| 1 | Excavation in trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable/Pole/ Stays etc getting out in Soft/ Loose any type of soil complete all as specified and directed. |
| 2 | Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils complete all as specified and directed. |
| 3 | Removing Surplus Soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point complete all as specified and directed. |
| 4 | M&L for removing and refixing the old existing Signage board including bracket, signal cable, TV & Bradband cable and music amplifier with cable already installed on old pole and shifting on new decorative pole without damage and checking for serviceability again after refixing complete all as specified and directed. |
| 5 | M&L boaring holes horizontally under Road by trenchless technology without damaging the surface of road as per given/ directed depth below the road surface with the help of boring machine/ or by manual means and laying of DWC Pipe of required size dia for passing of UG cable complete all as specified and directed.Note : DWC pipe laid shall be measured seperately. |
| 6 | S&F Double Wall Corrugated(DWC) HDPE Pipe of size 63 mm Outer Dia x 50 mm Inner Dia Pipe as per new IS-16205 (for electrical cable uses) in protection of UG Cable laid in trenches of following sizes complete all as specified and directed.Note : Cost of pipe coupler with rubber ring is deemed to be included in the unit Quoted Rate. |
| 7 | Taking down/out unserviceable underground LT Cables of any Cross Sectional Area and Connections and joints including Pipes, Bricks, etc of any description laying in trenches or fixed with Walls/Poles, segreating serviceable Pipes, Cables complete all as specified and directed. Note : Earthwork will be measured and paid under appropriate Items. |
| 8 | Supply and laying in repair XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, of cross-sectional area 4 core x 25 Sqmm, laid in trenches/ surface of Wall/in DWC Pipe including Brass Cable Glands Mild Steel Flat Iron Clamps, etc. and testing complete all as specified and directed. |
| 9 | M&L in repair for earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or stee all as shown in electrcal plate No 3 of SSR Part-I connected to continious earth wire or main switch board/ panel etc all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia,light grade GI pipe and watering pipe shall be 20 mm bore medium grade GI pipe including excavation & earth work, PCC pit with RCC cover, charcoal, salt, funnel, GI wire and protection pipe upto 7.5 mtr complete all as specified and directed. |
| 10 | Materials and Labour in repair for earth continuity conductor or main Earthing lead of 4.00 mm dia GI wire, fix to pole, wall or buried in ground or down GI pipe or any type indicated situation for loop earthing/ lighting conductor etc as required with saddles and fixing screws for roof conductors and down conductors above ground level complete all as specified and directed. |
| 11 | Dismantling concrete poles/ struts, any size and transporting to contractor\"s store and stacking all as specified and directed. |
| 12 | Dismantling steel tubular poles/ struts, of any size and transporting to contractor\"s store and stacking all as specified and directed. |
| 13 | Supply, erecting and fixing in true vertical position, Decorative pole 8 meter length, PU painted complete with foundation, anchor bolts, junction boxe and necessary accessories. The pole shall be of decorative type, fabricated in octagonal/ conical/ fluted design as approved by Engr-in-Charge. The pole shall be manufactured from Hot-dip Galvanised Iron conforming to IS 2062 & 4759 grade. The pole shall be continuously tapered design with MS base plate Dia 300 x 300 x 16mm, welded as per IS standards and provided with slotted holes for anchor bolts. The pole shall be of ornamental/ fluted body profile for aesthetic appearance with decorative arm of 0.5m to 1.2m outreach, suitable for LED street light fixtures with optional top crown or ornamental accessories. The pole shall be hot-dip galvanized internally and externally conforming to relevant IS. After galvanizing, the pole shall be finished with UV-resistant outdoor polyster powder coating in approved shade. The pole shall be supplied with a set of 04 Nos anchor bolts of size M16/ M20, complete with nuts, washers and a template plate for accurate installation. The junction box will be provided with 01 no MCB SP 6A-16A capacity and connector/terminal block suitable for 4-core cables with provision of rubber gormets and an in-built lockable box at a convenient height. The pole shall be capable of withstanding wind pressure as per IS 875 (Part-3) complete all as specified and directed. |
| 14 | Single Arm Pole |
| 15 | Four Arm Pole |
| 16 | M&L Cement Concrete 1:4:8 (40mm graded aggregate) as Lean Concrete in Foundation of Poles, Stay Assembly, etc, including Form-work (as/if required), complete all as specified and directed. |
| 17 | M&L Cement Concrete 1:2:4 (20mm graded aggregate) as in Coping of Poles, etc. and finishing the Concrete surfaces Fair and Even including necessary Formwork required at Site(s) complete all as specified and directed. |
| 18 | Supply and fix three core 2.5 sqmm PVC insulated and PVC sheathed stranded copper conductor street light including taking down old unserviceable cable complete all as specified and directed. |
| 19 | Supply & fixing in repair Street light Panel Auto timer switch for auto ON/ OFF of street lights in sheet steel enclosure, including all accessories like contactor, Astronomical timer switch, MCB, pre wired, of 40 Amp, 3 Pole, 230 Volt, Astronomical timer switch, conforming to IS/IEC 61439 & 60529, with in-built short circuit protection and class \"H\" insulation including making all electrical connections, fixing of timer switch box by providing all hardware as required complete all as specified and directed.Make : INDOASIAN Cat no:- TL040AS0 or equivelent in C&S/ Havells. |
| 20 | S&F Thermoplastic cable junction box of size 205mm x 255mm x 112mm, IP 66, halogen free and weather proof with locking arrangement and necessary mounting arrangement on pole with MS clamp, nut, bolt, washer, for out door installation complete with connector terminal for connecting cable, knockouts for cable entry up to the size of 25 Sqmm x 4 core complete all as specified and directed.Note: Contractor shall provide cable lugs and gland of suitable size on site for connecting cable in junction box including taking out ol unserviceable cable junction box any type. |
| 21 | S&F in repair MCB SP 6 to 32 Amps capacity suitable for security light complete all as specified and directed. |
| 22 | Supply & fixing and testing LED street light fitting of 120W capacity, IP66 protected, made up of pressure die cast aluminium, integrated with IP lens for better light dustribution, with total system lumens of 14400, consisting of potted driver with LED drive current not more than 750 MA, CRI >80 with impact and corrosion resistant including taking out old unserviceable LED street light any types complete all as specified and as direcetd. |
| 23 | Supply, fixing and testing of Tricolour Rope Light of length 18 Mtrs in total, inclusive of 6 mtrs length of each colour (Amber, White & Green), Product should comprise of 120 Led\"s per meter & total power consumption of the product should be of 144W delivering 600 Lumens/Watt complete all as specified and as directed. |
| 24 | M&L in repair of PCC interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment coloured, reflective type of approved quality and vibrated with mechanical vibrator having PCC 75mm thick cement concrete type D-2 (1:4:8) (40mm graded stone aggregate) as in bottom foundation and PCC (1:3:6) type C-1 using 20mm graded stone aggregate, 75mm thick as in plinth protection finished fair & even laid in alternative layers n. exc. 2M in length and joints filled with bitumen mastic 1:3 on above and in sideways of bottom foundation with sand filling under floor in foundations including watering and consolidation complete all as specified and directed.Note :- (a) Paver block damaged in dismantling of old security light pole shall be removed from site by contractor with all soil and rubbish material at a distance of more than 50 mtr all as per direction.(b) The disturbed/ damaged path way shall be made good all as per existing colour pattern and style.(c) The new paver block work for making good disturbed surface of pathway around each pole complete shall be measured as one job.(d) Before starting of work design and colour of new paver block shall be get approved in advance from department by contractor and any loss due to lapse in prior approval shall be of contractor\"s responsibility. |
| 25 | Total in Figures |
| 26 | Quoted Amount in Words |