| 1 | Excavation in trenches in soft/ loose soil n.exc 1.5 Mtr deep and n.exc 1.5 mtr wide for laying of HT cable and getting out including dressing/ trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified and directed. |
| 2 | Excavation in trenches not exc 1.50 meter wide not exc 1.50 meter deep in Hard/ dense soil for laying of pipe line and getting out complete all as specified and directed. |
| 3 | All as per Srl item No 1.00 above but exceeding 1.5 Mtr and not exceeding 3 mtr deep, complete all as specified and directed. |
| 4 | Returning, filling, including leveling, watering and well ramming excavated soil in layers n.exc25cm thick in trenches after cable have been laid complete all as specified and directed. |
| 5 | Removing of excavated surplus soil obtained from excavation to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr of the starting point complete all as specified and directed. |
| 6 | Dismantling and taking down old wornt out ACSR conductor of any type and size complete all as specified and directed. |
| 7 | Dismantling & taking down old wornt out/ rusted MS clamps/ crossarms/ channels/ bracket complete with nuts & bolts etc., complete all as specified and directed. |
| 8 | Dismantling & taking down old insulators any type, any size complete all as specified and directed. |
| 9 | Supply, laying, jointing and testing of cable XLPE insulated, screened, PVC bedded ,galvanized steel strip or wire armored heavy duty electric cable with multistranded aluminium conductor, 1100 volts grade, laid in trenches or duct or passing through pipe or fixed to poles walls of size 240 Sqmm 3.5 core confirming to IS : 7098 (Part - 1) laid in trenches, under road or passing through pipes/ducts or fixed to walls/ poles complete with proper thimbles complete all as specified and directed. |
| 10 | Supply, laying, jointing and testing of cable XLPE insulated, screened, PVC bedded ,galvanized steel strip or wire armoured heavy duty electric cable with multistranded aluminium conductor, 1100 volts grade, laid in trenches or duct or passing through pipe or fixed to poles walls of size 185 Sqmm 3.5 core confirming to IS : 7098 (Part - 1) laid in trenches, under road or passing through pipes/ducts or fixed to walls/poles complete with proper thimbles, complete all as specified and directed. |
| 11 | Supply, laying, jointing and testing of cable XLPE insulated, screened, PVC bedded ,galvanized steel strip or wire armoured heavy duty electric cable with multistranded aluminium conductor, 1100 volts grade, laid in trenches or duct or passing through pipe or fixed to poles walls of size 35 Sqmm 3.5 core confirming to IS : 7098 (Part -I) laid in trenches, under road or passing through pipes/ducts or fixed to walls/poles complete with proper thimbles, complete all as specified and directed. |
| 12 | Supply, laying, jointing and testing of cable XLPE insulated, screened, PVC bedded ,galvanized steel strip or wire armoured heavy duty electric cable with multistranded aluminium conductor, 1100 volts grade, laid in trenches or duct or passing through pipe or fixed to poles walls of size 25 Sqmm 4 core confirming to IS : 7098 (Part - 1) laid in trenches, under road or passing through pipes/ducts or fixed to walls/poles complete with proper thimbles, complete all as specified and directed. |
| 13 | Supply, laying, jointing and testing of cable XLPE insulated, screened, PVC bedded ,galvanized steel strip or wire armoured heavy duty electric cable with multistranded aluminium conductor, 1100 volts grade, laid in trenches or duct or passing through pipe or fixed to poles walls of size 16 Sqmm 4 core confirming to IS : 7098 (Part - 1) laid in trenches, under road or passing through pipes/ducts or fixed to walls/poles complete with proper thimbles, complete all as specified and directed. |
| 14 | Supply, laying, jointing and testing of cable XLPE insulated, screened, PVC bedded ,galvanized steel strip or wire armoured heavy duty electric cable with multistranded aluminium conductor, 1100 volts grade, laid in trenches or duct or passing through pipe or fixed to poles walls of size 10 Sqmm 2 core confirming to IS : 7098 (Part - 1) laid in trenches, under road or passing through pipes/ducts or fixed to walls/poles complete with proper thimbles, complete all as specified and directed. |
| 15 | M&L for painting of steel tubular LT poles including removing rusted particles and painting with two coats of synthetic enamel aluminium paint including cross arms, supports, clamps, etc and providing different colour strip up to height 1.5 mtr from from coping including writing pole no.complete all as specified and directed.Note: Colour of paint for stripsand no of strips will be approved by Engr-in Charge. |
| 16 | Supply and fixing in replacement street lightmounting bracket made out of GI pipe 40 mm dia or suitable size light as per requirement Grade not less than with 1.5(90cmx60cm) mtr long in any shapeincluding clamps, nuts, bolts, washers etc and painting with aluminium paint suitable for street light all as directed by Engr in Charge |
| 17 | S&F in replacement ofPVC insulated flexible FR PVC unarmoured cable three core with copper conductor 1.5 Sqmm size 1100 volt grade complete connection complete all as specified and directed. |
| 18 | S&F in replacement of Automatic street light control with infrared sensor based NATURE SWITCH and VOLTAGE MONITORING SYSTEM (VMS) Three phase load of 5 KW for automation of street lights.Nature Switch operation should be based on Natural light Lux level.Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility of min. 4 hrs. to max. 12 hrs.VMS should have adjustable over & under Voltage trip level and protection against phase loss, Neutral loss & Phase reverse incl Power contactors (3 nos of capacity 16 amps per phase each) and incoming (3 nos of capacity 20 amps each)- outgoing MCB(3 nos of capacity 20 amps each)& main load circuit wiring (Copper) of minimum 10 sqmm. The sensor , VSM, Power contactor, MCBs incl connected items should be enclosed in a Pole/ wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP54. The circuit should also have provision for manual operation (i.e. sensor & VMS By-Pass option), complete all as specified and directed.Model Swadeep- 02EC5kW3P-VMS or equivalent in Schneider/ Havells/ Legrand |
| 19 | S&F KIOSK box weather proof made out of PVC including made out of one piece mounted SMC base and door pole mounted hinged door size 300 x 200 x 105mm inside dimension comprising of aluminum bus bar 4 strips for 3 phase and neutral 200 Amp and 1.0 Amp MCB for controlling the street light fitting with necessary MS nuts bolts and washer complete all as specified and directed. |
| 20 | Supply, installation, testing and commissioning outdoor type cubical LT panelin replacement of size not less than 1.2 m x 1.2 m x 0.6 mwith outer shell made out of3.15 mm thick MS sheet and MS angle section 50x50x6mm on PCC 1:2:4 type B-2 platform 60cmabove the ground level and 45cm below the ground level, factory fabricated with front open able, lockable,having pad lock arrangement, louvers and air vent, gasket ‘u’ type for natural flow of air, completed dust & vermin proof suitable for 3 phase 4 wire 415 volt 50 Hz factor fabricated ( Factory approved from CPRI) having modern fabrication followed by powder coated painting having thickness not less than 100 micronsTPN aluminum bus bar 300 Amps insulated with colour coded heat shrinkable and shall be mounted on suitable size ‘F’ class insulators, marking connection with aluminum strip conductor of and general construction to IS-8623 of 1993 comprising of the following:- The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with and comprising of the following:- |
| 21 | (i) Epoxy insulated common aluminium bus bar of capacity 500 Amp TPN each with Color Coding, including aluminium lugs to connect the cable. (ii) MCCB 4 Pole, 415 V, Adjustable type, 350 Amps with breaking capacity 36 KA-01 No (For main Incoming )(ii) MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA-01 No (For Outgoing No.-1 )(iii) MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA-01 No (For Outgoing No.-2 )(iii) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 36 KA-01 No (For Outgoing No.-3 )(iii) On load Changeover Switch 250 A-01 No. (iv) Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No(v) Ammeter 0 - 400 Amps digital type square shape 96mm flush mounted with selector switch and CT\"s 400/5 A - 1 No.(v) Indicator lamp RYB: 01 Set complete |
| 22 | Supply, installation, testing and commissioning factory made, LT bus bar panel board cubical, Outdoor type, floor/ground mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA sheet(Min size 0.6 m x 0.5 m x 0.35 m ), the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seventank phosphate treatment front & back opening type and fixing 2 Nos danger notice plate with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of up to 1/2 mtr height from GL& 1/2 mtr for Below GL in PCC (1:3:6) type C-2 using 40 mm stone aggregatescomprising of following:-The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with and comprising of the following:- |
| 23 | (i) Epoxy insulated common aluminium bus bar of capacity 315 Amp TPN each with Color Coding, including aluminium lugs to connect the cable. (ii) MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 36 KA-01 No (For main Incoming )(iii) Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No(iv) Ammeter 0 - 400 Amps digital type square shape 96mm flush mounted with selector switch and CT\"s 400/5 A - 1 No.(v) Indicator lamp RYB :01 Set complete |
| 24 | Supply, installation, commissioning in replacement of Busbar panel outdoor Step Type Design of size 0.8x0.8x0.5m with DMC insulators locking arrangement MS sheet covering 3.15 mm thick pedestal mounted vermin and weatherproof including four legs of 100 cm long of angle iron 40x40x5mm, front open able door having canopy for protection all surfaces painted with powder coated painting, embedding and including 400 Amp rated aluminium bus bars 4 Nos duly drilled for making connection with nut bolts of suitable size with colour code tape complete with PCC 1:3:6, type C-1, using 20mm graded crushed stone aggregate for foundation for legs and make good electrical connection as specified by EIC.Note: The rate are included with thimbles lugs, nut bolts, PCC foundation and aggregate. |
| 25 | M&L for earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth strip 32x6 mm by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4, type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 15 mm bore “Light grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 40mm bore “light grade” galvanized iron protection pipe for earth strip 32x6 mmup to 7.5 m length, charcoal, common salt, complete all as shown in EP No 1 of SSR 2020 Part-I, connected to test point complete, all as specified and testing on completion, complete all as specified and directed.Note:(i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead up to 7.5 mtr, char coal dust, common salt, porcelain insulator, PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate andwatering pipe, earth lead protection pipe, test point, earth lead up to 7.5 mt . |
| 26 | All as per Srl Item No 23.00 above but with GI wire of 4.0sqmm as earthing lead complete all as specified and directed. |
| 27 | S&F in replacement LED street light fitting 70/ 72 Watt 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with potted driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 28 | M&L for anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed. |
| 29 | S&F in replacement Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9 meters long) including taking down old rusted steel pole/ RCC pole, complete all as specified and directed. |
| 30 | S&F cable jointing kit for 1.1 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 4 core XLPE, armoured, Al conductor cable of size 16 sqmm, complete all as specified and directed. |
| 31 | All as per Srl Item No 28.00 above but for cable of size 25 to 35 sq mm, complete all as specified and directed. |
| 32 | All as per Srl Item No 28.00 above but for cable of size 185 to 240 sq mm 3.5 core, complete all as specified and directed. |
| 33 | All as per Srl Item No 28.00 above but straight through for cable of size 16 sqmm, complete all as specified and directed. |
| 34 | All as per Srl Item No 28.00 above but straight through for cable of size 25-35 sq mm,complete all as specified and directed. |
| 35 | All as per Srl Item No 28.00 above but straight through for cable of size 185-240 sq mm 3.5 core, complete all as specified and directed. |
| 36 | M&L for PCC 1:2:4, type B-1, using 20mm graded stone aggregate for coping pedestal of poles. Including necessary form work fair finished to exposed surface. |
| 37 | M&L for PCC 1:3:6, type C-2, using 40mm graded crushed stone aggregate for foundation of poles and stay assembly complete all as specified and directed. |
| 38 | M&L for PCC 1:4:8, type D-2, using 40mm graded crushed stone aggregate for foundation of poles below 1.5 mtr., complete all as specified and directed. |
| 39 | M&L for PCC 1:1.5:3, type A-1, using 20mm graded course aggregate as in top gap filing of road/path etc., complete all as specified and directed. |
| 40 | Boring of holes under road, pavement, hard standing for layingpipe for crossing cable including getting out, disposal of rubbish off to a distance up to 50 Mtrs for 90/50 mm DWC pipe complete all as specified and directed. |
| 41 | Supply, fixing and laying galvanised pipe 80 mm bore light grade fixed to pole with clamps nuts, bolts and washers or laid under road crossing or fixed to wall complete all as specified and directed. |
| 42 | Dismantlingof stone slabs and tiles of any description or thickness in floors, aprons etc, laid bedded and pointed in any mortarand keeping in safe custody for relaying complete all as specified and directed. |
| 43 | M&L for PCC 1:4:8, 75 mm thick, type D-2, using 40mm graded crushed stone aggregate as in sub base, complete all as specified and directed. |
| 44 | M&L for 30mm thick layer of fine sand, sand filling under floors or in foundation including watering & consolidation complete all as specified and directed. |
| 45 | Labour onlyfor laying of machine pressed precast concrete coloured interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness M-35 Grade complete all as specified and directed. |
| 46 | Supply & laying ofMachine pressed precast concrete coloured interlocking paver block any shape and size or as per existingconforming to IS 15658-2006 of 60 mm thickness M-35 Grade complete all as specified and directed. |
| 47 | M&L for cable route indicator made out of CI plate 100 dia, 8 mm thick, embossed with lettering \"MES LT Cable\", welded or bolted onto 35x35x6mm angle iron, 500 mm long duly painted with anti-corrosive paint in brown colour & including necessary earthwork and excavation, embedded in PCC M15, (Nominal Mix) using 20 nominal size graded crushed stone aggregate of size 400x400x300mm, complete all as specified and directed. |
| 48 | Supply, fixing or layingHDPE (DWC) tubing 50 mm dia in black colour as per IS:16205 part 24 fixing on poles, walls under floors, laying on surface etc as reqd at site including clamps to hold pipe at position complete all as specified and directed by EIC. Note: All items and accessories , bend, joints, nut bolts, clamps for wall fixing as per site requirement etc are incl in quoted rates, complete all as specified and directed. |
| 49 | All as per Srl Item No 46.00 above but for 110 mm dia complete all as specified and directed. |