| 1 | Supply and Laying, testing and commissioning Vacuum Circuit breakerHT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker having rupturing capacity 350 MVA, overload and earth fault protection, ammeter, voltmeter and of rating upto 630 Amp.as per IS specifications,cost Should be deemed to the included formakeingsuitableadjustment with existing VCBcomplete all as specified and directed |
| 2 | Supply and LayingXLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 150 sq. mm and 3 Core as per IS specifications complete all as specified and directed |
| 3 | Supply, laying LT UG XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sq mm 3.5 core as per IS specifications complete all as specified and directed |
| 4 | Supply,install,testing & commissioning of ON LOAD change over switch 415V4 pole ,1600 Amps insheet metal enclosures Indoor type, floor mounted, CRCA, made of sheet steel ,factory made suitable size open onfront side double doorhaving hinges and locking arrangementspowder coated based on MS channel for arrangement of foundation nuts , bolts and washers (Make:Universal Switch gear control/C&S/Neptune/Power system & Control). The DB should be protected with IP 54 in accordance with IEC 60529. The gasket material shall be polyurethane,whilethe material shall beinternally embedded. thesheet metal enclosuresshould beincluding with supported on MS angle of size 60X60X6mm andnot less than 450 mm long, and including making of suitable size foundations as per manufacturer recommendations Complete all as directed at site and to incorporate the following:- |
| 5 | Supply,install,testing & commissioning of voltage Stabilizer(Servo Controlled) 500 KVA for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415V with accuracy ± 2.5% and speed of correction 8 Volts per second complete all as specified and directed |
| 6 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in hard /dense soil for laying/jointing kit/repair of cable and erection of poles complete all as specified and directed |
| 7 | Returning filling in including spreading, leveling watering and well ramming in layers n.exc 25 cm in hard/dense soil complete all as specified and directed |
| 8 | Removing excavated material to a distance n.exc 50 meters and depositing where directed at a level n.exc 1.5 meter above the starting point complte all as specified and directed |
| 9 | M & L for Sand cushioning on under ground cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable complete all as specified and directed.Note : Punned thickness will be measured for payment purpose. |
| 10 | Supply and lay well burnt sub class ‘B’ bricks as mechanicalprotection to under ground cables laying with length of the bricks equal to the width of the trench complete all as specified and directed |
| 11 | Material and labourfor cutting the existing concrete/bituminous road surface width not exceeding 30 cm and making good the surface with 100mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate finished even and fair complete over 75 mm thick PCC 1:4:8 type D2 using 40mm grade stone aggregate over consolidated/rammed earth surface complete all as specified and directed. |
| 12 | Supply and laying of Reinforced concrete pipes, class NP3, laid and jointedsize 300 mm borecomplete with collars with all fittings laid in trenches/road crossing/along the pole for protection of cable complete all as specified and directed. |
| 13 | Supply and lay Electrical rubber mat of size 2x1 meter, 10 mm thick, voltage grade 11 KV complete all as specified and directed. |