| 1 | M & L for surface sub-main wiring alongwith earth wire of size (2 x 1.5) sq. mm + (1 x 1.5) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC conduit (medium grade) of size not less than 20 mm dia with all fittings and accessories ISI marked for conduits & sinkings for modular boxes & making good to walls, floors etc. complete all as specified & as directed. Make of cable : Havells/Polycab/Finolex. Make of Conduit : Precision/Finolex/Polycab/ModiNOTE : 1) Two runs of PVC wire, one run of earth wire & one run of non-metallic PVC conduit (medium grade) will be measured as one length. 2) Modular metal flush boxes (if req) shall be measured & paid separately. 3) Cutting chases & making good the disturbed surfaces (if any) is deemed to be included in the unit quoted rates. 4) Cost of Metal clamps with fixing screws for fixing on walls/other surfaces etc. (if any) is deemed to be included in the unit quoted rates. |
| 2 | M & L for surface sub-main wiring alongwith earth wire of size (2 x 2.5) sq. mm + (1 x 2.5) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including stove enamelled steel conduit of size not less than 20 mm dia with all fittings and accessories ISI marked for conduits & sinkings for Flame Proof Modular boxes & making good to walls, floors etc. complete all as specified & as directed. Make of cable : Havells/Polycab/Finolex. Make of Steel Conduit : ISI MarkedNOTE : 1) Two runs of PVC wire, one run of earth wire & one run of stove enamelled steel conduit will be measured as one length. 2) Modular Flame Proof Metal flush boxes (if req) shall be measured & paid separately. 3) Cutting chases & making good the disturbed surfaces (if any) is deemed to be included in the unit quoted rates. 4) Cost of Metal clamps with fixing screws for fixing on walls/other surfaces etc. (if any) is deemed to be included in the unit quoted rates. |
| 3 | Taking down old sub-main wiring incl fixture & fittings etc. removing materials to store for keeping in safe custody or for taking credit & making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engr-in-Charge. |
| 4 | S & F ceiling/roof mounted energy saving, environment friendly, robust Die-Cast Aluminium Body + Toughened Glass LED High Bay IP 65 luminaire with high efficacy of rating 150 W, CRI > 80, CT>6000 K, Beam Angle - 120 degree, I/P Voltage Range 100-300 V, PF > 0.95, Luminous Efficiency > 100 Lumen/W, 10 KV Surge Voltage Protection, THD < 5%, integrated type with all accessories internally prewired and including connecting up with necessary fixing arrangements & electrical connection strictly keeping in view the Fire/Life safety aspects with & including flame proof flexible metallic conduit of required length duly enclosing external Drivers/SPDs incl connecting accessories & including 5 Years OEM Warranty on the fitting complete all as specified and as directed by Engr-In-Charge incl taking down old/unsv light fittings & depositing to MES Storeyard. Model - AVIOR, Cat No LOHY150 LN S 5Y (LENS TYPE) of make LUKER or techno-commercially equiv in Havells/Jaguar/Philips. |
| 5 | Supply and fix energy saving high power LED Bldg Security light of 50W or higher rating made up of pressure die cast aluminum housing + Toughened Glass having top opening, seperate driver compartment with IP 65 protection, CRI > 80, CT>6000 K, Beam Angle - 120 degree, I/P Voltage Range 100-300 V, PF > 0.95, Luminous Efficiency > 100 Lumen/W, 6 KV Surge Voltage Protection, THD < 5%, & fixing/fitting on existing GI pipe bracket and connecting up electrically from Junction box to light ftg by means of 3 core 1.5 sqmm copper PVC round conductor passing through 15 mm dia light grade GI Pipe & necessary Aluminium clamps, nuts, bolts, washers etc. incl taking down old unsv conventional light fittings complete all as specified and directed by Engr-in-Charge. Make: LUKER, Cat No : LSTE050S or techno-commercially equivalent in HAVELLS/BAJAJ/PHILIPS/JAGUAR |
| 6 | Supply and fix energy saving high power LED Bldg Security light of 30W or higher rating made up of pressure die cast aluminium housing + Toughened Glass having top opening, separate driver compartment with IP 65 protection, CRI > 80, CT>6000 K, Beam Angle - 120 degree, I/P Voltage Range 100-300 V, PF > 0.95, Luminous Efficiency > 100 Lumen/W, 6 KV Surge Voltage Protection, THD < 5%, & fixing/fitting on existing GI pipe bracket and connecting up electrically from Junction box to light ftg by means of 3 core 1.5 sqmm copper PVC round conductor passing through 15 mm dia light grade GI Pipe & necessary Aluminium clamps, nuts, bolts, washers etc. incl taking down old unsv conventional light fittings complete all as specified and directed by Engr-in-Charge. Make: LUKER, Cat No : LSTE030S or techno-commercially equivalent in HAVELLS/BAJAJ/PHILIPS/JAGUAR |
| 7 | S & F roof mounted energy saving, environment friendly, robust Die-Cast Aluminium Housing with Red Polycarbonate Dome LED Aviation Light luminaire with high efficacy of system wattage 10 W, Integral Driver, Supper Flux 5 mm 302 Nos LEDs, IP 65, with & including features of Protection against Short-Circuit & Surge, Voltage Range of 100-270VAC integrated type with all accessories internally prewired and including connecting up with necessaryfixing arrangements with & including 15/20 mm dia GI Pipe light grade duly threaded etc. & electrical connection complete all as specified and as directed by Engr-In-Charge incl taking down old/unsv light fittings & depositing to MES Storeyard. Cat No BGAV 302 LED of make BAJAJ or techno-commercially equiv in Philips/Crompton. |
| 8 | S&F LED flood light fitting of capacity 100 Watts or higher rating, Power factor >0.95, colour temperature not >5700 K, luminous efficacy > 110 lumens/watt, IP-65 including electronic driver SMPS based constant current supply, 10 KV Surge Voltage Protection, THD < 5%, output open/short circuit protection, phase to phase protection, over voltage protection, surge voltage protection etc. unit suitable for working voltage 140-270VAC, 50 Hz, pressure die cast aluminium housing + toughened glass and finishing epoxy powder coated with all accessories as per manufacturers instructions including necessary fixing arrangements by means of appropriate sized MS Clamps, nuts, bolts, washers etc. on wall/other surfaces and connecting up electrically with & including with & including flame proof flexible metallic conduit of required length duly enclosing external Drivers/SPDs incl connecting accessories & including 5 Years OEM Warranty on the fitting incl taking down old unsv conventional light fittings & depositing to MES Storeyard complete all as specified and directed by Engr-in-Charge. Model - ALCOR, Cat No : LFL100TGLN 5Y of Make LUKER or techno-commercially equivalent in HAVELLS/PHILIPS/JAGUAR. |
| 9 | S&F LED flood light fitting of capacity 50 Watts or higher rating, Power factor >0.95, colour temperature not >5700 K, luminous efficacy > 110 lumens/watt, IP-65 including electronic driver SMPS based constant current supply, 10 KV Surge Voltage Protection, THD < 5%, output open/short circuit protection, phase to phase protection, over voltage protection, surge voltage protection etc. unit suitable for working voltage 140-270VAC, 50 Hz, pressure die cast aluminium housing + toughened glass and finishing epoxy powder coated with all accessories as per manufacturers instructions including necessary fixing arrangements by means of appropriate sized MS Clamps, nuts, bolts, washers etc. on wall/other surfaces and connecting up electrically with & including flame proof flexible metallic conduit of required length duly enclosing external Drivers/SPDs incl connecting accessories & including 5 Years OEM Warranty on the fitting incl taking down old unsv conventional light fittings & depositing to MES Storeyard complete all as specified and directed by Engr-in-Charge. Model - ALCOR, Cat No : LFL50TGLN 5Y of Make LUKER or techno-commercially equivalent in HAVELLS/PHILIPS/JAGUAR. |
| 10 | S&F Surface and wall mounted LED batten 20 watts 4 feet long, extruded aluminium housing providedfor efficient heat dissipation & integrated electronic driver including connecting up with and including twin/three core twisted flexible cable of suitable size in flexible conduit all as specified and as directed. Make : LUKER, Cat No LT520P or techno-commercially equiv in Havells/Jaguar/Philips. |
| 11 | S & F LED square shape (2\" x 2\") slim ceiling SURFACE light fitting 40 W or next higher rating, CRI > 80, CT>5700 K (White), integrated type, with high efficiency electronic driver, surge suppressor/protection & high brightness LEDs, with suitable fixing arrangement complete with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size all as specified and as directed. Cat No : LKMSRS40N of make Luker or techno-commercially equiv in Havells/Jaguar/Philips. Imp Note for Item Nos 4 to 11 : 1) Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge/GE for Make/Sample approval of items whereever equivalency of Item(s) is concerned other than specified Make/Model/Cat/Part Ref concerned before placing order to the Manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. 3) The approximate height of installation/fixing of the High Bay/Flood LED fittings is around 8 to 12 Mtrs from Ground/FFL. 4) Contr is required to take all the safety precautions incl any type of ladders/scaffolding work & cost of the same is deemed to be included in the unit quoted rates. 5) Necessary test certificates i.e LM-79, LM-80 reports for all the LED Fittings & 5 Year Warranty Cerificate from the OEM for the High Bay Lights/Flood Lights etc. is to be submitted to the Engr-in-Charge for checking & record. 6) The contractor/firm is required to visit the site prior to quoting of the subject items/ work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm. 7) Cost is also deemed to be inclusive of required length of Flame Proof Flexible Metallic Conduit wherever specified in the item specifications above. |
| 12 | Supply and laying in trenches/through pipes or bare in road crossings/ paths /drains /ducts /floors /along poles/ walls/ ceilings/ equipments etc. Cable Under ground, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade ofcross sectional area, 4.0 Core 10 Sqmm incl connecting with suitable glands, lugs etc all as specified and directed by the Engr-in-Charge. Make: Havells/Finolex/Polycab/GlosterNOTE : Quoted rate is deemed to be inclusive of fixing/placing of Cable Route Indicator of type/size as appoved by the Engr-In-Charge at an interval of not more than 50.0 meters & at each & every bend or corner with engraved marking e.g. \" MES S/L CABLE 10 SQMM 4 CORE \" in bold letters during refilling of the trench complete all as specified & as directed by the Engr-In-Charge. |
| 13 | M&L for cutting the existing hardstanding/PCC/WBM road/rocky surfaces at a depth of not less than 75 cm & 30 cm in width for passing of HT cables through GI pipes, returning filling in, complete incl finishing the surfaces by providing cement concrete type B1 (1:2:4) with 20 mm graded aggregate upto 20 cm, finishing to a uniform smooth surface complete all as specified and as directed. |
| 14 | Excavation in trenches by mechanical means n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in hard dense soil complete.NOTE for Item No13 & 14: 1) The requirement of JCB (if any) for cutting the hard standing/PCC/WBM road surface or during earthwork is deemed to be included in the unit quoted rates. 2) If any damage to any Cable of Air Force/BSNL/MES etc. or to any Pipe lines develops/occurs during execution of the works then the same shall be made good by the Contr to the entire satisfaction of the concerned Dept/Section & the costs of the same is deemed to be included in the unit quoted rates.3) Quoted rate is also deemed to be inclusive of clearing/removing/cutting of vegetation/tree branches/small to medium plantings/bushes etc. so as to facilitate successful completion of the work. No extra/addl payment shall be allowed to the Contr in this regard.4) The contractor/firm is required to visit the site prior to quoting of the subject items/ work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm. |
| 15 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick. |
| 16 | Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point. |
| 17 | M&L for HDPE DWC (Double Wall Corrugated) Pipe ofrating 450 N, ISI marked with Min OD 77/75 mm & Min ID 63 mm, Orange colour for LT UG Cable protection with & including Couplers with rubber rings & RR & NFP properties/features confirming to IS 16205 Part 24:2018 & IEC 61386 Part 24:2007 complete all as specified & as directed by the Engr-In-Charge. Make : Supreme/Astral/Finolex/Polycab. |
| 18 | S&F danger notice plate of size 25 x 20cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 complete. |
| 19 | M&Lfor GI pipe light grade with all running fittings (ISI Marked), fixed on Perimeter/Street light PCC poles etc. of bore 15 mm complete all as specified and directed. Make : TATA/JINDAL/PRAKASH. |
| 20 | M&Lfor GI pipe light grade with all running fittings (ISI Marked), laid in trenches, under road or fixing on wall/pole/crossing drain/nallah etc. of bore 40 mm complete all as specified and directed. Make : TATA/JINDAL/PRAKASH.Note for Item Nos 19 & 20 : Wherever GI Protection pipes are to be placed/fitted above earths surface, cost of necessary clamping/fixing arrangements to the entire satisfaction of Engr-In-Charge is deemed to be included in the unit quoted rates. |
| 21 | Supply and fix energy saving high power LED Street light of 50W or higher rating made up of pressure die cast aluminum housing with embedded PC cover having top opening, seperate driver compartment with IP66 protection & fixing/fitting on existing GI pipe bracket and connecting up electrically from Junction box to light ftg by means of 3 core 1.5 sqmm copper PVC round conductor passing through 15 mm dia light grade GI Pipe & necessary Aluminium clamps, nuts, bolts, washers etc. incl taking down old unsv conventional light fittings complete all as specified and directed by Engr-in-Charge. Make: LUKER, Cat No : LSTE050S or techno-commercially equivalent in HAVELLS/BAJAJ/PHILIPS/JAGUAR |
| 22 | S & F loop in-loop out junction box of minimum internal dimension 140 x 140 x 95 mm or higher size made out of FRP sheet with weather proof canopy and locking screw comprising of 20 Amps rated 4 way connectors for 3 Phase and Neutral incoming/out going mounted in the box, fixing on RCC/Steel poles etc. with & including suitable sized Aluminium/MS clamps, cable glands, lugs, nuts, bolts etc. & fitted with 01 Nos MCB SP 10A, 10KA breaking capacity, C Series complete all as specified and as directed by Engr-in-Charge. Make of FRP Junction Box : Sintex/CAPE ELECTRIC/HENSEL or techno-commercially eqvt & Make of MCB SP : L&T/Legrand/ABB/SIEMENS.Imp Note for Item Nos 21 & 22 : 1) Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge/GE for Make/Sample approval of items whereever equivalency of Item(s) is concerned other than specified Make/Model/Cat/Part Ref concerned before placing order to the Manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. 3) Cost of 15 mm dia GI Pipes incl necessary clamping as directed by the Engr-In-Charge shall be measured & paid separately under relevant items. 4) Cost of use/hiring/rent including transportation of Aluminum Ladders/Scaffolding arrangements etc. required for successful execution of the complete work/Job is deemed to be included in the unit quoted rates. Quoted rate is also deemed to be inclusive of all safety precautions/measures to be taken by the contractor for labour employed at the site. |
| 23 | M&L for preparation of old painted surfaces of PCC/Steel Poles & applying two coats of weather coat paint of approved colour & grade (for PCC Poles) or applying two coats of Aluminium Paint over a coat of red oxide primer of approved colour & grade (for Steel Poles) incl writing of Pole Numbers & also painting of GI Pipe brackets & clamps with two coats of Aluminium Paint over a coat of red oxide primer complete all as specified & as directed by the Engr-In-Charge.NOTE : Cost of use/hiring/rent including transportation of Aluminum Ladders/Scaffolding arrangements etc. required for successful execution of the complete work/Job is deemed to be included in the unit quoted rates. Quoted rate is also deemed to be inclusive of all safety precautions/measures to be taken by the contractor for labour employed at the site. |