| 1 | Excavating in trenchesnot exc 1.5 m wide and not exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard / dense soil etc complete all as specified and as directed |
| 2 | Returning, filling in, including spreading, levelling,watering and well ramming in layers not exc 25 cm thick with soil etc complete all as specified and as directed |
| 3 | Removing excavated soil not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting pointetc complete all as specified and as directed |
| 4 | M&L for plain cement concrete(1:4:8) type D-2 using 40 mm graded stone aggregates as in foundations and mass concrete etc complete all as specified and as directed |
| 5 | M&L for Reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in Foundation, including rafts, footings, plinth beam etc complete all as specified and as directed |
| 6 | M&L for Reinforced cement concrete M-25 (desing mix)using 20 mm graded stone aggregates as in slab supported on walls, beam and columns in floors, roofs landing balconies canopies etc complete all asspecified and as directed |
| 7 | M&L for Reinforced cement concrete (M-25) Design Mixusing 20 mm graded stone aggregates as in beam, cantilevers, bressumers, lintels over 1.5 mtr span etc complete all as specified and as directed |
| 8 | M&L forReinforced cement concrete (M-25) design Mix using 20 mm graded stone aggregates as in column, pillars, piers, posts and struts etc complete all as specified and as directed |
| 9 | Supply only Liquid water proofing compound, ISI marked, all as specified and as directed |
| 10 | M&L for Pre-cast cement concrete(1:3:6)type C1 using20 mm graded stone aggregate as in solid block masonryexc. 10 cm in width and setting in cement mortar(1:6)etc complete all as specified and as directed |
| 11 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; verticalwith fair finished flat surfaces of concrete etc complete all as specified and as directed |
| 12 | M&L forFormwork to sides of pillars,posts, struts, piers,columnsand stanchionswith fairfinished square or rectangular flat surfaces of concrete complete all as specified and as directed |
| 13 | M&L for Formwork to soffits and sides of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) with fair finished flat surfaces of concrete etc complete all as specified and as directed |
| 14 | M&L for formwork to sides and soffits of floor or roof beam, beam and haunching, girders, bressummers, lintels cantilevers, shelves including supports, overhangs etc also splays between floor and beam with fair finished flat surfacesetc complete all as specified and as directed |
| 15 | S&F Factory madepressed steel frame of profile size 125 X 60 mm for door with one ore more rebate, made of 1.25 mm thick M S sheet includings necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed |
| 16 | M&L for cement concrete 1:3:6 type C-0 using 12.5mm graded stone aggregateas in hold fast and fillingof pressed steel chowkatetc complete all as specified and as directed |
| 17 | M&L for Mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290-0 or Fe -E-165 etc complete all as specified and as directed |
| 18 | S&FFlush shutters 35mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed |
| 19 | M&L for Preparation of new wood or wood based surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and as directed |
| 20 | S&FFactory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile:), with 2,4 or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm Plain colour PVC Sheet on back face etcwith wood free EPS complete all as specified and as directed |
| 21 | S & F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all asspecified and directed.(Note :- Door frame shall be water proof, termite proof, elegant andshould have excellent screws holding strength to fix hinges and hold doors properly for a long life) |
| 22 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded as specified and directed.(NOTE :Sheet glass/figured glass andwire mesh will be measured and paid separately). |
| 23 | S&FSteel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed (NOTE :Sheet glass/figured glass andwire mesh will be measured and paid separately). |
| 24 | S&FSheet glass 4mm thickofordinary quality and glazing with oil putty or wooden beading to wooden frame or steel framein squares not exc 0.50 sqm in each pane complete all as specified and as directed |
| 25 | S&FFigured glass 4mm thick, pin head type and glazing with oil putty in squares in not exc 0.5 sq.m in each pane etc omplete all as specified and as directed |
| 26 | S&FStainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainles steel wire stapel etc complete all as secified and as directed |
| 27 | S&F Aluminium handle150 mm sizecast type, anodised etc complete all as specified and as directed |
| 28 | S&F Aluminium anodised towerbolt 200 mm long of extruded section etc complete all as specified and as directed |
| 29 | S & FAluminium alloy, anodised, 300 mm longsliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedall as specified and as directed. |
| 30 | S&FButthinges 100mm size, heavy weight, Stainless Steel and fixed with screwscomplete as sepecified and directed |
| 31 | M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips etc complete all as specified and as directed |
| 32 | All as per item No 31 herein before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and as directed |
| 33 | M&L forPlaincement concrete (1:4:8)type D-2using 40 mm graded stone aggregates asin 75 mm thick sub base to flooing etc complete all as specified and as directed |
| 34 | M& L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15 mm thick screed bed in cement mortar (1:6)complete all as specified and as directed |
| 35 | M& L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting/dadoetc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 10 mm thick backing coat in cement mortar (1:3)complete all as specified and as directed |
| 36 | M& L for Non - skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15 mm thick screed bed in CM(1:6) complete all as specified and as directed |
| 37 | M&L forGlazed ceramic coloured tiles 300X450X7mm thick as in skirting / dado, set and jointed in neat cement slurry and pointed in white or colour cement to match over & including backing coat 10 mm thick cement mortar(1:3) complete all as specified and as directed |
| 38 | M&L for rendering5 mm thickcement mortar (1:3) on fair faces of brick work or concreteceiling surface finished even and smooth without using extra cement etc complete all as specified and as directed |
| 39 | M&L for rendering 15 mm thick cement mortar (1:4) on other than fair faces of brick work or concrete surface mixed with water proofing compound as per manufacture instruction finished even and smooth without using extra cement etc complete all as specified and as directed (Notes : WPC shall be measured and paid seperately) |
| 40 | M&L for rendering 10 mm thick cement mortar (1:6) on fair faces of brick work or concrete surfacefinished and smooth without using extra cement etc complete all as specified and as directed |
| 41 | M&L for preparing newly plastered surface of ceiling and applying three coat of white wash etc complete all as specified and as directed |
| 42 | M&L for Preparing new plastered suface of walls and applying two coatsDistemper acrylic emulsion, white or tinted over a coat of self primer etc complete all as specified and as directed |
| 43 | M&L for preparation of newplastered wallsurfaceand applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. etc complete all as specified and as directed |
| 44 | M&L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed |
| 45 | S&FCPVC pipes 20 mm outer dia bore, SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified |
| 46 | S&FCPVC pipes25 mm outer dia bore, SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified |
| 47 | S&FRotational moulded PVC water storage tank 1000ltrs capacity, triple layeredcylindrical vertical type with closed top including inlet, outlet and wash out holes of approved make hoisted and fixed in position all as specified in SSR Part I etc complete all as specified and as directed |
| 48 | S & FBall valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe 25 mm dia of bore complete all as specified and as directed [Minimum weight for 25mm-455gms ] . |
| 49 | S & FGun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe 25 mm dia bore etc complete all as specifieid and as directed |
| 50 | S&F Bibtap fancy type cast copper alloy chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule or fixed for 15 mm dia bore pipe complete all as specified and as directed |
| 51 | S&F Pillar taps fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered `Hot\" or `Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe 15mm diaand fixedall as specified and as directed |
| 52 | S&F stop valves / Angle Stop cock fancy typechromium plated brass cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unionsfixed for 15 mm dia bore pipe complete all as specified and as directed |
| 53 | S & F Towel rail rail, 20mm dia, D type, 60cm long between flanges of brass or chromium plated complete all as specified and as directed. |
| 54 | S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed. |
| 55 | S & F PVC connection 15 mm dia 450mm longwith PTMT nuts ,all as specified and as directed. |
| 56 | S&F Bevelled edge mirror of selected quality of size area exc 0.40 Sqm but ot exc 0.60 sqmmounted on 6 mm thick AC building board with 40mm thick acryic beading etc complete all as specified and as directed |
| 57 | S&F viterous china squatting pan orrisa pattern of size 580X440 mm white with integral foot rest \"P\" trap including connecting to trap and flush pipe anti-symphonage pipe etc complete all as specified and as directed |
| 58 | S&F vitreous china wash down water closet pan (pedestal pattern), white, including fixing bolts, connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc.. including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed |
| 59 | S&F PVC flushing cistern with flush out valve, low level10 Ltr capacity white with inlet ball valve, float, flushing bend & handle including brackets, etc complete all asspecifiedand as directed |
| 60 | S&FVitreous China wash hand basin, white, flat back, size 550x440mm including brackets,PVC waste pipe 610 mm long andPVC connection 15mm dia450 mm long with PTMT nuts etc complete all as specified and as directed |
| 61 | S&FVitreous China bowl urinal flat back, size465 x 355 x 265 mm white (minimum), with grating and union for discharge pipeincluding providing and fixing plugs, beddings urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, grating and Union for discharge pipe 40 mm dia bore waste stainless steel couplingand LDPE pipe 600 mm long complete all as specified and as directed |
| 62 | M&L forGranite 18-20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed |
| 63 | M&L for Screed bed/rendering 10 mm thick in CM (1:4) on fair faces of brick work or concrete surfacemixed with water proofing compound as per manufacture instruction, finishing even & smooth without using extra cementetc complete all as specified and as directed (Notes : WPC shall be measured and paid seperately) |
| 64 | M & L forwater proofing treatmennt over RCC roof slab all as per following specification complete all as specified and directed:-(i)Removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth (ii) Applying compatible primer/bonding bitumen @ 0.40 Litre/Sq m (iii) Applying APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017 , 3mm thick and weighing not less than 3.80kg/Sq m reinforced with non woven polyster/HMHDPE matt black finished overand torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface complete as per manufacturer\"s instructions (iv) Applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sq m |
| 65 | S&F PVC (SWR) Multi floor trap75 mm dia outlet, plain with grating including jointing with solvent cement etc complete all as specified and as directed |
| 66 | S&F PVC (SWR) gully trap 125/110 mm dia, setting and jointing with solvent cement complete all as specified and directed. |
| 67 | S&F PVC (SWR) pipes 110mm dia bore, single socketed in any length with rubber ring joint laid in trenches or in floor complete all as specified and directed |
| 68 | S&F PVC (SWR) pipes 75mm dia bore, single socketed in any length with rubber ring joint laid in trenches or in floor complete all as specified and directed |
| 69 | S&F PVC (SWR) pipes 110mm dia , single socketed in any length with rubber rings joint fixed with wall complete all as specified and directed |
| 70 | S&F PVC (SWR) pipes 75mm dia , single socketed in any length with rubber rings joint fixed with wall complete all as specified and directed |
| 71 | S&F PVC (SWR) bends (any radius) of 110mm dia complete all as specified and directed |
| 72 | S&F PVC (SWR) bends (any radius) of 75mm dia complete all as specified and directed |
| 73 | S&F PVC (SWR) bends (any radius) with access door of 110mm dia complete all as specified and directed |
| 74 | S&F PVC (SWR) bends (any radius) with access door of 75mm dia complete all as specified and directed |
| 75 | S&F PVC (SWR) vent cowls of 110mm dia complete all as specified and directed |
| 76 | S&F PVC (SWR) vent cowls of 75 mm dia complete all as specified and directed |
| 77 | Filling soil under floors Spreading and levelling in well layers not exc 25 cm thick including watering, rammingas required etccomplete all as specified and as directed |
| 78 | M&L for Hard core with broken stone or boulder of gauge not exc 63mm, deposited, spread and levelled in layers not exc 15 cm thick water and rammed to a true surfac etc all as specified and as directed |
| 79 | M&L forPCC 1:3:6, type C-1, using 20 mm graded aggregates as in 75 mm thick plinth protection etc, finished even and smooth without using extra cement complete all as specified including joints filling with sealing compound Grade \"A\" complete all as specified and directed. |
| 80 | Surface excavation not exceeding30 cm deep and averaging 15cm deep and getting out in hard / dense soil etc complete all as specified and as directed |
| 81 | M &L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size andpattern, finishing and sweeping extra sand etc complete all as specified and as directed |
| 82 | M & L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening whereverrequired complete. etc complete all as specified and a as directed |
| 83 | M&L for Preparation New Concrete surface of any description and applying with two coats of synthetic enamel paint over a coat of self primer etc complete all as specified and as directed |
| 84 | Excavating in trenchesnot exc 1.5 m wide andexc 1.5m but not exc 3m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard / dense soil etc complete all as specified and as directed |
| 85 | M&L Pre-cast Cement concrete(1:3:6) type C-1 using20 mm graded stone aggregates as in solid block masonaryexc 10 cm in width and setting in CM(1:4)all as specified and directed. |
| 86 | M&L for PCC (1:2:4) type B-0using 12.50 mm graded stone aggregate as in surface channels and drains complete all as specified and directed. |
| 87 | M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed. |
| 88 | M&L for Plain cement concrete(1:2:4)type B1 using 20 mm graded stone aggregates as in copings, Chajja kerbs, roof padding/staging of water tank etc including necessary form work, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed |
| 89 | M&L for Rendering 10 mm thickCement mortar (1:4) on fair faces of brick / concrete surfaces finished even and smooth without using extra cement complete all as specified and directed |
| 90 | M&L for Precast cement concrete(1:2:4)type B-1 using 20 mm graded stone aggregatesas in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM(1:4) etc complete all as specified and directed |
| 91 | M&L for Plain cement concrete(1:4:8)type D-2 using 40mm graded stone aggregate as in bed to drain pipes including packing under and haunching againstthe sides of pipe150 mm dia bore after they are laid & tested complete all as specified and directed. |
| 92 | M&L for Plain cement concrete(1:4:8)type D-2 using 40mm graded stone aggregate as in bed to drain pipes including packing under and haunching againstthe sides of pipe200 mm dia bore after they are laid & tested complete all as specified and directed. |
| 93 | M&L for Reinforced concrete pipes, class NP-3,150 mm dia bore of pipelaid and jointed complete with collars complete all as specified and directed. |
| 94 | M&L for Reinforced concrete pipes, class NP-3,200mm dia bore of pipelaid and jointed complete with collars complete all as specified and directed |
| 95 | M&L for cutting into existing manholes for connecting new drains, internal dia of pipe 150 mm, making good to pipe and rendering, cutting out existing benching for and foring branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 tye B-1 smooth finished, and re-forming benching as required etc complete all as specified and as directed |
| 96 | M&L for cutting into existing manholes for connecting new drains, internal dia of pipe 200mm, making good to pipe and rendering, cutting out existing benching for and foring branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 tye B-1 smooth finished, and re-forming benching as required etc complete all as specified and as directed |
| 97 | Demolition of cement concreteand paving not exc 15 cm thick (below or above ground level) complete all as specified and as directed. |
| 98 | M & L for Point Wiringwith 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked with accessories includingGI/ MS branded sunken boxes of suitable module concealedon walls including modular frame and cover of suitable modulefixed with cadmium plated iron screws for housing modular typeswitches, switch socket outlets, fan regulators etc., including 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for the following :- |
| 99 | One light point controlled by one switch |
| 100 | One fan/exhaust point controlled by one switch/regulator |
| 101 | One 3 pin socket out let 5 Amps on same board |
| 102 | One 3 pin socket out let 5 Ampson independent boardNote for Item No 98 :-(i) The earth wire for the points in the same circuit can be looped from point to point(ii) Earth wire shall be taken inside the conduit(iii)Cost of terminal box is deemed to be included in the item rate quoted.(iv) Cost of a circuit ofany length of cablefrom DB to any switch/ socket boardin the item rate quoted. |
| 103 | S&FLED batten with luminaire suitable for indoor applications 18/20 Watts capacity, 4 feet longwith extruded aluminiumhousing & integrated LED channel rectangular white arcylic cover complete with all accessories all as specified and directed. |
| 104 | S&F LED batten with luminaire suitable for indoor applications 10 Watts capacity, 2 feet long with polycarbonate housing & integrated LED channel rectangular white arcylic cover complete with all accessories all as specified and directed. |
| 105 | Supply and fix Modular switch 1 way 6A,1 module all as specified and directed. |
| 106 | Supply and fix Modular Socket, 6Amps - 2/3 pin combined 2 module all as specified and directed. |
| 107 | S&F MCB TPN 240 volts 32 Amps C curves complete all as specified and as directed |
| 108 | S&F MCB single pole 240 volts 6 to 32 Amps, C curvescomplete all as specified and as directed |
| 109 | Supply and fix Modular Fan step regulator, 120W - 2 module all as specified and directed. |
| 110 | S&F MCB Distribution boardSPN 8 way, double door type, 240 volts with 200 Amps rated busbaras specified and as directed. |
| 111 | S&F ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed |
| 112 | M&L for earthingwith galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I and as specified or indicated and testing on completion including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia TMT bars reinforced at 100mm centre to centre both ways, funnel with watering pipe wire mesh and lugs, test point complete all as specified and as directed. |
| 113 | S&F LED bldg securitylight fitting30Watts capacity with pressure die cast housing along with prismatic polycarbonate difuser with IP 66protection complete all as specified and as directed. (Make:- Bajaj, Cat No.:- ENXT P 30L WH SY PC SD or Equivalent Makes specified in P S herein after) |
| 114 | S&F Bracket made out of GI tubing medium grade 25 mm bore, approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc and including applying two coats of aluminum paintover a coat of red oxide primer complete all as specified and directed. |
| 115 | S&F Exhaust Fan 225mm Sweep , steel body AC single phase, 230Volts withblade and frame and louver all as specified & directed. |
| 116 | M&L for sand cushioning with a layer of river sand under and above the cable all as per Para 19.75 of SSR Part-I complete all as specified and as directed |
| 117 | Supply & layingsub class burnt \"B\"bricks for cable protection, all as per Para 19.75 of SSR Part-Icomplete all as specified as directed |
| 118 | Supply & laying XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm, 3.5 core laid in trenches/wall all as specified and as directed |
| 119 | S&F GI tubing light grade 40 mm bore with all fitting laid in trenches/walls/Roads for cable protection all as specified and as directed . |
| 120 | S&FGI tubing medium grade 25 mm bore with all fitting laid in trenches/walls/Roads for cable protection complete all as specified and as directed |
| 121 | S&FGI tubing medium grade 20 mm bore with all fitting laid in trenches/walls/Roads for cable protection complete all as specified and as directed |
| 122 | S&FGun metal Gate valve with iron wheel head, screwed both ends for iron pipe 50mm dia and fixedall as specified and as directed |