| 1 | Demolition of brick work or stone /boulder masonry,built in cement mortar, including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles etc,complete all as specified and directed by Engr-in-charge. |
| 2 | Demolition of cement concrete (reinforced)of any description and in any position not otherwise specifically provided, complete all as specified and directed by Engr-in-charge. |
| 3 | Demolition of cement concrete of any description and in any position not otherwise specifically provided, complete all as specified and directed by Engr-in-charge. |
| 4 | Demolition of granite slabs laid bedded pointed in any mortar or of any description and thickness, complete all specified and directed by Engr-in-charge. |
| 5 | Cement concrete Type C-2 (1:3:6) 20mm aggregates in foundations, fillings and mass concrete , complete all specified and directed by Engr-in-charge. |
| 6 | Brick work with sub class \"B\" bricks straight or curved on plan, exceeding 6 m mean radius with old size bricks, built in cement mortar 1:6, complete all as specified and directed by Engr-in-charge. |
| 7 | 20mm thick Granite, single piece, (of any type) work (table rubbed and polished and moulding of outer edges) in steps, jambs and pillars, window cills, cooking platforms and the like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite with and including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-charge.Note:- The granite wall installation shall be carried out up to any required height, if in case additional fastening components such as nuts and bolts or adhesives are required for proper fixing, the same shall be provided and installed by the contractor at no additional cost. |
| 8 | Plain cement concrete, 1:3:6 type C-2 (using 20 mm graded crushed stone aggregate) as in surface channels or drains etc,complete all as specified and directed by Engr-in-charge. |
| 9 | M&L for 20mm thick rendering on fair faces of brick work or concrete surfaces in cement motor 1:4 and finished even and smooth without using extra cementincluding mixing of liquid water proofingadmixture as per manufcture\"s instructions, complete all as specified and directed by Engr-in-charge. |
| 10 | Supply only integral liguid water profing admixture,complete all as specified and directed by Engr-in-charge. |
| 11 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in coping, benching including weatering slightly rounded or chamfered angles as directed including necessary form work and finishing the exposed surfacescomplete all as specified and directed by Engr-in-charge. |
| 12 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed by Engr-in-charge. |
| 13 | Rolled mild steel work as in roof trusses(framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing(Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to grade Fe-410 W(Gde-E-50) quality-A, steel work complete all as specified and directed by Engr-in-charge. |
| 14 | Rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to grade Fe.290.Gde-E-165, steel work complete all as specified and directed by Engr-in-charge. |
| 15 | Mild steel work as in doors or gates of angle or other section with gusset plate, rails, braces,etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fixings (exclusive of steel sheeting or other covering, running rails and guides)and hanging ;also fastening and fixing complete all as specified. |
| 16 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed by Engr-in-Charge. |
| 17 | M&L prepainted galvalume aluminium zink coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpaas in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge. |
| 18 | M&L prepainted galvalume aluminium zink coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpaas in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge. |
| 19 | M&L for designing, providing fabricated assembing and erection of pre stressed special Arch membrane roofing structure with MS tubular frame work (As per IS structural teel) in desired profile as per conceptual drawing with type II precontraint as per manufacturing and suplying standards by serge Ferrari/vesrseidag/Sioen. The membrane should confirm to the manufacturing and supplying standards by being pre streched in both weft and weft direction manufacturing to platform bet dyanamic stability in both warp and srap direction with approved installaers and manufacture for Arch roofing with and atleast two executed job refrence in the connection. |
| 20 | The fabric must be of HT polyster yarns 1100D tex coated with uniform 230 micron PVC coating over the polyster yarn. The top quote over the PVC must be of height concertation with easy clean availability and superior white pigmantation of the membrane. the dimensional stability of the fabric should be measure as per elongation test of 24 hrs 10 DAN/5cm which should confirm <1%-<1%(EN15977) and residual elongation should confirm <0.4%-0.4% (EN15977) ensuring dimensional stablity in both weft and wrap direction, minmum weight should be 900 to 950 gm per sqm ( EN ISO 2286-2) 4200/4000N/ 50mm (EN ISO1421) and tear strength of 550/500N (DIN53363) and with a guarantee of 10 yrs (with non dereciated guarantee for first three yrears) from manufacturer, pole to pole spacing of fabric should be as Arch drg, Plan area of covering used for cantilever car parking chargeable area will be fabric surface area including the measurement of the fitting used for fixing the civil drawing of foundation ill be provided by the B22supplier and the foundation if any shall be made by contractor. |
| 21 | S.No item No 19.00 contd Measurement for payment shall be taken as tensile febric are. The wind pressure reort alongwith foundation drawing shall be provided by the supplier/ contractor forfuture reference asper direction of Engr-in charge approved by GE Minimum design criteria of structure : Round pipe pillar 250mm dia, Rafter round 125 mm dia connecting Rafter pole to pole 125mm dia cantilever round/ purlin 75 mm dia base plate 450x550 mm, SS plate Nd 25 mm dia (sizes of pillar, rafter, purlin, base plate, SS plate can be change as per direction by Engr-in charge) nut bolt GI wire rope for fabric, Deco primer and paint 900 GSM Sione white fabric, pole to pole distance 3.35m/6.7m clear height is 2.25m, excavation pit size 1m x1mx 1.2 m, lean concrete 150 mm thick (1:4:8) type D2 for col footing, 20 mm dia TT bar in footing and base column at spacing 100mm centre to centre and also refer IS:456 considering wind pressure structural design, foundation of RCC M-30 (Design Mix) all catered work is deemed to be included in unit cost. |
| 22 | Taking down chowkats or frames including shutters (without taking off shutters from the frames) not exceeding 1.50 Sqm each,and removing from site, complete all as specified and directed by Engr-in-charge. |
| 23 | S&F 2nd class hard wood (sal/hollock), glazed and skelton shutters 35mm thick open rebated and prepared to receive glass, gauge,etc. (without sash bars), edges of framing palin, chamfered or rounded, fitted with cut &mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Pt-I Section 8.24(a) supplied and fitted to chowkhats completeincluding fixing only iron mongery such as tower bolt,handle,hinges,aldrop bolt etc, complete all as specified and directed by Engr-in-charge. |
| 24 | S&F factory made, 2nd class hard wood (sal/hollock),plain framed, panelled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both sides, the side of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, 35 mm thick completeincluding fixing only iron mongery such as tower bolt,handle,hinges,aldrop bolt etc complete all as specified and directed by Engr-in-charge. |
| 25 | Solid PVC door frame of size 50 mm x 47 mm made of 5 mm plain colour PVC sheet reinforced with mild steel square tube complete all as specified in clause 8B.3.1 and shown on page 150 of MES Schedule Part-II (2004). |
| 26 | Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified. Make: Rajshri or equivalent as approved. |
| 27 | Mild steel framed work such as grills, gratings with ends of bars shouldered or reveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar works, conforming to Fe-290, Gde E-165, complete all as specified and directed by Engr-in-Charge. |
| 28 | S&F aluminum handles cast type, anodised, 150 mm size complete all as specified and directed by Engr-in-charge. |
| 29 | S&F in repairmild steel cold rolled butt hinges mediumweight 100 mm long, including fixing and welding to pressed steel/wooden door frame if required complete all as specified and directed by Engr-in-charge. |
| 30 | S&F of 200 mm long mild steel barrel tower bolts, stove enameled black, with bright bolt complete all as specified and directed by Engr-in-charge. |
| 31 | S&F of mild steel sliding door bolt plate type250 mm long stove enameled black with bright bolt not less 12 mm dia bolt with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, complete all as specified and directed by Engr-in-charge. |
| 32 | Preparation of new wooden surfaces of any description not otherwise described, exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed by Engr-in-charge. |
| 33 | Pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc and providing one shop coat of primer and tarring back side of frame, complete all as specified and directed by Engr-in-charge. |
| 34 | Pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc and providing one shop coat of primer andtaring back side of frame, complete all as specified and directed by Engr-in-charge. |
| 35 | M&L for providing cement concrete 1:3:6 type C-0 using 12.5mm graded crushed stone aggregates for filling in the pressed steel door frame/hold fast complete all as specified and directed by Engr-in-charge. |
| 36 | S&F of stainless steel wire clothcut to size, 0.36 mm nominal dia wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staple in repairs complete all as specified and directed by Engr-in-charge. |
| 37 | Dismantling floor, hearth or wall tiling including CM bedding but not backing, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-charge. |
| 38 | M&L forVirified Ceramic tiles 10 mm thick (square/ rectangular)polished, area of each tiles not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over 15mm thick screed bed in CM 1:6, complete all as specified and directed by Engr-in-Charge complete all as specified and directed by Engr-in-Charge. |
| 39 | Description all as per ser item No 36.00 here-in-bere but on skirting over vertical surfaces& including 10 mm thick cement mortar 1:4 screed, set and jointed with grey cement slurry and pointed in grout of matching shade of tiles complete all as specified and directed by Engr-in-charge. |
| 40 | Glazed ceramic coloured tiles 450mm x 300mm x 7mm thick as in vertical/Dado surfaces such as skirting dado etc set and jointed in neat cement slurry,jointed in white or coloured cement to matchover and including 10mm thick renderingin cement mortar 1:4 to receive tiles, complete all as specified and directed by Engr-in-charge. |
| 41 | Taking down cement plaster including tiles of any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engr-in-charge. |
| 42 | Rendering 15mm thick in cement mortar 1:4on fair faces of bricks work/concrete surface finished the surface even and smooth (without using extra cement) as on walls complete all as sspecified and directed.Notes :- Plaster shall be carried out upto any height in patches and contractor shall have no claim for height and scaffolding what so ever is required to complete the work. |
| 43 | Rendering 15mm thick in cement mortar 1:6on fair faces of bricks work/concrete surface finished the surface even and smooth(without using extra cement) as on walls complete all as sspecified and directed.Notes :- Plaster shall be carried out upto any height in patches and contractor shall have no claim for height and scaffolding what so ever is required to complete the work. |
| 44 | M&L for applying two coat of oil bond distemper on walls after preparation of newly plastered surfaces over a coat of white primer, complete all as specified and directed by Engr-in-charge. |
| 45 | M&L for applying two coats of cement base paint on walls after preparation of newly plastered surfaces over a coat of white primer, complete all as specified and directed by Engr-in-charge. |
| 46 | M & L two coat of cement base paint over a coat of alkali resistant priming paint over old plastered surfaces of wallincluding preparing surfaces after complete removal of existing treatmentupto 5-10 m height from ground level and at all locations as directed including , scaffolding, cleaning and curing etc, complete all as specified and directed by Engr-in-charge. |
| 47 | Dismantling cast iron work of any description, complete all as specified and directed by Engr-in-Charge. |
| 48 | S&F PVC (SWR) pipes 110 mm bore dia, single socketed in any length with rubber ring joints fixed to walls etc, incl taking down of existing pipes, complete all as specified and directed by Engr-in-charge. |
| 49 | S&F PVC (SWR) 110 mm bore dia junction single, (Single T) equal or unequal provided with access door, complete all as specified and directed by Engr-in-charge. |
| 50 | S&F PVC (SWR) bends 110 mm bore dia provided with access door, complete all as specified and directed by Engr-in-charge. |
| 51 | S&F PVC (SWR) reducers 110 mm bore dia, complete all as specified and directed by Engr-in-charge. |
| 52 | S&F PVC (SWR) vent cowl 110 mm bore dia , complete all as specified and directed by Engr-in-charge. |
| 53 | S&F PVC (SWR) pipes 75 mm bore dia, single socketed in any length with rubber ring joints fixed to walls etc, incl taking down of existing pipes, complete all as specified and directed by Engr-in-charge. |
| 54 | S&F PVC in repair (SWR) pipes 75mm bore pipes signle socketed,in any length with rubber ring joints, laid in trenches or in floor inluding taking down existing old pipes, complete all as specified and directed by Engr-in-charge. |
| 55 | S&F PVC(SWR) 75 mm bore dia junction double, (Double T) equal or unequal provided with access door, complete all as specified and directed by Engr-in-charge. |
| 56 | S&F PVC (SWR) bends 75 mm bore dia provided with access door , complete all as specified and directed by Engr-in-charge. |
| 57 | S&F PVC (SWR) reducers 75 mm bore dia, complete all as specified and directed by Engr-in-charge. |
| 58 | S&F PVC (SWR) vent cowl 75 mm bore dia, complete all as specified and directed by Engr-in-charge. |
| 59 | S&F PVC (SWR) 110 mm bore dia \"P’ trap complete all as specified and directed. |
| 60 | S&F in repair 110mm stack clamps (of PVC/ 50mm by 5mm flat iron and 16mm dia round iron stays), including bolts and nuts and securing ends of stays to wall, complete all as specified and directed by Engr-in-charge. |
| 61 | S&F in repair 75mm stack clamps (of PVC/ 50mm by 5mm flat iron and 16mm dia round iron stays), including bolts and nuts and securing ends of stays to wall, complete all as specified and directed by Engr-in-charge. |
| 62 | S&F in repir stainless steel grating doom 100mm dia with or without hole, complete all as specified and directed by Engr-in-charge. |
| 63 | Taking up or down 15 mm bore steel tubing and connection, removal from site, complete all as specified and directed by Engr-in-charge. |
| 64 | Taking up or down 20 mm bore steel tubing and connection, removal from site, complete all as specified and directed by Engr-in-charge. |
| 65 | Steel tubes, 15 mm bore, galvanised, \"medium grade\" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor including cutting chases for concealed work etc, complete all as specified and directed by Engr-in-charge. |
| 66 | Steel tubes, 20 mm bore, galvanised, \"medium grade\" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor incl cutting chases for concealed work etc, complete all as specified and directed by Engr-in-charge. |
| 67 | S & F PVC connections 15mm size with PTMT nuts of length 450mm, complete all as specified and directed by Engr-in-charge. |
| 68 | 15 mm bore Angle/stop valves in repair fancy type and chromium plated, cast copper alloy,screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or union, complete all as specified and directed by Engr-in-charge. |
| 69 | 10 litre capacity PVC, low level, valveless, syphonic action type flushing cistern in repair, inlet ball valve, float valve, handle andfixing arrangement, 32 mm dia PVC flushing pipe and icluding 15 mm dia 450 mm long PVC connection with PTMT waste coupling, complete all as specified and directed by Engr-in-charge. |
| 70 | S&F vitreous china wash down water closet pan (Pedestal pattern) white, including \"P\" trap in repair and matching plastic sheet cover, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium anodized hinging device and making all connections including health faucet with 1.2mtr hose pipe of ISI marked, complete all as specified and directed by Engr-in-charge. |
| 71 | S&F in repair wash hand basin vitreous china flat black type of size 450 mm x 300 mm white, CI brackets or Pedestal and 32 mm dia PVC waste coupling including cutting for and pining in ends of bracket and connecting up supply pipes, waste or taps , complete all as specified and directed by Engr-in-charge. |
| 72 | Bib taps, in repair (fancy type) cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed by Engr-in-charge. |
| 73 | S&F in repairs Rotational moulded polyethylene water storage tank 1000 Ltrs capacity, ISI marked (cylindrical vertical with closed top), double wall layer construction, hoisted and fixed in position complete all as specified in SSR Part-I, making connections incl 20mm bore ball valve brasswith polyethylene float and fly nut and tank nipples incl dismantling existing water tank of any capacity and removing from site, complete all as specified and directed by Engr-in-charge. |
| 74 | Preparation of new steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chromeprimer, complete all as specified and directed by Engr-in-charge. |
| 75 | S&F in repairshydraulic door closer regulated designation no 3 universel typealmn cast body suitable for door shutters of 851 to 1000mm in width and of wt between 61 to 80 kg cast iron body, complete all as specified and directed by Engr-in-charge. |
| 76 | Dismantling of wall and ceiling boards (Fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and directed by Engr-in-charge. |
| 77 | S&F GI frame work 605x605mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit / tie / purlins etc, at approx 900 mm centre to centre with GI cleat and steel suspenders of appropriate size fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, including provision of 4 mm thick non-asbestos fibre cement board, ISI marked, fixed to snap grid frame works 605 x 605 mm as in ceiling, flat or sloppy as per manufacture\"s instructions, complete all as specified and directed by Engr-in-charge. |
| 78 | S&F Solid PVC wall lining consisting of 5 mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification, complete all as specified and directed by Engr-in-charge. |
| 79 | Provide all materials, labour, tools, and equipment for the supply and installation of EPDM (Ethylene Propylene Diene Monomer) rubber flooring (Multicolour) for children’s play areas. The flooring shall be made of high-quality, non-toxic, UV-resistant EPDM granules mixed with polyurethane binder to form a seamless, elastic, and slip-resistant surface. It shall provide a safe, cushioned, and durable finish suitable for children’s activities and playground use.The surface shall be laid to the specified thickness over an impact-absorbing SBR base layer (if required), on a properly prepared concrete or compacted sub-base. All work shall be carried out in accordance with manufacturer’s specifications and approved samples. |
| 80 | Provide all materials, labour, tools, and equipment required for the supply and installation of radium (photoluminescent) strips (safety measures or any other instructions shall be written as provided by user) for evacuation guidance. The strips shall be made of high-quality, non-radioactive, self-illuminating material capable of glowing in darkness after exposure to ambient light. They shall be fixed along evacuation routes, stair treads, handrails, skirting, and exit pathways to provide visual guidance during power failures or emergency evacuations.The installation shall be carried out as per manufacturer’s specifications and relevant safety standards to ensure maximum visibility and durability. |
| 81 | Material and Labour for chequered ceramic tiles, coloured/designer, 12 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sq M but not exceeding 0.11 Sq M, conforming to IS 4457-2007, on floors, set over and including 15 mm thick screed bed in cement mortar (1:4) and jointed in neat cement slurry and pointed in white cement mixed with pigment to match colour, complete all as specified and directed by Engr-in-charge.Make:- (Johnson \"Endura\"/ Somany \"Durastone\"/ Regency \"Duro\") |
| 82 | M&L Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed by Engr-in-charge. |
| 83 | S&F in repairs stainless steel wire cloth wire cloth , 0.45 mm nominal dia of wire and average width of aperture 1.40mm complete fixed with aluminium wire staples and beads etc, complete all as specified and directed by Engr-in-charge. |
| 84 | S&F in repairs toughened glass bestquality 12 mm thickincluding cutting, rounding, glazing, edges moulding with glazing pin or oil putty etc. and also include necessary fixing arrangement such as corner clamps, bracket and bolt, hinges as required etc. in square not exc .5 sqm in each pane.Notes: No seperate measurement or payment shall be paid to contractor for the requirement of any fixing arrangement such as corner clamps, bracket and bolt, hinges etc. |
| 85 | S & F in repairs 12mm thick toughened glass door make of modiguard, double/ single shutter, including SS pivot of floor door closer, SS corner support, SS handle 600mm long fixed at both sides of both shutter and also including necessary SS accessories, like clampls etc, complete all as specified and directed by Engr-in-charge. |
| 86 | S&Fin repairs Stainless steel tube 20mm bore (Drapery rod/ curtain rails) including PVC coated MS clamps/ holders and decorative attachment at both ends of drapary rod,fixed to opening of door/windows etc, complete all as specified and directed by Engr-in-charge. |
| 87 | Ball brass valves (40mm), (in repair) high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed by Engr-in-charge. |
| 88 | Providing precast cement concrete type B0 1:2:4 (12.5mm graded aggregates) Cement mortar 1:4 louvres and jallies, 25mm thick (measuredsolid), including all mouldings, complete all as specified and directed by Engr-in-charge. |
| 89 | S&F in repairs Double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed, complete all as specified and directed by Engr-in-charge. |
| 90 | S&F in repair 1mm thick plate rack made of stainless steel, 600X750X250mm (Wt not less than 7.5 Kg) including brackets and embedded in brick wall all as specified andas per manufacturers instruction, complete all as specified and directed by Engr-in-charge. |
| 91 | Providing and fixing ACP sheet of approved quality, 3/4/5 mm thick, exterior grade, with office name written in vinyl/acrylic letters, mounted on MS frame, including cutting, finishing, fixing with screws/adhesives, and all accessories, complete all as specified and directed by Engr-in-charge.Note:-The contractor shall ensure installation without any extra cost also cotractor will be responsible for any damages during the working |
| 92 | Writing letters or figures (Block, Roman, Italic or Indian) n.exc 30 cm high, complete all as specified and directed by Engr-in-charge. |
| 93 | S & F in repairs Solar control film 25 micron reflective type sticked to glass panes of any sizes as per instructions of manufacturers complete, including necessary scaffolding etc, complete all as specified and directed by Engr-in-charge. |
| 94 | S & F 10-12mm thick aqua marin shade toughned glass used in structural glazing in facade fixed with frame necessary assessories clip nails screw etc including sacaffolding and safety arrangement arrangement up to 25 meter height, complete all as specified and directed by Engr-in-charge.Note:- The Glasses shall be fixed upto any required height , and the contractor shall ensure installation without any extra cost also cotractor will be responsible for any damages during the working. |
| 95 | S&F Powder coated 50 microns aluminium window sliding type three track (2 glazed & one gauze shutter) aluminium sections weighing not less than 1.67kg/m for frame and 0.55 kg/m for shutter including necessary jointing cleats, glazingcleats, rubber packing , screws, handle, locking arrangement, decogrill and 5.5mm thick plain/tinted glass and aluminium mosquito proof gauge including taking down of old existing steel window and making good disturbed surface of wall, complete all as specified and directed by Engr-in-charge. |