| 1 | Outdoor Lighting Installation, Steel Tubular Pole, M.S. Pipe, G.I. Pipe, Pole CAP etc Supplying of Swaged Steel Tubular pole as per IS 2713, Pt. II, 1980 for following designation and of following dimensions.(Outside dia & thickness are given in Annexture -1)e) 410 SP - 9 ; 7.5 Mtr., 110.00 Kg. |
| 2 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 138. GI reducer (heavy) 80/65 mm x 20 mm |
| 3 | Outdoor Lighting Installation, Steel Tubular Pole/ M.S Pipe/ G.I. Pipe, Pole CAP etc. Supplying & Fixing of m.s. Sole plate (450x450x6m) at the bottom of pole. |
| 4 | SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Earthing Installation ... with Pipe Electrode.Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (HOT Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(a)By ISI Medium GI pipe. |
| 5 | SUPPLYING 200 WT LED STREET LIGHT WITH SYSTEM EFFICACY 110 LUMEN/WATT, 10KV SPD INCLUDED IP66 PROTECTION, HIGH POWER LEDS WITH SECONDARY LENS, TOUGHENED GLASS COVER, BIS APPROVED SILICON GEL FILLED POTTED DRIVER FOR VIBRATION PROOF.( MAKE:PHILIPS/HAVELLS/CROMPTON/BAJAJ ) WITH 5 YEARS ONSITE WARRANTY. |
| 6 | SUPPLY OF 240VAC ANALOG TIME SWITCH FOR ON-OFF CONTROL OF STREET LIGHT (UNIFIED SCHEDULE OF RATES (M&E) (PART-A)IRRIGATION & WATERWAYS DEPARTMENT W.E.F 10TH MAY 2022 PAGE NO 105 REF NO. 5.3 D13) |
| 7 | SUPPLY OF 3 POLE POWER CONTACTOR TYPE ML3, 40A CURRENT RATING (UNIFIED SCHEDULE OF RATES (M&E) (PART-A)IRRIGATION & WATERWAYS DEPARTMENT W.E.F 10TH MAY 2022 PAGE NO 106 REF NO. 5.3 D16) |
| 8 | SUPPLY OF 3 POLE THERMAL OVER LOAD RELAY TYPE MN-5, RELAY RANGE 14A TO 23A CURRENT RATING (UNIFIED SCHEDULE OF RATES (M&E) (PART-A)IRRIGATION & WATERWAYS DEPARTMENT W.E. F 10TH MAY 2022 PAGE NO 106 REF NO. 5.3 D30) |
| 9 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection Legrand FP 63 A |
| 10 | Laying on Wall / surface with Saddles / clamps.(b)Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (HOT Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 11 | Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/):Size in Sq. mm, No & dia. of wire in mm , No of Core - 25 7/2.24 4 |
| 12 | SCHEDULE OF RATES FOR OH LINE INSTALLATION (LT DISTRIBUTION).Erection of Poles.Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work(site including filling up the excavated earth pit with shifted soil and ramming properlyUpto 9.0 mtr. Size 0.6x0.6x1.70 mts |
| 13 | Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of(approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. FOR receiving fresh coat of paint.Upto 9.0 mtr. long pole.(i)1st coat of aluminium paint over 1 coat of RO priming |
| 14 | Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of(approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. FOR receiving fresh coat of paint.Upto 9.0 mtr. long pole.ii2nd coat of aluminium paint over 1st coat |
| 15 | (H) Street lights :3. Fixing outdoor type fluorescent/SV/MV light fitting on pole including S&F 40 mm dia x 1.68 mts. long GI Pipe (ISI Medium) bracket with 40 mmx10 mm thick, MS clamp etc. and providing wiring with 2x1/1.40 PVC insulated & sheathed wire (single core) partly in GI conduit & partly through above bracket from OH line to the fitting, without control switch, incl. making connections and painting |
| 16 | Erection of Galv. (HOT Dip) Cross arms/ `D... Iron Clamp7).Supplying & Erection of Galv. `D... iron complete with suitable pole clamp 75mmx88mm porcelain shackle insulator & 15 mm dia Galv. bolts & nuts. incl. painting |
| 17 | Erection of Galv. (HOT Dip) Cross arms/ `D... Iron Clamp8).M Supplying & Erection of Galv. `D... iron complete with suitable pole clamp 100mmx114mm porcelain shackle insulator & 19 mm dia Galv. bolts & nuts. incl. painting |
| 18 | Supplying Al.conductor PVC insulated and sheathed unarmoredcable (1.1KVgrade, Gloster/Havells/Polycab). 10sqmm x 2core |
| 19 | Supply and drawing of 7/14 SWG galvanised stranded wire for drawing unarmored cable (supply of cable is not included in the scope) by catenary system of wiring with 3nos. reel insulator per mtr. and binding with binding wires etc,as reqd. for drawing |
| 20 | Drawing of unarmoured cable of suitable size (supply of cable is not included in the scope)on existing Galvanized stranded wire for centenary system with reel insulators and binding wires. |
| 21 | Supplying Al.conductor PVC insulated and sheathed unarmoredcable (1.1KVgrade,Gloster/Havells/Polycab). 4sqmm x 2core |
| 22 | Laying through RCC/Hume/GI Pipe.(a)Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench FOR single, 2, 3, 3... & 4 core |
| 23 | Finishing cable ends.(b)Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.4 core 25 sqmm cable |
| 24 | (H) Street lights :2. Distribution wiring FOR steel light on pole FOR outdoor fluorescent/SV/MV light fitting with 2x1/1.40 PVC insulated and sheathed wire (single core) in 15 mm dia GI Pipe (ISI Medium), without control switch, incl. fitting and fixing the light fitting by providing 32 mm dia GI Pipe bracket of lengh 1.05 mts, on pole incl. S&F sutable MS flat clamps with bolts, nuts etc. as required and painting |
| 25 | Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required |
| 26 | S/F of special head type M S loop box (3 mm thick) with connecting bar and other accessories fixed on the top the pole as required and as per direction of Engineer-In-Charge. For 3 phase connection. |
| 27 | SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION - REPAIR 13. Providing CC (6:3:1) muffing 450x450x600 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if any incl. fixing only loop box if necessary (a) Without Loop Box |
| 28 | Sub Total |
| 29 | GST 18% |
| 30 | CESS 1% Please Enable Macros to View BoQ information |