| 1 | BREAK-UP OF LT SWITCHGEAR (COMPLETE SCOPE) |
| 2 | MODIFICATION IN BOILER MCC UNIT#1 |
| 3 | MODIFICATION IN USS UNIT#1 |
| 4 | MODIFICATION IN SB MCC Unit-1 |
| 5 | MODIFICATION IN DCDB UNIT#1 |
| 6 | MODIFICATION IN EMERGENCY MCC UNIT#1 |
| 7 | MODIFICATION IN BOILER MCC UNIT#2 |
| 8 | MODIFICATION IN USS UNIT#2 |
| 9 | MODIFICATION IN SB MCC Unit-2 |
| 10 | MODIFICATION IN DCDB UNIT#2 |
| 11 | MODIFICATION IN EMERGENCY MCC UNIT#2 |
| 12 | MANDATORY SPARES AS PER ANNEXURE-E OF TECHNICAL SPECIFICATION |
| 13 | Bus bar support insulators of each type |
| 14 | 40 mm Round Insulator |
| 15 | Two way Insulator |
| 16 | Control busbar support chanel |
| 17 | Vertical Busbar support Big |
| 18 | Vertical Busbar support Small |
| 19 | Breaker control switches of each type |
| 20 | 16A, 240V AC, 4 POLE , 2 POSITION SEL. SWITCH ,BASE TYPE |
| 21 | Indicating lamps/ LEDs |
| 22 | RED Indication Lamp-240V AC |
| 23 | Yellow Indication Lamp-240V AC |
| 24 | Blue Indication Lamp-240V AC |
| 25 | Red Indication lamp-110V AC |
| 26 | Green Indication lamp-110V |
| 27 | AC Amber Indication lamp-110V |
| 28 | AC Red Indication lamp-220V DC |
| 29 | Green Indication lamp-220V DC |
| 30 | Blue Indication Lamp-220V dC |
| 31 | White Indication Lamp-220V dC |
| 32 | Amber Indication Lamp-220V dC |
| 33 | CT\"s of different ratings and type |
| 34 | CT Rating-200/1A CL-5P20 |
| 35 | CT Rating-200/1A CL-1 |
| 36 | CT Rating-250/1A CL-5P20 |
| 37 | CT Rating-2501A CL-1 |
| 38 | CT Rating-300/1A CL-5P20 |
| 39 | CT Rating-300/1A CL-1 |
| 40 | CT 100/1A Metering, CL-10 10VA rasin cast |
| 41 | MCBs of different ratings |
| 42 | MCB 6A DP-240VAC |
| 43 | MCB 10A DP-240VAC |
| 44 | MCB 16A DP-240VAC |
| 45 | MCB 6A DP-110VAC |
| 46 | MCB 10A DP-110VAC |
| 47 | MCB 16A DP-110VAC |
| 48 | MCB 6A DP-220VDC |
| 49 | MCB 16A DP-220VDC |
| 50 | MCB 6A 4P-240VAC |
| 51 | MCB 6A SP-240VAC |
| 52 | MCB 10A SP-240VAC |
| 53 | Breaker closing coil |
| 54 | Closing Coil 220 V DC |
| 55 | Breaker tripping coil |
| 56 | Tripping Coil 220 V DC |
| 57 | Breaker fixed contact assembly |
| 58 | Main Fixed Contacts (Upper Terminals) (1 sets for different capacity ) |
| 59 | Spring charging motors |
| 60 | Spring Charging Motor |
| 61 | Arc chutes of each type |
| 62 | Arc Chutes |
| 63 | Arcing contacts fixed and moving type |
| 64 | Arcing Contacts (Set of 1 No. Fixed 1 No. Moving 1 No.) |
| 65 | Power contacts of each type (a) fixed, (b) moving |
| 66 | Main Fixed Contacts (Upper Terminals) |
| 67 | Main Moving Contacts Assembly |
| 68 | Auxiliary contact assembly |
| 69 | Auxiliary Isolating Contact Assembly |
| 70 | Numerical Relays of each type (2 Nos. each) |
| 71 | Numerical Relay 7SJ66 |
| 72 | Thermal over load relay, 2 Nos. of eachrating |
| 73 | Thermal over load relay 7-10A |
| 74 | Thermal over load relay 9.0 -13.0 |
| 75 | Thermal over load relay 12.0 -18.0 |
| 76 | Thermal over load relay 48.0 ~ 65 .0 |
| 77 | Current & voltage transducer |
| 78 | CURRENT TRANSDUCER (DC),4-20mA, DUAL O/P,AUX -220V DC |
| 79 | VTD |
| 80 | Terminals for outgoing (FGDO) - 20% of installedquantity |
| 81 | FGDO-160A |
| 82 | FGDO-250A |
| 83 | Energy meters, ammeter, voltmeter , TVM |
| 84 | MULTIFUNCTION METER 3PH, 4W AUX.-220V DC WITH PULSE OUTPUT &COMMUNICATION FACILITY |
| 85 | AMMETER Ratio-100/1A SQ96, TAUT BAND, 90 DEGREE DIFF., ACC. CL.1.0 |
| 86 | AMMETER Ratio-800/1A SQ96, TAUT BAND, 90 DEGREE DIFF., ACC. CL.1 |
| 87 | MCCB |
| 88 | MCCB TP ADJ O/L & S/C-16 |
| 89 | MCCB TP ADJ O/L & S/C-32A |
| 90 | MCCB TP ADJ O/L & S/C-125A |
| 91 | MCCB MOTOR S/C -16A |
| 92 | MCCB MOTOR TP S/C-125A |
| 93 | MCCB TP ADJ O/L & S/C 200A TM based-250A |
| 94 | Push buttons |
| 95 | PUSH BUTTON-SPRING RETURN WITH 1NO+1NC AUX, CONTACT |
| 96 | E PUSH BUTTON-SPRING RETURN WITH 1NO+1NC AUX, CONTACT |
| 97 | Power and auxiliary contactors(10% or minimum one of each rating and type of installed quantities |
| 98 | 3P POWER CONTACTOR-16A |
| 99 | 3P POWER CONTACTOR-32A |
| 100 | 3P POWER CONTACTOR-65A |
| 101 | 3P POWER CONTACTOR-80A |
| 102 | Auxiliary contactors AC |
| 103 | Auxiliary contactors DC |
| 104 | 24V ON-OFF relay (interposing) -10% or minimum one of each rating and type of installed quantities |