| Sl. No. | Item Description |
| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches(modular/non modular), ceiling roses, pendants, regulators, sockets,lamp holder , light fitting etc. and removing materials to store for keeping in safe custody or for taking as credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etcas directed by Engineer-in-Charge. |
| 2 | Taking down old unserviceable tube light fitting of any type from wall/ceiling and refixing the same in the existing or other position after repairing all the defects at site.Note: Spares, including fixing for repair works are are to be included in unit quoted rates and not any claim entertained on this account. |
| 3 | M & L for surface point wiring for one light / fan /exhaust fan points/bell pointscontrolled by one way 5 Amp switch with 1100 volt grade PVC insulated-unsheathed 1.5 Sq mm multi stranded FRLSH copper conductor cable with continuous earth wire of PVC insulated-unsheathed 1.5 Sq mm multi stranded FRLSH copper conductor cable, drawn in & includingPVC casing -N- caping/ surface non metallic medium PVC conduit mediumgrade with fittings (ISI marked) not less than 20 mm size& sunken anodized pressed steel sheet boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover make sheet fixed with brass screw for housing/fixing switches etc complete all as specified and directed. Note : Proper coding to be adopted. |
| 4 | All as per item No. 03 mentioned here- in -before but one 3 pin 5 Amp switch socket outlet on independent boardcomplete all as specified and directed. |
| 5 | All as per item No. 03 mentionedhere- in- before but one 3 pin 5 Amp switch socket outlet on same board with accessoriescomplete all as specified and directed |
| 6 | All as per item No. 03 mentioned here-in-before but one 16A socket point controlled by one way 16A switch on independent board with 2.5 sqmm wires complete all as specified and directed |
| 7 | All as per item No. 03 mentioned here-in-before but one 16A socket/16 A earth plugpoint controlled by one way 16A switch/20 A MCB on independent board with 4.0 sqmm wires complete all as specified and directed |
| 8 | M & L fo point wiring with 1.5 qmm (Nominal area) FRLSH PVC insulatd and unsheathed single core cable 1100 volts grade with stranded copper conductor in existing conduit along with contineous earth wire 1.5 Sqmm FRLSH PVC insulated, unsheathed stranded copper conductor cable and connected to common earth dolly, with and including 1.6mm cadmium plated sunk MS pressed steel terminal boxes with 3.0 mm thick hylym sheet cover ISI marked fixed with brass screw complete with all accessories for one light/fan/bell point controlled by one 5 Amps single pole one way switch complete all as specified and directed. |
| 9 | All as per item No.08 mentionedhere -in -before but one 3 pin 5 Amp switch socket outlet on same board controlled by one, one way 5 Amp piano switch complete all as specified and directed |
| 10 | All as per item No.08 mentionedhere in before but one outlet 5/3 pin 5 Amp switch socket outlet on independent board controlled by one, one way 5 Amp piano switch complete all as specified and directed |
| 11 | All as per item No.08 mentioned here-in-before but one 16A socket point controlled by one way 16A switch on independent board with 2.5 Sqmm wires complete all as specified and directed |
| 12 | M & Lfor point wiring for one light/ fan point/call bell /exhaust fan point controlled by one wayswitch with 1100 volt grade PVC insulated FRLSH 1.5 Sq mm multi stranded copper conductor cable with continuous earth wire of 1.5 Sq mm multi stranded copper conductor cable PVC insulated-unsheathed FRLSH, drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia including clamps, screws gutties/plug etc& sunken anodized pressed sunken boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover make sheet for housing/fixing switches fixed with brass screw complete all as specified and directed. |
| 13 | All as per item No. 12 mentioned here-in-beforebut 1.5 Sq mm for 5 Amp socket outlet on same board with 1.5 Sq mm earth wire complete all as specified and directed. |
| 14 | All as per item No 12 mentioned here-in-before but 1.5 Sq mm for 5 Amp switch socketon independent board with 1.5 Sq mm earth wire complete all as specified and directed. |
| 15 | All as per item No. 12 mentioned here-in-before but one 16A socket point controlled by one way 16A switch on independent board with 2.5 sqmm wires complete all as specified and directed |
| 16 | All as per item No. 12 mentioned here-in-before but one 16A socket/16 A earth plugpoint controlled by one way 16A switch/20 A MCB on independent board with 4.0 sqmm wires complete all as specified and directed |
| 17 | S&Fswitch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified and as directed. |
| 18 | S&F switch piano Flush type, single pole, 16 amp 240 volts, complete all as specified and as directed. |
| 19 | S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed. |
| 20 | S&FSocket outlet 2 in 1, 3 pin, 15/16 Amps, flush type complete all as specified and as directed. |
| 21 | S&F Switch socket combination (SSC) 2 in 1, 3 pin, 5 Amps flush type,universal complete all as specified and as directed. |
| 22 | S&F Switch socket combination (SSC)2 in1, 3 pin,15/16 Amp flushtype,universal complete all as specified and as directed. |
| 23 | S&Fswitch modular single pole one way 6 amp 240 volts,one Module complete all as specified and as directed. |
| 24 | S&F switch modular single pole one way 16 amp 240 volts, oneModule complete all as specified and as directed. |
| 25 | S&FModular socket 6A - 2/3pin combined twomodule complete all as specified and as directed. |
| 26 | S&FModular socket 16A- 2/3pin combined two module complete all as specified and as directed. |
| 27 | S&F Modular Bell Push 6 Amp , One module complete all as specified and as directed. |
| 28 | S&Fbell push flush type 5 amp AC, 230 volts, single polecomplete all as specified and as directed.. |
| 29 | S&F in repairelectric Bell, Ding Dong AC 230 Volts, single pole complete all as specified and as directed. |
| 30 | S&F five steped type modular fan regulator ,120 W, 1/2 module complete all as specified and as directed.. |
| 31 | S&F Stepped type electronic fan regulator on the existing phenolic laminated sheet complete all as specified and as directed. |
| 32 | S&F ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body complete all as specified and as directed.. |
| 33 | S&F in repair Plug top 15A ,240Volt complete all as specified and directed. |
| 34 | S &F building security lights with new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65/66 roadway luminaries with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver type security lights fitting 35 watt capacity LED and including all accessories duly pre-wired, fixing on existing bracket with nuts, bolts & washers as required at site for fixing of security lightson LT pole/ wall completeincluding taking old security lights fitting any type and description complete all as specified and directed. |
| 35 | S&F in repair of bracket made of GI pipelight grade1.2 Mtr long of size 40 mm bore, bend to shape as per site requirement fixed to pole/wall with flat iron clamp size 40mm x 5 mm -02 Nos with suitablebolts, nuts, washers etc includingtwo coats of synthetic enamel aluminium paint over a coat of red oxide primer on exposed surface of mild steel surface complete all as specified and directed. |
| 36 | S&Fin repair decorative gate light LED 15 watt globe (conical shape) made up of high grade unbreakable polycarbon material specified and directed. |
| 37 | S & Fin repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp breaking capacity 10 KA ,\"C\" series complete all as specified and as directed. |
| 38 | S&F in repair of old unserviceable twin core of flexible wire of size 23/0.0076 with PVC medium grade pipe 20mm dia for connection of post top lantern fitting from one junction box to other junction box complete all as specified and directed at site. |
| 39 | S&F in repair of doubledoorfour waysingle poles and neutral (SPN)DBs sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts suitableamps rated busbarand necessary electric cabaleconnection throughsuitable lugs by crimping and making good disturbed area of wall complete all as specified and directed by Engr-in-charge. |
| 40 | S&F in repair of doubledooreightwaysingle poles and neutral (SPN)DBs sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts suitableamps rated busbarand necessary electric cabaleconnection throughsuitable lugs by crimping and making good disturbed area of wall complete all as specified and directed by Engr-in-charge. |
| 41 | S&F in repair of doubledoortwelve waysingle poles and neutral (SPN)DBs sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts suitableamps rated busbarand necessary electric cabaleconnection throughsuitable lugs by crimping and making good disturbed area of wall complete all as specified and directed by Engr-in-charge. |
| 42 | S&F in repair 240V, 10KA\"B\"curve miniature circuit breaker (MCB) of single poles and neutral (SPN) and current carrying capacity 32 Amp with breaking capacity 10 KA,in the DB with connection testing and commissioning complete all as specified and as directed. |
| 43 | S&F in repair 240V, 10KA\"B\" curve miniature circuit breaker (MCB) of single poles & neutral (SPN) and current carrying capacity6 to 32 Amp with breaking capacity 10 KA ,in the MCB DB with connection testing and commissioning complete all as specified and as directed. |
| 44 | S & F in repair MCCB, 4 pole, 415 V, thermal magnetic release setting with 100% ICU, 63 Ampsto 100 amps with breaking capacity 16 KA, duly ISI marked, complete all as specified and as directed. |
| 45 | S&F in repair MCB DB TPN 4 way vertical type with suitable Amps rating 415 V rated copper busbar in sheet steel enclosure, double door type, complete all as specified and as directed. |
| 46 | S&F in repairLED bulb of capacity 10 watts lumen out put (950 lm) length 102 mm, dia 56 mm, base cap B-22,(ISI marked) complete with all accessories (ISI marked) all as specified & directed by Engr-in-Charge. |
| 47 | S&F Inveter LED bulb of capacity12 watts lumen out put (1200) length 140 mm width 70 mm base cap B22 ,3 star,(ISI marked) complete with all accessories base (ISI marked) all as specified & directed by Engr-in-Charge. |
| 48 | S&F Lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (ISI marked) complete all as specified and directed. |
| 49 | S&F in repair LED light fitting 1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 50 | S&F in repair LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engr in Charge. |
| 51 | S&F in repair LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engr in Charge. |
| 52 | S&F in repair round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete |
| 53 | S & F in repair LED luminairs 600mm x 600 mm,35/36 watt,220 voltACrecessed type with high efficiency PMMA diffuser soft free light complete with drivers, holsers, LED lamps suitable roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed. |
| 54 | M & L for sub main wiring with two run single core 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V includingsuitable size PVC casing-N- caping, medium grade ISI marked with all accessories such as tees,elbow,junction box etc.,, as required, fixed on surface of wall along with one run of 6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion including taking down of existing sub main wiring complete all as specified& directed.Note: Two runs of 6 sqmm and one run of 6 sqmm cable and one run of casing -N- capping shall be measured as one RM. |
| 55 | M & Lfor Sub main wiring two single core 6.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and one run of 6.0 SqmmPVC insulated unsheathedFRLSH multi stranded copper conductor cablefor earth wire drawnin & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia, complete and and testing on completion including taking down of existing sub main wiring complete all as specified& directed. Note: Two runs of 6 sqmm and one run of 6 sqmm cable and one run of conduit shall be measured as one RM. |
| 56 | M & L for Sub main wiring two single core 6.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and one run of 6.0 Sqmm PVC insulated unsheathed FRLSH multi stranded copper conductor cable for earth wire drawn in existing surface/recessed PVC conduit complete and testing on completion including taking down of existing sub main wiring complete all as directed. Note: Two runs of 6 sqmm and one run of 6 sqmm cableshall be measured as one RM. |
| 57 | S&F in repair 1100 V grade heavy duty service cable with PVC insulated aluminium conductor served with an inner sheathing of PVCtapeand overall PVCsheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm dia suspension wire one twin core cable flat or circular of size 10 sqmmtaking down of existing service cable completeall as specified and directed |
| 58 | S&F in repair Rigid non-metallic PVC conduit 20mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and such as couplers, lock nuts, saddles, pipe hooks etc.completeall as specified and directed . |
| 59 | S&F in repair of 3mm thick phenolic laminated hylam sheet of size 9\" X 11\" including necessary cutting, drilling holes for fixing of switches, sockets & fan regulators etc as per site requirement and fixing the hylam sheet on existing metal flush box with new brass/GI screws and washers complete all as specified and directed. |
| 60 | S&F in repair of 3mm thick phenolic laminated hylam sheet of size 8\" X 5\" including necessary cutting and drilling holes for fixing of switches, sockets & fan regulators etc as per site requirement and fixing the hylam sheet on existing metal flush box with new brass/GI screws and washers complete all as specified and directed. |
| 61 | S&F in repair of 3mm thick phenolic laminated hylam sheet of size 5\" X 5\" including necessary cutting and drilling holes for fixing of switches, sockets & fan regulators etc as per site requirement and fixing the hylam sheet on existing metal flush box with new brass/GI screws and washers complete all as specified and directed |
| 62 | S & F Starter switch of capacity 25 amps, working on 240 volts AC supply for air conditioner complete all as specified and directed |
| 63 | M & L for earthing complete with Gl electrode 600 mm x 600 mm x 6.00mm thick buried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.50 mtr below normal ground level connected to Gl earth strip 32 mm X 6mm(up to 7.5 mtr length on earth plate) as earthing lead by means of bolts, nuts, check nuts and washer of galvanized iron or steel including excavation and earth work and disposal of surplus soil including 50 mm dia Gl tubing light grade and necessary fitting for protection of Gl strip includinglaying of charcoal, dust and common salt PCC (1:3:6) type C-l( using 20 mm graded crushed stone aggregate) earth pit with 40x40x6mm mild steelangle iron frame & 50mm thick pre cast RCC cover (1:2:4) type B-1 (using 20 mm gradedcrushed stone aggregate) reinforced with 8mm dia TMTbars @ 75mm C/C both way with mild steelhandle 12 mm dia round bars ,10mm thick plastering withcement mortar(1:4) internally and upt0o 150 mm below ground level externally, PGI funnel with wire mesh 20mm dia Gl pipe for watering complete all as shown on electrical plate No.3 of SSR Part -1 2009 and connected in earth testing point including testing cincludingtaking down old/ unserveciable existing earthing& making good disturbed surface of wall ,floors etc.complete all as directed. Notes: -(i)Earth lead & protection pipes length upto & including 7.50 metre.(ii)Earth filling shall be done by vegetable soil.(iii)Soil should be free from stone, boulders, aggregate, gravels etc. (iv)The rate is inclusive of necessary earth work, returning, filling in and removal etc |
| 64 | Taking down defective Split type ACs/Window type AC Units, shifting to work shop, taking out the defective compressor of capacity 1.5 Ton capacity from unit, replacing the compressor with new compressor, cleaning refrigeration system with Carbon Tetra Chloride (CTC) thoroughly, leak testing with refrigerant gas, testing at workshops, shifting to location, re-installing in its original position or as directed as EIC, connecting up all electrical connections, testing and commissioningcomplete all as specified and as directed by Engr-in-charge. Note: Rate quoted is deemed to be inclusive ofcutting, brazing, sealing the refrigeration tubing, replacement of strainer, cost of CTC, refrigerant gas and CO2 etc., required for the job including transportation. Make: Carrier/LG/Samsung/Sriram/Voltas/Kirloskar/Techamsa/ Blue Star. |
| 65 | Taking down defective Split type ACs/Window type AC Units, shifting to work shop, taking out the defective compressor of capacity 2 Ton capacity from unit, replacing the compressor with new compressor, cleaning refrigeration system with Carbon Tetra Chloride (CTC) thoroughly, leak testing with refrigerant gas, testing at workshops, shifting to location, reinstalling in its original position or as directed as EIC, connecting up all electrical connections, testing and commissioningcomplete all as specified and as directed by Engr-in-charge. Note: Rate quoted is deemed to be inclusive ofcutting, brazing, sealing the refrigeration tubing, replacement of strainer, cost of CTC, refrigerant gas and CO2 etc., required for the job including transportation. Make: Carrier/LG/Samsung/Sriram/Voltas/Kirloskar/Techamsa/ Bluestar. |
| 66 | M & L for replacement of rusted body portions of split type AC unit of 1.5/2.0 Ton capacity with same gauge/size materials like MS sheet, iron similar to the existing one by removing existing, foam pad and components and scraping out old paint on complete body, cleaning surface throughly, applying two coats of synthetic enamel paint of approved shade over a coat of red oxide primer, fixing of new foam pad not less than 3mm thick, refixing of all components, testing and installation in original position, connecting up all electrical connections, testing and commissioning all as specified and as directed. |
| 67 | M & L for condenser fan blade set for 1.5/2.0 Ton capacity of any type of ACs, suitable for makes of Carrier/Voltas/Amtrex/BlueStar rotation in the casing testing including taking out the defective condenser fan blade all as specified and as directed. Make: Kirloskar/Crompton/Jyoti/ABB/BCH or equivalent as approved. |
| 68 | Taking out the burnt out fan motor of evaporator unit and rewinding the motor with appropriate gauge copper wire including varnishing and replacement of worn out shaft, bushes, bearings, reassembling, testing and fixing to the split type AC unit of capacity 1.5/2.0 Ton complete all as directed by Engr-in-Charge. |
| 69 | Supply and fix in repair swing motor for ACs suitable for existing size and capacity of 1.5/2 Ton capacity complete all as specified and directed. |
| 70 | M&L for painting of split type AC and window type AC by applying two coats of approved synthetic enamel paint over a coat of red oxide primer for any capacity of ACs including preparation of old surface by complete scrapping and removing of old corroded paint complete all as specified and directed by Engineer-in-charge. |
| 71 | M&L for Single pole contactor for 1.5/2.0 ton capacity of split type ACs including taking down of existing contactor complete all as specified and directed. |
| 72 | M&L for replacement of thermalinsulationfor1.5/2.0 Ton split type ACscomplete all as specified and directed. |
| 73 | M&L for Themal over load relay for 1.5/2.0 Ton capacity of any type of ACs including taking down unserviceable thermal over load relay complete all as specified anddirected. |
| 74 | M &L for Running capacitors of 50/60 mfd suitable for 1.5/2.0 Ton Capacity split type AC/window type AC including taking down existing unserviceable running capacitors complete all as specified and directed. |
| 75 | M&L for Starting Capacitor of 100/120 MFD suitable for 1.5/2.0 Ton Capacity split type AC/Window type AC including taking down old unserviceble staring capacitor complete all as specified and directed. |
| 76 | M & L in repairs for Drain connectionand drain trap for 1.5/2.0 Ton capacity of split type ACs complete all as specified and directed. |
| 77 | S & F in repair wiring kit suitable for 1.5/ 2.0 Ton capacity of split type AC/Window type ACs complete all as specified and directed. |
| 78 | M&L for capillary tube set suitable for 1 5/2.0 ton capacity of split type AC including taking down of existing unserviceable defective capillary tube set all as specified and directed. |
| 79 | M&L for replacement of rusted mild steel stand(size & shape of existing stand) includingapplying two coats of approved synthetic enamel paint over a coat of red oxide primer suitablefor mounting out door unit of split typeAC complete complete all as specified and directed. |
| 80 | M&L for servicing carefully any type of AC of cap 1.5/2.0 TR fromsiteand removing power connection and front PVC grills, air filters, cleaning, washing, removing dirt, cleaning, servicing including chemical wash of cooling coil of indoor cooling unit and condenser coil of out door unit and cleaning refrigeration system with CTC (Carbon Tetra Chloride) thoroughly, leak testing with refrigerant gas and re assembling the dismantled components and fixing to its original position complete all as specified and directed. |
| 81 | M&L for shifting of Split AC of 1.5/2.0 TR capacity including removing indoor cooling machine, copper piping, drain pipe and thermal sleeve, lifting angle with necessary re fixing arrangement on wall surface, copper piping of suitable gauge for suction and delivery with insulation, including re-surfacing to disturbed surface and testing and commissioning all as specified. (Note: The copper pipe,if required will be measured against relevent items in this schedule) |
| 82 | S & F in repair sheet metal enclosures Single pole and neutral (SPN), with a two pin earth plug and socket with one single pole MCB 20-32A Amps, complete all as specified and as directed. |
| 83 | M & L for cleaning / flushing out the refrigeration system thoroughly with CTC, leak testing with CO2 / N2 locating and rectifying the leaks by brazing with silver / copper rod, pressure testing, vaccuminising and charging with refrigerant gas and topping up compressor oil, testing and commissioning of split type ACs/window type ACs of 1.5/2.0 Ton capacity complete all as specified and as directed. Note: Refrigerant gas will be measured and paid separately. |
| 84 | M & L for gas charging with refrigerant gas R-22, R-34 & R-410 in new sealed/eixting unit of compressors ACs/Water cooler/Deep freezer/Refrigerator unit of any type and any size including testing, complete all as specified and as directed by Engineer-in-Charge. |
| 85 | S & F new temperature sensor probes in the main circuit of split type AC including removal /taking down of existingtemperature sensor probes complete all as specified and as specified. |
| 86 | S & F in repair Printed Circuit Board (PCB Board) for any type of AC units suitable for 1.5 TR to 2.0 TR, complete all as specified and as directed by Engineer-in-Charge.Make : Voltas/ Videocon /LG/National aircon/Bluestar/Carrier as approved by GE |
| 87 | S & F in repair remote controller unit suitable for split type ACs/widow type AC unit of 1.5/2.0 Ton capacity complete all as specified and as directed.Make : Voltas/Videocon/LG/National aircon/Bluestar/ Carrier as approved by GE |
| 88 | S & F in repair for PVC drain pipe of 15mm/20 mm dia with suitable clamps on walls and ceiling all as specified and as directed. |
| 89 | S & F in repair cooling coil of 1.5/1/2 ton AC units including necessary welding/brazing of copper pipes line, testing of leakage, complete all as specified and as directed by Engineer-in-charge. |
| 90 | S & F in repair cooling motor of existing /suitable capacity for walk in cooler, complete all as specified and as directed by Engineer-in-charge. |
| 91 | S & F in repair remote sensor of existing /suitable capacity for walk in cooler, complete all as specified and as directed by Engineer-in-charge. |
| 92 | S & F in repair controllerof existing /suitable capacity for walkin cooler, complete all as specified and as directed by Engineer-in-charge. |
| 93 | S & F in repair capacitor of existing /suitable capacity for walk in cooler of capacity 3.6/4.2 mfd complete all as specified and as directed by Engineer-in-charge. |
| 94 | M & L for repairing of cooling coil,cooling fan ,out door motor ,out door condenser coil for walk in cooler complete all as specified and as directed by Engineer-in-charge. Note:Minor spares required for repairing is deemed to be included in the unit quoted rate.& not any claim entertained on this account at later stage. |
| 95 | S & F new air filter for AC of any size including removal /taking down of existingair filter complete all as specified and as directed by Engineer-in-Charge. Make : Kirloskar/Tenacity/Athelete or equivalent as approved by GE |
| 96 | M & L for PVC cable4 Sqmm 3 core unsheathed multi stranded copper conductor including taking down of existing cable complete all as specified and as directed by Engineer-in-Charge. |
| 97 | S & F strainer filter for AC including removal /taking down of existingstrainer filter complete all as specified and as directed by Engineer-in-Charge. Make : Voltas/LG/Godrej/Bluestar/Kirloskar/Carrier or equivalent as approved by GE. |
| 98 | S & F in repair copper pipe as per existing or suitable size/shape including necessary welding/ brazing/ makingthreading required length, complete all as specified and as directed by Engineer-in-charge. |
| 99 | S & F in repair air grill for split AC as existing or suitable size/shape/design & make, complete all as specified and as directed by Engineer-in-charge. Make : Voltas/Videocon/LG/National aircon/Bluestar/Carrier as approved by GE |
| 100 | Taking down unserviceable water cooler from the site and transporting the same for repair,removing the unserviceable burnt sealed unit (compressor) from the water cooler and S&F factory made overhauled compressor duly charged with compressor oil including welding in position and testing on required pressure and transporting the water cooler at site in its original location of capacity40/80 ltr complete all as specified and as directed by Engineer-in-charge.Make –Usha/Arco/Sidhwal.Note: Gas charging,if required shall be measured and paid separately against relevant item. |
| 101 | S & F in replacement of running capacitor (10 mfd) for water cooler 40/80 ltr capacity complete all as specified and as directed by Engineer-in-Charge. |
| 102 | S & F in replacement of starting relay 3 pin for water cooler 40/80 ltrs capacity complete all as specified and as directed by Engineer-in-Charge. . |
| 103 | Taking down old defective over load protector & S&F new over load protector of suitable capacity/size for 40/80 ltr capacity water cooler complete all as specified and as directed by Engineer-in-Charge.Make –Renutral/Techno mech. |
| 104 | S & F in repair starting capacitor of suitable size/capacity for 40/80 ltr capacity water cooler complete all as specified and as directed by Engineer-in-Charge.Make : Asian/Unistar/Arvind. |
| 105 | Taking out old unserviceable internal wiring and rewiring with same guage and size with flexible copper conductor of suitable size with terminal clips etc including screws, washers etc required for fastering with body complete all as specified and as directed by Engineer-in-Charge. |
| 106 | Taking down rusted front and back body mild steel sheet cover and S&F new 2.0 mm thick mild steel plate cover of duly painted to match the existing of water cooler complete all as specified and as directed by Engineer-in-Charge. |
| 107 | S & F in replacement of unserviceable float valve with new polythelene ball suitable for 15mm dia GI pipe complete all as specified and as directed by Engineer-in-Charge. |
| 108 | Taking out old unserviceable 15mm diawater tap and S&F new self closing chromium plated push cock of 15mm dia heavy duty complete all as specified and as directed by Engineer-in-Charge. |
| 109 | Taking out old unserviceable fan motor and S&F new fan motor of suitable size/capacity for existing water cooler 40/80 ltr capacity complete all as specified and as directed by Engineer-in-Charge. |
| 110 | M&L for cleaning of water cooler complete internally and externally including scraping and complete removing of existing treatment/paint, scales and dirt etc.and applying of two coats of synthetic enamelpaint over a coat red oxide primer all as specified and as directed. |
| 111 | Taking down unserviceable refrigerator of capacity 250 Ltr to 310 ltr from the site and transporting the same to work shop for repair/removing unserviceable burnt sealed unit (compressor) and supply and fix factory made overhauled compressor duly changed with compressor oil including welding in position and testing on required pressure and transporting back to its site and fix in original location complete all as specified and directed by Engineer –in-Charge. |
| 112 | Taking down unserviceable refrigerator of capacity 165 ltr to 190 Ltr from the site and transporting the same to work shop for repair/removing unserviceable burnt sealed unit (compressor) and supply and fix factory made overhauled compressor duly changed with compressor oil including welding in position and testing on required pressure and transporting back to its site and fix in original location complete all as specified and directed by Engineer –in-Charge. |
| 113 | S & F in replacement of freezer door (plastic) complete with tension spring as per original complete all as specified and directed by Engineer -in-Charge. |
| 114 | S & F in replacement of unserviceable tray with new as per original complete all as specified and directed by Engineer -in-Charge. |
| 115 | S & F in replacement of fruit/vegetable tray as per original complete all as specified and directed by Engineer -in-Charge. |
| 116 | S & F in replacement of pgmy lamp (bulb) as per the existing complete all as specified and directed by Engineer -in-Charge. |
| 117 | S & F in replacement of door liver (plastic) as per original complete all as specified and directed by Engineer -in-Charge. |
| 118 | S & F in replacement of door magnetic gasket as per original make for any capacity of Refrigerator complete all as specified and directed by Engineer -in-Charge. |
| 119 | S & F in replacement ofice chamber as per original complete all as specified and directed by Engineer -in-Charge. |
| 120 | S & F in replacement ofunserviceable relay PTC single pole for any type and any capacity of refrigerator complete all as specified and directed by Engineer -in-Charge. |
| 121 | S & F in replacement of unserviceable over load protection with new for any type and any capacity of refrigerator complete all as specified and directed by Engineer -in-Charge. |
| 122 | Opening of regrigator of any capacity for servicing and refixing the same after flushing out and removal blockage, brazing replacement of liquid line filter and recharging the regrigation gas R-22 to obtain the desired cooling completeall as specified and directed by Engineer -in-Charge. |
| 123 | M&L for spray painting of refrigerator with synthetic enamel paint after preparation of old surface ofrefrigerator capacity 310/286/165 ltr of any make/model completeall as specified and directed by Engineer -in-Charge. |
| 124 | Taking out deep freezer of any capacity from the site for complete servicing of Deep freezer units by electically disconnecting the units and cleaning the compressor , condenser , piping suction/discharge suction, fan motor, cooling coils, cooler body and connected accessries with the help of blower unit , cleaning the same with water and caustic soda for condenser and piping unit , tighten all nuts , bolts, screws etc checking the door bedding , electrical controls of the cooling units rectify where necessary and refixing in its original site and testing comlete all as specified and directed by Engineer-in-charge |
| 125 | S & F new sealed unit compressor for deep freezer as per existing make and size & capacity as approved by GE complete all as specified and as directed by Engineer-in-charge. |
| 126 | S & F running capacitor 10 mfd including taking out capacitor complete all as specified and as directed by Engineer-in-charge. |
| 127 | S & F in repair fan motor of suitable size/capacity for deep freezer complete all as specified and as directed by Engineer-in-Charge. |
| 128 | S & F in repair relay of suitable size/capacity for deep freezer as per sample complete all as specified and as directed by Engineer-in-Charge. |
| 129 | M & L for body patching including denting at certain place of deep freezer and then spray painting with match of existing finishing complete all as specified and directed by Engineer-in-Charge. |
| 130 | S & F in replacement ofVoltage stablizer digital display type for automatic operation, single phase naturally air cooled indoor type & designed for input variation betweenI/P Correction Range of 140 - 280 volt with output voltage stablized at 230 V with accuracy of + 2.5 % and capacity 5 KVA complete all as specified and as directed.Make –V-Guard,Havells,Bajaj,Usha,Crompton,Khaitan |
| 131 | Disconnecting carefully water and electric connection from storage type water heater of 25/50 Ltr capacity of any make and dismantling for repair by taking out the syphon assembly of thermostat, heating elementand cleaning, de-scaling the inner tank by de-scaling with chemical compound including soldering, brazing the inner tank, if required, re-assembling the geyser after cleaning & servicing including replacement of flexiblecable of size 2.5 sqmm 3 core with copper conductor up to 1.5 mtr long and re-fixing in existing position complete all as specified and directed.Note:-The rate quoted is deemed to include cost of soldering/brazing work and glass wool superior quality, if required at site. |
| 132 | S & F in repairheating element including rubber gasket & washer etc. of capacity 1.5 KW suitable for existing make and shape complete all as specified and directed. |
| 133 | S & F in repair heating element including rubber gasket & washer etc. of capacity 2 KW suitable for existing make and shape complete all as specified and directed. |
| 134 | S & F in repair heating element including rubber gasket & washer etc. of capacity 3 KW suitable for existing make and shape complete all as specified and directed. |
| 135 | S&F Thermostat rod type including rubber/ PVC gasket to be set to a temperature not higher than the range of 70 degree Centigrade suitable for existing geysers of capacity 25 /35/ 50 ltrs including taking down existing unserviceable thermostat complete all as specified and as directed. |
| 136 | S&F Thermostat tail type including rubber/ PVC gasket to be set to a temperature not higher than the range of 70 degree Centigrade suitable for existing geysers of capacity 25 /35/ 50 ltrs including taking down existing unserviceable thermostat complete all as specified and as directed. |
| 137 | Supply only safety valve of suitable size/capacity for geyser chromium plated brass 15 mm dia all as specified and directed. |
| 138 | M&L for preparation of surface of geyser 25/50Ltrs capacity by scrapping and applying one coat of sythetic enamel paint of approved colour including tinkering and welding, if required at site complete all as specified and as directed. |
| 139 | S&F PVC connecting pipe 18\" long with brass adopters for hot and cold water and connecting up with complete for 25 /35/ 50 ltrs capacity Geysers including taking down existing unserviceable PVC connecting pipe complete all as specified and directed. |
| 140 | S&F bottom covers (set of two halves) duly painted made out of Aluminium /MS sheet of 18 SWG suitable for 25 /35/ 50 ltrs capacity Geysers including taking down existing unserviciable bottom covers complete all as specified and as directed. |
| 141 | S&F base assembly complete with inlet, out let, thermostat pipes, drain plug and screws for fixing the element suitable for any make and capacity Geysers complete with nuts, bolts and rubber gasket including taking down existing unserviceable base assembly complete all as specified and as directed. |
| 142 | S &F in replacement inner stainless steel dome of geyser of capacity 25 Ltrs complete as per sample to match original patterns and shape complete all as specified and as directed by the Engineer -in Charge. |
| 143 | S &F in replacement inner stainless steel dome of geyser of capacity 35 Ltrs complete as per sample to match original patterns and shape complete all as specified and as directed by the Engineer -in Charge. |
| 144 | S&F indication lamp of suitable size/capacity for 25/35/50 ltrs capacity Geysers including taking down existing unserviceable indication lamp complete all as specified and as directed. |
| 145 | S & F in repair PVC insulated copper cable of size 2.5 Sqmm3 crore to any capacity geysers as required length complete all as specified and as directed. |
| 146 | S & F in repair Plug Top 15A, 230 Volt, AC complete all as specified and directed by Engineer-in-Charge. |
| 147 | S & Fin repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp breaking capacity 10 KA ,\"C\" series complete all as specified and as directed. |
| 148 | Taking down carefully by disconnecting electrical connection of unserviceable ceiling fans/exhaust fans of any sweep and size from its position at different locations in cantt area and removing the same fan to MES store yard to keep in safe custody for repairing/overhauling and refixing/ re-installation of repaired/serviceable fans (taken from MES store yard) to the different locations in cantt area complete all as directed by Engineer-in-charge. Note : Transportation of ceiling fans/exhaust fans from site location to MES store yard & back( MES store yard tosite location )shall be made through proper issue/receipt voucher duly mentioning by MES rep. |
| 149 | Servicing ceiling fans of 1200mm/1400mm/ any sweep and size for repairing/overhauling by cleaning/greasing/oiling etc. and re-assembling the same after and including replacement of unserviceable spare parts as required. (which shall be measured and paid separately under respective items here-in-after) complete all as directed by Engineer-in-Charge. |
| 150 | Supply only ball bearing SKF 6202/6201/equivalent suitable for 1200/1400 mm sweep ceiling fans complete all as specified. |
| 151 | Supply only Gun Metal bush of suitable size/capacity for 1200/1400 mm sweep ceiling fans complete all as specified. |
| 152 | Servicing exhaust fans of 450 mm /300 mm/225 mm /any sweep and sizefor repairing/ overhauling by cleaning/ greasing/oiling etc. and re-assembling the same after and including replacement of unserviceable spare parts as required. (which shall be measured and paid separately under respective items) complete all as directed by Engineer-in-Charge. |
| 153 | M&L for cutting of existing winding of ceiling fans of 1200 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-charge.Note : Cutting of winding coil of ceiling fans shall only be done in presence of Engineer-in-charge/concerned ground executive. |
| 154 | M&L for cutting of existing winding of ceiling fans of 1400 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-Charge. Note : Cutting of winding coil of ceiling fans shall only be done in presence of Engineer-in-charge/concerned ground executive. |
| 155 | M&L for cutting of existing winding of exhaust fans of 450 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-Charge.Note : Cutting of winding coil of exhaust fans shall only be done in presence of Engineer-in-Charge. |
| 156 | M&L for cutting of existing winding of exhaust fans of 300 mm/250 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-Charge. Note : Cutting of winding coil of exhaust fans shall only be done in presence of Engineer-in-Charge/concerned ground executive. |
| 157 | S &F in repair 2.5 mfd capacity capacitor of suitable for ceiling fans of 1200mm/1400 mm sweep of approved make complete all as specified & directed by Engineer-in-Charge. |
| 158 | S &F in repair 4/6 mfd capacity capacitor of suitable for ceiling fans of 300mm/450 mm sweep of approved make complete all as specified & directed by Engineer-in-Charge. |
| 159 | S &F in repair mild steel clamps of suitable size & shapewith rubber reel, nut bolts with washer and including spliting pin suitable for 1200 mm/1400 mm sweepof ceiling fans complete all as specified & directed. |
| 160 | S &F in repair down rod for hanging of ceiling fan, fabricated /made out of 15mm dia heavy grade mild steel conduit (length of conduitnot less than 550 mm long & wall thickness not less than 1.5mm) with suitable fan clamps duly painted with two coat of synthetic enamel (white shade) paint over a coat of primer complete all as specified & directed. |
| 161 | S &F in repair down rod for hanging of ceiling fan, fabricated /made out of 15mm dia heavy grade mild steel conduit (length of conduitnot less than 1250 mm long & wall thick ness not less than1.5 mm) with suitable fan clamps duly painted with two coat of synthetic enamel (white shade) paint over a coat of primer complete all as specified & directed. |
| 162 | S &F in repair mild steel hooks fabricated/made out of flat iron 50 mm x 6mmincluding nut, bolts (6-8 mm dia & 40 to 50 mm long with spring washer) complete all as specified & directed by Engineer-in-Charge. |
| 163 | S &F in repairPVC flexible wire of size 23/.0076 Sqmm or 0.50 sqmmmulti stranded, twin core, PVC sheathed copper conductor complete all as specified & directed by Engineer-in-Charge. |
| 164 | M&L for preparation of old rusted surface of ceiling fans of any sweep by cleaning to remove only dust etc. and applying one coat of synthetic enamel (whiteshade) paint and marking MES number with non erasable marker pen with black colour complete all as specified & directed by Engineer-in-Charge. |
| 165 | M&L for preparation of old rusted surface of ceiling fans of any sweep by cleaning to remove only dust etc. and applying two coat of synthetic enamel (whiteshade) paint and marking MES number with non erasable marker pen with black colour complete all as specified & directed by Engineer-in-charge. |
| 166 | S & F in repairstepped socket type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and as directed. |
| 167 | S&F louvers for Exhaust Fan of size 250 mm to 450mm sweep steel suitable for existing shape and size including taking down existing unserviceable /rusted louvers complete all as specified and as directed by Engineer in Charge. |
| 168 | S & F in repair blade set of suitable size/capacity for ceiling fan 1200 mm/1400 mm sweep of any make as per site requirement complete all as specified and as directed. |
| 169 | S & F in repair metal blades set of suitable size for exhaust fan 300 mm/450mmsweep any make as per site requirement complete all as specified and as directed. |
| 170 | S & F in repair PVC blades set of suitable size for exhaust fan 300 mm/450mmsweep any make as per site requirementcomplete all as specified and directed. |
| 171 | S & Fin repair for metal fan blades of best quality of suitable size for Desert Cooler of any make and size including taking out/ down unserviceable one, complete all as specified and as directed. |
| 172 | S&F for PVC fan blades of best quality of suitable size for Desert Cooler of any make and size including taking out/ down unserviceable one, complete all as specified and as directed. |
| 173 | S&F in repairfor Front Grill Double Partition type of 20 SWG metal grill, best quality (as approved) of suitable size for Desert Cooler providing making Electric Connection to all accessories as required including taking out/ down unserviceable one, complete all as specified and as directed. |
| 174 | S & F in repair for motor suitable 1/7 HP, 180 watt, 3 speed for Desert Cooler, copper wounded completeand one set of lugs for mounting body including taking out/ down unserviceable one, complete all as specified and as directed. Make: Khaitan(A-029) or equivalent in CG/Blueline |
| 175 | S&F for 15 mm dia Plastic PVC distributor suitable size for Desert Cooler heavy dutywith elbow, Tee, etc. fixed with bolts, nut & washers including taking out/down unserviceable one, complete all as specified and as directed. |
| 176 | S & F Plastic PVC Pipe(ISI mark) of 15mm bore suitable for Desert Cooler, heavy duty, including taking out/down unserviceable one, complete all as specified and as directed. |
| 177 | S&F Selector Switch suitable for Desert Cooler of any make and size including taking out/ down unserviceable one, complete all as specified and as directed. |
| 178 | S&F Submersible water Pump of suitable size/capacity for Desert Cooler including taking out/ down unserviceable one, complete all as specified and as directed. |
| 179 | S & F in replacementcooler standmade out of equal angle iron (size 30 mm x30 mm x 3mm ) with 25 mm cross support between angle frame and both side of front and back stand legs for desert cooler withapplyingone coat of synthetic enamel paint over a coat of red oxide primer on exposed surface of stand complete all as specified and directed. |
| 180 | S&F Grass Wool Pad (as approved) suitable for Desert Cooler, heavy duty and best quality including taking out/ down unserviceable one, complete all as specified and as directed. |
| 181 | M&L preparing old surfaces of Desert Cooler Body by descaling, rubbing, brushing, cleaning and applyingone coat of synthetic enamel paint (as approved) with spray gun machine of outer surface of cooler and inner side of tank with black bituminous paint complete all as specified and as directed. |
| 182 | Excavation in trenches in hard densesoil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient forlaying cables/pipes,foundations, shafts, well, cesspits, manholes etc.complete all as specified and directed. |
| 183 | Removal of surplus excavated spoil not exceeding 50 mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 184 | Returning, filling in including spreading, levelling, watering and well ramming in layers ofnot exceeding 25 cm thickafter the cables & pipes etc. are laid, jointed & testedand foundations complete all as specified and directed by Engineer-in-Charge. |
| 185 | M&L sand filling in cable trenches for cable protection for clean dry sand unwashed including gently punning in a layer of 15 cm and 8 cm (total 23 cm) inthickness all across the laid portion of LT cable in trenches complete all as specified and directed. (Note:-Punned thickness shall only be considered for payment) |
| 186 | M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in kerb/benching/ copingsincluding weathering, slightly rounded or chamfered angle and throating including use & waste of necessary form worketc complete all as specified and directed |
| 187 | M&L for plain cement concrete 1:3:6 ,type C-2(using 40 mm gradedcrushed stone aggregate) as in sub base of flooring, foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed. |
| 188 | M&L for plain cement concrete 1:4:8 ,type D-2(using 40 mm gradedcrushed stone aggregate) as in sub base of flooring, foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed. |
| 189 | Supplying and laying old size sub class “B” bricks kiln brunt, neatly laid adjacent to each other with axis of bricks perpendicular to the axis of cable for cable protection complete all as specified and directed. |
| 190 | Disconnecting & removing 1100 volt grade XLPE /PVC armoured electric power cable(heavy duty) with standard aluminium conductor,1100 Voltsgrade of cross sectional area 10 Sq mm to 16 Sq mm any core from the trenches ,pole,Panels,DBs etc carefully and relaying the same with same location without any damage to the cableby excavation in trenches carefully as per standard procedure including excavation, RFR, removing of excavated soil, connecting & testing complete all as specified and directed by Engineer-in Charge. (Note: sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.) |
| 191 | Disconnecting & removing 1100 volt grade XLPE /PVC armoured electric power cable(heavy duty) with standard aluminium conductor,1100 Voltsgrade of cross sectional area 20 Sq mm to 50 Sq mm any core from the trenches ,pole,Panels,DBs etc carefully and relaying the same with same location without any damage to the cableby excavation in trenches carefully as per standard procedure including excavation, RFR, removing of excavated soil, connecting & testing complete all as specified and directed by Engineer-in Charge. (Note: sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.) |
| 192 | Disconnecting & removing 1100 volt grade XLPE /PVC armoured electric power cable(heavy duty) with standard aluminium conductor,1100 Voltsgrade of cross sectional area 70 Sq mm to 95 Sq mm any core from the trenches ,pole,Panels,DBs etc carefully and relaying the same with same location without any damage to the cableby excavation in trenches carefully as per standard procedure including excavation, RFR, removing of excavated soil, connecting & testing complete all as specified and directed by Engineer-in Charge. (Note: sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.) |
| 193 | Disconnecting & removing 1100 volt grade XLPE /PVC armoured electric power cable(heavy duty) with standard aluminium conductor,1100 Voltsgrade of cross sectional area120 Sq mm any core from the trenches ,pole,Panels,DBs etc carefully and relaying the same with same location without any damage to the cableby excavation in trenches carefully as per standard procedure including excavation, RFR, removing of excavated soil, connecting & testing complete all as specified and directed by Engineer-in Charge. (Note: sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.) |
| 194 | Disconnecting & removing 1100 volt grade XLPE /PVC armoured electric power cable(heavy duty) with standard aluminium conductor,1100 Voltsgrade of any cross sectional area / core from the trenches ,pole,Panels,DBs etc carefully and relaying the same with same location without any damage to the cableby excavation in trenches carefully as per standard procedure including excavation, RFR, removing of excavated soil, connecting & testing complete all as specified and directed by Engineer-in Charge. (Note: sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.) |
| 195 | Supply, laying/fixing/passing through pipe , jointing & testing LT under ground cableXLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor, 1100 Voltsgrade of cross sectional area 120 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed.(Note: Excavation ,earth work ,sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.) |
| 196 | Supply, laying/fixing/passing through pipe , jointing & testing LT under ground cableXLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Voltsgrade of cross sectional area 95 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed.(Note: Excavation ,earth work ,sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.) |
| 197 | Supply, laying/fixing/passing through pipe , jointing & testing LT under ground cableXLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Voltsgrade of cross sectional area 70 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed.(Note: Excavation ,earth work ,sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.) |
| 198 | Supply, laying/fixing/passing through pipe , jointing & testing LT under ground cableXLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Voltsgrade of cross sectional area 50 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed.(Note: Excavation ,earth work ,sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.) |
| 199 | Supply, laying/fixing/passing through pipe , jointing & testing LT under ground cableXLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Voltsgrade of cross sectional area35 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed.(Note: Excavation ,earth work ,sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.) |
| 200 | Supply, laying/fixing/passing through pipe , jointing & testing LT under ground cableXLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Voltsgrade of cross sectional area 25 Sq mm 4.0 core including taking down old unserveciable cable complete all as specified and directed.(Note: Excavation ,earth work ,sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.) |
| 201 | Supply, laying/fixing/passing through pipe , jointing & testing LT under ground cableXLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Voltsgrade of cross sectional area 16 Sq mm 4.0 core including taking down old unserveciable cable complete all as specified and directed.(Note: Excavation ,earth work ,sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.) |
| 202 | Supply, laying/fixing/passing through pipe , jointing & testing LT under ground cableXLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Voltsgrade of cross sectional area 10 Sq mm 4.0 core including taking down old unserveciable cable complete all as specified and directed.(Note: Excavation ,earth work ,sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.) |
| 203 | Supplying and fixing as in replacement MCCBfour pole 63 amps 415 volt , 50 Hz breaking capacity not less than 16 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge. |
| 204 | Supplying and fixing as in replacement MCCBfour pole 100 amps 415 volt , 50 Hz breaking capacity not less than25 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge. |
| 205 | Supplying and fixing as in replacement MCCBfour pole 160 amps 415 volt , 50 Hz breaking capacity not less than25 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge. |
| 206 | Supplying and fixing as in replacement MCCBfour pole 200 amps 415 volt , 50 Hz breaking capacity not less than25 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge. |
| 207 | Supplying and fixing as in replacement MCCBfour pole 250 amps 415 volt , 50 Hz breaking capacity not less than 25 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge. |
| 208 | Supplying and fixing as in replacement MCCBfour pole 315 amps 415 volt , 50 Hz breaking capacity not less than 36 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge. |
| 209 | Supplying and fixing as in replacement MCCBfour pole 400 amps 415 volt , 50 Hz breaking capacity not less than36 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge. |
| 210 | Supplying and fixing as in replacement MCCBfour pole 630 amps 415 volt , 50 Hz breaking capacity not less than36 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge. |
| 211 | Dismentlingold and unserveciable stay assembly completecomprising of stay clamp, stay wire, stay insulator, stay grip, thimble, bow, stay rod 16 mm dia and stay plate etc including breaking of cement concretecomplete all as specified and as directed. |
| 212 | M&L for stay assembly complete with accessories as shown in electrical plate No 1 (Loop type insulator, stay clamps excavation and concrete measured separately), stay rod of size 20 mm dia complete all specified and directed . |
| 213 | Supply and fixing in repairs loop type insulators, vitreous porcelain, white, brown or greeen of large size, with overall dimensions 140 mm, clearance of hole 25.5 mm complete all as specified and directed. Make: Bengal Potteries/ Jayashree/ Mysore Porcelain/ Jaipuria/ Bhel/ Southern Insulators/ WS Insulators. |
| 214 | Dismantling old and unserviciable prestressed concrete poles/steel tubular poles of any type including breaking cement concrete complete and site clearance . |
| 215 | Supply and erection of steel tubular pole swaged type 410-SP -31 (09.0 mtr long pole) swan neck type complete conforming to IS: 2713 complete with mild steel base plate, finial taper plugpole cap, mild steel bolt, nuts and screws,painting of pole externally with one coat of black bituminous paint (upto planting depth) and remain exterior portion of the pole shall be painted with two coats of aluminium paint over a coat of primer with blue & white strip upto 1.20 m height above GL and all as specified and directedwith two coat of aluminum paint over a coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 5 Nos with yellow and black paint of radium/photosinthetic paint alternately on external surface above base / copingr upto the height of 1.5mtrabove plinth block,writing letter or figures (Block Roman) with thick synthetic enamel paint of approved shade not exceeding 5 cm height including numbering of pole, Paintingcoping with two coats of cement based paint etc complete all as specified and directed.NOTE : (i)All excavation and earthwork ,PCC shall be measured and paid separately under respective items of BOQ. (ii) Manufacture\"s test certificatefor pole shall be produced before execution work. |
| 216 | M&L for painting to existing steel tubular/concrete LT poles, 8.5m/9m/9.5m long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality dust proof and weather proof of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint of radium/photosinthetic paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers with bold letters with black and white paint after painting complete all as specific and asdirected. |
| 217 | Supply and laying GI pipe 80 mm bore light grade with fitting for cable protection at road crossing/under concreteincluding taking down of old one complete all as specific and asdirected. |
| 218 | Supply and laying GI pipe 50 mm bore light grade with fitting for cable protection at road crossing/under concreteincluding taking down of old one complete all as specific and asdirected. |
| 219 | Supply and laying GI pipe 40 mm bore light grade with fitting for cable protection at road crossing/under concreteincluding taking down of old one complete all as specific and asdirected. |
| 220 | S & F in repair ACSR (Aluminium conductor, steel reinforced)conductor of(weasel) 6/1 X 2.59 mm, streching properly on insulators and binding with aluminium binding wires, jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between span etc complete all as specified and as directed by Engineer-in-charge |
| 221 | S & F in repair Aluminium thimbles of size 16 Sq mm to 35 Sqmm of 3.5 core /4 core and including removing burnt thimbles from existing XLPE Cables & cable made to suitable for fixing new thimbles complete all as specified and directed. |
| 222 | S & F in repairAluminium thimbles of size 50 Sq mm to 95 Sqmm of 3.5 core /4 core and including removing burnt thimbles from existing XLPE cables & cable made to suitable for fixing new thimbles complete all as specified and directed. |
| 223 | S & F in repairAluminium thimbles of size 120 Sq mm to 185 Sqmm of 3.5core/4 core and including removing burnt thimbles from existing XLPE Cables & cable made to suitable for fixing new thimbles complete all as specified and directed. |
| 224 | M&L for Pin type Porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade including dismantling /disconnecting & taking down of existinginsulaters of any size & capacity complete all as specified and directed. |
| 225 | M & L forshackletype porcelain, vitreous, white, brown or green Two-in-series\" assembly for tension with tension clamps for conductors, working pressure 1100 volts insulator65 mm dia X 31 mm high X 20mm holeball and socket type working pressure 1100 volts gradeincluding dismantling /disconnecting & taking down of existinginsulaters of any size & capacity complete all as specified and directed. |
| 226 | S & F in repair cross arms bracing supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminum paint complete all as specified and directed. |
| 227 | Material and labour for Fibre LT over head line seperators suitable size for 4 wires fixing on LT OH lines including dismantling of old damaged/ Un-serviceable LT line spacers of any type complete all as specified anddirected. |
| 228 | Material and labour for Fibre LT over head line seperators suitable size for 2 wires fixing on LT OH lines including dismantling of old damaged/ Un-serviceable LT line spacers of any type complete all as specified anddirected. |
| 229 | Supply and fix, in replacementt Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size 20 cm x 15cm for LT complele all as specified and as directed. |
| 230 | Cutting branches /plants / bushes obstructing at over head LT/HT line including cleaning /levelling / cutting of undue surfaces & disposal ofmaterials upto a distance not exceeding 50m complete all as specified and directed by Engineer-in-Charge. |
| 231 | M&L for Earthing complete with GIearth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth wire of size 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I connected to earthing testing point all as specified and directed including excavation and connected earth work in hard/dense soil, PCC 1:3:6 ,type C-1(using 20 mm graded crushed stone aggregate ) as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm dia bore GI light grade pipe as earth lead protection pipe, 50 mm thick pre-cast RCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) as incover slab of size 300 mm x300 mm x 50mm as earth pit cover slab with & including 8 mm dia TMT bars @ 100 mm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer, charcoal and testing also including taking down of old /unserveciable earthing on completioncomplete all as specified and directed. Note: (i) Earth wire/ stripand its protection pipe up to and including 7.5 mtr only from the top of earth electrode. (ii) Rate quoted deemed to be included excavation and earth work in any type of soil with PCCin pit PCC Cover & other arrangement complete all as directed. |
| 232 | Repair/ Maintenance of any type and any size of LT Panel board by removing all internal parts, tinkering the metal parts and replacing fully corroded sheet metal parts like base plate, top plate, front cover etc with appropriate gauges of MS sheet including bending to match with the existing size, welding brazing and assembling including replacing all nuts & bolts in MCBs and proper legging in cable and control wire, sheet metal screws and painting the complete body with two coat of synthetic enamel paint over a coat of Zinc chrome primer and assembling bus bar in separate colour code, Post top insulators, Voltmeter, Amp meter & selector switch and other connected items complete all as specified and directed. (Note:- MS sheets, Al busbar, Post top insulators, Amp & Volt meter, Selector Switches are measured and paid separately as supply only) |
| 233 | Supply only 3.15 mm thick mild steel sheetalongwith one coat of red oxide primer with help of spary gun machine complete all as specfied and directed. |
| 234 | Supply onlyaluminium bus bar of different size and different capacity, as per site requirement and as directed by Engineer-in-Charge including PVC insulating materials and cutting, welding as required, making holes and fixed in position in replacementt (taking down old bus bar) complete all as specified and as directed. |
| 235 | S& F in repair of LCD multi functional metre 50 to 55 VAC capacity three phase square type complete all as specified and as directed. |
| 236 | Supply only selector switch for RY, YB & BR Phases complete all as specified and as directed. |
| 237 | Supply only LED indication Lamp (Red) complete all as specified and as directed. |
| 238 | Supply onlyLED indication Lamp (Yellow) complete all as specified and as directed. |
| 239 | Supply onlyLED indication Lamp (Blue) complete all as specified and as directed. |
| 240 | M & L for removing of damaged steel structure base frame of LT panel board and fabricating new steel structure base frame with size of existing frame equal angle of size 50 mm X 50 mm X 6 mm thick and screwing with existing panel board including two coat of synthetic enamel paint over a coat of red oxide primer with preparation of surface complete all as specified and directed. |
| 241 | Removing wild grass, vegetation, creeper etc around LT panel/ installations, climbing up towards poles and stay assembly including cleaning bottom surface of pole, stay assembly of area not less than 1m x 1m by surface dressing not exceeding 0.5 m deep in soft/loose soil complete all as specified and directed by Engr-in-Charge. |
| 242 | S&F replacement of LT bus bar chamber box of minimum size 70 cm x 50 cm x 30 cm outdoor type double door/front door front/rear opening type suitable for 415 volt 3 phase, 4 wire (100% neutral), 50Hz supply system Box made out of 3.15mm thick (outer) & 2mm thick (innder compartment door) CRCA sheet factory made weather proof, dust vermin proof and vermin proof duly powder coated with 04 Nos, copper bus bar 100 Amps rated ,40 cm each (each bus bar having 04 Nos of nuts, bolts, washer) horizontally place in insulator suitable for lockable door arangement complete with inter connctions with copper solid strips, bus bar chamber having 4 nos legs 45cm long of 40 mm x 40 mm x 6 mm angle iron, 15 cm long grouted in PCC1:2:4, type B-1 (using 20 mm graded crushed stone aggregates)and 30 cm clear space from complete all as specified and directed. |
| 243 | S&F in replacement of off load changeover switch 415 volt in sheet metal encloser 4 pole of capacity 200 Amp complete all as specified and directed. |
| 244 | Disconnection of electric connection from DG set of any description and in any position, for servicing, taking out & removing unserviceable/defective parts/spares, cleaning, servicing, oiling and greasing of necessary parts, refixing the serviceable parts in position after servicing, replacement of unserviceable parts including draining-out of existing engine oil and filling new engine oil of same grade and filters, refixing of all accessories and testing on full load complete all as specified and directed for following capacity of DG sets :- |
| 245 | (a) 12.5 KVA to 63 KVA 3 phase 50 Hz |
| 246 | (b) 82.5KVAto 125 KVA 3 phase 50 HZ |
| 247 | (c) 250 KVA, 3 phase 50 HZ NOTE for Srl item No 245 (a),246(b) & 247(c) :- (i) The quoted rates of the schedule items includes for re-fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid separately under relevant items of Sch `A’ as `Supply only‘ to the extent covered under the relevant supply only items here-in- after but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, seal, locking nuts, small springs, screws/gaskets/ packing /studs etc. (ii) Engine oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly for checking serviceability including cleaning of oil sump by pouring kerosene oil all as directed by the Engineer-in-Charge. (iii) Fresh engine oil replaced for DG sets shall be supply and filling by the contractor and shall be measured and paid separately under relevent item of Sch ‘A’ . However, cost of filling is deemed to be included under the rates quoted for above item. |
| 248 | Supply only the following parts of DG set of capacity12.5 KVA to 63 KVA :- |
| 249 | (a) Fuel filter element. |
| 250 | (b) Oil Filter element . |
| 251 | (c) Air Filter. |
| 252 | (d) By pass filter. |
| 253 | (e) Fan belt. |
| 254 | (f) Radiator hose pipe of suitable size. |
| 255 | Supply only the following parts of DG set ofcapacity 82.5KVA to 125 KVA:- |
| 256 | (a) Fuel filter element. |
| 257 | (b) Oil Filter element. |
| 258 | (c) Air Filter. |
| 259 | (d) By pass filter. |
| 260 | (e) Fan belt. |
| 261 | (f) Radiator hose pipe of suitable size. |
| 262 | (g) V-belt BX-40. |
| 263 | (h) V-belt AVX 3/1562. |
| 264 | Supply only the following parts of DG set of 250 KVA capacity:- |
| 265 | (a) Fuel filter element. |
| 266 | (b) Oil Filter element. |
| 267 | (c) Air Filter. |
| 268 | (d) By pass filter. |
| 269 | (e) Fan belt. |
| 270 | (f) Radiator hose pipe of suitable size . |
| 271 | Supply and filling / top-up coolant for DG set of any capacity all as specified and directed.Make : GULF / MICO /Castrol |
| 272 | Supply and filling engine oil of DG set of grade 20 W 40 after Servicingcomplete all as specified.Make :- Servo, Veedol & elf |
| 273 | Checking/Servicing of DG Set battery 12 volt, 92/ 180 AH cleaning of battery terminals by hot water and applying petrolium jelly over battery terminals, water level checking including topping up with distilled water complete all as specified and directed (Note - Bettery terminal, Battery cable and distilled water will be measured and paid separatly) |
| 274 | Supply and fixing following items for battery 92/180 AH 12 Volts :- |
| 275 | (a) Heavy duty brass battery terminal |
| 276 | (b) Battery lead 70 Sqmm multistandard, single core, copper conductor |
| 277 | (c) Distilled Water of approved make |
| 278 | Taking down & repairs of radiator assyof DG set of capacity 12.5 KVA to 63 KVA from engine mounting by opening water hose and nut bolt cleaning of radiator inside and out side with anti rust solution, checking the radiator by filling water and repairing for any leakage by brazing the radiator and ensure for no leakage Re- fixing the radiator at place including transportation for repair to workshop or site all as directed. |
| 279 | Taking down & repairs of radiator assyof DG set of capacity 82.5 KVA to 125 KVA from engine mounting by opening water hose and nut bolt cleaning of radiator inside and out side with anti rust solution, checking the radiator by filling water and repairing for any leakage by brazing the radiator and ensure for no leakage Re- fixing the radiator at place including transportation for repair to workshop or site all as directed. |
| 280 | Dismantling & repairs of the fuel injection pump from engine block of DG set of 30 KVA to 63 KVA disconnecting all fuel inlet and outlet lines, disconnecting the drive for carrying out repairs/ replacements including calibration, re assembling of FIP and fixing back in position after repair / replacement of unserviceable parts all as directed. Note :- 1. Calibration of FIP complete shall be got done from manufacturer authorized dealer/ workshop to entire satisfaction of Engineer- in- charge.2. Shifting and loading/Unloading of FIP and transporting for repair in workshop at Ramgarh/ Ranchi city from existing location/site is including in deemed rate. |
| 281 | M&L for Repairs/ maint including taking down unserviceable self starter 12 Volts for DG sets, servicing and replacement of old carbon brushes,bearing and contact blades etc and refixing after servicing and making serviceable with replacement of unsv parts complete all as specified and as directed. (NOTE : Bearing of alternator will be measured and paid separately) |
| 282 | Taking down unserviceable self starter 24 Volts for DG sets, serviceing and replacement of old carbon brushes, bearing and contact blades etc and refixing after servicing and making serviceable with replacement of unsv parts complete all as specified and as directed. (NOTE : Bearing of alternator will be measured and paid separately) |
| 283 | Taking down unserviceable alternator suitable for 12 Volts for DG sets, serviceing and replacement of old carbon brushes, bearing and contact blades etc and refixing after servicing and replacement of unsv parts. (NOTE : Bearing of alternator will be measured and paid separately) |
| 284 | Dismantling & repairs of the fuel injection pump from engine block of DG set of 12.5 KVA to 82.5 KVA disconnecting all fuel inlet and outlet lines, disconnecting the drive for carrying out repairs/ replacements including calibration, re assembling of FIP and fixing back in position after repair/ replacement of unserviceable parts all as directed. Note :- 1. Calibration of FIP complete shall be got done from manufacturer authorized dealer/ workshop to entire satisfaction of Engineer- in- charge.2.Shifting and loading/Unloading of FIP and transporting for repair in workshop at Ramgarh/ Ranchi city from existing location/site is including in deemed rate |
| 285 | Supply and fixing in repairs thefollowing unserviceable parts of 12.5 KVA to 82.5 KVA capacity of DG set are as under :- |
| 286 | (a) Nozzle plunger. |
| 287 | (b) Delivery valves. |
| 288 | (c) Injector holder with washers. |
| 289 | (d) Injector. |
| 290 | (e) FIP packing Kit. |
| 291 | (f) Bearing number 30203 or suitable existing matching number |
| 292 | (g) Bearing number 6203 or suitable existing matching number |
| 293 | Supply and fixing in repairs/replacement of engine control panel UNSV parts as under :- |
| 294 | (a) Oil Pressure Gauge as per approved Make |
| 295 | (b) Oil Temperature Gauge as per approved Make |
| 296 | (c) Hours meter as per approved Make |
| 297 | (d) Ampere meter as per approved Make |
| 298 | (e) Volt meter as per approved Make |
| 299 | Taking down & repairs of old turbo charger assembly from engine mounting by opening nut, bolt and transporting to civil workshop for repairing,cleaning and servicing from inside and outside with anti rust solution, checking the same and repairing for any leakage by brazing the turbo charger and ensure for no leakage. Refixing the turbo charger at same place of 30 KVA to 63 KVA capacity DG set.Note:- Transportation cost included in unit quoted rate. |
| 300 | Taking down & repairs of old turbo charger assembly from engine mounting by opening nut, bolt and transporting to civil workshop for repairing,cleaning and servicing from inside and outside with anti rust solution, checking the same and repairing for any leakage by brazing the turbo charger and ensure for no leakage. Refixing the turbo charger at same place of 82.5 KVA to 125 KVA capacity DG set.Note:- Transportation cost included in unit quoted rate. |
| 301 | All as above item No 306,but 250 KVA capacity DG set.Taking down & repairs of old turbo charger assembly from engine mounting by opening nut, bolt and transporting to civil workshop for repairing,cleaning and servicing from inside and outside with anti rust solution, checking the same and repairing for any leakage by brazing the turbo charger and ensure for no leakage. Refixing the turbo charger at same place of 250 KVA capacity DG set.Note:- Transportation cost included in unit quoted rate. |
| 302 | M& L in replacements ofPVC coolant makeup bottle of cap 3.5 Ltr suitable for 30 KVA DG set as existing complete all as specified. |
| 303 | M& L in replacementsof PVC coolant makeup bottle of cap 6.5 Ltr suitable for 82.5 KVA to 125 KVA DG set as existing complete all as specified. |
| 304 | S&F in replacement of DG Set battery 12 volt, 180 AH as existing for 200 KVA DG set capacity including dismantling of old battery. |
| 305 | Supply only of of battery 150 AH, 25 plate with initial Charger Specific gravity 12.60 of 12 volts complete all as directed by Engineer-in-Charge. |
| 306 | S&F in replacement of ON Load Change over switch capacity upto 63 Amps capacity 415 Volts, 4-Pole incl sheet metal enclosure as per the existing switch including taking out old unserviceable one and connection complete all as specified and as directed.Make : L&T / Indo Asian / Hevells . |
| 307 | S&F in replacement of ON Load Change over switch of 100 Amps capacity 415 Volts, 4- Pole incl sheet metal enclosure as per the existing switch including taking out old unserviceable oneand connection complete all as specified and as directed.Make : L&T / Indo Asian / Hevells . |
| 308 | S&F in replacement of ON Load Change over switch of 160 Amps capacity 415 Volts, 4 pole, incl sheet metal enclosure as per the existing switch including taking out old unserviceable one and connection complete all as specified and as directed. Make :L&T / Indo Asian / Hevells . |
| 309 | S&F in replacement of ON Load Change over switch of 200 Amps capacity 415 Volts, 4 pole, incl sheet metal enclosure as per the existing switch including taking out old unserviceable one and connection complete all as specified and as directed. Make :L&T / Indo Asian / Hevells . |
| 310 | Supplying and laying un-reinforced pre -cast concrete cable cover class LV, Type - 1 , flate, size 250 mm x 150 mm x 40 mmcomplete all as specified and as directed by the Engineer-in-Charge. |
| 311 | S & F in repair MCCB, 4 pole, 415 V, thermal magnetic release setting with 100% ICU, 160 amps with breaking capacity 36 KA, duly ISI marked, complete all as specified and as directed. |
| 312 | S & F in repair MCCB, 4 pole, 415 V, thermal magnetic release setting with 100% ICU, 200 amps with breaking capacity 36 KA, duly ISI marked, complete all as specified and as directed. |
| 313 | S & F in repair MCCB, 4 pole, 415 V, thermal magnetic release setting with 100% ICU, 400 amps with breaking capacity 36 KA, duly ISI marked, complete all as specified and as directed. |
| 314 | S & F in repairAluminium thimbles of size 50 Sq mm to 120 Sqmm of 3.5 coreand including removing burnt thimbles from existing XLPE cables & cable made to suitable for fixing new thimbles complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail