| 1 | Supply and Fix of Non- illuminated retro reflective GuidanceSign Board of 800mm to 1200mm X 700mm andsizes for runway code numberwith an all-Aluminum weather-proof sturdyframe keeps protected from environmental hazardsand mechanical enclosure will have designed such away that it can be opened for maintenance from thefront without any special tools. The top edge shouldhave heavy-duty hinges that open the front doortowards the top side and IP65 or above sealed toprovide protection against dust and rain ingressincluding supporting frangible legs & frame etc. &sign shall comply as per ICAO Annex.14 Vol.I, ADMpart 4 and ADM part 6. legs fixed to 450 mm PCC (1:2:4) type B-2 size (1300 x 900) laid over 150 mm thick PCC (1:4:8) type D-2complete all as detailed in drwg No.GE(M)/ARK/2025/01, specified and directed. |
| 2 | Supply and Fix of Distance To Go Marker (1220 mm X 1800mm) consist ofno steel part for runway air strip reflective triangular shape (hollow) of each side 122 x 180cm having required circular perforation to ease with wind thrust pressure. Bottom square holes on each side for the release of accumulated rain water inside the hollow triangular structure. Marker body made from Ultraviolet resistant engineer grade FGRP material bonded with epoxy chemicals having ribs anti-termite coated wooden in-cubes at the top, centre and bottom. Horizontally 50 x 20mm size and vertical 25x20mm size. Monolithic structure to withstand high wind pressure, temperature variations from extreme cold to hottest weather conditions and not effected by the rain. Inside coated with fire retardant antimony trioxide in chemical base and shall complywith ADM part 6. Structure supported over three legs of 75 mm NB HDPE Pipe of exposed length 300 mm . Bottom part of the DTGM to have horizontal 25mm NB HDPE pipe support up to the legs. Marking on two sides of the sign with reflective sheet complete all as detailed in drwg No.GE(M)/ARK/2025/02 specified and directed.Make: Greenlite/poshdecor/Vibgyor/Trafitronics |
| 3 | Conducting Skid Resistance Test by using Pendulum Apparatus (wet and dry condition) at various points along flexible surface of Runway/ PTT including mobilization and demobilization of men and machineries. Two binded copies of test results shall be submitted complete all as specified and directed. |
| 4 | Material and labour for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed |
| 5 | Demolition of cement concrete ( unreinforced) in ground floors and paving n. exc 15 cm thick ( below & above ground level) and removal & rubish of Premises exc 250 m but n exc 500 m complete all as specified and as directed |
| 6 | Material and labour for hardcore of gauge not exc 63mm, deposited, spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed |
| 7 | Material and labour for plain cement concrete type D-2, 1:4:8 (Using 40mm graded stone aggregates) as in sub base complete all as specified and as directed |
| 8 | Material and labour for sand filling as a cushioning/ bedding complete all as specified and as directed |
| 9 | Material and labour for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 gradewith grey cement and no pigmentcomplete all as specified and as directed |
| 10 | Material and labour for chequred cement concrete tiles 300x300x20-22mm thick set, jointed and pointed in neat cement slurry over 20mm thick screed bed in CM 1:6 with coloured cement to match the shade of tiles complete all as specified and as directed |
| 11 | Material and labour for cement concrete type B-0, 1:2:4 (Using 12.5 mm graded stone aggregates) for edging/coping complete all as specified and as directed |
| 12 | Material and labour for 75mm thick PCC 1:3:6 type C-1 (Using 20mm graded stone aggregate) as in flooring, including finished even and smooth without using extra cement complete all as specified and as directed |
| 13 | Material and labour for preparation of plastered or unplastered old decorated surfaces of walls including cornices, chajjas and shades etc including complete removal of existing treatmentand applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqmin chequered / zebranic pattern, white/ terracota at any height of building/ tower complete all as specified and as directed |
| 14 | M&L Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with cement mortar 1:4 complete all as specified and as directed |
| 15 | M&L for Joint free Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed |
| 16 | Removal of old Wind Direction Indicator (WDI) pole and supply & fix in repairs of frangible WDI in compliance withAnnexure 14, Vol. I par. 5.1.1 & full compliance with FAA, AC No. 150/5345-45. Frangible fiber glass Mast of red/ white of size400x 400x 4500mm approx. Resistance to wind to minimum 140km/hrs. easy lowering arrangement for maintenance without re-alignment required, Windsock in ICAORed/White or black white as directed of length 3.6 mtr x dia 0.9m of nylon fabric, water repellent& resistant to rotting and mildew, External and Internal LED lighting, mast assemblyfitted with LED obstruction light complete with base as per OEM directions, complete all as specified and as directed.Notefor Serial item No. 1 to 16: Kind attention of tenders is invited to that runway will be available to execute the work on Saturday and Sunday or on holiday or as required by the user. The tenderer has to work as per user\"s requirement and unit rate quoted by the tenderer shall be deemed to include for this provision/condition. |