| 1 | Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing) removing servicable tiles to store and rubbish off the premises.. |
| 2 | M&L for Non skid ceramic coloured tiles 7-8 mm thick (Square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors surface set and jointed in neat cement slurry and pointed with whiteor colour cement to matchover and including 15mm thick screed bed in cement mortar 1:4 complete all as specified & directed. |
| 3 | M&L for glazed ceramic tiles, coloured, of size 350 x 250 x 7mm / 450x350x7mm, as in vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in cement mortar 1:3 complete all as specified & directed. |
| 4 | Dismantlingof stone slabs and tiles of any description or thickness in floors & wall, laid bedded & pointed in any mortar complete all as specified and as directed. |
| 5 | M&L for 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms andincluding screed bed of 20mm thick in cement motar (1:4) with pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 6 | Providing edge moulding to 18-20mm thick Granite stone of counter vanities etc. including machine polishing to edge to give high glose finish etc. complete |
| 7 | Taking down chowkhats or frames with shutters (without taking offshutter from the frame ) not exceeding 1.5 Sqm each. |
| 8 | Taking down chowkhats or frames with shutters (without taking offshutter from the frame ) wooden exc 1.5 sqm but not exceeding 4.0 Sqm each. |
| 9 | Taking down shutters of any description exc. 1.00 Sq.m and n.exc. 2.00 Sq.m each. |
| 10 | M & L cutting holes to brick wall built in cement mortar exc half brick but n.exc one bricks for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required. |
| 11 | S & F pressed steel frames of size 105 x 60mm x 1.25 mm thick for door with one or more rebates, including necessary fixing lugs, hinges lock strike plate etc complete all as specified and as directed. |
| 12 | M & L for cement concrete 1:3:6 type(20mm graded aggregate) as in filling holdfasts frames complete all as specified and directed |
| 13 | Material and labour for PCC1:2:4 type B0, (using 12.5 mm graded stone aggregate) as in filling of pressed steel framecomplete all as specified and directed. |
| 14 | M & L for 35 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars),II nd class hard wood,divided into squares with plain, chamfered or rounded, mitered and rebated sash bars in windows, ventilators, etc. are provided with stiles and rails as specified in SSR Part I, Section 8 clause 8.20 (b) any numbers all as specified and as directed. |
| 15 | M & L 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides with lipping frame to match. complete all as specified and directed by EIC. |
| 16 | S&F solid PVC door frameof size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed by EIC. |
| 17 | M & L for Factory Made Solid PVC Moulded Door Shutter with wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded prelaminated PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing. |
| 18 | S & F Powder coatedanodised aluminium (min thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or morerebates including joining cleat for fixing etc. complete all as specified |
| 19 | S&FPowder coated anodised aluminium window and ventilator shutter ,fixed type without sash bars aluminium sections weighing 0.55 kg/m including necessary joining cleats ,glazing clips rubber packing anodised aluminium snap beading , SS screws,anodised aluminium fitting suchas peg stays 150 mm long (1 no),hinges typeB-21 100mm long (2 nos) suitable handle (1no) complete all as specified. |
| 20 | S&F 4mm thick sheet Glass ground or obscured or frosted on one side Ordinary quality and glazing with oil putty in square not exc 0.50 Sqm in each panecomplete all as specified and directed by Engr-in-charge |
| 21 | S&F 4mm thick Figured glass, pin head type and glazing with oil putty in square not exceeding 0.50 Sqm in each pane all as specified and as directed. |
| 22 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm fixed in panels of joineries with stainless steel wire staples complete all as specified and as directed. |
| 23 | S&F 100mm longMS Medium weight Butt hinges cold rolled ,fixed complete all as specified and as directed. |
| 24 | S&F100mm longstain less steel Butt hinges,fixed complete all as specified and as directed. |
| 25 | S&F100mmlong Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed. |
| 26 | S&F150mmlong Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed. |
| 27 | S&F 150 mm aluminiumanodised barrel tower bolts, of extruded section all as specified and directed |
| 28 | S&F 200mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed. |
| 29 | S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedcomplete all as specified and as directed. |
| 30 | S & F 150mm long floor door stopper of aluminium alloy boly and tongue anodised with hard steel spring fixed in floor complete all as specified and as directed. |
| 31 | Taking up or down GI tubing 15 mm bore from trenches/wall including all fittings segregated and stacking the pipe complete all as specified and directed. |
| 32 | Taking up or down GI tubing 20 mm bore from trenches/wall including all fittings segregated and stacking the pipe complete all as specified and directed. |
| 33 | S&F 20mm (OD)CPVC PipeSDR 11 & Plain CPVC SDR 11 Fittings such as Tee, Elbow, nipple and small piece of pipe in floorsor fixed to wall/Ceilingcomplete all as specified and as directed by Engineer-in-Charge |
| 34 | S&F 25mm (OD)CPVC PipeSDR 11 & Plain CPVC SDR 11 Fittings such as Tee, Elbow, nipple and small piece of pipe in floorsor fixed to wall/Ceilingcomplete all as specified and as directed by Engineer-in-Charge |
| 35 | S&Fin repairWHB vitreous china (flat back or angle back type ) with pedestal,including cutting for pinning in ends size 550x400 mm including brackets ,waste pipe ,coupling ,PVC connection pipe and CP pillar tap complete. |
| 36 | S&F in repairs wash down water closet (pedestal pattern) white withplastic water closet seat cover closed pattern incl P or S trap with flat bottom and mild steel chromium plated or aluminised hinging device and excluding flush pipe and flushing cistern complete all as specified and as directed. |
| 37 | M & L cutting holes to brick wall built in cement mortar exc one brick but n.exc two bricks for inserting outlet trap and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required. |
| 38 | S & F in repairPVC valveless syphonic action type low levelflushing cistern 10 Ltr capacity with inlet, ball valve, float and handle incl brackets and flush pipe of polyethylene of low or high density PVC. 32 mm dia all as specified and directed |
| 39 | S&F in repair 600mmx450mm belvelled edge looking mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood with pvc / alluminium frame and fixed to wooden plugs with chromum plated brass screws cup washers. |
| 40 | S&F125 mm size fixed in repairsbrass chromium plated shower roses /shower arms with or without swivel jointsincluding fixing to steel pipe or union of 15mm dia. |
| 41 | S&Fin repair 15mm boreChromium plated fancy type long body bib taps with wall flange, cast copper alloy with round operating knobscrewed down, screwed for iron pipe or for brass ferrulecomplete all as specified & directed |
| 42 | S&F fancy type angle cock of brass chromium plated with long shank screwed for iron pipe and fixedto iron pipe in repairs. |
| 43 | S&F fancy type concealed stop cock with flange of brass chromium plated with long shank screwed for iron pipe and fixedto iron pipe in repairs. |
| 44 | S&F in repairs, CP health faucet with 1.25 mtr tube and hook complete all as specified and directed. |
| 45 | S&F in repair Two way bib cock 15 mm dia chromium plated completefancy type of branded as specified and directed. |
| 46 | S&F in repairs PVC connections 15mm size with PTMT nuts of length 600 mm. |
| 47 | S & F Stainless steel gratings with frame, 127 mm dia,with / without hole for waste pipe connection as in repairs all as specified and as directed. |
| 48 | S & F TubularTowel rail 20mm diaD type 60 cm long fixed between flanges in repairs with brasschromium plated incl all fitting & fixtures complete all as specified |
| 49 | S & F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gm all as specified and as directed. |
| 50 | S & Fcorner glass assembly consists of 5.5mm thick sheet glass shelf 12cm wide fixed with and including chromium plated brass screws and wooden/plastic cleats with CP bracket, guard railing 60cm long, fixed in repairs, all as specified and as directed. |
| 51 | S&F in repairs sinks with draining board made of stainless steel 1 mm thick kitchen with plugs , washers and waste , including bedding in cement mortar on to dwarf wall or including fixing cantiliver brackets, 32mm chromium platedwaste coupling and connecting union to pipe , overall size 915mm x 460 mm & bowl size 410mmx330mm x 160mm complete all as directed. |
| 52 | S&F in repair PVCwaste pipe, 32 mm dia,750mm long, suitable for wash basin &Kitchen sink completeall as specified and as directed |
| 53 | S & F in repairs Kitchen plate rack made of stainless steel 0.8mm thick complete of size 760 x 610 X 254mm, duly assembled and fixed to the wall with wall screws/ fasteners all as specified and as directed.Make :Prayag. Cat no. P-430 or equivalent |
| 54 | S&F PVC (SWR) \"P\" trap suitable for 110mm/100mm bore of pipes all as specified and as directed fixed in repairs. |
| 55 | M&L for PVC (SWR) floor trap75mm dia., plain with grating including jointing with solvent cement all as specified and as directed fixed in repairs. |
| 56 | Taking down rainwater pipes / drain pipes (any size or pattern) including all fittings, heads, shoes, bends etc complete and Supply and fix PVC (SWR) pipes single socketed 110 mm bore fixed in walls/Sunken floor up to 6th floor including necessary scaffolding works, fixing cleats / clampscomplete all as specified and as directed by Engr-in-Charge. |
| 57 | Taking down rainwater pipes / drain pipes (any size or pattern) including all fittings, heads, shoes, bends etc complete and Supply and fix PVC (SWR) pipes single socketed 75 mm bore fixed in walls/Sunken floor up to 6th floor including necessary scaffolding works fixing cleats / clamps complete all as specified and as directed by Engr-in-Charge. |
| 58 | S&F in repairs 50 mm dia High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. |
| 59 | S&F PVC bends of 110 mm dia with access door complete all as specified and directed. |
| 60 | S&F PVC bends of 75 mm dia with access door complete all as specified and directed. |
| 61 | S&F PVC (SWR) branch piece, single(singleY) equel or un equel fixed to 110mm bore of pipes with access door all as specified and as directed. |
| 62 | S&F PVC (SWR) branch piece, double(double Y) equel or un equel fixed to 75mm bore of pipes with access door all as specified and as directed. |
| 63 | S&F PVC T junction singleequal or unequal of 110 mm dia with access door complete all as specified and directed. |
| 64 | S&F PVC T junction singleequal or unequal of 75 mm dia with access door complete all as specified and directed. |
| 65 | S&F PVC (SWR)vent cowl fixed to 110mm bore of pipes all as specified and as directed in repairs. |
| 66 | S&F PVC (SWR)vent cowl fixed to 75mm bore of pipes all as specified and as directed in repairs. |
| 67 | Removing by cutting/up rooting plant/tree under surface of wall/celling including making good the damage portion with cement mortar 1:3 or concrete 1:2:4 type B1using 20 mm graded aggregate complete all as specified and as directed (Note : Approx height of building 10m) |
| 68 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for all as specified and as directed. |
| 69 | M&L for Reinforcedcement concrete 1:2:4, type B1 (using 20mm graded stone aggregates) as in slab supported on wall, beam ,roofs, landing,chajja, shelves etcall as specified and as directed. |
| 70 | M&L for mild steel bars 10 mm dia and over TMT bar, cut to length bent to shape required, includingcranking bending spirally for hooping for columns, hooking ends and binding with and includingmild steel wire (annealed) not less than 0.9mm dia complete all as directed. |
| 71 | M & L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels for flat rough finished surfaces of concrete |
| 72 | M & L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs landing and similar work not exc 200 mm thick, with supports and rough finished surfaces of concrete. |
| 73 | Demolition of Brickwork or stone/boulder masonry, built in Cementmortar/cement lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articlesall as specified and as directed. |
| 74 | Material and labour for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width Type C1, mix 1:3:6 (using 20 mm graded aggregate ) and setting in mortar CM 1:4, complete. |
| 75 | Taking down cement plaster on brick/stone wall and ceiling including raking out joints, hacking for key, scrubbing down with water etc all as specified and as directed. |
| 76 | M&L Rendering15mm thick in cement mortar 1:6 on fair faces ofbrick work or concrete surfaces including finishingeven and smooth. complete all as specified and directed. |
| 77 | M&L, for rendering 10 mm thick in CM 1:3 on concrete surface of ceiling to be finished even and smooth surfaces without using extra cement complete all as specified and directed. |
| 78 | M/L Rendering 15mm thick in CM 1:4 on fair facesof brick / stone or concrete surfaces, mixed with water proofing compound and finishing thesurfaceseven and fair without using extra cementin patch work at various places upto 6th storeyincl necessary formworkcomplete all as specified & directed.(WPC shall be measured and paid separately) |
| 79 | M/L Rendering 10 mm thick in CM 1:4 on fair facesof chajjas, brick / stone or concrete surfaces, mixed with water proofing compound and finishing thesurfaceseven and smooth without using extra cementin patch work at various places upto 6th storeyincl necessary formworkcomplete all as specified & directed.(WPC shall be measured and paid separately) |
| 80 | M & L for Three coat of white wash on newly plastered surfaces of ceilings including necessary preparation of surfaces all as specified and as directed. |
| 81 | M & L for Three coat of white wash on newly plastered surfaces of wall including necessary preparation of surfaces all as specified and as directed. |
| 82 | M&L Preparing the newly plastered surfaces of wall and applying two coat of cement based paint over a coat of primer complete all as specified and directed. |
| 83 | M&L Preparing the newly plastered surfaces of ceiling and applying two coat of cement based paint over a coat ofprimer complete all as specified and directed. |
| 84 | M & L for Complete removal existing tretment on walls washing, rubbing down and stopping of existing treatment applying two coats oil bound emulsiondistemper over a coat of primer match with existing surface all directed. |
| 85 | M & L for preparing previously untreated wood and wood based materials of any description over 10 cm width / girth and applying two coats of Synthetic Enamel paint over one coat of pink primer. |
| 86 | M & L for One coat of synthetic enamel paint on old painted wooden surfaces of any description over 10cm width or girth including necessary preparation of surfaces all as specified and as directed. |
| 87 | M & L for Two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description over 10 cm width or girth including necessary preparation of surfaces all as specified and as directed. |
| 88 | M & L for One coat of synthetic enamel paint on old painted steel surfaces of any description over 10cm width or girth including necessary preparation of surfaces all as specified and as directed. |
| 89 | M & L for Demolition ofCement Concrete (unreinforced) floor/ sunkenfloor of any description and in any position complete all as specified and as directed |
| 90 | M&L for PCC 1:5:10 type E2(using 40 mm graded stone aggregate),in as mass concreet/ sunken floors complete all as specified and directed. |
| 91 | Material and labour for Rendering 15 mm thick on fair concrete surfaces of roofs in CM (1:3) finished even and fair without using extra cement mixed with 3% Integeral Water proofing compound by weight of cement complete all as specified and as directed by Engr-in-charge.(Note: Integral Water proofing compound will be measured and paid for separately). |
| 92 | M&L for wire brushing and cleaning top surface of tiles, cement concrete, including flashings and junction of parapets etcand applying FOSROC Nitoproof 600PF (minimum 0.80mm dft) over a priming coat of Nitoproof WB Primer or equivalent product of Asian paints, M/s Bauchemie / CIPY / SIKA / Pidilite Dr Fixit / Thermax / STP applied as per manufacturer\"s instructions to bottom and full vertical sides of sunken floors and fill it with water and check for dampness and seepage. Incase the slightest indication of seepage / leakage is noticed. the same shall be rectifiedby injection grouting to seal all cracks or application of polymer modified mortar FOSROC Nitobond SBR or equivalent of Asian paints, M/s Bauchemie / CIPY / SIKA / Pidilite Dr Fixit / Thermax / STP admixed with WPC or cementitious crystaaline water proofing compound in the affected area to seal all cracks and microcracks if any;and this shall be doneby contractors at his own costand Apply additional coat of FOSROC Nitoproof 600PF or equivalent Asian paints, M/s Bauchemie / CIPY / SIKA / Pidilite Dr Fixit / Thermax / STP. All junction points of side walls where CI /GI pipesr are passing through shall be sealed with epoxy cement mortarcomplete all as specified. |
| 93 | Supply only liquid water proofing compound. |
| 94 | Taking down carefully aluminum/ point wiring (light, fan, socket or power) complete,conduit and its accessoriesremoving from site and making good disturbed surfaces of walls, floors etc., all as directed. |
| 95 | Taking down existing unserviceable light fittingslight fitings complete by unscrewing from boards/walls and making /buildings and making good disturbed surface to match with existing finish all as directed. |
| 96 | Taking down existing unserviceable sub main wiring including conduit complete, all as directed. |
| 97 | M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes ,metal frame,cover plateof suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc,including all cutting/chases etc in wallsand including continuousearth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specifiedand directed by Engr -in -charge for One light point / one bell point controlled by one, one way switch. |
| 98 | All as per item No.97 above but, One fan point /Exhaust Pointcontrolled by one switch |
| 99 | All as per Item No.97 above butfor One 3 pin, 05 /06 Amps socket outlet point on same board controlled by one, one way 05/06 Amps switch |
| 100 | All as per Item No.97 above butfor One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch |
| 101 | M & L point wiring with 2.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc,including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc,including all cutting/chases etc in wallsand including continuousearth wire of size continuousearth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed by Engr -in -charge for one 15 /16 Amps socket outlet point on independent |
| 102 | M&L for Sub main wiring/power wiring complete with two runs of 2.5 Sqmm, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including suitable size ofrigid non metallic PVC conduit pipe,concealed and accessories on surface wall/floors/ with one run of PVC insulated, 2.5 Sqmm FRLS copper conductor for earth continuity all as specified and as directed.NOTE :- Tworuns of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length. |
| 103 | Supply and fixCeiling rose 3 terminal 5 Amps 230 volts PVC/Polycarbonate, insulated body. |
| 104 | Supply and fixmodular switch 6 Amps 1 way one modulecomplete. |
| 105 | Supply and fixmodular switch of 16 Amps single module complete |
| 106 | Supply and fixmodular socket 6 Amps three pin socket two module complete. |
| 107 | Supply and Fix modularsocket 16 Amps three pin socket four module complete. |
| 108 | S&FLED PC batten light fitting of 4 feet 20 watt, with energy efficient LED and integrated electronic driver of 20W fitting including connecting up with three core flexible copper conductor upto ceiling rose complete all as specified and directed. |
| 109 | S&F LED PC batten light fitting of 2 feet 10 watt, with energy efficient LED and integrated electronic driver of 20W fitting including connecting up with three core flexible copper conductor upto ceiling rose complete all as specified and directed. |
| 110 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers completeall as specified and directed |
| 111 | Taking down ceiling fan/Exhaust fan, sealing the cable ends dismantling the fan blade kept in safe costody complete all as specified. |
| 112 | Taking down geyser upto 2 KW capacity 25 ltrs andkept in safe costody complete all as specified and directed . |
| 113 | Supply and fix electric water heater,storage type ABS body with SS inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessoriessuch as safety valve, thermostate,NRV, connection piece etc. |