| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 2 | M&L for plain cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate as in surface channels and base of drains complete all as specified and directed. |
| 3 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds , mitred/stopped ends etc complete. |
| 4 | Demolition of brick work in cement mortar incl all quoins, arches, pillars etc, but excluding ashler facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 5 | M&L brick work with fly ash bricks straight or curved on plan exc 6 M mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 6 | M&L brick work with sub class B bricks burnt straight or curved on plan exc 6 M mean radius built in cement mortar except brick complete all as specified and as directed. |
| 7 | Taking down cement plaster including racking out joints hacking for key and scrubbing down with water etc complete all as specified and directed. |
| 8 | M&L rendering 15mm thick in cement plaster 1:4 on surfaces fair faces of brick work and surface finished even and smooth without using extra cement with WPC as per manufacture instruction complete all as specified. |
| 9 | Supply only liquid water proofing compound |
| 10 | M&L for two coats of cement base paintincl preparation of newsurface of wall complete all as specified and as directed. |
| 11 | M&L for one coats of cement base paintincl preparation of old decorated surface of wall complete all as specified and as directed. |
| 12 | M&L preparing Old plastered or unplastered surfaces of wall and applying one coat of white wash on old decorated surface of wall complete all as specfied and direcetd. |
| 13 | M&L for one coats of weather coat floor guard or red apex paint incl preparation of old decorated surface of wall/path complete all as specified and as directed. |
| 14 | M&L for 300x300x25 mm thick rubber moulded coloured chequered cement concrete coloured tiles set & jointed in neat cement slurry and pointed with cement & pigment to match the shade of tiles in floors over and incl 15 mm thick screed bed in CM 1:4 complete all as specified and as directed. |
| 15 | M&L for 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in foot parth/parks/lawns or light traffic parking etc., made by table vibratory method using PU mould, laid in required colour & pattern over and incl 25mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer throughvibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete including dismantling of old paver block all as specified and directed. |
| 16 | M&L for 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in foot parth/parks/lawns or light traffic parking etc., made by table vibratory method using PU mould, laid in required colour & pattern over and incl 25mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer throughvibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete including dismantling of old paver block all as specified and directed. |
| 17 | M&L applying 2 coats of synthetic enamel paints on new steel surfaces over a coat of red oxide primer including surface preparation over 10 cm width and girth complete |
| 18 | M&L applying one coats of synthetic enamel paints on old steel surfaces including surface preparation over 10 cm width and girth complete all as specified and directed. |
| 19 | Dismantling posts or struts (wood, steel or RCC) any section including taking out embedded portion and making good disturbed ground post embedded in concrete , brick work, masonry etc complete. |
| 20 | Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out , returning , filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm , watering and removing surplus soil to a distance n exc 50m and making good sufrace in soft/loose soil. |
| 21 | M & L for plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation/mass concrete/sub base complete all as specified. |
| 22 | S & F post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc , flat iron fillets (for securing wire mesh etc) including all necessary drilling , bolting and riveting etc and similar work conforming to Fe 4410-O or Fe 130-O. |
| 23 | S & F post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc , flat iron fillets (for securing wire mesh etc) including all necessary drilling , bolting and riveting etc and similar work conforming to Fe 4410-O or Fe 130-O except steel complete all as specified and directed. |
| 24 | S & F mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 30 cm long and dia meter of neck in mm n exc. 12mm complete all as specified and directed. |
| 25 | S & F of chain link fencing including line wires 3.00 mm dia and 100 x 100 mmmesh size and type of 4.00 mm dia GI wireof standards , rails , straining bolts etc including provision of binding wire complete all as specified and directed. |
| 26 | M&L for 10mm dia and over mild steel TMT bars, cut to length , bent to shape required including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete. |
| 27 | S&F as in repairs Galvanised 2 strand , steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rail straining bolts including securing or tying at crossings with and provisons of galvanised mild steel wire, staples or steel pins etc as directed (each line wire to be measured). |
| 28 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed. |
| 29 | S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering , running rails and guides) and hanging also fastening and fixing complete of Fe 410 W (Gde E-250) quality \"B\". |
| 30 | Dismantling Asbestos Cement/CGI (Corrugated, Semi corrugated etc.) sheets in roof coverings complete all as specified & directed. |
| 31 | S&F pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 55- Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 32 | Excavatingin trenches , n.exc 1.5 mtr wideor 10 Sqm on plan and n.exc 1.5 m in depthfor foundation etc or for shafts, manholes etc and gettingout in soft/loose soil completeall as specified. |
| 33 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n exc 25 cm, complete all as specified and directed. |
| 34 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm of soil complete all as specified and as directed. |
| 35 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point of soil complete all as specified and directed. |
| 36 | Dismantling floor hearth or wall tilling including cement mortar bedding (but not backing ) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 37 | M&L for granite (z black or as approved) tiles 20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing types over 15mm thick screed bed in CM 1:4 complete. |