| Sl. No. | Item Description |
| 1 | Sch \"A\" Part-I B/R Portion:-Surface excavation not exceeding 30 cm deep and average 15cm deep and getting out in soft / loose soil, complete all as specified. |
| 2 | M&L for broken stone or boulders in hardcore of gauge exc 63 mm but n exc 100 mm deposited spread and levelled in layers n. exc 15 cm thick watered and rolled/rammed to a true surface complete all as specified and as directed. |
| 3 | M&L for plain Cement concrete type D-2, 1:4:8 (40mm graded crushed stone aggregate), 75mm thick as in sub base complete all as specified and as directed. |
| 4 | M&L for 60mm thick glossy finish factory made chamfered edge cement concrete rubber moulded paverblock of M-35 grade with approved colour, design & pattern with pigment as in footparth, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method usingPU mould, laid in required colour & pattern over and including 50mm thick compactedbed of fine sand, compacting and properembedding/ laying of inter locking paverblocks into the sand bedding layer throughvibratory compaction by using platevibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweeping extrasand; complete all as secified and as directed.Note-Shapes of interlocking paver block shall be triangular/Zigzag/Haxagon/or other, Colour of paver blocks & laying pattern approved by GE. |
| 5 | M&L for plaincement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in copings, kneelers, apex stones,bed plates, kerbs including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed. |
| 6 | Excavating in post holes (or similar holes) in any type of soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed. |
| 7 | M&L for PCC 1:3:6 type C-2 (using 40mm graded aggregate crushed stone aggregate) in foundation and mass concrete complete all as specified |
| 8 | S&F pre-painted galvalume aluminum zinc coating AZ-150, GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in sunshades, roof covering in required round shape as per ground requirement, cladding to wall etc fixed with self tapping screws as specified. |
| 9 | S&F pre-painted galvalume aluminum zinc coating AZ-150, GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in sunshades, roof covering, ridge in required round shape as per ground requirement, cladding to wall etc fixed with self tapping screws as specified. |
| 10 | S&F Rolled mild steel roof truss (framed), trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee, angle, channel, or flat sections) including distance pieces, cleat etc. or other connecting plates confirming to Fe-290 (Gde E165) including appling two coat of synthetic enemal paint over a coat of red oxide primer on exposed surfaces complete all as specified and as directed. |
| 11 | S&F Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes confirming to Fe-290 (Gde E-165) including appling two coat of synthetic enemal paint over a coat of red oxide primer on exposed surfaces complete all as specified and as directed. |
| 12 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft & loose soil complete all as specified and directed by Engr-in-Charge. |
| 13 | M&L for PCC 1:4:8typeD-2 using 40mm graded crushed stone aggregate as in foundation, filling or mass concrete as specified and directed |
| 14 | Returning, Filling in, including spreading, levelling, watering and well ramming in layers, not exc 25 cm in soft/loose soil complete all as specified and directed. |
| 15 | Removing excavated material n exc 50 m and depositing where directed at level n exc 1.5m above the starting point complete all as specified and directed. |
| 16 | Demolition of brick work , built in cement mortar or cement lime mortar including all quions, arches, pillars, etc including demolition of precast rcc articles and disposal of debris out of MoD land, complete all as specified and directed. |
| 17 | M&L for Brickwork with subclass \"B\" old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6)complete all as specified and directed. |
| 18 | All as per srl item No. 17 here-in-before but except brick work |
| 19 | M&L for Brickwork with subclass \"B\" old size bricks, straight or curved on plan any radius in half brick, built in CM (1:4)complete all as specified and directed. |
| 20 | M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. |
| 21 | M&L for Brickwork in half brick thick wall with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed. |
| 22 | Demolition of cement concrete (unreinforced) in ground floor and pavings n exc 15 cm thick ( above or below GL) and disposal of debris out of MoD land, complete all as specified |
| 23 | Dismantlingfloor, hearth or wall tiling including cement mortar bedding ( but not backing) removing serviceable tiles to store and rubbish off the premises and removing the debris outside from defence land complete all as specified and directed . |
| 24 | Taking down chowkhat or frames with shutters (without taking off shutters from the frames) area not exc1.5 Sqm each and removing from site. |
| 25 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof covering from sunshades etc complete all as specified and directed . |
| 26 | Dismantling timber scantlings 40sqcm and over in section, in any position as in wooden trusses in framed work of any description. |
| 27 | M&L for MS TMT bars of Grade Fe 500D, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed. |
| 28 | All as per srl item No. 27 here-in-before but 5 to 10mm dia in stirrups, spacers & binders etc complete complete all as specified and directed. |
| 29 | Use & Waste Formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. |
| 30 | Use & Waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter |
| 31 | Use & Waste Formwork to sides of pillars, posts, struts, piers, columns and stanchions |
| 32 | Use & Waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) |
| 33 | Use & Waste Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide |
| 34 | M&L for RCC,M-25 (Design Mix) using 20mm graded crushed stone aggregate for Foundations, Including rafts, footings, foundation beams; plinth beams, bases for columns, etc and Mass Concrete complete all as specified and directed. |
| 35 | M&L for RCC, M-25(Design Mix) using 20mm graded crushed stone aggregate forbeams, lintels, lintel Bands complete all as specified and directed. |
| 36 | M&L for RCC, M-25 (Design Mix) using 20mm graded crushed stone aggregate for Columns, pillars etc complete all as specified and directed. |
| 37 | M&L for RCC, M-25(Design Mix) using 20mm graded crushed stone aggregate forroof Slab supported on wall, beam and column etc complete all as specified and directed. |
| 38 | Taking down cement plaster on brick or concrete or stone walls etc including racking out joints hacking for key scrubbing down with water any description upto height 8m and disposal of debris out of MoD land, complete all as specified & directed. |
| 39 | M&L for rendering 5mmthick in CM 1:3 on ceiling surfaces, etc finished even and smooth without using extra cement, complete all as specified and directed. |
| 40 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work ,concrete surface of wall finished surface even and smooth without using extra cement complete all as specified and directed. |
| 41 | M&L for rendering 10mm thick in CM 1:6 on other than fair faces of brick work ,concrete surface of wall finished surface even and smooth without using extra cement complete all as specified and directed. |
| 42 | M&L for Preparation of newly plastered surface of wall and applying 2mm thick wall care putty and making the surface smooth and applying two coat of oil bound distemper, white or tinted shade complete all as specified. |
| 43 | M&L for Preparation of newly plastered surface of wall and applying two coat of oil bound distemper, white or tinted shade over and including a coat of primer complete all as specified. |
| 44 | M&L for preparation ofnew plastered surfaces of ceiling and applying three Coats of White Wash, complete all as specified and directed. |
| 45 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 46 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified . |
| 47 | S&F factory made Solid PVC Door Frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed. |
| 48 | S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 49 | S&F 105mm x 60mm Pressed steel frames for doors with one or more rebates made out of 1.25mm thick mild steel sheet including necessary fixing lugs, hinges, lock strike plate, etc. including tarring/black bituminous paint to unexposed surface, and two coat of synthetic enemal paint over a coat of red oxied primer, complete, as specified and directed. |
| 50 | M&L for PCC 1:3:6 nominal mix, type C-1 using 20 mm graded crushed stone aggregate as in filling of pressed steel door frames/chowkats, complete all as specified & directed. |
| 51 | S&F steel window/Ventilator factory made out of box type and shutter (double shutter) with sash bar made out ofsection using flash butt welding, hinges shall be provided to both shutters complete including all fittings including grills, glazing (glass of plain or figured type as required) , guaging (wire mesh stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples or using metal nut and bolts ) and two coat synthetic enamel paint over a coat of red oxide primer allas per drg No CEPZ/ TD/245/01 Sheet1/1 and CEPZ/TD-246/01 sheet No 1/2 & 2/2 including taking down old window complete all as specified and directed by Engr-in-Charge. |
| 52 | S&F 100mm longButt hinges, heavy weight, cold rolled mild steel, and fixed ISI marked |
| 53 | S&F aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) & fixing clips of sheet, cast and extruded section & fixing bolt & sliding bolt of extruded section ofsize 300mm longISI marked complete all as specified and directed. |
| 54 | S&F 150 mm long 10 mm dia aluminium barrel tower boltISI marked complete all as specified and directed. |
| 55 | S&F Aluminium anodized handle cast type anodised 125mm longISI marked |
| 56 | M&L for 100 mm thick Cement concrete type D-2, 1 : 4 : 8 (using 40mm graded crushed stone aggregate) as in sub floors/sub bases etc. complete all as specified and as directed. |
| 57 | M&L for 75mm thick plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in sub base even and rough finish complete all as specified and as directed. |
| 58 | M&L for Cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair including making joints at every 2.5 m and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight and complete all as specified. |
| 59 | S&F 35mm thick 2ndclass hard wood (Sal/Hollock), glazed and skeleton shutters (factory made), open rebated and prepared to receive glass or gauge etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., size of members of shutters as specified in clause 8.24 (a) of SSR Part-I, complete all as specified & directed. |
| 60 | M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in skirtings etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including laid over screed bed of 15mm thick of cement mortar 1:6 all as specified and directed. |
| 61 | M&L for Glazed coloured ceramic tiles in vertical surface 450X 350X 7-8mm thick such as skirting dado, etc set and jointed in neat cement slurry and pointed in white or colour cement to match the shed of tile including laid over 10mm thick backing layer of cement mortar (1:4) complete all as specified and as directed |
| 62 | M&L for 18-20mm thick Granite (of approveed colour) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match withshade of graniteincluding laid over 15mm thick CM 1:6 screed or backing layer complete all as specified and as directed |
| 63 | S&F Rotational moulded polyethlene water storage tanks three layers of 1000 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position with all fittings all as specified in SSR Part I including 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms) complete all as specified and as directed. |
| 64 | Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed. |
| 65 | S&F tube medium grade galvanized with all fittings and fixed to walls or laid in floors of 15mm bore including cutting chasing in walls etc if required complete all as specified and directed. |
| 66 | S&F tubes medium grade galvanized with all fittings and fixed to walls or laid in floors of 20mm bore including cutting chasing in walls etc if required complete all as specified and directed. |
| 67 | S&F 15 mm borelong body CP brass Bib taps castcopper alloy fancy type with crutch or butterfly handle (chromium plated), screwed down , high pressure for iron pipe complete all as spd & directed. |
| 68 | S&F in repair 15 mm borelong body CP brass Bib taps castcopper alloy fancy type with crutch or butterfly handle (chromium plated), screwed down , high pressure for iron pipe complete all as spd & directed. |
| 69 | S&F fancy type CP stop valve/angle valve cast copper alloy screwed down high pressure ,with crutch or butterflyhandle screwed both ends for iron pipe or for union of 15 mm borecomplete all as specified & directed |
| 70 | S&F in repair fancy type CP stop valve/angle valve cast copper alloy screwed down high pressure ,with crutch or butterflyhandle screwed both ends for iron pipe or for union of 15 mm borecomplete all as specified & directed |
| 71 | S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed, Bore dia of pipe 20 mm |
| 72 | S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed, Bore dia of pipe 15 mm |
| 73 | S&FVitreous china wash basin,counter sunk of size 550 x 400 mm, including cutting for and pinning in ends of brackets or erecting stand including 32 mm bore CP waste pipe long screw thread and 32 mm diaflexible waste pipe incl fixing of taps including RCC slab and TMT bars to facilitate complete all as spd and directed. |
| 74 | S&Fin repair Vitreous china wash basin,counter sunk of size 550 x 400 mm, including cutting for and pinning in ends of brackets or erecting stand including 32 mm bore CP waste pipe long screw thread and 32 mm diaflexible waste pipe incl fixing of taps including RCC slab and TMT bars to facilitate complete all as spd and directed. |
| 75 | S&F Vitreous China Urinal, Half stall type, white including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, , flush pipe, grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) fixed incl supply and fixing ofCP coupling, waste pipe and cp brass spreder all necessary fittings, complete all as specified and directed. |
| 76 | S&F in repair Vitreous China Urinal, Half stall type, white including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, , flush pipe, grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) fixed incl supply and fixing ofCP coupling, waste pipe and cp brass spreder all necessary fittings, complete all as specified and directed. |
| 77 | S&F CP Pillar taps fancy type 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot\" or `Cold\" with long screwed shanks & fly-nuts, screwed for iron pipe complete all as specified and directed. |
| 78 | S&F vitreous china water closet squatting pan ‘Orrissa pattern” size 580x440mm white with integral foot rests including provision of of cement concrete bedding, connection to flush pipe and making good the disturbed portion of floor to match with the existing surface jointing to PVC/CI bend and flush pipe complete all as specified and as directed by Engr-in-Charge. |
| 79 | S&F in repair vitreous china water closet squatting pan ‘Orrissa pattern” size 580x440mm white with integral foot rests including provision of of cement concrete bedding, connection to flush pipe and making good the disturbed portion of floor to match with the existing surface jointing to PVC/CI bend and flush pipe complete all as specified and as directed by Engr-in-Charge. |
| 80 | S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. complete, including Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminized hinging device complete all as specified and directed. |
| 81 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. complete, including Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminized hinging device complete all as specified and directed. |
| 82 | S&F10 ltrs capacity PVC valve less, syphonic action type, flushing cistern, low level, white, with intel, ball valve, float and handle including brackets ,fush pipe of polyethylene of low or high density or PVC 32 mm dia complete all as specified. |
| 83 | S&F in repair 10 ltrs capacity PVC valve less, syphonic action type, flushing cistern, low level, white, with intel, ball valve, float and handle including brackets ,fush pipe of polyethylene of low or high density or PVC 32 mm dia complete all as specified. |
| 84 | S&F 15 mm dia PVC connection of 450mm long, PTMT nuts. |
| 85 | S&F in repair 15 mm dia PVC connection of 450mm long, PTMT nuts. |
| 86 | S&F beveled edge mirror of any size of selected quality glass not less than 5.5 mm thick with edges rounded or beveled , decorative and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 87 | S&F brass CP Soap Dish or Soap Holder Dish round/oval shaped for Bathroom with fixing arrangement complete all as specified and as directed. |
| 88 | S&F in repairbrass CP Soap Dish or Soap Holder Dish round/oval shaped for Bathroom with fixing arrangement complete all as specified and as directed. |
| 89 | S&F 75mm bore cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 with CP grating complete all as specified & directed. |
| 90 | M&L for Cast iron soil, waste and vent pipes 100mm dia in any length with or without ears, with cement joints, fixed on wall complete all as specified and as directed. |
| 91 | S&F 100mm dia cast iron bend with ovel access door and jointed with neat cement paste complete all as specified and as directed. |
| 92 | S&F 75mm dia cast iron bend with ovel access door and jointed with neat cement paste complete all as specified and as directed. |
| 93 | M&L for Cast iron soil, waste and vent pipes 75mm dia in any length with or without ears, with cement joints, laid on tranches or fixed on wall complete all as specified and as directed. |
| 94 | S&F 75mm cast iron cowl. |
| 95 | S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof |
| 96 | M&L for APP modified roof treatment over existing non-accessible RCC roof slab/chajjah/canopy/ parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and as directed.(a)cleaning the top surface of RCC roofing properly with water.(b) 15 mm thick screed bed in CM 1:4 including mixed with water proofing admixture as per manufacturer\"s instructions(c) Applying oil bound bitumen primer @ 0.3 ltr/sqm manufacture by the same agency as that of APP with a density 0.87-0.89 kg/ltr at 25 degrees centigrade on prepared surface.(d)Laying of membrane not less than 3 mm thick APP modified water proofing membrane weighing not less than 3 kg/Sqm reinforced with non-woven polyester fibre weight not less than 150 Gms/Sqm using butane by torch application with 10cm side laps and 15 cm end lap complete(e) APP membrane shall laid using butane torch by torch application with minimum 10 cm side over lap and 15 cm end lap(f)Top of membrane shall be provide with solar reflective bituminous aluminium paint @ 0.1 Kg/sqm as prescribed by manufacturer of membrane.(g) APP membrane shall be stick inside parapet where available by chase cutting and sealed with PCC 1:2:4 type B-0. |
| 97 | S&F in repair Brass chromium plated Tubular towel ring, 20mm dia, complete all as specified and as directed. |
| 98 | S&F 1200mmx600mm, 5.5mm thick bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washerscomplete all as specified and directed by Engr-in-Charge. |
| 99 | S&F in repair PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors all as specified and directed. |
| 100 | S&F in repair PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors all as specified and directed. |
| 101 | S&F PVC (SWR) bends any radius 110mm dia all as specified and directed. |
| 102 | S & F in repair 75mm PVC floor trap, ISI marked withcp grating with/without waste pipe hole incl jointing to waste pipe fixed with solventcement complete all as specified and as directed. |
| 103 | Sch \"A\" Part-I E/M Portion:-Taking down old unserviceablecopper/aluminium point wiring (light, fan, socket , power socket and bulk head fittings) on surface wiring on wooden batten/casings & caping complete, including fixture and fittings such as switches, ceiling roses,pendents holder, regulators andsocketsby unscrewing carefully from boards etcand making good disturbed surfaces of walls, as per existing finishescomplete all as spd and directed. |
| 104 | M&L for point wiring for one light/one fan controlled by one switch with 1.5 Sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H 1100 volte grade cable, withand including PVC rigid concealed conduit (ISI marked) with all fittings including sheet steel/CI terminal box of adequate size including 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable as earth continuity conductor connected to comman earth dolly, complete all as specified and directed.Note:- 1. connection of cable with MCBs/switch sockets shall be done through proper size copper /brass thimbles.2.Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible. 3.Proper colour coud will be used for wiring as per the electrical rule and as directed. |
| 105 | All as per Srl item No 104 here-in-before but for 5 pin 5 amps socket outlet on the independent board controlled by one switch SP, one way 5 Amp, 240 Volts. complete all as specified and directed. |
| 106 | All as per Srl item No 104 here-in-before but for 5 pin 5 amps socket outlet on the sameboard with other switch complete all as specified and directed. |
| 107 | M&L for point wiring with 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable with in and including PVC concealed conduit heavy duty with all fittings including anodise pressed steel sunken box with bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface tomatch with the existingsurface complete all as specified and directed. |
| 108 | S&F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed. |
| 109 | S&F switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed. |
| 110 | S&F socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed. |
| 111 | S&F socket outlet 2 in 1, 5 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed. |
| 112 | S&F lamp holder/batton holder/angle holder insulated body with bakelite back plate suitable for fittings complete all as specifiedand directed. |
| 113 | S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed. |
| 114 | S&F ceiling fanregulator electronicsocket type 5 stage speed variation ISI marked complete all as specifiedanddirected. |
| 115 | S&F CFLs with LEDLamp, B22type ,12 watt,complete all as specified and directed. |
| 116 | S&F sleek LED Battenlight fitting, 1x20 W including LED tube 4 feet long of same make having ballast , bipin holder, connector block etc. complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core complete all as required at site or directed. |
| 117 | S&F in repairenergy saving , surface mounted, bulk head LED luminaire 10 Watt with PDC aluminium housing and polycorbonate diffuser with IP 66 protection including connecting with suitable size copper wire all as specified. |
| 118 | S&F, testing and hangging the ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and connecting with suitable size copper conductor and including writing of MES No. with black enamelled paint complete all as specified and as directed. |
| 119 | M&L for providing/ cutting the round/ square hole of required size in wall finishing thedistrubed surfaces as per existing finishes complete all as spd and supply and fixing propeller PVC type AC ventilating fans, Single phase, 230 volts 250 mm sweep complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated copper cable of suitable size from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge. |
| 120 | S&F sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases in wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed. |
| 121 | S&F MCB SP 240 volts any rating from 6 to 40 amps, \"B\" cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. |
| 122 | S&F MCB SPN 240 volts any rating from 6 to 40 amps,\"B\" cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. |
| 123 | S&F bldg secuirty light fitting energy saving high efficiency LED street light fitting 25 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 25 mm dia bent to shape having length not less than 0.9 mtr fixing with clamp etc and making connections using suitable size copper cable from ceilling rose/ PVC connector to light fittings or as directed by Engr-in-chrage. |
| 124 | Supply, laying and testing LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sq. mm 2 core complete all as specified |
| 125 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for laying of cable ,pole foundation,stay,laying of pipe etc complete all as specified and directed. |
| 126 | M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified(Note:-Punned thickness shall be measured and paid) |
| 127 | M&L for brick covering equal to length of bricks as mechanical protection to cable with well burnet sub class ‘B’ bricks laid as directed by the Engr-in-Charge. |
| 128 | Returning filling in, including spreading ,leveling ,watering and well ramming in layers not exc 25 cm complete all as specified. |
| 129 | Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 130 | S&F GI tubing light grade 50 mm bore for cable protection laid in trenches in road crossing or fixed to wall/Pole including fittings /clamp complete all as specified and directed. |
| 131 | S&F GI tubing medium grade 25 mm bore including all fittings such as bend, clamps, nuts bolts and washers and laid in tranches, floor, along withwall/ceiling etc complete all as specified and as directed. |
| 132 | S&F Gun-metal, globe or gate valves 25mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed |
| 133 | M&L for cutting/drilling of 100mm GI pipe for connection of 25mm GI pipe including all required fitting and accessories complete all as specified and as directed. |
| 134 | M&L for earthing complete with galvanised steel earth plate electrode , 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level)withtop edge of the platenot less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15 mm bore light grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal ,salt packed around the earth plate and precastPCC 1:2:4 (Nominal mix ) reinforced with XPM having weight not less than 4 kg /sqm including suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover including earth workin any type of soil , removal of surplus soil to a distancen.exc 50m and connecting , testing on completion completeall as shown on electricplate No 03 of SSR -2009 Part I and connecting to existing earth test point complete all as specified and directed or including testing on completion.(Note: Excavation and earth work is deemed to be included in the rates quoted). |
| 135 | S&F in repair sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 6 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases in wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed. |
| 136 | M & L for providing/ cutting the round/ square hole of required size in wall finishing thedistrubed surfaces as per existing finishes complete all as spd and supply and fixing MS ventilating fansSingle phase, 230 volts 300 mm or 12” H.D EX Fan (900 RPM) complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated copper cable suitable size from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge. |
| 137 | Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs12,557.00 and any other reduction if any from quoted amount. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy