| 1 | Dismantling of old UNSVdamage/rusted PCC pole/steel tubular poles of any size necessary disconnecting cables/over head condcutor and removing unserviceable pole from site, complete all as specified and directed by Engr-in-Charge. |
| 2 | Supply and fixing of steel tubular swaged poles errected vertically with two coat of aluminium paint ovar a coat of red oxide zinc chrome prime in externally exposed to view portion and black bituminous painting to intenal surface and portion embeded in concrete incl making five alternative strips 30 cm wide in different colour above ground level or plinth level incl marking of MES pole No in black paint complete with cast iron base plate, final tapper plug, bolts, nuts and screws as specified type 410 SP-31 (9.00 mtr long), complete all as specified and directed by Engr-in-Charge. |
| 3 | Dismantling of cross arms fixed on steel tubular poles carefully and removing from site, complete all as specified and directed by Engr-in-Charge. |
| 4 | M & L for Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer, complete all as specified and directed by Engr-in-Charge. |
| 5 | M &L for demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level), complete all as specified and directed by Engr-in-Charge. |
| 6 | M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregates for filling in road cuts/hard standing etc , complete all as specified and directed by Engr-in-Charge. |
| 7 | Excavation in trenches not exc. 1.5 metre wide and not exc. 1.50 mtr depth for laying of underground cable, erection of poles etc. and getting out in soft/loose soil including separating serviceable bricks for re-use at site obtained during excavation, complete all as specified and directed by Engr-in-Charge. |
| 8 | Description all as per ser item No 7.00 here-in-beforebut exc. 1.50 metre depth and not exc. 3.00 metre deep, complete all as specified and directed by Engr-in-Charge. |
| 9 | Returning, filling in, including, spreading, leveling, watering and well ramming in layers n.exc. 25 cm in soils, complete all as specified and directed by Engr-in-Charge. |
| 10 | Removing excavated soil n. exc 50 m and depositing where directed at a level n.exc. 1.5 mtr above the starting point , complete all as specified and directed by Engr-in-Charge. |
| 11 | M & L for PCC 1:4:8, type D-2, (using 40mm graded stone aggregate) as in foundation, filling and mass concrete , complete all as specified and directed by Engr-in-Charge. |
| 12 | M & L for PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed. |
| 13 | M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work, complete all as specified and directed by Engr-in-Charge. |
| 14 | S&F double walled corrugated (DWC) pipe of size 40 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground complete, complete all as specified and directed by Engr-in-Charge. |
| 15 | S&F double walled corrugated (DWC) pipe of size 63mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground, complete all as specified and directed by Engr-in-Charge. |
| 16 | S&F double walled corrugated (DWC) pipe of size 50 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground , complete all as specified and directed by Engr-in-Charge. |
| 17 | Taking up oldserviceable/unserviceable UG cable from trench/pcc/interlocking/tiles including disconnection disconection from electrical equipment for replacement , repair and re-layingor re-routing of size including make good the distrubed surface as per existing :- (Earth work shall be measured and paid separately under appropriate items of Sch-\"A\") |
| 18 | 06 Sqmm 3 Coreto 35 Sqmm 3.5 Core |
| 19 | 50 Sqmm 3.5 Coreto 95 Sqmm 3.5 Core |
| 20 | Supply & lay test and commissiong of LT Cable XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) with aluminium conductor , 1100 volts earthed grade cross sectional area as illustrated below Note :Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection to be measured and paid for separately). |
| 21 | 06 Sqmm 03 core |
| 22 | 16 sqmm 4 core |
| 23 | 25 sqmm 3.5 core |
| 24 | 35 sqmm 3.5core |
| 25 | 50 Sqmm 3.5 core |
| 26 | 70 Sqmm 3.5 core |
| 27 | Supply and fixing or laying galvanized steel tubing medium grade (ISI) marked for protection of under ground cable of size 50 mm bore, complete all as specified and directed by Engr-in-Charge. |
| 28 | Supply and fixing or laying galvanized steel tubing medium grade (ISI) marked for protection of under ground cable of size 40 mm bore, complete all as specified and directed by Engr-in-Charge. |
| 29 | M&L for cutting/boring the existing bitumen us road/payment/footpath upto 0.75 mtr in depth, 0.45 mtr in width and getting out excavated material and making good the damaged portion after laying the pipe, returning filling in mass concretePCC 1:2:4 type B2 upto top of the road , complete all as specified and directed by Engr-in-Charge.Note :-(i) M&L for laying of pipe shall be measured and paid separately. |
| 30 | Earthing complete with galvanised steel earth plate electrode size 60 cm x 60 cm,6.3 mm thick burried directly in ground vertically to a depth notless than2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, connected to galvanised iron or steel, earthstrip 32 x 6 mm size by means of nuts, bolts check nuts and washers made of galvanised iron or steel, earth wire protected by galvanised iron pipe 15mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate), pre-cast RCC cover slab 30 cm x 30 cm x 10 cm with one lifting handle made of 8 mm dia MS bar funnel wire mesh, 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical Plate No 5 of MES Schedule Part- I and testing on completion.(Concrete pit shall be 20 cm to 30 cm away from main pit). |
| 31 | Supply and fix SMC street light control box of size 450 x 300 x105 mm including 04 Nos aluminium bus bar of adequate capacity03 phase and neutral, 415 volts including one Nos MCB SPN of 06 Amps capacity including connecting up with the electrical connections and fixing and clamping, locking arrangement, complete all as specified and directed by Engr-in-Charge. |
| 32 | S & F PVC insulated and sheathed 2.5 sq mmThreecore multi stranded, copper conductor cable from junction box/OH line to street light fitting or for engagement lights, complete all as specified and directed by Engr-in-Charge. |
| 33 | Supply and fixing in replacementGI bracket 40 mm dia 1.5 Mtr long light grade made to shape including taking down old and u/s existing fitting, complete all as specified and directed by Engr-in-Charge. |
| 34 | Taking down existing U/S Lt Panel of any type and size and any condition complete including disconnection of electric connection complete from site/wall and making good the distrubed surface, complete all as specified and directed by the Engr-in-Charge. |
| 35 | Supply, install commissioning and testing of cubical out door feeder LT panel board of suitable size platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete made of angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete.The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work.(ii) Panels shall be placed above 0.6 mtr from ground level (iii)Outgoing MCCBs shall be fed with solid busbar connectors and(iii)Cables shall be terminated using gun metal /SS glands. (vi)includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables(v) cable glands for incomingand out going suitable cables is including rate quated by vendover (vi)includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables.Note :- 02 Nos padlock has to be fixed in the panel. The rates of the padlock is included in the quoted rates of panels:- |
| 36 | INCOMING(a)MCCB four pole 250 Amps, 36 KA at 415 Volts-01 No.(b) 400 Amps rated copper bus bar suitable for 3 phase 4 wire system- 01 No.(c)Phase indicating lamp RYB neon type (Set of three ) -01 Set (d)Voltmeter Digital type 0-500 Volts capacity with selector switch.(e) Ammeter Digital type 0-200 Amp capacity with selector switch and CT coils (f) Changeover Switch -250 A, 4 pole-01 Nos OUT GOING(a) MCCB four pole 63 Amps, 25 KA at 415 Volts-01 No(b) MCCB four pole 160 Amps, 25 KA at 415 Volts-03 No |
| 37 | Supply, install commissioning and testing of cubical out door feeder LT panel board of suitable size, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete made of angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete.The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work.(ii) Panels shall be placed above 0.6 mtr from ground level (iii)Outgoing MCCBs shall be fed with solid busbar connectors and(iii)Cables shall be terminated using gun metal /SS glands. (vi)includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables(v) cable glands for incomingand out going suitable cables is including rate quated by vendover (vi)includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables. Note :- 02 Nos padlock has to be fixed in the panel. The rates of the padlock is included in the quoted rates of panels. (Location : Near CSD canteen, Perimeter post light, ACSPP Store Cell |
| 38 | INCOMING(a)MCCB four pole 160 Amps, 25 KA at 415 Volts-01 No.(b) 250 Amps rated copper bus bar suitable for 3 phase 4 wire system- 01 No.(c)Phase indicating lamp RYB neon type (Set of three ) -01 Set (d)Voltmeter Digital type 0-500 Volts capacity with selector switch.(e) Ammeter Digital type 0-200 Amp capacity with selector switch and CT coils OUT GOING(a) MCCB four pole 100 Amps, 25 KA at 415 Volts-04No |
| 39 | Supply, install commissioning and testing of cubical out door feeder LT panel board of suitable size, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete made of angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete.The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work.(ii) Panels shall be placed above 0.6 mtr from ground level (iii)Outgoing MCCBs shall be fed with solid busbar connectors and(iii)Cables shall be terminated using gun metal /SS glands. (vi)includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables(v) cable glands for incomingand out going suitable cables is including rate quated by vendover (vi)includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables. Note :- 02 Nos padlock has to be fixed in the panel. The rates of the padlock is included in the quoted rates of panels. Location : Near Offrs Qtrs |
| 40 | INCOMING(a)MCCB four pole 200 Amps, 25 KA at 415 Volts-01 No.(b) 300 Amps rated copper bus bar suitable for 3 phase 4 wire system- 01 No.(c)Phase indicating lamp RYB neon type (Set of three ) -01 Set (d)Voltmeter Digital type 0-500 Volts capacity with selector switch.(e) Ammeter Digital type 0-200 Amp capacity with selector switch and CT coils OUT GOING(a) MCCB four pole 100 Amps, 25 KA at 415 Volts-05No(b) MCCB four pole 63 Amps, 25 KA at 415 Volts-01 No |
| 41 | Supply, install commissioning and testing of cubical out door feeder LT panel board of suitable size , platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete made of angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete.The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work.(ii) Panels shall be placed above 0.6 mtr from ground level (iii)Outgoing MCCBs shall be fed with solid busbar connectors and(iii)Cables shall be terminated using gun metal /SS glands. (vi)includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables(v) cable glands for incomingand out going suitable cables is including rate quated by vendover (vi)includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables. Note :- 02 Nos padlock has to be fixed in the panel. The rates of the padlock is included in the quoted rates of panels. (, Location : Near Offrs Qtrs, Near CSD Canteen Depot, Main office back side , 15A TA) |
| 42 | INCOMING(a)MCCB four pole 320 Amps, 36 KA at 415 Volts-01 No.(b)500 Amps rated copper bus bar suitable for 3 phase 4 wire system- 01 No.(c)Phase indicating lamp RYB neon type (Set of three ) -01 Set (d)Voltmeter Digital type 0-500 Volts capacity with selector switch.(e) Ammeter Digital type 0-200 Amp capacity with selector switch and CT coils OUT GOING(a) MCCB four pole 100 Amps, 25 KA at 415 Volts-02 No(a) MCCB four pole 100 Amps, 25 KA at 415 Volts-04 No |
| 43 | Supply, install commissioning and testing of cubical out door feeder LT panel board of suitable size, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete made of angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete.The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work.(ii) Panels shall be placed above 0.6 mtr from ground level (iii)Outgoing MCCBs shall be fed with solid busbar connectors and(iii)Cables shall be terminated using gun metal /SS glands. (vi)includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables(v) cable glands for incomingand out going suitable cables is including rate quated by vendover (vi)includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables. Note :- 02 Nos padlock has to be fixed in the panel. The rates of the padlock is included in the quoted rates of panels. (, Location : Dhobi Ghat, Near Officer Qtrs, near AC Shed, Near DSp-NP-47 Block,Near 2 Sub Depot , 01 Sub Depot, ADP Cell Main office) |
| 44 | INCOMING(a)MCCB four pole 400 Amps, 36 KA at 415 Volts-01 No.(b)600 Amps rated copper bus bar suitable for 3 phase 4 wire system- 01 No.(c)Phase indicating lamp RYB neon type (Set of three ) -01 Set (d)Voltmeter Digital type 0-500 Volts capacity with selector switch.(e)Ammeter Digital type 0-200 Amp capacity with selector switch and CT coils(f)Changeover Switch -400 A, 4 pole-01 Nos OUT GOING(a) MCCB four pole 250 Amps, 25 KA at 415 Volts-01 No(b) MCCB four pole 200 Amps, 25 KA at 415 Volts-01 No(c) MCCB four pole 160 Amps, 25 KA at 415 Volts-02 No(d) MCCB four pole 100 Amps, 25 KA at 415 Volts-02 No |
| 45 | Supply, install commissioning and testing of cubical out door feeder LT panel board of suitable size, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete made of angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete.The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables .Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work.(ii) Panels shall be placed above 0.6 mtr from ground level (iii)Outgoing MCCBs shall be fed with solid busbar connectors and(iii)Cables shall be terminated using gun metal /SS glands. (vi)includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables(v) cable glands for incomingand out going suitable cables is including rate quated by vendover (vi)includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables. Note :- 02 Nos padlock has to be fixed in the panel. The rates of the padlock is included in the quoted rates of panels. (Location : 43 GR Main Panel, 87 Bde Shoping Comlex |
| 46 | INCOMING(a)MCCB four pole 630 Amps, 36 KA at 415 Volts-01 No.(b)600 Amps rated copper bus bar suitable for 3 phase 4 wire system- 01 No.(c)Phase indicating lamp RYB neon type (Set of three ) -01 Set (d)Voltmeter Digital type 0-500 Volts capacity with selector switch.(e)Ammeter Digital type 0-200 Amp capacity with selector switch and CT coils(f)Changeover Switch -400 A, 4 pole-01 Nos OUT GOING(a) MCCB four pole 250 Amps, 25 KA at 415 Volts-02 No(b) MCCB four pole 200 Amps, 25 KA at 415 Volts-02 No(c) MCCB four pole 160 Amps, 25 KA at 415 Volts-02 No(d) MCCB four pole 100 Amps, 25 KA at 415 Volts-02 No |
| 47 | Supply, install commissioning and testing of cubical out door feeder LT panel board of suitable size, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete made of angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete.The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables .Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work.(ii) Panels shall be placed above 0.6 mtr from ground level (iii)Outgoing MCCBs shall be fed with solid busbar connectors and(iii)Cables shall be terminated using gun metal /SS glands. (vi)includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables(v) cable glands for incomingand out going suitable cables is including rate quated by vendover (vi)includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables. Note :- 02 Nos padlock has to be fixed in the panel. The rates of the padlock is included in the quoted rates of panels. (Location : GE office ) |
| 48 | INCOMING(a)MCCB four pole 400 Amps, 36 KA at 415 Volts-01 No.(b)600 Amps rated copper bus bar suitable for 3 phase 4 wire system- 01 No.(c)Phase indicating lamp RYB neon type (Set of three ) -01 Set (d)Voltmeter Digital type 0-500 Volts capacity with selector switch.(e)Ammeter Digital type 0-200 Amp capacity with selector switch and CT coils(f)Changeover Switch -400 A, 4 pole-01 Nos OUT GOING(a) MCCB four pole 250 Amps, 25 KA at 415 Volts-02 No(b) MCCB four pole 160 Amps, 25 KA at 415 Volts-02 No(c) MCCB four pole 125 Amps, 25 KA at 415 Volts-01 No |
| 49 | Supply, install commissioning and testing of cubical out door feeder LT panel board of suitable size, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete made of angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete.The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables .Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work.(ii) Panels shall be placed above 0.6 mtr from ground level (iii)Outgoing MCCBs shall be fed with solid busbar connectors and(iii)Cables shall be terminated using gun metal /SS glands. (vi)includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables(v) cable glands for incomingand out going suitable cables is including rate quated by vendover (vi)includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables. Note :- 02 Nos padlock has to be fixed in the panel. The rates of the padlock is included in the quoted rates of panels. (Location : 1 FOD Perimeter Boundry ) |
| 50 | INCOMING(a)MCCB four pole 200 Amps, 36 KA at 415 Volts-01 No.(b)300 Amps rated copper bus bar suitable for 3 phase 4 wire system- 01 No.(c)Phase indicating lamp RYB neon type (Set of three ) -01 Set (d)Voltmeter Digital type 0-500 Volts capacity with selector switch.(e)Ammeter Digital type 0-200 Amp capacity with selector switch and CT coils(f)Changeover Switch -200 A, 4 pole-01 Nos OUT GOING(a) MCCB four pole 160 Amps, 25 KA at 415 Volts-02 No(b) MCCB four pole 125 Amps, 25 KA at 415 Volts-01 No |
| 51 | Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system,dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings MCCBs areto busbar spadles to fitted complete base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entryand locking arrangement complete with following :- |
| 52 | Incoming:-(a)MCCB 160 A4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No,Outgoing:-(a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 240 Amp,4 pole, not less than 75 cmlong mounted on insulators 01 setNote- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work.(ii) Panels shall be placed above 0.6 mtr from ground level(iii) Outgoing MCCBs shall be fed with solid busbar connectors and (iii) Cables shall be terminated using gun metal /SS glands.(vi) includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables(v) cable glands for incomingand out going suitable cables is including rate quated by vendover |
| 53 | Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system,dust and vermin proof, made of3.15 mm CRCA MS sheet with Bus bar electrolytic grade Copperand supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 600Amp,4 pole spadles to fitted complete base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hingedwith aprons for cable entryand locking arrangement complete all as specified and directed by Engr-in-Charge. |
| 54 | Post top lantern, LED Warm white , type 40 watt , 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection complete all as specified and directed by Engr-in-Charge.Make:- Philip, Crompton,Bajaj Cat No BGCTNP 40W LED WW or equivalent from the list of make given in particular specification. |
| 55 | LED bollardWarm white lights of 9/10/11 watt capacity including taking down existing unserviceable garden lights of any type/capacity complete all as specified and directed by Engr-in-Charge. Make:Philip, Benlo Crompton, Bajaj Cat No BGBOL 605 9W LED WW or equivalent from the list of make given in particular specification. |
| 56 | LT Cable junction box outdoor shall be made out of PC-GFS (polycarbonate) with glass fiber reinforced and size should be not less than 104mmx104mm x 70 mm (upto Cable Size 6 sq.mm) Black Color . The PC-GFS (polycarbonate) Junction Box shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The Junction Box shall be rated for Degree of ingress Protection IP 66/67/69 in accordance with IEC 60529.Weatherproof, UV-resistant, rainwater-proof, temperature-resistant. The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. The Junction Box shall be complies with requirements of the standards IEC 60998 - 1, IEC 60670 - 22& IEC 60670 - 2 - 5. The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate . For better safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - 2 - 11, DIN VDE 0304 Part - 3,UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 degree Centigrade & Current Carrying Capacity upto 32Amps. The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechanical load shall be in accordance with EN 50298 - 98 for IK 08 including inbuilt5 pole connectors Sepreat Incoming/Output cabling provision, Provided Suitable Cable Glands IP66 RAL 9005 for Cable Entry System and chromium plated clamps and nut bolts complete all as per manufacturer’s instructions.Make : Cat Part :- KF 0606 B of Hensel/Siemens/GE Power/Rittal. Manufacturer should submit routine test certificate of CJB/PJB |
| 57 | Supply, install,150 amp copperBus barwith enclouser wall mounted size 350 mmX300 mmX150mm ,suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system,dust and vermin proof, made of 2 mm CRCA MS sheet for cable entryand locking arrangement, complete all as specified and as directed by Engineer-in-charge |
| 58 | Supply and fixing SPN, DBs double door type for lexic MCB complete with SPN MCB 40 Amp, 10 KA, 240 V fixing on pole with necessary clamp and nut, bolts, complete all as specified and as directed by Engineer-in-charge |
| 59 | Supply and fixing in replacement MS clamp any shape and size along with nuts, bolts and washers etc of sizes, complete all as specified and as directed by Engineer-in-charge |
| 60 | Labour only for cutting/pruning the overhanging or adjacent branches of trees of any girth HT/LT overhead line including cutting the bamboos, removing the shrub from poles and cleaning the jungle below and upto 3.00 metre clear distance from the middle conductor of the line on either Side complete and removing rubbishes from Site, complete all as specified and as directed by Engineer-in-chargeNote : (1) pole to pole distance from 40 to 60 mtrs will be measured as one span. (2) All the precautionary equipment like safety belt, earth road, hand gloves, ladder, and T&P shall be provided by the contractor. (3) The tree pruning will be start within 15 days of commencement of works, If he fails to attend the tree prunning complain the penalty of Rs. 2000 per span will be charged and deducted from the next due RAR. |