| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling, including cement mortar bedding (but not backing), removing serviceable tiles to store and removing rubbish off the premises, complete all as specified and directed. |
| 2 | M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, laid in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of the tiles, including 15 mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 3 | M&L for coloured glazed ceramic tiles in vertical surfaces, each tile exceeding 0.18 sqm in area, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, with and including 10 mm thick rendering (backing coat) in CM 1:4 and triangular filleting at top of skirting, complete all as specified and directed. |
| 4 | M&L for premium quality vitrified ceramic tiles, 9 to 10 mm thick (square/rectangular), polished, each tile exceeding 0.36 sqm in area, laid in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 20 mm thick screed bed in CM 1:4, complete all as specified and directed.Note: Sample and colour/finish shall be approved by the Engineer-in-Charge from the latest catalogue. |
| 5 | Ditto as per Item No. 4.00 above, but in skirting / vertical surfaces, including 10 mm thick backing coat in CM 1:4, complete all as specified and directed. |
| 6 | Demolition of plain cement concrete (PCC) of any description and in any position, not otherwise specifically provided for, complete all as specified and directed by the Engineer-in-Charge. |
| 7 | M&L for applying a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm, including cleaning the surface prior to application, complete all as specified and directed. |
| 8 | M&L forPlain cement concrete type F2 (1:7:12) using 40 mm graded stone aggregate as in foundation, filling, mass concrete, etc., complete all as specified and directed. |
| 9 | M&L for PCC 1:3:6, Type C-2, 100 mm thick, as in sub-base for sunken slab/floor, mixed with water-proofing compound (WPC) @ 3% by weight of cement, finished even and smooth without using extra cement, complete all as specified and directed.Note: WPC shall be measured and paid separately. |
| 10 | M&L for 20 mm thick cement screed in cement mortar 1:3, mixed with liquid water-proofing compound FOSROC Complast 421 IC @ 130 ml per bag of cement, including a bonding coat of FOSROC Nitobond AR in cement slurry for sunken slab/floor treatment, complete all as specified and directed.Note: Water-proofing compound shall be measured separately. |
| 11 | Dismantling stone slabs and tiles of any description or thickness, laid, bedded and pointed in any mortar in floors, aprons, etc., including removal of serviceable materials to store and rubbish off the premises, complete all as specified and directed. |
| 12 | M&L for 20 mm thick granite (any type), table-rubbed and polished, as in steps, jambs, pillars, window-cills, cooking platforms, working tables and the like, laid over 20 mm thick screed bed in CM 1:4, including pointing in white cement (1:2) with marble dust and pigment to match the shade of granite, complete all as specified and directed. |
| 13 | M&L for 20 mm thick machine-cut mirror polished granite for skirting/vertical surfaces such as jambs, risers, pillars, etc., set in grey cement slurry and pointed in white cement with pigment to match the shade of granite, including grinding, polishing and 10 mm thick backing coat in CM 1:3, complete all as specified and directed.Note: Colour/shade of granite shall be approved by the GE/Engineer-in-Charge. |
| 14 | M&L for 20 mm thick granite (any type), table-rubbed and polished, as in steps, jambs, pillars, window-cills, cooking platforms and the like, laid in cement mortar 1:4, including pointing in white cement (1:2) with marble dust and pigment to match the shade of granite, complete all as specified and directed. |
| 15 | M&L for bees-wax polishing over marble, granite, Kota stone, stone work or mosaic tiles wherever required to obtain a high-gloss finish, complete all as specified and directed. |
| 16 | M&L for chequered cement concrete tiles 30 cm × 30 cm × 25 mm thick, set, jointed and pointed in neat cement slurry in floors using grey cement with pigment, including 20 mm thick screed bed in CM 1:6, complete all as specified and directed. |
| 17 | M&L for machine-pressed precast concrete interlocking paver blocks of 60 mm thickness, M-35 grade, of any shape and size, manufactured with grey cement and pigment, conforming to IS 15658:2006, laid over and including 50 mm thick sand cushioning, set and jointed in sand, complete all as specified and directed by the Engineer-in-Charge. |
| 18 | M&L for 22–25 mm thick machine-cut Kota stone slab, as in floors, steps and landings, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of the slab, including cutting, rubbing and polishing, and including 20 mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 19 | Dismantling wall and ceiling boards (fibre, pulp, insulation), insulation boards, false ceiling, wall panelling and partition boards, bonded wool, blanket slab, including aluminium grid framework, complete all as specified and directed. |
| 20 | M&L for anodised aluminium snap grid framework for false ceiling, grid size 605 × 605 mm, including 2 mm dia GI hangers (up to 1200 mm long) fixed to roof slab with GI ceiling cleats made from 40 × 3 mm flat, 60 mm long, and fixed with 12.5 mm dia × 40 mm long expansion fasteners, including fibre-cement board / cement board tiles of size 600 × 600 mm, complete all as specified and directed. |
| 21 | M&L for POP false ceiling using 600 × 900 × 12 mm thick plaster-of-Paris gypsum-bonded decorative sheets, fixed to 22-gauge GI channel grid framework consisting of:(a) Main joists: 50 × 25 mm at 750 mm centres(b) Secondary joists: 75 × 20 mm at 900 mm centres(c) Suspended from roof members using 25 × 25 × 2 mm GI angles and fasteners @ 1.2 m c/cIncluding decorative design/pattern and provision for concealed light fittings, complete all as specified and directed by the Engineer-in-Charge. |
| 22 | Taking down chowkats or frames exceeding 1.5 sqm but not exceeding 4 sqm each, with shutters without taking shutters off the frame, complete all as specified and directed. |
| 23 | All as per Item No. 22.00 above but for chowkats or frames not exceeding 1.5 sqm each, complete all as specified and directed. |
| 24 | Supply & fixing inpowder coated aluminiumsections for partitions, windows, ventilators and doors including fabrication of frame/shutters and fixing to walls/floors with necessary lugs, cleats etc including all accessories such asglazing clips, handles, tower bolts, rollers rubber beadings for fixing glass panes in frame including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required complete all as specifiedNote: - (i) Glass panes will be measured & paid separately. (ii)The rate quoted shall be inclusive of neoprene beading, glazing clips, screws, etc. as requiredbut shall not be measured for arriving of weight.(iii) Minimum thickness of powder coating shall be 25 micron. (iv) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel around contacting surface of aluminium work with matching existing area.(v)The size of aluminium sections shall be as perHQ CE(N) MZ TD drawing No TD/2021/01 to 05 |
| 25 | S&F 4 mm thick frosted (one-side) glass sheet, ordinary quality, in panes not exceeding 0.5 sqm each, glazed with putty/Aluminium beading as required and fixed to aluminium windows/ventilators in repairs, complete all as specified and directed. |
| 26 | S&F 4 mm thick frosted (one-side) glass sheet, ordinary quality, in panes exceeding 0.5 sqm each, glazed with putty/Aluminium beading as required and fixed to aluminium windows/ventilators in repairs, complete all as specified and directed. |
| 27 | M&L for 4 mm thick plain glass sheets, ordinary quality, in panes not exceeding 0.5 sqm each, fixed with rubber beading for aluminium windows/doors, complete all as specified and directed. |
| 28 | M&L for 4 mm thick plain glass sheets, ordinary quality, in panes exceeding 0.5 sqm, fixed with rubber beading for aluminium windows/doors, complete all as specified and directed. |
| 29 | S&F in repair aluminium anodised grill, Deco Grill DG-103, 7.5 mm thick (Make: Elesar Focchi Ltd or equivalent), fixed using suitable ‘F’ section No. 8584 (15.30 × 23.40 × 1.40 mm), fabricated and riveted to aluminium windows, complete all as specified and directed by the Engineer-in-Charge. |
| 30 | S&F in repairs 12 mm thick pre-laminated MDF (Medium Density Fibre) board, both sides decorative laminate, interior grade, fixed to aluminium/wooden framework, complete all as specified and directed. |
| 31 | S&F stainless steel wire cloth, 0.36 mm nominal wire diameter and average aperture 1.40 mm, complete all as specified and directed. |
| 32 | S&F in repairs 4 mm thick bakelite sheet, decorative type, laminated on both sides, fixed as required, complete all as specified and directed. |
| 33 | Taking down cement plaster or cement-lime plaster on brick or stone walls, including raking out joints, hacking for key, and scrubbing down with water, complete all as specified and directed. |
| 34 | M&L for 15 mm thick rendering using ready-mixed cement-based plaster, having minimum composition equivalent to cement:sand 1:4, manufactured using fully treated dry, well-graded natural sand, suitable for internal and external plastering, with low rebound loss and reduced water demand; mechanically mixed with water in metal trays to achieve proper workability and consistency as per manufacturer’s specifications, applied over concrete/masonry surfaces, including erection and dismantling of scaffolding for work up to 1 to 4 storey heights, complete all as specified and directed. |
| 35 | M&L for 10 mm thick rendering using ready-mixed cement-based plaster, having minimum composition equivalent to cement : sand (1:4), manufactured with fully treated dry, well-graded natural sand, suitable for internal/external plastering, with low rebound loss and reduced curing water demand; mechanically mixed with water in a metallic tray to achieve proper workability and consistency as per manufacturer’s specifications; applied over interior wall/ceiling and concrete/masonry surfaces, including scaffolding where required, complete all as specified and directed. |
| 36 | M&L for one coat of Hydrolock, applied by brush without dilution, as a waterproofing coat over prepared finished surfaces, complete all as specified and directed by the Engineer-in-Charge. |
| 37 | M&L for preparation of new plastered wall surfaces of any description, and applying two coats of acrylic (antifungal) exterior-grade paint @ 1.67 litres per 10 sqm, over and including one coat of primer @ 2.20 kg per 10 sqm, on walls/roofs, including erection and dismantling of scaffolding for work up to 1 to 4 storeys, complete all as specified and directed. |
| 38 | M&L for preparation of new plastered surfaces of walls, and applying two coats of oil-bound distemper over a coat of alkali-resistant primer, including necessary scaffolding where required, complete all as specified and directed. |
| 39 | M&L for 3 mm thick wall-care putty on plastered wall surfaces, including sanding, cleaning, and surface preparation before applying paint, complete all as specified and directed by the Engineer-in-Charge. |
| 40 | M&L for preparation of new plastered ceiling surfaces and applying three coats of whitewash, including necessary scaffolding, complete all as specified and directed by the Engineer-in-Charge. |
| 41 | M&L for preparation of old wall surfaces of any description, and applying one coat of acrylic (antifungal) exterior-grade paint @ 1.67 litres per 10 sqm, over and including one coat of primer @ 2.20 kg per 10 sqm, on walls/roofs, including erection and dismantling of scaffolding for work up to 1 to 4 storeys, complete all as specified and directed. |
| 42 | M&L for preparation of old wall surfaces of any description, and applying two coats of acrylic (antifungal) exterior-grade paint @ 1.67 litres per 10 sqm, over and including one coat of primer @ 2.20 kg per 10 sqm, on walls/roofs, including erection and dismantling of scaffolding for work up to 1 to 4 storeys, complete all as specified and directed. |
| 43 | M&L for preparation of old ceiling surfaces, and applying one coat of oil-bound distemper, including necessary scaffolding, complete all as specified and directed by the Engineer-in-Charge. |
| 44 | M&L for preparation of old wall surfaces of any description and applying one coat of oil-bound distemper on walls/roofs, including necessary scaffolding up to mezzanine floor height, complete all as specified and directed. |
| 45 | Taking down PVC wastage and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, complete all as specified and as directed |
| 46 | Supply & Fixing in repairs 160mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracketsuitable for 110mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified. |
| 47 | S&F 160mm dia bore PVC (SWR) bends any radius complete all as specified and as directed |
| 48 | Supply & Fixing 110mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracketsuitable for 110mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified. |
| 49 | Supply & Fixing 75mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracketsuitable for 75 mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified. |
| 50 | S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and as directed |
| 51 | S&F 75 mm bore PVC (SWR) bends any radius complete all as specified and as directed |
| 52 | S&F in repairs 75 mm dia cast iron nahani trap, with grating, including jointing to waste pipe and fixing in cement concrete type B-1 (1:2:4), complete all as specified and directed. |
| 53 | S&F in repairs 100 mm dia cast iron nahani trap, with grating, including jointing to waste pipe and fixing in cement concrete type B-1 (1:2:4), complete all as specified and directed. |
| 54 | M&L for taking up or taking down existing 15 mm bore GI water tubing, including cleaning for refixing or removal to store, complete all as specified and directed. |
| 55 | M&L for taking up or taking down existing 20 mm bore GI water tubing, including cleaning for refixing or removal to store, complete all as specified and directed. |
| 56 | S&F 15 mm bore GI tubing, medium grade, with all fittings such as tees, bends, elbows, etc., fixed to walls or ceilings with saddles/spacers, complete all as specified and directed. |
| 57 | S&F 20 mm bore GI tubing, medium grade, with all fittings such as tees, bends, elbows, etc., fixed to walls or ceilings with saddles/spacers, complete all as specified and directed. |
| 58 | S&F in repairs vitreous china urinal, half-stall type, including bedding in cement mortar (1:2), securing urinal to plugs with 60 mm brass screws, pointing around urinal in cement mortar; including automatic flushing arrangement, brackets, flush pipes, inlet and outlet connections, complete all as specified and directed . |
| 59 | S&F in repairs 32 mm dia PVC waste pipe for wash hand basins and urinals, fixed in position, complete all as specified and directed. |
| 60 | S&F in repairs fancy type bib tap, chromium-plated cast copper alloy, 15 mm bore, with crutch or butterfly handle, screwed down, fixed in position, complete all as specified and directed. |
| 61 | S&F in repairs wash hand basin, vitreous china, flat-back type, size 550 × 400 mm, including brackets for fixing, chromium-plated brass waste with long screwed shanks and fly nuts (32 mm), and bottle trap; complete all as specified and directed. |
| 62 | S&F fancy type pillartaps castcopper alloywith lift type lever head chromiumplatedscreweddownhigh pressure withletteredhotorcoldwithlongscrewedshanksandfly nutsscrewedforiron pipeandfixedin repairs of 15 mmborepipe etc complete all as specified and directed. |
| 63 | S&F in repairs vitreous china squatting type water closet (“Orissa” pattern), size 580 × 440 mm, white, with integral foot rests and ‘P’ trap, excluding flushing cistern, but including PVC flush pipe and lime concrete bedding, complete all as specified and directed. |
| 64 | S&F in repairs vitreous china wash-down type pedestal water closet pan, white, (excluding flushing cistern and flush pipe), fixed in position, complete all as specified and directed. |
| 65 | S&F in repairs plastic seat cover for pedestal type WC pan, black or white, closed pattern with flat bottom and cover, complete with mild steel chromium-plated or aluminised hinging device, all as specified and directed. |
| 66 | S&F in repairs 10-litre capacity PVC valveless syphonic action type flushing cistern, high or low level, white, complete with inlet ball valve, float, handle and brackets (exclusive of supporting brackets where required), complete all as specified and directed. |
| 67 | S&F in repairs brass chromium-plated towel rail, 20 mm dia, D-type, 60 cm long between flanges, fixed in position, complete all as specified. |
| 68 | S&F in repairs brass CP shower rose 125mm size complete all as specified and directed. |
| 69 | S&F in repairs stainless steel sink with drainage board, 1 mm thick, for kitchen or laboratory, with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or fixing on cantilever brackets; including union connection to waste pipe; overall size 915 × 460 mm, bowl size 410 × 330 × 160 mm, complete all as specified and directed. |
| 70 | S&F in repairs 15 mm dia PVC connection pipe, 450 mm long, complete all as specified and directed. |
| 71 | M&L for 600 × 450 mm bevelled edge mirror, 5 mm thick selected quality glass, mounted on 6 mm thick AC building board, fixed to wall with wooden plugs, chromium-plated brass screws and cup washers, complete all as specified and directed and fixed in repairs. |
| 72 | S&F solid PVC door frame, size 50 × 47 mm, made out of 5 mm wood-grain printed PVC sheet reinforced with MS square tube, edges finished to match printed surface, complete all as specified. |
| 73 | S&F factory-made solid panel PVC door shutter, 30 mm thick, comprising MS tube frame for top and bottom rails; frame covered with heat-moulded plain-colour PVC ‘C’ channel; PVC sheet strip (20 mm) stuck inside with solvent cement for stiles; plain-colour PVC sheet for top and bottom rails; plain-colour PVC sheet panelling fitted within the MS frame, welded/sealed to stiles and rails with suitable PVC bedding; all joints made with solvent cement; supplied and fixed in frame at site, complete all as specified and directed. |
| 74 | S&F 75 mm butt hinges, stainless steel hinge pin, bright-polished, type B-11, complete all as specified and directed. |
| 75 | S&F 150 mm long aluminium anodised barrel tower bolt, extruded section, fixed in position, complete all as specified and directed. |
| 76 | S&F in repairs 150 mm long aluminium anodised barrel tower bolt, extruded section, fixed in position, complete all as specified and directed. |
| 77 | S&F 300mm long aluminium alloy, anodized sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet cost of extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed. |
| 78 | S&F in repairs 300 mm long aluminium alloy anodised sliding door bolt, with hasp and staple (bolt type), including fixing clips of sheet or extruded sections, fixing bolts and sliding bolt of extruded or cast aluminium alloy, complete all as specified and directed. |
| 79 | S&F 140 mm long floor door stopper, aluminium alloy body and tongue, anodised, with hard-drawn steel spring, fixed in floor, complete all as specified and directed. |
| 80 | S&F 150 mm long extruded aluminium alloy handles, cast type, fixed in position, complete all as specified and directed. |
| 81 | S&F in repairs 150 mm long extruded aluminium alloy handles, cast type, fixed in position, complete all as specified and directed. |
| 82 | S&F 100 mm long extruded aluminium alloy handles, cast type, fixed in position, complete all as specified and directed. |
| 83 | S&F in repairs 100 mm long extruded aluminium alloy handles, cast type, fixed in position, complete all as specified and directed. |
| 84 | Dismantling wrought iron or mild steel work of any description, not otherwise specifically provided for, complete all as specified and directed. |
| 85 | Supply & fixing of Mild Steel Framed work such as grills, gratings, sunshades, with ends of bars shouldered and/or riveted or welded, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balustrades; walkways; railings; framework of water tanks and similar work, conforming to Fe-410-0 or Fe-310-0, complete all as specified and directed. |
| 86 | Material & Labour for rolled MS in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections)including distance pieces, cleats etc.conforming to Fe 410 W (Grade E-250) quality B completeall asspecified and directed by Engineer-in-Charge. |
| 87 | Supply and fix rolled mild steel section of Grade Fe-410-W (Gde-E-250), quality A, such as plates (plain or chequered), channels as in manhole covers etc., square cut or notched (ordinary or countersunk) for forming holes, without any attachment, complete all as specified. |
| 88 | M&L for preparing new or previously untreated steel surfaces, of any description over 10 cm width or girth, and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed. |
| 89 | M&L for preparation of old painted steel surfaces, of any description over 10 cm width or girth, and applying one coat of synthetic enamel paint, complete all as specified and directed by the Engineer-in-Charge. |
| 90 | S&F expanded metal, weight not exceeding 4.00 kg/sqm, bent to required shape and fixed using annealed mild steel wire of dia not less than 0.90 mm or fixed with galvanised steel staples to wood or steel members, complete all as specified and directed. |
| 91 | Demolition of stone/brick masonry built in cement mortar, including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and directed. |
| 92 | M&L brickwork with sub-class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius, built in CM 1:6, complete all as specified and directed. |
| 93 | M&L for double action floor spring, hydraulically regulated, made of minimum 1.25 mm thick aluminium alloy sheet foundation box, stainless steel cover, governing pivot made of brass, other parts mild steel heavy-duty, and fixed all as per manufacturer’s instructions, complete all as specified and directed. |
| 94 | S&F solar control film, 25 micron, reflective type, stuck to glass panes as per manufacturer’s instructions, complete all as specified and directed. |
| 95 | S&F push-type taps for urinals, cast copper alloy with crutch or butterfly handle, screwed down, suitable for 15 mm dia iron pipe or brass ferrule, fixed in repairs, complete all as specified and directed. |
| 96 | S&F in repair PVC tube health faucet (ABS body), mild steel chromium plated, suitable for 15 mm dia pipe, with 1.25 metre long flexible tube and ABS wall hook, including making necessary connections and fixing in position, complete all as specified and directed. |
| 97 | S & F Toughened glass, 10 mm thick, as in hinged doors, partition panels, automatic doors and similar work including cutting to shape and drilling holes as required, complete all as specified and directed. |
| 98 | Dismantling plain or corrugated steel sheeting, any gauge or thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed. |
| 99 | S&F pre-painted hot- dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.5 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and as directed. |
| 100 | S&F pre-painted hot- dip aluminium-zinc alloy metallic coated plain steel sheet, corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.5 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and as directed. |
| 101 | M&L for 1.5 mm thick galvanised steel sheet used as in fascia of roof, window chhajja and valley gutters, fixed with rivets or other suitable arrangements over MS brackets in any required shape/design and profile with desired slope, including cutting holes and forming to shape, complete all as specified and directed by Engr-in-Charge.Note: MS work shall be measured and paid separately. |
| 102 | S&F 2 mm thick fibre-glass reinforced translucent plain/corrugated sheeting, with two-corrugation side lap, fixed with L-type, J-type or cranked hook in lieu of screws, as in roof or wall cladding, complete all as specified and directed. |
| 103 | S&F in repairs roller venitian blinds, made out of standard cloth of approved texture, with necessary accessories, complete all as specified and directed. |
| 104 | S&F mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood, including mirror brackets, complete all as specified and directed. |
| 105 | S&F solid PVC wall lining/panelling using solid or hollow sections, consisting of 5 mm thick plain colour PVC sheet, fixed using solvent cement on PVC frame at site, all as per specifications and drawings, complete all as specified and directed. |
| 106 | S&F 5 mm thick PVC sheet fillet, 35 mm wide, for wall panelling, including fixing to wall to form PVC frame, all as per specifications and drawings, complete all as specified and directed. |
| 107 | M&L for 100 mm thick PCC type D-2 (1:4:8) using 40 mm graded stone aggregate, as in sub-base, complete all as specified and directed. |
| 108 | Removing debris to a distance exceeding 1.50 km but not exceeding 20 km, and depositing where directed outside MD land, complete all as specified and directed. |
| 109 | M&L for complete removal of existing treatment on wall surfaces, including sanding to obtain an even and smooth finish, applying one coat of wall primer, and finally applying one coat of oil-bound distemper of approved tint, including necessary scaffolding up to mezzanine floor, complete all as specified and directed. |
| 110 | M&L for complete removal of existing treatment on wall surfaces and applying andsanding the surfaces till even and smooth finish and applying one coat of wall primer and finally applying two coats of oil bound distemper of approval tint including necessary scaffolding upto mezzanine floor complete. |
| 111 | M&L for preparation of old decorated wall surfaces of any description, including sanding the previously painted surface, and applying one coat of plastic emulsion paint, complete all as specified and directed. |
| 112 | M&L for preparation of old decorated wall surfaces of any description, including sanding the painted surface, and applying two coats of plastic emulsion paint, complete all as specified and directed. |
| 113 | M&L for metallic plain painting on wall/ceiling surfaces in approved design and pattern, all as per manufacturer’s instructions. |
| 114 | M&L for preparation of wall surfaces and applying two coats of chemical waterproofing treatment (such as Raincoat of Pidilite or equivalent) on walls, chajjas, terrace and parapet wall junctions (e.g., Flexcoat, Beckcoat Exshield or equivalent), including filling cracks in wall/concrete with Crack-X of Pidilite or equivalent, all as per manufacturer’s instructions, complete all as specified and directed. |
| 115 | M&L for applying 1mm thick one coat wall care putty on walls / ceilings etccomplete all as specified and as directed. |
| 116 | M&L for applying 2mm thick one coat wall care putty on walls / ceilings etccomplete all as specified and as directed. |
| 117 | M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth, and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 118 | M&L for preparation of old plastered or unplastered decorated wall surfaces, including cornices, pilasters, stopping of distempered/painted surfaces, and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 119 | M&L for French polishing on wooden surfaces of any description, width or girth, including cleaning and surface preparation, applying one coat of wood filler, and applying one or more coats of French polish, complete all as specified and directed. |
| 120 | M&L for varnish polishing on old wooden surfaces of any description, width or girth, including cleaning, surface preparation, applying one coat of wood filler, and applying one or more coats of varnish using air compressor machine, complete all as specified and directed. |
| 121 | M&L for rendering 15 mm thick on fair faces of brick or concrete surfaces in CM 1:6, finished even and smooth without using extra cement, including erection and dismantling of scaffolding to execute work up to 1 to 4 storey height, complete with safety precautions and as specified and directed. |
| 122 | M&L for rendering 10 mm thick in CM 1:3 on ceiling surfaces, finished even and fair (ceiling height included up to top slab of building), complete all as specified and directed. |
| 123 | M&L for rendering 15 mm thick on external wall surfaces in CM 1:4, mixed with water proofing compound @ 3% by weight of cement, including erection and dismantling of scaffolding for working up to 1 to 4 storeys, complete all as specified and directed. |
| 124 | Supply only waterproofing compound @ 3% by weight of cement complete all as specified and directed. |
| 125 | M&L for preparing new plastered wall surfaces and applying two coats of oil-bound distemper over a coat of alkali-resistant primer and 3 mm thick wall care putty, including necessary scaffolding complete all as specified and directed. |
| 126 | M&L for preparation of new plastered ceiling surfaces and applying three coats of whitewash, including necessary scaffolding complete all as specified and directed by Engr-in-Charge. |
| 127 | M&L for preparation of floor surfaces such as PCC, interlocking tiles, chequered tiles, any floor tiles/CGI sheet/Mangalore tiles, and applying one coat of Indigo floor paint, including necessary scaffolding and tug arrangement complete all as specified and directed. |
| 128 | M&L for preparation of floor surfaces such as PCC, interlocking tiles, chequered tiles, any floor tiles/over CGI sheet, and applying two coats of Indigo floor paint, including necessary scaffolding and tug arrangement complete all as specified and directed. |
| 129 | M&L for cleaning plastered surfaces by removing loose particles, dirt, vegetation etc. Defining cracks with a sharp-edged tool, cleaning and moistening, and providing and applying acrylic polymeric non-shrink crack filler “PAINTEX-4” for cracks up to 5 mm–12 mm width, including finishing at all heights and levels. After 24 hours, inspecting and refilling if required due to auto-suction complete all as specified and directed. |
| 130 | Material & labour for treating existing cracked wall and column surfaces by scrubbing to remove dust, dirt, grime, oil etc., washing with jet water, applying one coat of FUTURA Sealer Coat @ 8–10 sqm, and after 4–5 hours applying two coats of FUTURA-5 PLUS @ 4–4.5 sqm/2 coats, including erection and dismantling of scaffolding up to 9-storey height complete all as specified and directed.Note: Rate includes filling cracks with acrylic polymeric non-shrink compound |
| 131 | M&L for removal of existing aluminium window glass/wire-mesh shutter not exceeding 1.50 sqm, cleaning the track/glass/aluminium sections, and refixing the same shutter with new bearings, complete all as specified and directed by Engr-in-Charge. |
| 132 | M&L for removal of existing aluminium window glass/wire-mesh shutter exceeding 1.50 sqm, cleaning the track/glass/aluminium sections, and refixing the same shutter with new bearings, complete all as specified and directed by Engr-in-Charge. |
| 133 | M&L for linoleum flooring 2 to 3 mm thick, made of PVC-based antimicrobial, long-lasting, odourless material, complete all as specified and directed by Engr-in-Charge. |