| 1 | Supply and installation of Galvanised steel HIGH MAST LIGHTING SYSTEM OF 16 Meter with comprising of following :- (i) Supply of 16M highmast shaft in two sections suitable for wind speed, with head frame, winch mounting bracket, luminaries carriage suitable to install 08 Nos luminaries insymmetrical arrangement.(Bajaj)(ii) Supply of raising lowering system comprising double drumwinch, 6mm diameter SS wirerope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightening finial, counter weight. (Wiring material from JB to individual luminaire & MCB in base compartment are not included and are a part of installation).(iii) Supply offoundation bolts manufactured from special steel alongwith nuts, washers, anchor plate and common template.(iv) Supply of LED type single dome aviation obstruction light.(v) Supply of outdoor stand mounted feeder pillar with 63 A TPN MCB Bincomer, single dial time switch, 63A TP contactor for the automatic switching of luminaries, power tool control with 2 Nos 16A contactor sand raise lower push button, Incoming 35 sq.mm and outgoing 16 & 2.5 sq. mm terminals. |
| 2 | (vi) Erection Part :- (a) Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as10T/sqmtr at 2 metre depth with all materials and labour.(b) Erection of the highmast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5sq.mm, lugs, MCB and all labour.(HYDRA SHALL BE ARRANGED BY CONTRACTOR) (c) Installation of the mast feeder pillar by grouting the stand in concrete. |
| 3 | Supply and fix LED flood light 300 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lampcomplete all as specified and as directed. Make :- Havells Catpart No. JETAMONOSNEOFL300WHELED757WBTOTG or equivalent to Wipro/ Bajaj |
| 4 | Supply and fixing in replacement of Octagonal Hot- Dip galvanized street light pole including junction box with double arm bracket of following sopecification - Height 7Mtrs, top dia 70mm, bottom dia 130 mm, sheet thickness 3mm base plte 220x220x12mm with foundation bolt (M20X750) 04 Nos including taking out old PCC/Steel Tubular Pole complete all as specified and directed. Make:- Bajaj / Crompton / Phillips / Surya. |
| 5 | Supply and fixinginreplacement of LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr In charge |
| 6 | Supply & Fixing in replacement of installation, testing and commissioning factory made, floor mounted Indoor type LT panel board, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, CPRI approved manufactures having bus bar chamber with insulatedbus bar Copper 1200Amp rated, four wire system, colour coded for each phase of rating as per under for phase and neutral, insulated on epoxy type insulators. The panel shall be dust and vermin proof, IP-54 class protection and made 2.0 mm of outer body and inner body 2.00 mm thickCRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm)including grouting of panel 30 cm above ground level by providing 60 cm long angle iron frame of size 40x40x5mm, welded on all the four corners, embedded in pcc 1:2:4 using 20 mm stone aggregate upto 30 cm complete all as specified and directed including the following accessories:- (Make :- CPRI Approved)For Naval Base Power House Main Panel |
| 7 | (a) ACB 630 Amps,4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) - 01 No (Incoming)(b) MCCB Thermal magnetic based 250Amps 4 pole, 25 KA, 415 Volt (Ougoing)- 02 Nos(c ) MCCB Thermal magnetic based 200 Amps 4 pole, 25 KA, 415 Volt (Outgoing) - 01 No(d) MCCB Thermal magnetic based 100 Amps 4 pole, 25 KA, 415 Volt (Outgoing) - 02Nos(e) MCB TPN 63 Amps \"C\" Curve breaking capacity 10KA (O/G) - 01 Nos(f) MCB SPN 32 Amps \"C\" Curve breaking capacity 10KA(O/G) - 02 Nos(g) ON Load Change Over Switch 400 Amp, 415Volt, 4Pole, 35 KA - 02Nos(h) Digital Ammeter with CT\"s and Selector switch-01 No(j) Digital Voltmeter with selector switches - 01 No(k) Digital Multifuntional Meter with selector switches -03 Nos(l) Indicating lamp LED Type-RYB-03 Set |
| 8 | Supply & Fixing in replacement of installation, testing and commissioning factory made, floor mounted outdoor type LT panel board suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, CPRI approved manufactures having bus bar chamber with insulated Aluminium bus bar 400Amp rated, four wire system, colour coded for each phase of rating as per under for phase and neutral, insulated on epoxy type insulators. The panel shall be dust and vermin proof, IP-54 class protection and made 3.15 mm of outer body and inner body 2.00 mm thickCRCA MS sheet , powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm)including grouting of panel 30 cm above ground level by providing 60 cm long angle iron frame of size 40x40x5mm, welded on all the four corners, embedded in pcc 1:2:4 using 20 mm stone aggregate upto 30 cm complete all as specified and directed including the following accessories:- (Make :- CPRI Approved)(For :- N/Nagar Near - P-5 Bldg & KV Qtr Main Panel)(a) MCCB Thermal magnetic based200Amps 4 pole , 35 KA, 415 Volt(Incomer) - 01 No(b) MCCB Thermal magnetic based 63Amps 4 pole ,25 KA, 415 Volt (Ougoing)- 04 Nos(c) MCB TPN 40 Amps \"C\" Curvebreaking capacity 10KA - 02Nos(d) Digital Ammeter with CT\"s and Selector switch-01 Set(e) Digital Voltmeter with selector switches - 01Nos(f) Digital Multifuntional Meter with selector switches - 01No(g) Indicating lamp LED Type-RYB-01 Set |
| 9 | Supply & Fixing in replacement of installation, testing and commissioning factory made, floor mounted outdoor type LT panel board suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, CPRI approved manufactures having bus bar chamber with insulated Aluminium bus bar 400Amp rated, four wire system, colour coded for each phase of rating as per under for phase and neutral, insulated on epoxy type insulators. The panel shall be dust and vermin proof, IP-54 class protection and made 3.15 mm of outer body and inner body 2.00 mm thickCRCA MS sheet , powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm)including grouting of panel 30 cm above ground level by providing 60 cm long angle iron frame of size 40x40x5mm, welded on all the four corners, embedded in pcc 1:2:4 using 20 mm stone aggregate upto 30 cm complete all as specified and directed including the following accessories:- (Make :- CPRI Approved)(For :- Naval Base DSC Line Main Panel)(a) MCCB Thermal magnetic based200Amps 4 pole , 35 KA, 415 Volt(Incomer) - 01 No(b) MCCB Thermal magnetic based 100mps 4 pole ,25 KA, 415 Volt (Ougoing)- 02Nos(c) MCCB Thermal magnetic based 63Amps 4 pole ,25 KA, 415 Volt (Outgoing) - 02Nos(d) MCB SPN 32 Amps \"C\" Curvebreaking capacity 10KA (O/G) - 02Nos(e)Digital Ammeter with CT\"s and Selector switch-01 Set(f)Digital Voltmeter with selector switches - 01 No(g)Digital Multifuntional Meter with selector switches - 01 No(h) Indicating lamp LED Type-RYB-01 Set |
| 10 | Supply & Fixing in replacement of installation, testing and commissioning factory made, floor mounted outdoor type LT panel board suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, CPRI approved manufactures having bus bar chamber with insulated Aluminium bus bar 400Amp rated four wire system, colour coded for each phase of rating as per under for phase and neutral, insulated on epoxy type insulators. The panel shall be dust and vermin proof, IP-54 class protection and made 3.15 mm of outer body and inner body 2.00 mm thickCRCA MS sheet , powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm)including grouting of panel 30 cm above ground level by providing 60 cm long angle iron frame of size 40x40x5mm, welded on all the four corners, embedded in pcc 1:2:4 using 20 mm stone aggregate upto 30 cm complete all as specified and directed including the following accessories:- (Make :- CPRI Approved)(For :- N/Nagar Near P-16 Block & NCB Main Panel)(a) MCCB Thermal magnetic based 250Amp, FP,35 KA, 415 Volt(Incomer) - 01 No(b) MCCB Thermal magnetic based160 Amps, 25 KA, FP, 415 Volt(Ougoing)- 01 No(c) MCCB Thermal magnetic based63 Amps, 25 KA, FP, 415 Volt (Ougoing) - 03 Nos(d) MCB TPN 40 Amps \"C\" Curvebreaking capacity 10KA - 02Nos(e)Digital Ammeter with CT\"s and Selector switch-01 Set(f)Digital Voltmeter with selector switches - 01 No(g)Digital Multifuntional Meter with selector switches - 01 No(h) Indicating lamp LED Type-RYB-01 Set |
| 11 | Supply & Fixing in replacement of installation, testing and commissioning factory made, floor mounted outdoor type LT panel board, cubicle type, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, CPRI approved manufactures having bus bar chamber with insulated Aluminium bus bar 200Amp rated four wire system, colour coded for each phase of rating as per under for phase and neutral, insulated on epoxy type insulators. The panel shall be dust and vermin proof, IP-54 class protection and made 3.15 mm of outer body and inner body 2.00 mm thickCRCA MS sheet , powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm)including grouting of panel 30 cm above ground level by providing 60 cm long angle iron frame of size 40x40x5mm, welded on all the four corners, embedded in pcc 1:2:4 using 20 mm stone aggregate upto 30 cm complete all as specified and directed including the following accessories:-(Make :- CPRI Approved)(For :- Strret Light Panel Naval Base,NCB & NCN Bldg)(a) MCCB Thermal magnetic based100 Amp, FP, 415 Volt, 25 KA - 01 No (Incoming)(b) MCCB Thermal magnetic based 63 Amps, 25 KA, FP, 415 Volt- 02 No (O/G) (c ) MCB 63 Amps, 10 KA, TPN, - 02 Nos (O/G) (d) Power Contactor 3 Pole 63 Amps Make : HAVELLS - 01 No (e)Multifunctional Timer switch digital type for street light ON/OFF Make :HAVELLS - 01No (f)Digital Ammeter -01 No (g)Digital Voltmeter-01 No(h)CT Rating 100/5 (f) Indicating lamp LED Type-RYB-01 Set |
| 12 | Supply and Fixing of Servo Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 160KVA including PCC Foundation complete all as specified and directed by Engr-in- Charge with following specification. (a) Type of winding - Copper wound (99.9%) - Auto Transformer. (b) Efficeincy - More than 95% (c) Control - Auto / Manual switch (to operate in case of failure) (d) MCCB - Overload / short circuit protection, phase sequence change protection, phase failure (e) Class of insulation - A Make : M/s India Techno Indus (Spectron) / M/s Vinitec Electronic Laboratory (Vinitec) / M/s Vintek Electronics (Volina), M/s Microtech / M/s Automatic Electric (AE) |
| 13 | Supply, laying & testing in replacement of cable XLPE insulated, screened, PVC bedded, galvanizedsteel strip or wire armoured, electric power cables(heavy duty)with stranded aluminium conductor,1100 volts grade, of size 3.5core 400 sq mm. complete all as specified and directed. |
| 14 | Supply, laying & testing in replacement of cable XLPE insulated, screened, PVC bedded, galvanizedsteel strip or wire armoured, electric power cables(heavy duty)with stranded aluminium conductor,1100 volts grade, of size 3.5core240 sq mm. complete all as specified and directed. |
| 15 | Supply, laying & testing of cable XLPE insulated, screened, PVC bedded, galvanizedsteel strip or wire armoured, electric power cables(heavy duty)with stranded aluminium conductor,1100 volts grade, of size 3.5core240 sq mm. complete all as specified and directed. |
| 16 | Supply, laying & testing in replacement of cable XLPE insulated, screened, PVC bedded, galvanizedsteel strip or wire armoured, electric power cables(heavy duty)with stranded aluminium conductor,1100 volts grade, of size 3.5core185 sq mm.complete all as specified and directed. |
| 17 | Supply, laying & testing in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed. |
| 18 | Supply, laying & testing of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed. |
| 19 | Supply, laying & testing in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed. |
| 20 | Supply, laying & testing in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed. |
| 21 | Supply, laying & testing in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 4 core complete all as specified and directed. |
| 22 | Supply, laying and testing in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5core complete all as specified and directed. |
| 23 | Supply, laying and testing in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed. |
| 24 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed. |
| 25 | Supply, laying and testing in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed. |
| 26 | Supply, laying & testing in replacement PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 sq mm, 3core, 1100 Volts grade complete all as specified and directed. Make:- Polycab/Havells/Gloster/KEI |
| 27 | Earth work in excavation by mechanical means (Hydraulic excavator) / in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m including taking out/laying of UG cable LT of any size complete all as specified and as directed by Engineer-in-charge . |
| 28 | Returning and filling in trenchesincl spreading, levelling watering andraming in layer n.exc 25 cm complete all as specified and directed. |
| 29 | Removing of excavated mtrls n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point. |
| 30 | Supply and lay Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size 50 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor complete all as specified and directed. Make:- ASTRAL TELEREX / Supreme / Finolex / Prince. |
| 31 | Supply and lay Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size 65 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor complete all as specified and directed. Make:- ASTRAL TELEREX / Supreme / Finolex / Prince. |
| 32 | Supply and lay Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size 90 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor complete all as specified and directed. Make:- ASTRAL TELEREX / Supreme / Finolex / Prince. |
| 33 | Supply and laying/jointing in replacement of GI Pipe mideum grade 80mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and all as specified and directed. Make -TATA / JINDAL /SWASTIK |
| 34 | Material and Labour for hard rock Horizontal Boring/Cutting of Road/Foot Path minimum 1.5 feet from ground level for 80mm bore pipe for cable protection and finishing PCC after Boring/Cutting of road/Foot path, complete all as specified and as directed. |
| 35 | M&L of in replacement earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to galvanised iron wire 4.00mm as earthing lead by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both waysall as shown in electrical plate No.3 of SSR Part-I all as specified and directed. |
| 36 | M&L of earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to galvanised iron wire 4.00mm as earthing lead by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both waysall as shown in electrical plate No.3 of SSR Part-I all as specified and directed. |
| 37 | M&L of in replacement earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to galvanised iron strip 25×4mm as earthing lead by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both waysall as shown in electrical plate No.3 of SSR Part-I all as specified and directed. |
| 38 | M&L of earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to galvanised iron strip 25×4mm as earthing lead by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both waysall as shown in electrical plate No.3 of SSR Part-I all as specified and directed. |
| 39 | M&L of earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to galvanised earth strip 32x6mm size by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both waysall as shown in electrical plate No. 3 of SSRPart-I all as specified and directed. |
| 40 | Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed by Engr-In-Charge. |
| 41 | Supply and install hi wall split AC units indoor/outdoor 1.50 TR capacity complete with cordless remote control unit and with in built air ioniser and Plasma filter for bett er indoor air quality with minimum 5 star rating and EER 3.2 complete all as specified and directed by Engineer - in - Charge. |
| 42 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA complete all as specified and directed by Engineer - in - Charge. |
| 43 | Supply and Fix of SPN Sheet metal enclosures with plug and socket with Top and MCB SP 20 Amps complete all as specified and directed by Engineer - in - Charge. |
| 44 | Supply and Fix ofMCB rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) SP of 5Amp -32Amp current carrying capacity in the MCB DB complete with connection testing and commissioning.complete all as specified and directed by Engineer - in - Charge. |
| 45 | M&L for Sub main wiring for AC pointusing PVC insulated unsheathed FRLS, stranded copper conductor cable 2 Single core of size 4 Sqmm FRLSH cable earth continuity conductor of size 4 Sqmm to be drawn through in and including surface PVC casing caping on walls/roof/floorsall as directed by Engineer in Charge.Notes:- (i)Two wires of 4 sqmm and one wire of 4 sqmm & one run of PVC conduit / casing caping shall be measured as one unit. |
| 46 | Taking down carefully aluminum/copper point wiring (light,fans,socket etc) complete incl battens and fittings such as switch, ceiling rose,light fittings, regulators, socket etc and making good disturbed surface of wall/floor etc complete all as specified. |
| 47 | M&L for point wring for one light/ fan controlled by one switch with 1.5 sqmm nominal area) PVC insulated and PVC unsheathed multi stranded copper conductor cable FRLSH in and including concealed PVC conduit 20 mm dia medium duty ISI marked, including suitable new steel sunken boxes, modular frame and cover plate for fixing of modular switches as per required point in that board, flush to surface for one light point, fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 sqmm copper conductor cable FRLSH connected to common earth duly complete including cutting, chasing the surface and then making good the same in CM 1:6 complete all as specified and directed. Notes : 1. Switches, Sockets etc shall be measured and paid for separately under appropriate items of Sch \"A\".2. PVC Casing caping wiring shall be provided where concealed wiring is not feasible (i.e. concrete surface/ beam/ column/ ceiling etc.) The same shall be deemed to included in the quoted rate. No extra cost shall be paid for the PVC casing caping item. |
| 48 | Supply and fix in Repair/Replacement offor Modular switch 1 way 6 Amps, 1 modules 230 volts of existing switch board complete all as specified and directed. |
| 49 | Supply and fix in Repair/Replacement of ceiling rose surface backelite 65x50 mm having3 terminal complete all as specified and directed. |
| 50 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) complete all as specified and directed. |
| 51 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed. |
| 52 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers complete all as specified and directed. |
| 53 | Dismantling /Removing and deposit to MES Store of the existing Ceiling /Exhaust fan any sizecomplete all as specified and directed Engr-in-charge. |