor three phese 415 volts AC 32 Amps capacity, After repairing of LED light fittings tesiting and make serviceable of all fittings and lifting of mounting rings to existing places, After repairing of LED light fittings tesiting and make serviceable of all fittingsand lifting of mounting rings to existing places complete all as specified and directed. |
| 64 | Supply & Fix in replacement LED flood light fitting 210 Watts , 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant ,Pressure die cast aluminium housing, heat resistant toughened glass with frame, uniform distribution ,includingfixing arrangmentswith angle iron and suitable nut,bolt,washer etc on wall /on pole complete all as specified and as directed |
| 65 | Supply & Fix in replacement LED flood light fitting 120 Watts , 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant ,Pressure die cast aluminium housing, heat resistant toughened glass with frame, uniform distribution ,includingfixing arrangmentswith angle iron and suitable nut,bolt,washer etc on wall /on pole complete all as specified and as directed |