| 1 | Excavation in post holes (or similar holes) each not exc 0.5 Cum and getting out, returning filling in and ramming earth or borken rubble mixed with earth around in layers not exc 25cm watering and removing surplus spoil to a distance not exc 50m and making good surface in soft/loose soil all as specified and directed. |
| 2 | M&L for providing plain cement concrete1:2:4, type B2, using 40mm aggregate, any size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts bases etc complete all as specified and as directed. |
| 3 | S&F mild steel works as in fencing, posts & strutsin fencing embedded in stone masonry/bricks works or concreteincluding cutting tops to shape as directed, drilled holes notching for wires flat iron fillets (for securing wire mesh etc) inlcuding all drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and asdirected |
| 4 | S&F mild steel round bars 10mm dia and over, in horizontal support for chain link fencing straining of fencing including cut to length, bent to shape required including cranking, bending spirally for hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-W (Gde E-250) complete all as specified and directed. |
| 5 | Supply only mild steel galvanised security chain link fencing 100mmx100mm or 75mmx75mm with 4mm nominal dia wire, both ends without knuckling /twisting, fixed to flat iron rails with RCC/Angle iron post complete all as specfied and directed.Note:-Weight of chain link fencing shall be ascertain through BOO. |
| 6 | Fixing only chain link fencing, any mesh, size and type to any type of standards, rails, straining bolts, etc. including providing of binding wire or clips complete all as specified and directed. |
| 7 | S&F in Galvanized, 2 strand, steel barbed wire 2.24 mm dia., barbed with 2 mm dia., barbs at 75 mm spacing and strainedand fixing to any type of standard rails straining bolts, etc. all as directed. (Each line wire to be measured) |
| 8 | Preparation of new or previously untreated steel surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint of approved shade over a coat of red oxide primer complete all as specified. |
| 9 | Excavation in trenches n.exc 1.5m deep & n.exc 1.5m wide and n. exc 10 sqm on plan, getting out in soft/loose soil complete all as specified and as directed. |
| 10 | Returning, filling including spreading leveling watering and well ramming in layers not exc 25 cm thickness using excavated soft/loose soil complete all as specified and directed. |
| 11 | Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point for soil complete all as specified and directed. |
| 12 | M&L PCC 1:4:8 type D-2 (using 40 mm graded stone agg) as in foundation ,filling mass complete all as specified & directed. |
| 13 | M&L for RCC 1:2:4, type B1 using 20mm graded aggregate as in Foundations, beam, plinth beams, base of columns etcbasement slabs complete all as specified. |
| 14 | M&L for RCC 1:2:4, type B1 using 20mm graded aggregate as in columns, pillars, piers, post and struts etc complete all as specified. |
| 15 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or batter complete all as specified & directed. |
| 16 | M& L Formwork to sides of colums, pillars, posts etc. rough finished surface of suqare or rectengular complete all as specified and as directed. |
| 17 | Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 18 | Mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 19 | S&F mild steel works as in doors or gates of angle or other sectons with gusset plates, rails, braces etc complete drilled, welded etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging also fastening and fixing all complete conforming to Fe 410 -W (Gde- E- 250) quality- A. |
| 20 | S&F MS Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified. |
| 21 | M&L MS Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes comforming to Fe-290 (Gde E-165) grade , without any attachment all as specified and directed. |
| 22 | S&F for Rotational moulded polyethylene water storage tanks 1000 ltr cap.(cylindrical vertical with closed top) hoisted and fixed in position including 20 mm PTMT ball cock complete all as specified |
| 23 | S&F 15mm bore galvanized iron tubes medium grade with all fitting and fixed to walls, ceiling or laid in floor complete all as specified. |
| 24 | S&F bib taps cast copper alloys with crutch or butterfly handle chromium plated fency type, screwed down screwed for iron pipe of 15 mm bore complete all as specified. |
| 25 | S&F 15mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 26 | M&L for Point wiring with 1.5 Sq mm copper conductor single core FR PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC caping and casing surfacetype andaccessories of suitable size ISI marked and pressed steel terminal boxes of 2 mm thick MS of suitable size duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement incl provision of 3 mm thick laminated hylem sheet for mounting the switches/sockets/regulators/ceiling rose etc including running up of 1.5 Sq mm copper conductor flame retardant PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified for one light/ceiling fan/exhaust fan point controlled by one, one way switch, 5 Amps with cable 1.5 sqmm size. |
| 27 | All as per Item No 26 above but for one 3 pin socket outlet, 5 Amps, same board, with cables 1.5 sq. mm size. |
| 28 | All as per Item No 26 above but for one 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size. |
| 29 | All as per Item No 26 above but for one butusing 2.5 sq mm single core copper conductor cable of multistranded FR PVC insulated unsheathed 1100 volts grade for 5/15 Amps switch socket, Independent board including one run of1.5 sq mm copper conductor FR PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 30 | S&F switch piano, flush type,single pole one way 5 Amp complete all as specified and directed. |
| 31 | S&F Ceiling Rose, PVC/polycarbonate, isolated body 3 terminal complete all as specified and directed. |
| 32 | S&F Socket outlet 2 in 1, 3 pin, 5 Amps flush type universal complete all as specified and directed. |
| 33 | S&F Switch Socket combination 2 in 1, 3 pin, 5 Amps flush type universal complete all as specified and directed. |
| 34 | S&F Switch Socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal complete all as specified and directed. |
| 35 | S&F stepped type electronic Fan Regulator flush type complete all as specified and directed. |
| 36 | S&F Lamp holder, PVC polycarbonate type with back plate suitable for batten/angular fittings complete all as specified and directed. |
| 37 | S&F LED Bulb 7 Watt complete all as specified and directed. |
| 38 | S&F LED Bulb 10 Watt complete all as specified and directed. |
| 39 | S&F LED Bulb 15 Watt complete all as specified and directed. |
| 40 | S&F LED Tube Light Fitting 1 x 20 Watt, 220 Volts, AC decorative box type with driver, holder incl LED tube light connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 41 | S&F LED building security light fitting of capacity 35 Watt, 230 V AC outdoor type with for fixing to bldg complete all as specified and directed. |
| 42 | M&L BLDC Ceiling Fan of 1400mm sweep complete with blades, down rods, electronic regulator and accessories, 230 Volt.Min air delivery 245 CFM and service value 6.0 BEE.5 Star rated with brushless direct current motor complete all as specified and directed. |
| 43 | S&F 380mm sweep Exhaust Fan, steel body AC single Phase. 230V with blades, frame and louvers complete all as specified and directed. |
| 44 | S&F Sheet metal enclosures forDB, Single pole & Neutral, 8 way with 200 Amps rated bus bar, Double Door, 240 volts complete all as specified and directed. |
| 45 | S&F MCB SPN, 240 volts, 32 Amps, 10 kA, \"C\" curve, 50 Hz complete all as specified and directed. |
| 46 | S&F MCB SP, 240 volts, 6-32 Amps, 10 kA, \"C\" curve, 50 Hz complete all as specified and directed. |
| 47 | M & L for Earthing complete with galvanised steel earth plate electrode 600X600X6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr deep below normal ground level, connected to DB/pole/LA etc and incl GI earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers, protected with and incl 15 mm dia light grade GI pipe, 20 mm dia GI pipe (Medium grade) for watering, necessary earth work.PCC 1:3:6 type C1 concrete pit, RCC (1:1.5:3) type A1 pre-cast cover (54X54X5 cm) duly reinforced with and incl 8 mm dia TMT bar @ 150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar, embedded in pre-cast cover slab all as specified and shown in electrical plate No-3 of SSR Part-I incl testing on completion complete all as specified and directed. |
| 48 | M&L for sand cushioning using dry and clean river sand in two layers, first layers of 80 mm thick before laying of cable and second layer of 150 mm thick after laying of cable in trenches/ducts including consolidation of each layers upto 180mm thick complete all as specified and directed.Note :- Punned thickness only will be measured and paid. |
| 49 | Supply and laying well burnt clay Bricks, locally available best quality (sub class \"B\" bricks) laid in trenches perpandicular to U/G cable for cable protection complete all as specified and directed. |
| 50 | Supply and lay XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade of size 95 Sqmm x 3.5 Core complete all as specified and directed. |
| 51 | Supply and laying of 50mm dia GI tubinglight grade in protection of cable at road crossing /hard standing/pole etc. fixed with clamps as per site requirement etc all as specified anddirected |
| 52 | Supply and installation CPRI approved LT Electric control panel, cubical type, for outdoor use, double door dust & vermin proof floor mounted made out of CRCAsteel sheet of3.15 mm thick (outer part) and 2.00 mm thick other parts andangle iron legs of size 50mmx50mmx6mm having front and rear hinged doors with front openable shutters for each MCCB/Change Over with spreader & extended rotary handle having hinges on one side and locating arrangements with screws type on other sides completely with fully enclosed bus bar chamber, having electrolytic high conductivity insulated bas bar made but of aluminium strips of rating 400 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over as coat of red oxide primer complete all as including necessary PCC platform of height 45 cm from the ground level complete all as specified and directed as following components:-INCOMMING : (i) MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 25 kA - 01 No(ii) Basic Multifunction Meter Cl 0.5 with RS485 - 01 No.(iii) LED Indicator lamp in three colour RYB - 01 Set of 3.OUTGOING :(i) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 kA - 03 No\"s(ii) MCCB 4 Pole, 415 V, Adjustable type, 40 Amps with breaking capacity 16 kA - 02 No\"s |
| 53 | M & L for Earthing complete with galvanised mild steel earth plate electrode 600X600X6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr deep below normal ground level, connected to machinery/equipment etc and incl GI strip 32×6 mm dia as earthing lead by means of bolts, nuts, check nuts and washers, protected with and incl 50 mm dia light grade GI pipe, 20 mm dia GI pipe (Medium grade) for watering, necessary earth work.PCC 1:3:6 type C1 concrete pit, RCC (1:1.5:3) type A1 pre-cast cover (54X54X5 cm) duly reinforced with and incl 8 mm dia TMT bar @ 150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar, embedded in pre-cast cover slab all as specified and shown in electrical plate No-3 of SSR Part-I incl testing on completion complete all as specified and directed. |
| 54 | Supply and fix steel tubular swaged pole 8.50 m long complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP -22 complete all as specified and directed. |
| 55 | Supply and fixing LED street light fitting 35 watt 230 volt, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 56 | S & F Street light bracket arm of length not less than 1.2 m made out of GI tubing, 32 mm bore, light grade fixed to pole, etc with 2 sets of suitable size flat iron clamp 40x5mm of suitable length, nuts, bolts & washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 57 | S&F pole mounted shockproof and rustproof Junction Box rectangular shape, 4 way of size 240X130X110 mm indoor/outdoor type and fixing with one MCB SP 10 Amps, \"C\" curve, 10 kA including fixing with two nos flat iron clamps of suitable size with necessary mild steel nuts & bolts complete all as specified and as directed. |
| 58 | Supply and fixing PVC insulated three core aluminium cable 4 sq mm for connection of security light from junction box to street light complete all as specified and directed. |
| 59 | S&F GI tubes, \"light grade\", galvanised, with all fitting; laid in trenches of size 32mm bore dia complete all as specified and directed. |
| 60 | Material and labour for plain cement concrete 1:3:6 type C-2 with 40 mm graded aggregate for column/pillar/ pole etc complete all as specified and directed. |
| 61 | Material and labour for plain cement concrete 1:2:4 type B1 using 20mm graded aggt in roof/kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. |
| 62 | Supply and fixing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross sectional area 10 sq mm 2 core complete all as specified and directed. |
| 63 | Supply & Fixing/ Laying Galvanised steel water tubing (Medium Grade), ISI Marked with all new GI Fittings laid in wall etc of size 25 mm dia complete all as specified and as directed. |
| 64 | Supply & Fixing/ Laying Galvanised steel water tubing (Medium Grade), ISI Marked with all new GI Fittings laid in wall etc of size 40 mm dia complete all as specified and as directed. |
| 65 | Supply & Fixing/ Laying Galvanised steel water tubing (Medium Grade), ISI Marked with all new GI Fittings laid in wall etc of size 50 mm dia complete all as specified and as directed. |
| 66 | Supply and Fix Gunmetal Gate valve with iron wheel head, screwed both ends, ISI marked fixed to GI pipe of size25 mm dia complete all as specified and as directed. |
| 67 | Supply and Fix Gunmetal Gate valve with iron wheel head, screwed both ends, ISI marked fixed to GI pipe of size20 mm dia complete all as specified and as directed. |
| 68 | Cutting existing PPR/steel tubing for alterations or additions if necessarily done in position without taking down of size upto 50 mm dia bore complete all as specified and directed. |
| 69 | Supply, Installation & testingOrganic Waste Management Machine as speceifiied and as directed with the followings : - (a) Oragnic waste composting machine of capacity 500 Kg/day.Input: Food waste, garden waste & all other organic waste.Output:- Oragnic bio-fertiliser (BalanceBiofertiliser rich in micronutrients)(b) Biofics Canveyor Belt (500 Kg/Hr)Input :-All type of Organic Waste.Output :-Feeding into the digestor and etc.(c) Biofics Organic Waste Shredder (500 Kg/Hr)Input :-All type of Organic Waste.Output :-Cut it into small pieces for easy composting.(d) Biofics Plastic Waste Shredder (100 Kg/Hr)Input :-All type of Plastic Waste.Output :-Convert into small pieces.(e) Biofics Incinerator (50 Kg/Hr)Input :-Other Waste.Output :-Convert into ashes. |