| 1 | Material and labour for brick work with sub class \"B\"brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 including all quoins, arches, pillars etc complete all as specified and directed |
| 2 | Demolition of brick work or stone / bouldermasonry includingall quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed. |
| 3 | Material and labour for brick work with sub class ‘B’ bricks (old size), straight or curved on plan to any radius as inhalf brick thick walls built in cement mortar 1:4 complete all as specified and directed. |
| 4 | Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified |
| 5 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 6 | Material and labour for PCC (1:4:8)type D2 (using 40 mm graded stone aggregate) for foundation / mass concrete complete all as specified and directed. |
| 7 | Material and labour for rendering 15 mm thick on brick work or concrete surfaces in cement mortar (1:4), finished surfaces even and smooth complete all as specified and as directed. |
| 8 | Material and labour for 15 mm thick renderingon brick work or concrete surfacein cement mortar 1:6, surface finished even and fair complete all as specified and as directed. |
| 9 | Material and labour for PCC 1:3:6 Type C1 using 20mm graded stone aggregate as in surface chanels and drains etc complete all as specified and directed. |
| 10 | Material and labour for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregates) as in coping, benching, anchorage blocks, lintels upto 1.5m clear span,cills, steps, sesmic & other similar bands, plinth course, lacing course, parapets & ralling upto 60 cm in height, coping, kneelers, apex stones, bed plates, kerbs not provided for water trought & the like including weathering, slightly rounded or chemfered angels & throating,including necessary from work etc complete all asspecified and directed. |
| 11 | Supply and fixing of mild steel framed work such as door frames, grills, gratings, etc, with ends of bars shouldered and / or riveted or forged into spikes; framed guard bars; frame work of water tanks and similar work confirming to Fe-290 Gde-E-165 including necessary welding, drilling hole complete all as specified and directed. |
| 12 | Material and labour for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 13 | Taking down chowkhats or frames n. exc 1.5 sqm each without taking off shutter from the frame complete all as specified and directed. |
| 14 | Taking down chowkhats or frames exc. 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed. |
| 15 | Supply and fixing of pressed steel frames of size 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including sanding, tarring backs of chowkhats, PCC 1:2:4 type B-0filling in frame and for holdfast, 2 Nos 12 mm dia MS tie bars at the bottom of frame and one shop coat of red oxide primer etc complete all as specified and directed. |
| 16 | Supply and fixing of factory made 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including provision of suitable blocks for taking mortice locks, latches or other fittings complete all as specified and directed. |
| 17 | Supply and fixing of 30 mm thick moulded WPC factory made 100% solid door (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10 mm deep mould on single side with wood grain texture and back side palin with density not less than 600 Kg/cum.Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fireetardant and having screw holding capacity complete all as specified and directed. |
| 18 | Supply and fixing of factory made 100 % solid wood plastic composite (WPC) door frame 75x50 mm made from wood plastic composite (single extruded process) material with density 780 Kg/Cum from ISO certified company door should be water proof, termite proof, fire retardant and having good screw h.olding capacity all as per specification and drawing as directed |
| 19 | Supply and fixing of power coated ventilator fixed type and frame made with aluminium section with and including partly glass and partly stainless steel wire mesh and including aluminium grill of aperture not more than 40 sqcm (as specified below), aluminium sections shall be of size as given below. Frame : 44.5 x 44.5 mm x 1.98 mm thick including 5mm thick frosted in glassfixed with rubber gasket with aluminium beading and stainless steel wire mesh of 0.63 mm nominal dia wire and average width of aperture 1.40 mm completeincluding taking down old window/ventilator etc complete all as specified and directed. |
| 20 | Material and labour for aluminum alloy powder coated standard hollow section as mentioned below window frame (Bombay sliding) with two glazed shutter andone noswire gauged shutter sliding type, with aluminum sections as per Series-A(15mm) 3 track of Jindal section numbers for sliding windows,and glazed with tinted glass coloured glass 4mm thick, fixed with glazing clips, rubber beading / gasket anodised beading, screw and lock type handle of size 75mm, 2 Nos aluminum tower bolt 150mm long with stainless steel grill consisting of 12 mm square bar & 40 x 5 mm thick SS flat all around incl making good of existing surfaces with plaster and external (cement base paint)/ internal (OBD) finishes complete all as specified and directed. Shutter Top & bottom size : 37.50x15x1.60mmShutter inner lock size 37.50x15x1.60 mm Shutter side (Handle) size 37.50x15x1.36mmChowkhat bottom size : 50.30x26x1.20mmChowkhat top & sides size:50.30x26x1.00mm |
| 21 | Supply and fixing of stainless steel barrel tower bolts 150 mm long one piece and fixed complete all as specified |
| 22 | Supply and fixing of stainless steel butt hinges, medium weight 100 mm long one piece and fixed with screws/welded to frame, complete all as specified and directed. |
| 23 | Supply and fixing of stainless steel handles 150 mm long one piece and fixed with screws/welded to frame, complete all as specified and directed. |
| 24 | Supply and fixing of 300 mm long stainless steel sliding door bolt (bolt not less than 12 mm dia) with hasp & staple and fixing clips of SS sheet, and SS fixing boltsand fixed complete all as specified and directed. |
| 25 | Supply and fixing of floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed to floor of size 140 mm complete all as specified and directed. |
| 26 | Material and labour applying two coats of synthetic paint on newwooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete all as specified and directed. |
| 27 | Dismantling of asbestos cement (corruga ted, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 28 | Supply and fixing of pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and directed. |
| 29 | Dismantling of framed or unframed timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed |
| 30 | Supply and fixing of rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors, post, pipes; fixed with angle cleats or other connecting plates Fe-290 (Gde E-165 complete all as specified and directed |
| 31 | Supply and fixing in repair of SS grade 204 drapery rod 20mm diaincluding decorative brackets, decorative finals at both ends complete all as specified |
| 32 | Material and labour for 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 33 | Material and labour for non skid / mat finish ceramic colour tiles of size 300 mm x 300 mm and 6- 7 mmthick, in floors etc, set and jointed in neat cement slurry @ 3 Kg/Sqm and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 34 | Material and labour for glazed ceramic colour tiles size 300 mm x 450 mm x 6-7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry @ 3Kg/Sqm and pointed in coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 and dismantling of existingwall tiling including cement mortar bedding (but not backing) andrubbish off the premises complete all as specified and directed. |
| 35 | Material and labour for non-skid / mat finish designed coloured joint free ceramic tiles of size not less than 400 mm x 400 mm x6- 7 mm thick in floor, set and jointed in neat cement slurry @ 3Kg/Sqmand pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:6 and dismantling of existingtiling including cement mortar bedding (but not backing) andrubbish off the premises complete all as specified and directed. |
| 36 | Supply and fixing in repair of PVC connection 15 mm dia 450 mm long with brass fly nut at both ends complete all as specified and directed. |
| 37 | Supply and fixing in repair of vitreous China wash down (EWC) water closet pan(pedestal pattern), white (excluding flushing cistern and flush pipe) including seat and cover white for pedestal pattern complete all as specfied and directed. |
| 38 | Supply and fixing in repair of 10 litre capacity PVC low level cistern ‘ white’ with inlet, float valve including brackets with 32 mm dia PVC pipe/bend 600 mm long complete all as specified and directed. |
| 39 | Supply and fixing ofCP Health Faucet with 1.20 mtr metalic expandable tube & hook complete all as specified and directed and approved by Engr-in-Charge. |
| 40 | Supply and fixing in repair of vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and directed. |
| 41 | Supply and fixing in repair of pillar taps, brass, with capstan head, fancy type chromium , screwed down high pressure with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed. |
| 42 | Supply and fixing in repair of brass chromium platedovehead shower with shower arm complete all as specified and directed. |
| 43 | Supply and fixing in repair of 15 mm bore angle cock/stop valves, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified anddirected. |
| 44 | Supply and fixing in repair of 15mm bore bib taps long bodycast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 45 | Supply and fixing in repair of CP grating 100mm to 125 dia round fix on floor/ nahani trap with hole/without fixed with cement mortar, complete all as specified and directed. |
| 46 | Taking up or down steel tubing and connection incl removal from site bore of pipe 15mm complete all as specified and directed. |
| 47 | Taking up or down steel tubing and connection incl removal from site bore of pipe 20mm complete all as specified and directed. |
| 48 | Supply, fixing, laying and testing 15 mm dia (Nominal bore) galvanised iron water tubing \"medium grade\" with and including all GI fittings such asunions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 49 | Supply, fixing, laying and testing 20 mm dia (Nominal bore) galvanised iron water tubing \"medium grade\" with and including all GI fittings such asunions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 50 | Material and labour for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 10cm but not exceeding 20cm girth, complete all as specified and directed. |
| 51 | Supply and fixing in repair of 75 mm bore PVC (SWR) pipe single socketed in any length with rubber ring, fixed on wall / laid in trenches complete all as specified and directed. |
| 52 | Supply and fixing in repair of 110 mm bore PVC (SWR) pipe single socketed in any length with rubber ring, fixed on wall / laid in trenches complete all as specified and directed. |
| 53 | Supply and fixing in repair of75 mm bore PVC (SWR) bend with oval acess door ,\"T\"socket reducer etc complete all as specified and directed. |
| 54 | Supply and fixing in repair of110 mm bore PVC (SWR) bend with oval acess door ,\"T\"socket reducer etc complete all as specified and directed. |
| 55 | Supply and fixing of false ceiling ofDesigner tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizental level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos \"T\" of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main \"T\" at 600 mm c/c toform a grid of 1200x600mm and secondary cross \"T\" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mmand laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable wire of 4mm dia with galvanised butterfly level clips, spaced at 1200mm c/c along main \"T\", bottom exposed width of 15mm of all \"T\"\" sections of 4mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, including taking down existing ceiling of any type all complete at all heights as per direction of Engineer-in-Charge including dismantling existing false ceilings etc complete all as specified and directed. |
| 56 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified |
| 57 | Material and labour for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified in SSR Part I and directed. |
| 58 | Material and labour preparation of new plastered surfaces of external wall and application two coats of 1st quality exterior emulsion weather coatpaintsover a coat of alkali resistant priming paint complete all as specified and directed. |
| 59 | Supply and fixing of 1000 Litres capacity rotational moulded polyethylene water storage tanks, three layered (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including 20mm dia GI pipe light grade washout pipe 450mm long with plug and 20mm dia GI pipe light grade over flow pipe 600mm long with fittingincluding PTMT float valve 20mm dia, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball complete all as specified and directed. |
| 60 | Supplying, erecting, testing and commissioning raising & Lowering type 16 meter or next higher available height mast system hot dip galvanised (inside and out side ) in single dip , suitable for wind velocity as per IS 875 part 3 with only one longitudinal seam weld per section but without circumferential weld including accessories viz head frame 2- point suspension system sith steel wire rope 6mm dia (7/19 guage)construction, trailing cable, double drum winch, galvanised lantern carriage arrangement suitable for 9 luminaries symetrically, lightning finial, aviation obstruction light ,RCC foundation bolts,nuts, anchor plates ,templates , trailing cable & intergral power tool for raising and lowering operation of high mast complete all as specified and directed. |
| 61 | Material and labour for earthing complete withgalvanised earth plate electrode 600x600x6.0mm thick, buried directly in ground (Earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level connected with galvanised iron earth strip 32x6mm by means of bolts, nuts, check nuts and washer of galvanised iron or steel complete with 40 mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. including excavation and earth work in any type ofsoil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 ofSSR 2009 (Part-I) complete all as specified and as directed. Note :- (i) Earth lead strip and its protection pipe upto and including 7.50 mtr only from top of earth electrode are included under this item.(ii)On testing if the earth resistance is not obtained within permissible limit, earthing will be re-done at NO extra cost ,till the desired earth resistance is obtained. (iii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted. |
| 62 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equiped with IP66 protection with impact and corrosion resistant complete with driver and lampcomplete with all accessories and including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed. |
| 63 | Material and labour for laying, jointing and testing of XLPE insulated & PVC sheathed, armoured heavy duty multistranded electric cable with aluminium conductor of size 10 Sqmm 4 core, 1100 volts grade in trenches/ ducts/ along poles/ through pipe/ under road/ PCC etc and connecting with new aluminium lugs etc complete all as specified and directed: Notes:(a)Excavation, returning, removal, sand cushioning, cable protection covers, GI protection pipe etc shall be measured and paid separately.(b)Any damage done during cable excavation to the existing UG infra like UG pipelines, UG electric cables, OFC etc shall be repaired by the contractor at their own expenses.(c)Cost of T&P required for handling/ laying of cable is deemed to be included in the rate quoted by the contractor. |
| 64 | Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unseviceable LT Cable for laying of cable and getting out complete all as specified and directed. |
| 65 | Material and labourfor sand cushioning and covering of UG cable using crushed metal sand in trenches for cable protectioncomplete all as specified & directed. NOTE: - Punned thickness shall be measurement & paid |
| 66 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in hard /loose soil complete all as specified and directed. |
| 67 | Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 68 | Material and labour for for sub class \"B\" bricks well burnt of size 23 x 11.5 x 7.5 cm for protection of UG cable laid dry flat over the cable width wise across the length of the cable and abutting each other with gap less than 10mm between the adjacent bricks in trenches complete all as directed. |
| 69 | Supply, installation and testing of factory made astronomical street light control panel housed in hinged polycarbonate box of min size 600x315x214mm (system voltage 415 Volt, 3 phase 4 wire, 50 Hz,) consisting of MCCB four pole, 16 KA, (Ics=100%lcu) 63 Amp 01 No, contactor three pole 80 Amp AC 3 type - 01 No with astronomical timer switch digital type with lithium ion battery and MCB\"s singal pole 63 Amps 240 Volts 10 KA 04 No mounted on 1.6 mm thick CRCA plate duly powder painted with seperate auto manual rotary selector switch & ON/OFF indiactors fixed on door, gun metal glands for cable entry from bottom for incoming and outgoing cables made with IP 65 degree of protection (EN60529), dust proof, water tight, light weight, acid resistant, corrosion proof insulated & shock proof, fire retardant, UV resistant, with internally embeddedgasket fitted with required terminals including mounting arrangement i.e. Gl clamp, nut bolts washers etc complete all as specified and directed. |
| 70 | Supply, install,testing and commisssioning of reversible type (Hot and cool) split air conditioningunit 1.5 Ton , 3 star, eco friendly refrigerant complete with drive motor, air cooled copper condenser with all accessories varied speed and dual rotary compressor, including fixing the out door units with mounting bracket , made Up of heavy duty GI steel, wall mounted type, Powder coatedincl nuts & bolt etcas per manufacture recomendation and fixing of room unit on wall , providing and making interconnection , including refregerent piping with nitryle rubber insulation and control cable from indoor to out door , first charging of refrigerent gas including cordless remote etc complete all as specified and directed. (Test certificate of AC to be submitted) |
| 71 | Supply, fixing and testing of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 90V to 300V with output voltage stailized at 230V with accuracy of + 2.5% and of capacity 05 KVA complete all as specified and directed. |
| 72 | Supply and fixing of distribution box MCB protected socket with Plastic enclosure (Surface mounitng ) 20 AMP MCB Combo box DP including plug top complete all as specified and directed |
| 73 | Supply, installation and testing of electric water heater, storage type ABSbody with Glass linkedtank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed. (Test certificate of geyser to be submitted) |
| 74 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator (min 100w), Fan hook split type fabricated out of 12mm dia steel bar of length 30 cm duly painted with rod oxide old black paintand all accessories required to connection, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete all as specified and directed |
| 75 | Supply and fixing of exhaust fan exhaust fan made of steel body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 450mm, complete with louvers, shutters and connecting up ceiling rose to connectorblock of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed. Note : Old fan should be deposited to AGE E/M-II store yard. (Test certificate of fan to be submitted) |
| 76 | Supply and fixing of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep250 m, complete with louvers, shutters and connecting up ceiling rose to connectorblock of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed. Note : Old fan should be deposited to AGE E/M-II store yard. (Test certificate of fan to be submitted) |
| 77 | Supply and fixing of 15 mm bore angle cock/stop valves, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified anddirected. |
| 78 | Supply and fixing of 15mm bore bib taps long bodycast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 79 | Material and labour for submain wiring with 3 runs(N+P+E) of 4 Sqmm single core,PVC insulated, unsheathed, multistranded copper conductorFRLS cable 1100 volts grade drawn throughand including concealed/surfacePVC conduit pipe of medium duty not less than20 mm dia including necessary PVCconduit specials and connecting with suitable size thimble complete all as specified anddirected. Note:-3 runs of4 Sqmm size PVC copper cable, and one run of PVC conduit shallbe measured as one unit length. |
| 80 | Supply and fixing of PVC connection pipe (suitable to cold water) of 15 mm dia, upto 450mm long with two brass CP hexagonal nuts adopter rubber washer complete all as specified and directed. |
| 81 | Supply and fixing of PVC connection pipe (suitable to Hot water) of 15 mm dia upto 450mm long with brass flexible tube alongwith CP Hexagonal nuts adopter rubebr washercomplete all as specified and directed. |
| 82 | Material and labour for distribution boardSPN 4 Way double door, for mounting MCBs isolator, ELCBs etc factory made, IS: 13032 marked with valid CM/L Nofabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar and also incoming and outgoing connections with suitable size of lugs/thimbles/glands complete all as specified and directed. |
| 83 | Supply and fixing of MCB SPN240 Volt 10 KA40 Amp conforming to ISI marked including connection with suitable size copper lugs complete all as directed. |
| 84 | Supply and fixing of MCB SP 6 to 32A 240 Volt 10 KA conforming to ISI marked including connection with suitable size copper lugs complete all as directed. |
| 85 | NOTE:- Amount of credit ofRs. 37747.50for retrieved materials is mentioned in Schedule of Credit Page No 26 of tender documents in pdf form which will be deducted offline while acceptance of tender. |