| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. :All kinds of soil. |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 3 | P/L cement concrete - all works upto plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 40 mm nominal size) |
| 4 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified mininum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.5.33.1 All works upto plinth level. Concrete of M25 grade with minimum ce |
| 5 | All works above plinth level upto floor V level. Concrete of M25 grade with minimum cement content of 330 kg /cum. columns, pillars piers etc. |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars |
| 10 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) |
| 11 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 12 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 13 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 14 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 15 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 16 | cladding of sal wood for signage |
| 17 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : |
| 18 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 19 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. |
| 20 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m² |
| 21 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 22 | 1:4:8 (1 cement: 4 coarse sand : 8 graded stone aggregate 40 mm. nominal size ) |
| 23 | Providing and laying 20 mm thick rubber tiles 500mmx500mm size as per specifications |
| 24 | Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming, consolidating and dressing complete. |
| 25 | Diluting and injecting chemical emulsion (Chlorpyriphos/Lindane E.C. 20% with 1% concentration), at the rate of one litre per hole at 300 mm c/c to all the horizontal and vertical surfaces of the excavations made for the foundation of the building, soil under floors, apron, back fill material and along all the faces of the walls for PRE-CONSTRUCTIONAL anti-termite treatment (including the cost of chemical emulsion) as per IS:6313 Part-II. (Plinth area of Building shall be measured for Payment) |
| 26 | Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 27 | Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 28 | Suspended floors, roofs, landings, balconies and access platform |
| 29 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 30 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 31 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 32 | Providing and fixing ISI marked Bright finished M.S. fitting for door windows 250x16x5 mm sliding door bolts |
| 33 | Providing and fixing ISI marked Bright finished M.S. fitting for door windows 250x10 mm Tower bolt |
| 34 | Providing and fixing ISI marked Bright finished M.S. fitting for door windows 150x10 mm Tower bolt |
| 35 | Providing and fixing ISI marked Bright finished M.S. fitting for door windows 125 mm handles |
| 36 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 37 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Sal wood |
| 38 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment). |
| 39 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.M.S. tube |
| 40 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete. |
| 41 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make,in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 42 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as pecified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 43 | 6 mm cement plaster 1:3 (1 cement: 3 fine sand) |
| 44 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water tinnable priming coat with cement primer |
| 45 | (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. |
| 46 | Grading roof for water proofing treatment with Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 47 | WGSTLMOD point wiring in pvc conduit , with modular type switch : wiring for light / fan point / call bell point with 1.5 sq.mm FR PVC insulated copper conductor core cable im surface recessed pvc conduit with modular switch , modular plate , suitable GF box abd earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required. |
| 48 | LPACCMOD S/F Light plug point modular type accesorries : each supplying and fixing suitable size GI box with modular plae and cover in front on surface and recess , including providing and fixing 3 pin 5/6 amps modular sockets outlet and 5/6 amps modular socket outlet and 5/6 amps modular switch, connecton ,painting etc. as required .(for light plugs to be used in non residentials buildings) |
| 49 | PPACCMOD S/F power plug point modular type accessories : each supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular sockets outlet and 15/16 amps modular switch, connecton, painting etc. as required |
| 50 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire |
| 51 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 52 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.3 Module (100mmX75mm) |
| 53 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (200mmX150mm) |
| 54 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door |
| 55 | S/F \"B\" series, SP MCB Supplying and fixing 5 amps to 32 amps rating, 240 volts, \"B\" series, miniature circuit breaker suitable for lighting and other loads of folloeing poles int the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 56 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A |
| 57 | G.I earth plate elctrode: Earthing with G.I earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. including charcoal or coke for G.I. or copper plate earth electrode as required.and salt as required. |
| 58 | S/L SWG GI wire in ground: Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required |
| 59 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 60 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet |
| 61 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 62 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering 7.3.1 Upto 35 sq. |
| 63 | Supplying and fixing of Decorative LED tube light fitting 18W, 4 feet complete with making connection and complete with all respect directed/approved by E/I.Havells make |
| 64 | S/F of Decorative mirror Linght / LED Batten polycarbonate housing& intregrated electronic driver & making connection complete in all respect. 9W 830 Including GST, Cartage, Labour Charges etc. |
| 65 | S/F of Exhast fan 230/300 mm as approved by E/I complete with making connection---- complete in all respect.Including GST, Cartage, Labour Charges etc. |
| 66 | S/F of PVC insulated Aluminium Armoured served XLPE power cable 10 sqmm. 4 core 650/1100 V grade confirming to IS 7098 (Part-1) 1988 complete in all respect. |
| 67 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 68 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 20 mm dia |
| 69 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work 20 mm dia nominal bore |
| 70 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 15 mm dia nominal bore |
| 71 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :20 mm nominal bore |
| 72 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 73 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.20 mm nominal bore, 120 mm long, weighing not less than 198 gms |
| 74 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.75 mm diameter |
| 75 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.110 mm diameter |
| 76 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 75 mm |
| 77 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110 mm |
| 78 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5° - 75 mm bend |
| 79 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5° - 110 mm bend |
| 80 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 81 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 82 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 83 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan with ISI marked white solid plastic seat and lid |
| 84 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 85 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 86 | Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long, weighing not less than 88 gms |
| 87 | Providing and fixing PTMT stop cock of approved quality and colour. Concealed stop cock, 15 mm nominal bore, 108 mm long, weighing not less than 108 gms |
| 88 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings,standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet gratingand other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :17.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern |
| 89 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc.Complete as per standard design ine Inside dimensions 455x610 mm and 45 cm deep for single pipe line |
| 90 | Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets |
| 91 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 92 | Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to site of laying but excluding the cost of centering,shuttering, finishing and reinforcement. including Admixture in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge M-25 grade reinforced cement concrete by using 410.0 kg of cement per cu.m of concrete. All work upto floor V level. |
| 93 | Centering and shuttering including strutting, propping etc. and removal of form for:Suspended floors, roofs, landings, balconies , lintel and beams etc. |
| 94 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth inCement mortar 1:6 (1 cement : 6 coarse sand) |
| 95 | 15 mm cement plaster on rough side of single or half brick wall of mix - 1: 6 (1 cement: 6 fine sand) |
| 96 | 455x610 mm rectangular C.I. cover (light duty)the weight of the cover to be not |
| 97 | Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 20 mm |
| 98 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 99 | Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge. |
| 100 | Providing and stacking of Alpinia Variegated (three in one) having ht. 30 cm and above, with fresh and healthy variegated foliage in 25 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. |
| 101 | Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.. |
| 102 | Providing and stacking of Ficus benjamina (green) of height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the officer-in-charge. |
| 103 | Providing and stacking of Hibiscus rosasinensis of height 90-105 cm., bushy in big size HDPE bag as per direction of the officer-in-charge. |
| 104 | Seeding and Mulching Preparation of seed bed on previously laid top soil, furnishing and placing of seeds, fertilizer, mulching material, applying bituminous emulsion @ 0.23 litre per sqm and laying and fixing jute netting, including watering for 3 months all as per Technical Specification Clause 310. |
| 105 | Trimming of grass and weeds from the shoulders/berms and disposing off the same to suitable locations as per technical specifications Clause 1914 |
| 106 | P/FIXING Pvc coated jalli for boundry wall |
| 107 | supply and fixing of m.s bench(size1.8x.45m) complete with painting as per the direction of engnieer (including GST) |
| 108 | supply and fixing dustbins including gst |
| 109 | Providing and fixing of firbe design work by the using premium quality resin,superfine french chowk powder,glass wool mat ,hardner,cobalt,10-12mm dia R/F work as per engnieer Beer 6 fit HT |
| 110 | Providing and fixing of firbe design work by the using premium quality resin,superfine french chowk powder,glass wool mat ,hardner,cobalt,10-12mm dia R/F work as per engnieer Family of DEER(HIRAN) 3 NOS of 4 fit HT |
| 111 | Providing and fixing of firbe design work by the using premium quality resin,superfine french chowk powder,glass wool mat ,hardner,cobalt,10-12mm dia R/F work as per engnieer Tiger(BAGAH) of 5 fit HT |
| 112 | Providing & fixing of water fountain linear water fountain it include all civil work as per enginner |
| 113 | Solar street light (LED BASED)Consist of white LED luminaire (LED + Driver )rating as per configration along with solar pv modules and lifepo4 battery of given capacity ,necessary control electronics , interconnecting wires/cables,module mounting structures etc to operate from dusk to dawn |
| 114 | fully self contained kitchen on wheels that can be driven/pulled to various location |
| 115 | supply & fixing of kids eqipments slides 3 layers premium quality pplatics the direction of enginner (including GST) slide |
| 116 | supplY & fixing of kids eqipments slides 3 layers premium quality pplatics the direction of enginner (including GST) seesaw |
| 117 | Aquaguard Storage Type Water Cooler 60 LPH Cooling CapacityAquaguardR(AG PRO PURE CHILL 120 PSS - RO+UV+CuZn) Please Enable Macros to View BoQ information |